{"id":"https://openalex.org/W7214106983","doi":"https://doi.org/10.1186/s42162-026-00710-0","title":"Optimal grid connection capacity of a hybrid renewable microgrid: an energy management and economic optimisation model","display_name":"Optimal grid connection capacity of a hybrid renewable microgrid: an energy management and economic optimisation model","alternate_titles":[],"publication_year":2026,"publication_date":"2026-11-17","ids":{"openalex":"https://openalex.org/W7214106983","doi":"https://doi.org/10.1186/s42162-026-00710-0"},"language":"en","primary_location":{"id":"doi:10.1186/s42162-026-00710-0","doi":"https://doi.org/10.1186/s42162-026-00710-0","is_oa":true,"landing_page_url":"https://doi.org/10.1186/s42162-026-00710-0","pdf_url":null,"source":{"id":"https://openalex.org/S3035173479","display_name":"Energy Informatics","issn_l":"2520-8942","issn":["2520-8942"],"is_oa":true,"is_in_doaj":true,"is_core":true,"listed_in":["cwts-core","doaj","jufo-1","norway-1","poland-20","russia-white-list-1"],"host_organization":"https://openalex.org/P4310319965","host_organization_name":"Springer Nature","host_organization_lineage":["https://openalex.org/P4310319965"],"host_organization_lineage_names":["Springer Nature"],"type":"journal"},"license":"cc-by-nc-nd","license_id":"https://openalex.org/licenses/cc-by-nc-nd","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Energy Informatics","raw_type":"journal-article"},"parent_works":[],"lineage":["https://openalex.org/W7214106983"],"child_works_count":0,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"gold","oa_url":"https://doi.org/10.1186/s42162-026-00710-0","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5032363859","display_name":"Ihor Buratynskyi","orcid":"https://orcid.org/0000-0003-2928-9621","observed_orcids":["https://orcid.org/0000-0003-2928-9621"]},"institutions":[{"id":"https://openalex.org/I4210139364","display_name":"General Energy Institute of National Academy of Sciences of Ukraine","ror":"https://ror.org/03dez2856","country_code":"UA","type":"facility","lineage":["https://openalex.org/I149851306","https://openalex.org/I4210139364"]}],"countries":["UA"],"is_corresponding":false,"raw_author_name":"Ihor Buratynskyi","raw_affiliation_strings":["General Energy Institute of National Academy of Sciences of Ukraine, Kyiv, 03150, Ukraine"],"raw_orcid":"https://orcid.org/0000-0003-2928-9621","affiliations":[{"raw_affiliation_string":"General Energy Institute of National Academy of Sciences of Ukraine, Kyiv, 03150, Ukraine","institution_ids":["https://openalex.org/I4210139364"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5072437042","display_name":"Artur O. Zaporozhets","orcid":"https://orcid.org/0000-0002-0704-4116","observed_orcids":["https://orcid.org/0000-0002-0704-4116"]},"institutions":[{"id":"https://openalex.org/I4210139364","display_name":"General Energy Institute of National Academy of Sciences of Ukraine","ror":"https://ror.org/03dez2856","country_code":"UA","type":"facility","lineage":["https://openalex.org/I149851306","https://openalex.org/I4210139364"]},{"id":"https://openalex.org/I99908691","display_name":"Yuan Ze University","ror":"https://ror.org/01fv1ds98","country_code":"TW","type":"education","lineage":["https://openalex.org/I99908691"]}],"countries":["TW","UA"],"is_corresponding":true,"raw_author_name":"Artur Zaporozhets","raw_affiliation_strings":["General Energy Institute of National Academy of Sciences of Ukraine, Kyiv, 03150, Ukraine","Green Technology Research Center, Yuan Ze University, Taoyuan City, 320315, Taiwan"],"raw_orcid":"https://orcid.org/0000-0002-0704-4116","affiliations":[{"raw_affiliation_string":"General Energy Institute of National Academy of Sciences of Ukraine, Kyiv, 03150, Ukraine","institution_ids":["https://openalex.org/I4210139364"]},{"raw_affiliation_string":"Green Technology Research Center, Yuan Ze University, Taoyuan City, 320315, Taiwan","institution_ids":["https://openalex.org/I99908691"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5102882253","display_name":"Andrii Bosak","orcid":"https://orcid.org/0000-0002-4667-9720","observed_orcids":["https://orcid.org/0000-0002-4667-9720"]},"institutions":[{"id":"https://openalex.org/I4210139364","display_name":"General