{"id":"https://openalex.org/W7214014334","doi":"https://doi.org/10.3390/en19194498","title":"Comparative Analysis of Load Frequency Control Under Multi-Disturbance in Renewable-Integrated Power Systems","display_name":"Comparative Analysis of Load Frequency Control Under Multi-Disturbance in Renewable-Integrated Power Systems","publication_year":2026,"publication_date":"2026-09-22","ids":{"openalex":"https://openalex.org/W7214014334","doi":"https://doi.org/10.3390/en19194498"},"language":"en","primary_location":{"id":"doi:10.3390/en19194498","doi":"https://doi.org/10.3390/en19194498","is_oa":true,"landing_page_url":"https://doi.org/10.3390/en19194498","pdf_url":null,"source":{"id":"https://openalex.org/S198098182","display_name":"Energies","issn_l":"1996-1073","issn":["1996-1073"],"is_oa":true,"is_in_doaj":true,"is_core":true,"listed_in":["anvur-class-a","anvur-scientific","cwts-core","doaj","norway-1","poland-140","russia-white-list-2","vabb-shw"],"host_organization":"https://openalex.org/P4310310987","host_organization_name":"Multidisciplinary Digital Publishing Institute","host_organization_lineage":["https://openalex.org/P4310310987"],"host_organization_lineage_names":["Multidisciplinary Digital Publishing Institute"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Energies","raw_type":"journal-article"},"volume":null,"type":"article","is_traditional":true,"indexed_in":["crossref","doaj"],"open_access":{"is_oa":true,"oa_status":"gold","oa_url":"https://doi.org/10.3390/en19194498","any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5006020517","display_name":"Kavita Behara","orcid":"https://orcid.org/0000-0002-8877-5630","observed_orcids":["https://orcid.org/0000-0002-8877-5630"]},"institutions":[{"id":"https://openalex.org/I160825796","display_name":"Mangosuthu University of Technology","ror":"https://ror.org/054r97095","country_code":"ZA","type":"education","lineage":["https://openalex.org/I160825796"]}],"countries":["ZA"],"is_corresponding":true,"raw_author_name":"Kavita Behara","raw_affiliation_strings":["Department of Electrical Engineering, Mangosuthu University of Technology, 511 Griffiths Mxenge Highway, Umlazi 4031, KwaZulu-Natal, South Africa"],"raw_orcid":"https://orcid.org/0000-0002-8877-5630","affiliations":[{"raw_affiliation_string":"Department of Electrical Engineering, Mangosuthu University of Technology, 511 Griffiths Mxenge Highway, Umlazi 4031, KwaZulu-Natal, South Africa","institution_ids":["https://openalex.org/I160825796"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":["https://openalex.org/A5006020517"],"corresponding_institution_ids":["https://openalex.org/I160825796"],"apc_list":{"value":2600,"currency":"CHF","value_usd":3137},"apc_paid":{"value":2600,"currency":"CHF","value_usd":3137},"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.0,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"19","issue":"19","first_page":"4498","last_page":"4498"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T12277","display_name":"Frequency Control in Power Systems","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T12277","display_name":"Frequency Control in Power Systems","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11081","display_name":"Advanced Control Systems Design","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/load-frequency-control","display_name":"load frequency control","score":1.0},{"id":"https://openalex.org/keywords/renewable-energy-integration","display_name":"renewable energy integration","score":0.9200000166893005},{"id":"https://openalex.org/keywords/frequency-regulation","display_name":"frequency regulation","score":0.48500001430511475},{"id":"https://openalex.org/keywords/fuzzy-logic-control","display_name":"fuzzy logic control","score":0.7630000114440918},{"id":"https://openalex.org/keywords/fractional-order-pid-control","display_name":"fractional-order PID