{"id":"https://openalex.org/W7217546334","doi":null,"title":"Adaptive Differential Protection for Enhanced Fault Detection in Dc Microgrids With Etap: A Review","display_name":"Adaptive Differential Protection for Enhanced Fault Detection in Dc Microgrids With Etap: A Review","alternate_titles":[],"publication_year":2024,"publication_date":"2024-10-01","ids":{"openalex":"https://openalex.org/W7217546334"},"language":"en","primary_location":{"id":"pmh:oai:ojs2.propulsiontechjournal.com:article/8588","doi":null,"is_oa":true,"landing_page_url":"https://propulsiontechjournal.com/index.php/journal/article/view/8588","pdf_url":"https://propulsiontechjournal.com/index.php/journal/article/download/8588/5377","source":{"id":"https://openalex.org/S2764809588","display_name":"Journal of Propulsion Technology","issn_l":"1001-4055","issn":["1001-4055"],"is_oa":true,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","poland-40","russia-white-list-3"],"host_organization":"https://openalex.org/P4327988833","host_organization_name":"Zhongguo Hangtian Gongye Zonggongsi","host_organization_lineage":["https://openalex.org/P4327988833"],"host_organization_lineage_names":["Zhongguo Hangtian Gongye Zonggongsi"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"1001-4055","raw_type":"info:eu-repo/semantics/article"},"parent_works":[],"lineage":["https://openalex.org/W7217546334"],"child_works_count":0,"type":"article","is_traditional":true,"indexed_in":[],"open_access":{"is_oa":true,"oa_status":"diamond","oa_url":"https://propulsiontechjournal.com/index.php/journal/article/download/8588/5377","any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5156168920","display_name":"Sindiso Mashavave, Ashish Zandawala, Kunalkumar P. Bhatt","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"Sindiso Mashavave","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5162312356","display_name":"Ashish Zandawala","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"Ashish Zandawala","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"last","author":{"id":"https://openalex.org/A5082417990","display_name":"Kunalkumar Bhatt","orcid":"https://orcid.org/0000-0003-0947-8134","observed_orcids":["https://orcid.org/0000-0003-0947-8134"]},"institutions":[],"countries":[],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"Kunalkumar P. Bhatt","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":true,"cited_by_count":0,"reviewed_by_count":0,"citation_normalized_percentile":{"value":0.0,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.9937000274658203,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.9937000274658203,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":0.004000000189989805,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.0007999999797903001,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/dc-microgrid","display_name":"DC microgrid","score":0.996999979019165},{"id":"https://openalex.org/keywords/fault-detection","display_name":"fault detection","score":0.9950000047683716},{"id":"https://openalex.org/keywords/etap","display_name":"ETAP","score":0.699999988079071},{"id":"https://openalex.org/keywords/power-system-protection","display_name":"power system protection","score":0.8159999847412109},{"id":"https://openalex.org/keywords/fault-isolation","display_name":"fault isolation","score":0.722000002861023},{"id":"https://openalex.org/keywords/renewable-energy-integration","display_name":"renewable energy integration","score":0.8180000185966492},{"id":"https://openalex.org/keywords/power-system-simulation","display_name":"power system simulation","score":0.7139999866485596}],"concepts":[{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.6194000244140625},{"id":"https://openalex.org/C152745839","wikidata":"https://www.wikidata.org/wiki/Q5438153","display_name":"Fault detection and isolation","level":3,"score":0.6011000275611877},{"id":"https://openalex.org/C38361682","wikidata":"https://www.wikidata.org/wiki/Q1756067","display_name":"Power-system