Energy Institute of National Academy of Sciences of Ukraine","ror":"https://ror.org/03dez2856","country_code":"UA","type":"facility","lineage":["https://openalex.org/I149851306","https://openalex.org/I4210139364"]}],"countries":["UA"],"is_corresponding":false,"raw_author_name":"Andrii Bosak","raw_affiliation_strings":["General Energy Institute of National Academy of Sciences of Ukraine, Kyiv, 03150, Ukraine"],"raw_orcid":"https://orcid.org/0000-0002-4667-9720","affiliations":[{"raw_affiliation_string":"General Energy Institute of National Academy of Sciences of Ukraine, Kyiv, 03150, Ukraine","institution_ids":["https://openalex.org/I4210139364"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":2,"corresponding_author_ids":["https://openalex.org/A5072437042"],"corresponding_institution_ids":["https://openalex.org/I4210139364","https://openalex.org/I99908691"],"apc_list":{"value":1490,"currency":"USD","value_usd":1490},"apc_paid":{"value":1490,"currency":"USD","value_usd":1490},"fwci":0.0,"has_fulltext":true,"cited_by_count":0,"citation_normalized_percentile":{"value":0.0,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.975600004196167,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.975600004196167,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10424","display_name":"Electric Power System Optimization","score":0.007199999876320362,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11007","display_name":"Hybrid Renewable Energy Systems","score":0.004900000058114529,"subfield":{"id":"https://openalex.org/subfields/2102","display_name":"Energy Engineering and Power Technology"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/hybrid-renewable-microgrid","display_name":"hybrid renewable microgrid","score":0.9179999828338623},{"id":"https://openalex.org/keywords/grid-connection-capacity","display_name":"grid connection capacity","score":0.9539999961853027},{"id":"https://openalex.org/keywords/levelized-cost-of-electricity","display_name":"levelized cost of electricity","score":0.7440000176429749},{"id":"https://openalex.org/keywords/energy-management","display_name":"energy management","score":0.8130000233650208},{"id":"https://openalex.org/keywords/battery-energy-storage","display_name":"battery energy storage","score":0.8389999866485596},{"id":"https://openalex.org/keywords/photovoltaics","display_name":"photovoltaics","score":0.7620000243186951},{"id":"https://openalex.org/keywords/wind-energy","display_name":"wind energy","score":0.9190000295639038},{"id":"https://openalex.org/keywords/energy-imports-and-exports","display_name":"energy imports and exports","score":0.699999988079071},{"id":"https://openalex.org/keywords/day-ahead-electricity-market","display_name":"day-ahead market","score":0.6230000257492065},{"id":"https://openalex.org/keywords/economic-optimization","display_name":"economic optimization","score":0.6110000014305115}],"concepts":[{"id":"https://openalex.org/C40293303","wikidata":"https://www.wikidata.org/wiki/Q27137","display_name":"Electric power","level":3,"score":0.5906000137329102},{"id":"https://openalex.org/C2780945871","wikidata":"https://www.wikidata.org/wiki/Q194274","display_name":"Backup","level":2,"score":0.5882999897003174},{"id":"https://openalex.org/C2780685028","wikidata":"https://www.wikidata.org/wiki/Q1096907","display_name":"Grid connection","level":3,"score":0.5587000250816345},{"id":"https://openalex.org/C2776784348","wikidata":"https://www.wikidata.org/wiki/Q5762595","display_name":"Microgrid","level":3,"score":0.5482000112533569},{"id":"https://openalex.org/C188573790","wikidata":"https://www.wikidata.org/wiki/Q12705","display_name":"Renewable energy","level":2,"score":0.5289000272750854},{"id":"https://openalex.org/C78600449","wikidata":"https://www.wikidata.org/wiki/Q43302","display_name":"Wind power","level":2,"score":0.5194000005722046},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.4781999886035919},{"id":"https://openalex.org/C4311470","wikidata":"https://www.wikidata.org/wiki/Q159719","display_name":"Power