control","score":0.8809999823570251},{"id":"https://openalex.org/keywords/adaptive-neuro-fuzzy-inference-system","display_name":"adaptive neuro-fuzzy inference system","score":0.9309999942779541},{"id":"https://openalex.org/keywords/low-inertia-power-systems","display_name":"low-inertia power systems","score":0.6370000243186951},{"id":"https://openalex.org/keywords/disturbance-rejection","display_name":"disturbance rejection","score":0.6010000109672546},{"id":"https://openalex.org/keywords/single-area-power-system","display_name":"single area power system","score":0.6430000066757202}],"concepts":[{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.7879999876022339},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.7053999900817871},{"id":"https://openalex.org/C25915539","wikidata":"https://www.wikidata.org/wiki/Q220786","display_name":"Automatic frequency control","level":2,"score":0.6894999742507935},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.5126000046730042},{"id":"https://openalex.org/C47116090","wikidata":"https://www.wikidata.org/wiki/Q716829","display_name":"PID controller","level":3,"score":0.5059999823570251},{"id":"https://openalex.org/C58166","wikidata":"https://www.wikidata.org/wiki/Q224821","display_name":"Fuzzy logic","level":2,"score":0.4867999851703644},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.447299987077713},{"id":"https://openalex.org/C195975749","wikidata":"https://www.wikidata.org/wiki/Q1475705","display_name":"Fuzzy control system","level":3,"score":0.4302000105381012},{"id":"https://openalex.org/C17500928","wikidata":"https://www.wikidata.org/wiki/Q959968","display_name":"Control system","level":2,"score":0.41280001401901245},{"id":"https://openalex.org/C186108316","wikidata":"https://www.wikidata.org/wiki/Q352530","display_name":"Adaptive neuro fuzzy inference system","level":4,"score":0.4059000015258789},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.4025999903678894},{"id":"https://openalex.org/C110407247","wikidata":"https://www.wikidata.org/wiki/Q122508","display_name":"Inertia","level":2,"score":0.3797000050544739},{"id":"https://openalex.org/C45872418","wikidata":"https://www.wikidata.org/wiki/Q5318966","display_name":"Dynamic demand","level":3,"score":0.37790000438690186},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.3659000098705292},{"id":"https://openalex.org/C188573790","wikidata":"https://www.wikidata.org/wiki/Q12705","display_name":"Renewable energy","level":2,"score":0.3621000051498413},{"id":"https://openalex.org/C2778763806","wikidata":"https://www.wikidata.org/wiki/Q4826572","display_name":"Automatic Generation Control","level":4,"score":0.3537999987602234},{"id":"https://openalex.org/C123919525","wikidata":"https://www.wikidata.org/wiki/Q761942","display_name":"Frequency deviation","level":3,"score":0.353300005197525},{"id":"https://openalex.org/C112972136","wikidata":"https://www.wikidata.org/wiki/Q7595718","display_name":"Stability (learning theory)","level":2,"score":0.33399999141693115},{"id":"https://openalex.org/C78600449","wikidata":"https://www.wikidata.org/wiki/Q43302","display_name":"Wind power","level":2,"score":0.33320000767707825},{"id":"https://openalex.org/C8590192","wikidata":"https://www.wikidata.org/wiki/Q1054694","display_name":"Frequency response","level":2,"score":0.329800009727478},{"id":"https://openalex.org/C2776098794","wikidata":"https://www.wikidata.org/wiki/Q6663315","display_name":"Load regulation","level":3,"score":0.32910001277923584},{"id":"https://openalex.org/C108755667","wikidata":"https://www.wikidata.org/wiki/Q1930258","display_name":"AC power","level":3,"score":0.29490000009536743},{"id":"https://openalex.org/C203479927","wikidata":"https://www.wikidata.org/wiki/Q5165939","display_name":"Controller (irrigation)","level":2,"score":0.29429998993873596},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.2928999960422516},{"id":"https://openalex.org/C82327864","wikidata":"https://www.wikidata.org/wiki/Q835100","display_name":"Intelligent