protection","level":4,"score":0.4966999888420105},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4943999946117401},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.49300000071525574},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.48030000925064087},{"id":"https://openalex.org/C93226319","wikidata":"https://www.wikidata.org/wiki/Q193137","display_name":"Differential (mechanical device)","level":2,"score":0.4796000123023987},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.41769999265670776},{"id":"https://openalex.org/C188573790","wikidata":"https://www.wikidata.org/wiki/Q12705","display_name":"Renewable energy","level":2,"score":0.39800000190734863},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.39660000801086426},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.3625999987125397},{"id":"https://openalex.org/C2986957705","wikidata":"https://www.wikidata.org/wiki/Q1756067","display_name":"Differential protection","level":4,"score":0.34279999136924744},{"id":"https://openalex.org/C2776784348","wikidata":"https://www.wikidata.org/wiki/Q5762595","display_name":"Microgrid","level":3,"score":0.33980000019073486},{"id":"https://openalex.org/C52970973","wikidata":"https://www.wikidata.org/wiki/Q2497134","display_name":"Adaptive system","level":2,"score":0.3043999969959259},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.2994999885559082},{"id":"https://openalex.org/C2412688","wikidata":"https://www.wikidata.org/wiki/Q503732","display_name":"Protective relay","level":4,"score":0.2955999970436096},{"id":"https://openalex.org/C112930515","wikidata":"https://www.wikidata.org/wiki/Q4389547","display_name":"Risk analysis (engineering)","level":1,"score":0.28220000863075256},{"id":"https://openalex.org/C47949032","wikidata":"https://www.wikidata.org/wiki/Q663542","display_name":"Overcurrent","level":3,"score":0.267300009727478},{"id":"https://openalex.org/C186370098","wikidata":"https://www.wikidata.org/wiki/Q442787","display_name":"Energy (signal processing)","level":2,"score":0.26330000162124634},{"id":"https://openalex.org/C7817414","wikidata":"https://www.wikidata.org/wiki/Q1779504","display_name":"Energy management","level":3,"score":0.2506999969482422},{"id":"https://openalex.org/C26517878","wikidata":"https://www.wikidata.org/wiki/Q228039","display_name":"Key (lock)","level":2,"score":0.25060001015663147}],"mesh":[],"locations_count":1,"locations":[{"id":"pmh:oai:ojs2.propulsiontechjournal.com:article/8588","doi":null,"is_oa":true,"landing_page_url":"https://propulsiontechjournal.com/index.php/journal/article/view/8588","pdf_url":"https://propulsiontechjournal.com/index.php/journal/article/download/8588/5377","source":{"id":"https://openalex.org/S2764809588","display_name":"Journal of Propulsion Technology","issn_l":"1001-4055","issn":["1001-4055"],"is_oa":true,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","poland-40","russia-white-list-3"],"host_organization":"https://openalex.org/P4327988833","host_organization_name":"Zhongguo Hangtian Gongye Zonggongsi","host_organization_lineage":["https://openalex.org/P4327988833"],"host_organization_lineage_names":["Zhongguo Hangtian Gongye Zonggongsi"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"1001-4055","raw_type":"info:eu-repo/semantics/article"}],"best_oa_location":{"id":"pmh:oai:ojs2.propulsiontechjournal.com:article/8588","doi":null,"is_oa":true,"landing_page_url":"https://propulsiontechjournal.com/index.php/journal/article/view/8588","pdf_url":"https://propulsiontechjournal.com/index.php/journal/article/download/8588/5377","source":{"id":"https://openalex.org/S2764809588","display_name":"Journal of Propulsion Technology","issn_l":"1001-4055","issn":["1001-4055"],"is_oa":true,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","poland-40","russia-white-list-3"],"host_organization":"https://openalex.org/P4327988833","host_organization_name":"Zhongguo Hangtian Gongye Zonggongsi","host_organization_lineage":["https://openalex.org/P4327988833"],"host_organization_lineage_names":["Zhongguo Hangtian Gongye