station","level":2,"score":0.4523000121116638},{"id":"https://openalex.org/C123153844","wikidata":"https://www.wikidata.org/wiki/Q360897","display_name":"Base load power plant","level":4,"score":0.45019999146461487},{"id":"https://openalex.org/C423512","wikidata":"https://www.wikidata.org/wiki/Q383973","display_name":"Electricity generation","level":3,"score":0.4438999891281128},{"id":"https://openalex.org/C183739832","wikidata":"https://www.wikidata.org/wiki/Q339353","display_name":"Pumped-storage hydroelectricity","level":4,"score":0.42739999294281006},{"id":"https://openalex.org/C5979214","wikidata":"https://www.wikidata.org/wiki/Q126932","display_name":"Cost of electricity by source","level":4,"score":0.42399999499320984},{"id":"https://openalex.org/C73916439","wikidata":"https://www.wikidata.org/wiki/Q837718","display_name":"Energy storage","level":3,"score":0.40959998965263367},{"id":"https://openalex.org/C206658404","wikidata":"https://www.wikidata.org/wiki/Q12725","display_name":"Electricity","level":2,"score":0.40380001068115234},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.391400009393692},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.37929999828338623},{"id":"https://openalex.org/C121119573","wikidata":"https://www.wikidata.org/wiki/Q7915732","display_name":"Intermittent energy source","level":4,"score":0.3720000088214874},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.3720000088214874},{"id":"https://openalex.org/C98576551","wikidata":"https://www.wikidata.org/wiki/Q841798","display_name":"Electric potential energy","level":3,"score":0.36910000443458557},{"id":"https://openalex.org/C10558101","wikidata":"https://www.wikidata.org/wiki/Q689855","display_name":"Smart grid","level":2,"score":0.36340001225471497},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.36059999465942383},{"id":"https://openalex.org/C544738498","wikidata":"https://www.wikidata.org/wiki/Q861135","display_name":"Distributed generation","level":3,"score":0.36000001430511475},{"id":"https://openalex.org/C154594046","wikidata":"https://www.wikidata.org/wiki/Q18979989","display_name":"Peaking power plant","level":4,"score":0.35190001130104065},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.3400999903678894},{"id":"https://openalex.org/C7817414","wikidata":"https://www.wikidata.org/wiki/Q1779504","display_name":"Energy management","level":3,"score":0.3345000147819519},{"id":"https://openalex.org/C92311004","wikidata":"https://www.wikidata.org/wiki/Q80638","display_name":"Hydroelectricity","level":2,"score":0.320499986410141},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.3172000050544739},{"id":"https://openalex.org/C77715397","wikidata":"https://www.wikidata.org/wiki/Q931447","display_name":"Electrical load","level":3,"score":0.3059000074863434},{"id":"https://openalex.org/C2776422217","wikidata":"https://www.wikidata.org/wiki/Q13629441","display_name":"Electric vehicle","level":3,"score":0.30399999022483826},{"id":"https://openalex.org/C170777988","wikidata":"https://www.wikidata.org/wiki/Q2316331","display_name":"Electric power industry","level":3,"score":0.3009999990463257},{"id":"https://openalex.org/C555008776","wikidata":"https://www.wikidata.org/wiki/Q267298","display_name":"Battery (electricity)","level":3,"score":0.2897000014781952},{"id":"https://openalex.org/C2778813691","wikidata":"https://www.wikidata.org/wiki/Q1369832","display_name":"Purchasing","level":2,"score":0.2838999927043915},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.28279998898506165},{"id":"https://openalex.org/C66887028","wikidata":"https://www.wikidata.org/wiki/Q382444","display_name":"Marginal cost","level":2,"score":0.2827000021934509},{"id":"https://openalex.org/C2780992000","wikidata":"https://www.wikidata.org/wiki/Q17016113","display_name":"Generator (circuit theory)","level":3,"score":0.2815999984741211},{"id":"https://openalex.org/C2982719155","wikidata":"https://www.wikidata.org/wiki/Q25584060","display_name":"Energy source","level":3,"score":0.2808000147342682},{"id":"https://openalex.org/C133118237","wikidata":"https://www.wikidata.org/wiki/Q131502","display_name":"Electric