control","level":2,"score":0.28600001335144043},{"id":"https://openalex.org/C56685638","wikidata":"https://www.wikidata.org/wiki/Q2300474","display_name":"Power control","level":3,"score":0.2856999933719635},{"id":"https://openalex.org/C107464732","wikidata":"https://www.wikidata.org/wiki/Q235781","display_name":"Adaptive control","level":3,"score":0.28029999136924744},{"id":"https://openalex.org/C2777601987","wikidata":"https://www.wikidata.org/wiki/Q5283581","display_name":"Disturbance (geology)","level":2,"score":0.2667999863624573},{"id":"https://openalex.org/C2983304839","wikidata":"https://www.wikidata.org/wiki/Q1747997","display_name":"Frequency regulation","level":4,"score":0.2605000138282776},{"id":"https://openalex.org/C423512","wikidata":"https://www.wikidata.org/wiki/Q383973","display_name":"Electricity generation","level":3,"score":0.257999986410141}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.3390/en19194498","doi":"https://doi.org/10.3390/en19194498","is_oa":true,"landing_page_url":"https://doi.org/10.3390/en19194498","pdf_url":null,"source":{"id":"https://openalex.org/S198098182","display_name":"Energies","issn_l":"1996-1073","issn":["1996-1073"],"is_oa":true,"is_in_doaj":true,"is_core":true,"listed_in":["anvur-class-a","anvur-scientific","cwts-core","doaj","norway-1","poland-140","russia-white-list-2","vabb-shw"],"host_organization":"https://openalex.org/P4310310987","host_organization_name":"Multidisciplinary Digital Publishing Institute","host_organization_lineage":["https://openalex.org/P4310310987"],"host_organization_lineage_names":["Multidisciplinary Digital Publishing Institute"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Energies","raw_type":"journal-article"},{"id":"pmh:oai:doaj.org/article:75f88747fd11412a903e72a764a40d67","doi":null,"is_oa":false,"landing_page_url":"https://doaj.org/article/75f88747fd11412a903e72a764a40d67","pdf_url":null,"source":{"id":"https://openalex.org/S4306401280","display_name":"DOAJ (DOAJ: Directory of Open Access Journals)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Energies, Vol 19, Iss 19, p 4498 (2026)","raw_type":"article"}],"best_oa_location":{"id":"doi:10.3390/en19194498","doi":"https://doi.org/10.3390/en19194498","is_oa":true,"landing_page_url":"https://doi.org/10.3390/en19194498","pdf_url":null,"source":{"id":"https://openalex.org/S198098182","display_name":"Energies","issn_l":"1996-1073","issn":["1996-1073"],"is_oa":true,"is_in_doaj":true,"is_core":true,"listed_in":["anvur-class-a","anvur-scientific","cwts-core","doaj","norway-1","poland-140","russia-white-list-2","vabb-shw"],"host_organization":"https://openalex.org/P4310310987","host_organization_name":"Multidisciplinary Digital Publishing Institute","host_organization_lineage":["https://openalex.org/P4310310987"],"host_organization_lineage_names":["Multidisciplinary Digital Publishing Institute"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Energies","raw_type":"journal-article"},"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","score":0.9853000044822693,"display_name":"Affordable and clean energy"},{"id":"https://metadata.un.org/sdg/9","score":0.7207000255584717,"display_name":"Industry, innovation and infrastructure"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":36,"referenced_works":["https://openalex.org/W2885507273","https://openalex.org/W3007533444","https://openalex.org/W3085597228","https://openalex.org/W3159723525","https://openalex.org/W4280589559","https://openalex.org/W4388147494","https://openalex.org/W4391996705","https://openalex.org/W4399802093","https://openalex.org/W4401894102","https://openalex.org/W4403836761","https://openalex.org/W4404563140","https://openalex.org/W4405588896","https://openalex.org/W4405881023","https://openalex.org/W4406963752","https://openalex.org/W4407270009","https://openalex.org