Zonggongsi"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"1001-4055","raw_type":"info:eu-repo/semantics/article"},"sustainable_development_goals":[{"score":0.75,"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7"},{"score":0.7207000255584717,"display_name":"Industry, innovation and infrastructure","id":"https://metadata.un.org/sdg/9"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":true,"grobid_xml":true},"content_urls":{"pdf":"https://content.openalex.org/works/W7217546334.pdf","grobid_xml":"https://content.openalex.org/works/W7217546334.grobid-xml"},"referenced_works_count":23,"referenced_works":["https://openalex.org/W2888459562","https://openalex.org/W2896013954","https://openalex.org/W2897414519","https://openalex.org/W2983044838","https://openalex.org/W3011154079","https://openalex.org/W3022323930","https://openalex.org/W3034494470","https://openalex.org/W3034780840","https://openalex.org/W3042440266","https://openalex.org/W3063947960","https://openalex.org/W3114038355","https://openalex.org/W3126255100","https://openalex.org/W3127912089","https://openalex.org/W3131765054","https://openalex.org/W3158375461","https://openalex.org/W3198344009","https://openalex.org/W3209614493","https://openalex.org/W4206821333","https://openalex.org/W4214728133","https://openalex.org/W4225137455","https://openalex.org/W4295038273","https://openalex.org/W4322769349","https://openalex.org/W4362695433"],"related_works":["https://openalex.org/W7160407919","https://openalex.org/W4295038273","https://openalex.org/W4394895322","https://openalex.org/W2922402609","https://openalex.org/W7116979704","https://openalex.org/W4406859004","https://openalex.org/W4401775507","https://openalex.org/W4293093467","https://openalex.org/W4400315044","https://openalex.org/W4313410294"],"abstract_inverted_index":{"DC":[0,31,69,121],"microgrids":[1],"are":[2,74],"becoming":[3],"increasingly":[4],"essential":[5],"in":[6,68,81,90,144,166],"today's":[7],"power":[8,107],"systems,":[9],"primarily":[10],"due":[11],"to":[12,15,64,76,111,175],"their":[13,79],"capacity":[14],"seamlessly":[16],"incorporate":[17],"renewable":[18],"energy":[19],"sources":[20],"and":[21,39,50,92,113,131,148,159],"enhance":[22],"overall":[23],"system":[24,86,108],"reliability.":[25],"However,":[26],"the":[27,34,98,101,135,138,146,156,170],"distinct":[28],"features":[29],"of":[30,36,103,127,140,150],"microgrids,":[32],"including":[33],"lack":[35],"current":[37,85],"zero-crossing":[38],"rapid":[40],"fault":[41,48,66,95,151],"propagation,":[42],"present":[43],"notable":[44],"challenges":[45,158],"for":[46,163,172],"conventional":[47],"detection":[49,67],"protection":[51,59,72,118,143],"strategies.":[52],"This":[53],"review":[54],"paper":[55,99,136],"examines":[56],"adaptive":[57,116,141],"differential":[58,117,142],"as":[60],"an":[61],"innovative":[62],"approach":[63],"improving":[65],"microgrids.":[70,122],"Adaptive":[71],"systems":[73],"designed":[75],"dynamically":[77],"adjust":[78],"settings":[80],"real-time,":[82],"based":[83],"on":[84],"conditions,":[87],"which":[88],"results":[89],"quicker":[91],"more":[93],"precise":[94],"isolation.":[96],"Furthermore,":[97],"investigates":[100],"application":[102],"ETAP,":[104],"a":[105,124],"prominent":[106],"simulation":[109],"tool,":[110],"model":[112],"validate":[114],"these":[115,177],"frameworks":[119],"within":[120],"Through":[123],"comprehensive":[125],"analysis":[126],"recent":[128],"technological":[129],"advancements":[130],"practical":[132],"case":[133],"studies,":[134],"underscores":[137],"advantages":[139],"enhancing":[145],"speed":[147],"precision":[149],"detection.":[152],"It":[153],"also":[154],"discusses":[155],"existing":[157],"outlines":[160],"potential":[161],"avenues":[162],"future":[164],"research":[165],"this":[167],"area,":[168],"emphasizing":[169],"need":[171],"continued":[173],"innovation":[174],"address":[176],"complexities.":[178]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W7217546334","counts_by_year":[],"updated_date":"2026-11-21T10:27:49.728292","created_date":"2026-10-03T00:00:00"}