generator","level":3,"score":0.2759999930858612},{"id":"https://openalex.org/C2777819126","wikidata":"https://www.wikidata.org/wiki/Q1326624","display_name":"Electric utility","level":2,"score":0.27469998598098755},{"id":"https://openalex.org/C187633118","wikidata":"https://www.wikidata.org/wiki/Q1317949","display_name":"Economic dispatch","level":4,"score":0.2732999920845032},{"id":"https://openalex.org/C182299520","wikidata":"https://www.wikidata.org/wiki/Q1289588","display_name":"Total cost","level":2,"score":0.26109999418258667}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1186/s42162-026-00710-0","doi":"https://doi.org/10.1186/s42162-026-00710-0","is_oa":true,"landing_page_url":"https://doi.org/10.1186/s42162-026-00710-0","pdf_url":null,"source":{"id":"https://openalex.org/S3035173479","display_name":"Energy Informatics","issn_l":"2520-8942","issn":["2520-8942"],"is_oa":true,"is_in_doaj":true,"is_core":true,"listed_in":["cwts-core","doaj","jufo-1","norway-1","poland-20","russia-white-list-1"],"host_organization":"https://openalex.org/P4310319965","host_organization_name":"Springer Nature","host_organization_lineage":["https://openalex.org/P4310319965"],"host_organization_lineage_names":["Springer Nature"],"type":"journal"},"license":"cc-by-nc-nd","license_id":"https://openalex.org/licenses/cc-by-nc-nd","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Energy Informatics","raw_type":"journal-article"},{"id":"doi:10.21203/rs.3.rs-10962738/v1","doi":"https://doi.org/10.21203/rs.3.rs-10962738/v1","is_oa":true,"landing_page_url":"https://doi.org/10.21203/rs.3.rs-10962738/v1","pdf_url":"https://www.researchsquare.com/article/rs-10962738/latest.pdf","source":{"id":"https://openalex.org/S4306525896","display_name":"Research Square","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Research Square","raw_type":"posted-content"}],"best_oa_location":{"id":"doi:10.1186/s42162-026-00710-0","doi":"https://doi.org/10.1186/s42162-026-00710-0","is_oa":true,"landing_page_url":"https://doi.org/10.1186/s42162-026-00710-0","pdf_url":null,"source":{"id":"https://openalex.org/S3035173479","display_name":"Energy Informatics","issn_l":"2520-8942","issn":["2520-8942"],"is_oa":true,"is_in_doaj":true,"is_core":true,"listed_in":["cwts-core","doaj","jufo-1","norway-1","poland-20","russia-white-list-1"],"host_organization":"https://openalex.org/P4310319965","host_organization_name":"Springer Nature","host_organization_lineage":["https://openalex.org/P4310319965"],"host_organization_lineage_names":["Springer Nature"],"type":"journal"},"license":"cc-by-nc-nd","license_id":"https://openalex.org/licenses/cc-by-nc-nd","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Energy Informatics","raw_type":"journal-article"},"sustainable_development_goals":[{"score":1.0,"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy"},{"score":0.7207000255584717,"id":"https://metadata.un.org/sdg/9","display_name":"Industry, innovation and infrastructure"},{"score":0.5351999998092651,"id":"https://metadata.un.org/sdg/13","display_name":"Climate action"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":true,"pdf":true},"content_urls":{"pdf":"https://content.openalex.org/works/W7214106983.pdf","grobid_xml":"https://content.openalex.org/works/W7214106983.grobid-xml"},"referenced_works_count":61,"referenced_works":["https://openalex.org/W2553208471","https://openalex.org/W2897550163","https://openalex.org/W2898662542","https://openalex.org/W2909194042","https://openalex.org/W3017380697","https://openalex.org/W3056480821","https://openalex.org/W3137454449","https://openalex.org/W3185623524","https://openalex.org/W3199939093","https://openalex.org/W3209122560","https://openalex.org/W4210266481","https://openalex.org/W4225247912","https://openalex.org/W4292387973","https://openalex.org/W4381296292","https://openalex.org/W4387831752","https://openalex.org/W4388794403","https://openalex.org/W4389954821","https://openalex.org/W4390757657","https://openalex.org/W4391374060","https://openalex.org/W4394836355","https://openalex.org/W4394921870","https://openalex.org/W4396657642","https://openalex.org/W4399732978","https://openalex.org/W4400386782","https://openalex.org/W4400599908","https://