/W4408267779","https://openalex.org/W4408877681","https://openalex.org/W4410019304","https://openalex.org/W4410348020","https://openalex.org/W4410744715","https://openalex.org/W4410780161","https://openalex.org/W4411607192","https://openalex.org/W4411922670","https://openalex.org/W4413893449","https://openalex.org/W4414603185","https://openalex.org/W4414712357","https://openalex.org/W4415237008","https://openalex.org/W4415282346","https://openalex.org/W4415285993","https://openalex.org/W4415423545","https://openalex.org/W4416497914","https://openalex.org/W7116940351","https://openalex.org/W7118784047","https://openalex.org/W7125809015","https://openalex.org/W7133941944","https://openalex.org/W7165182266"],"related_works":["https://openalex.org/W4408267779","https://openalex.org/W7135215942","https://openalex.org/W4281560508","https://openalex.org/W7202117129","https://openalex.org/W4417047814","https://openalex.org/W7167889405","https://openalex.org/W7165182266","https://openalex.org/W7154466955","https://openalex.org/W7163743305","https://openalex.org/W4414231766"],"abstract_inverted_index":{"Load":[0],"frequency":[1,8,114,118,139,192],"control":[2,38,67,72,170,185,206],"(LFC)":[3],"is":[4,110],"essential":[5],"for":[6,208],"maintaining":[7],"stability":[9],"and":[10,29,61,78,105,122,141,147,167,191,200,214],"reliable":[11],"operation":[12],"in":[13,47,194],"modern":[14],"power":[15,31,98,198,209],"systems,":[16],"particularly":[17],"with":[18],"increasing":[19],"penetration":[20],"of":[21,54,125,204],"renewable":[22,97],"energy":[23],"sources,":[24],"where":[25],"reduced":[26],"system":[27,83,199],"inertia":[28],"stochastic":[30],"fluctuations":[32],"pose":[33],"significant":[34],"challenges":[35],"to":[36],"conventional":[37,55,145],"strategies.":[39],"This":[40],"study":[41],"develops":[42],"a":[43,51],"single-area":[44],"LFC":[45],"model":[46],"MATLAB/Simulink.":[48],"It":[49],"presents":[50],"comparative":[52,130],"evaluation":[53],"linear":[56],"controllers,":[57,64],"namely":[58],"proportional\u2013integral":[59],"(PI)":[60],"proportional\u2013integral\u2013derivative":[62,75],"(PID)":[63],"alongside":[65],"advanced":[66,134,184],"strategies":[68,186],"comprising":[69],"fuzzy":[70,168],"logic":[71,169],"(FLC),":[73],"fractional-order":[74],"(FOPID)":[76],"control,":[77],"an":[79],"adaptive":[80],"neuro-fuzzy":[81],"inference":[82],"(ANFIS).":[84],"The":[85,129],"controllers":[86,135],"are":[87],"evaluated":[88],"under":[89,176,212],"multiple":[90],"disturbance":[91,142,162],"conditions,":[92],"including":[93],"step":[94],"load":[95,101],"changes,":[96],"fluctuations,":[99],"random":[100],"variations,":[102],"measurement":[103],"noise,":[104],"fault":[106],"events.":[107],"Their":[108],"performance":[109,159],"assessed":[111],"using":[112],"peak":[113],"deviation,":[115,119],"which":[116],"means":[117],"root-mean-square":[120],"error,":[121],"the":[123,151,156,161,195,202],"integral":[124],"time-weighted":[126],"absolute":[127],"error.":[128],"analysis":[131],"demonstrates":[132],"that":[133,183],"generally":[136],"provide":[137],"better":[138],"regulation":[140,193],"rejection":[143],"than":[144],"PI":[146],"PID":[148],"controllers.":[149],"Among":[150],"investigated":[152,196],"approaches,":[153],"ANFIS":[154],"exhibits":[155],"strongest":[157],"overall":[158],"across":[160],"scenarios":[163],"considered,":[164],"while":[165],"FOPID":[166],"also":[171],"demonstrate":[172],"improved":[173],"dynamic":[174],"responses":[175],"specific":[177],"operating":[178,211],"conditions.":[179,216],"These":[180],"findings":[181],"indicate":[182],"can":[187],"enhance":[188],"damping,":[189],"robustness,":[190],"renewable-integrated":[197],"highlight":[201],"potential":[203],"intelligent":[205],"techniques":[207],"systems":[210],"variable":[213],"uncertain":[215]},"counts_by_year":[],"updated_date":"2026-10-17T09:40:24.721904","created_date":"2026-09-23T00:00:00"}