openalex.org/W4401706039","https://openalex.org/W4401740618","https://openalex.org/W4403351644","https://openalex.org/W4404410882","https://openalex.org/W4405855898","https://openalex.org/W4406599791","https://openalex.org/W4406940549","https://openalex.org/W4408540025","https://openalex.org/W4408922503","https://openalex.org/W4409535222","https://openalex.org/W4410051024","https://openalex.org/W4410284664","https://openalex.org/W4410597908","https://openalex.org/W4410755081","https://openalex.org/W4411871929","https://openalex.org/W4411926003","https://openalex.org/W4412722354","https://openalex.org/W4412940451","https://openalex.org/W4413943176","https://openalex.org/W4413953391","https://openalex.org/W4414418537","https://openalex.org/W4415041135","https://openalex.org/W4416265913","https://openalex.org/W4416811688","https://openalex.org/W4417199352","https://openalex.org/W7118003593","https://openalex.org/W7118025099","https://openalex.org/W7126040706","https://openalex.org/W7128729739","https://openalex.org/W7133518710","https://openalex.org/W7144220023","https://openalex.org/W7151996727","https://openalex.org/W7157265342","https://openalex.org/W7160057365","https://openalex.org/W7160878401","https://openalex.org/W7170076507"],"related_works":["https://openalex.org/W3047114267","https://openalex.org/W1990769950","https://openalex.org/W4390970897","https://openalex.org/W4229049844","https://openalex.org/W4393196962","https://openalex.org/W2529248733","https://openalex.org/W3083137670","https://openalex.org/W2402687484","https://openalex.org/W3159267960","https://openalex.org/W4407349727"],"abstract_inverted_index":{"Microgrids":[0],"are":[1],"usually":[2],"assessed":[3],"with":[4,143,158,207,238],"the":[5,34,38,49,63,69,79,83,86,89,102,107,114,122,128,132,139,144,148,200,208,215,221,232,243],"grid":[6],"connection":[7,35,67,90,202,240],"taken":[8],"as":[9],"given,":[10],"although":[11],"its":[12,19,97],"power":[13,28,65,91,203],"limits":[14,73],"import":[15,74,115],"and":[16,18,37,45,75,96,111,119,127,175,183,185],"export":[17,117],"cost":[20,36,81,98,130,146,227],"is":[21,29,92,99],"paid":[22],"before":[23],"operation":[24],"starts.":[25],"Choosing":[26],"this":[27],"therefore":[30],"a":[31,59,93,156,159,164,169,176,239],"trade-off":[32],"between":[33],"costs":[39,108],"of":[40,66,82,101,109,131,147],"imported":[41],"energy,":[42],"backup":[43,149,172],"generation":[44,110],"unserved":[46],"load,":[47,126,209],"which":[48,72],"reviewed":[50,87],"levelized-cost":[51],"formulations":[52],"do":[53],"not":[54],"capture.":[55],"This":[56],"paper":[57],"presents":[58],"model":[60],"for":[61,124,242],"determining":[62],"optimal":[64,201],"to":[68,77,194,214,220],"electric":[70],"grid,":[71],"export,":[76],"minimise":[78],"levelized":[80,226],"microgrid.":[84],"Unlike":[85],"formulations,":[88],"decision":[94],"variable":[95],"part":[100],"objective.":[103],"The":[104,225],"objective":[105],"combines":[106],"battery":[112],"storage,":[113],"costs,":[116,121],"revenues":[118],"fuel":[120,145],"penalties":[123],"lost":[125],"daily":[129],"connection.":[133],"A":[134],"cost-based":[135],"source-selection":[136],"strategy":[137],"compares":[138],"day-ahead":[140],"market":[141],"price":[142],"gas":[150,173],"generator":[151,174],"in":[152],"every":[153],"hour.":[154],"For":[155],"microgrid":[157],"60":[160],"kW":[161,166,171,178,196,212,217],"solar":[162],"plant,":[163,168],"20":[165],"wind":[167],"40":[170,193],"50":[177],"/":[179],"200":[180],"kWh":[181],"battery,":[182],"critical":[184],"non-critical":[186],"consumers":[187],"whose":[188],"maximum":[189,222,244],"load":[190,234],"ranges":[191],"from":[192,210],"240":[195],"across":[197],"six":[198],"scenarios,":[199],"grows":[204],"almost":[205],"proportionally":[206],"17.9":[211],"up":[213],"170":[216],"limit,":[218],"equal":[219],"possible":[223,245],"export.":[224,246],"decreases":[228],"by":[229],"2.8%":[230],"at":[231],"lowest":[233],"(40":[235],"kW)":[236],"compared":[237],"sized":[241]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W7214106983","counts_by_year":[],"updated_date":"2026-11-18T13:11:19.462570","created_date":"2026-09-24T00:00:00"}