{"id":"https://openalex.org/W7213419645","doi":"https://doi.org/10.1109/sefet69291.2026.11687189","title":"Closed-Form Fault Location for Short Untransposed Transmission Lines Using Only Post-Fault Data","display_name":"Closed-Form Fault Location for Short Untransposed Transmission Lines Using Only Post-Fault Data","publication_year":2026,"publication_date":"2026-07-01","ids":{"openalex":"https://openalex.org/W7213419645","doi":"https://doi.org/10.1109/sefet69291.2026.11687189"},"language":"en","primary_location":{"id":"doi:10.1109/sefet69291.2026.11687189","doi":"https://doi.org/10.1109/sefet69291.2026.11687189","is_oa":true,"landing_page_url":"https://doi.org/10.1109/sefet69291.2026.11687189","pdf_url":null,"source":{"id":"https://openalex.org/S4363607997","display_name":"IEEE International Conference on Sustainable Energy and Future Electric Transportation (SEFET)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2026 IEEE 6th International Conference on Sustainable Energy and Future Electric Transportation (SEFET)","raw_type":"proceedings-article"},"volume":null,"type":"conference-paper","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"hybrid","oa_url":"https://doi.org/10.1109/sefet69291.2026.11687189","any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5072966000","display_name":"Rohit Ray","orcid":"https://orcid.org/0000-0002-3534-3674","observed_orcids":["https://orcid.org/0000-0002-3534-3674"]},"institutions":[{"id":"https://openalex.org/I132153292","display_name":"Indian Institute of Technology Patna","ror":"https://ror.org/01ft5vz71","country_code":"IN","type":"education","lineage":["https://openalex.org/I132153292"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Rohit Ray","raw_affiliation_strings":["IIT Patna"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"IIT Patna","institution_ids":["https://openalex.org/I132153292"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5053221049","display_name":"Kaustav Kalita","orcid":"https://orcid.org/0000-0003-3250-3035","observed_orcids":["https://orcid.org/0000-0003-3250-3035"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Kaustav Kalita","raw_affiliation_strings":["PGCIL"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"PGCIL","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5042723260","display_name":"Shanmugavelu Sivasubramani","orcid":"https://orcid.org/0000-0002-6657-3958","observed_orcids":["https://orcid.org/0000-0002-6657-3958"]},"institutions":[{"id":"https://openalex.org/I132153292","display_name":"Indian Institute of Technology Patna","ror":"https://ror.org/01ft5vz71","country_code":"IN","type":"education","lineage":["https://openalex.org/I132153292"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"S. Sivasubramani","raw_affiliation_strings":["IIT Patna"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"IIT Patna","institution_ids":["https://openalex.org/I132153292"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5028344078","display_name":"Abhineet Prakash","orcid":"https://orcid.org/0000-0002-4613-9994","observed_orcids":["https://orcid.org/0000-0002-4613-9994"]},"institutions":[{"id":"https://openalex.org/I99729588","display_name":"Indian Institute of Technology Bhubaneswar","ror":"https://ror.org/04gx72j20","country_code":"IN","type":"education","lineage":["https://openalex.org/I99729588"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Abhineet Prakash","raw_affiliation_strings":["IIT Bhubaneswer"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"IIT Bhubaneswer","institution_ids":["https://openalex.org/I99729588"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5072805378","display_name":"Sanjoy Kumar Parida","orcid":"https://orcid.org/0000-0003-4664-3338","observed_orcids":["https://orcid.org/0000-0003-4664-3338"]},"institutions":[{"id":"https://openalex.org/I132153292","display_name":"Indian Institute of Technology Patna","ror":"https://ror.org/01ft5vz71","country_code":"IN","type":"education","lineage":["https://openalex.org/I132153292"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"S.K. Parida","raw_affiliation_strings":["IIT Patna"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"IIT Patna","institution_ids":["https://openalex.org/I132153292"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.0,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"6"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.9980000257492065,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.9980000257492065,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.0017000000225380063,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12737","display_name":"Electrical Fault Detection and Protection","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/fault-localization","display_name":"fault location","score":0.949999988079071},{"id":"https://openalex.org/keywords/untransposed-transmission-lines","display_name":"untransposed transmission lines","score":0.9649999737739563},{"id":"https://openalex.org/keywords/short-transmission-lines","display_name":"short transmission lines","score":0.8759999871253967},{"id":"https://openalex.org/keywords/closed-form-algorithm","display_name":"closed-form algorithm","score":0.9570000171661377},{"id":"https://openalex.org/keywords/unsynchronized-measurements","display_name":"unsynchronized measurements","score":0.8569999933242798},{"id":"https://openalex.org/keywords/asymmetric-faults","display_name":"unbalanced faults","score":0.9520000219345093},{"id":"https://openalex.org/keywords/power-system-protection","display_name":"power system protection","score":0.718999981880188}],"concepts":[{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.5083000063896179},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.48159998655319214},{"id":"https://openalex.org/C761482","wikidata":"https://www.wikidata.org/wiki/Q118093","display_name":"Transmission (telecommunications)","level":2,"score":0.37450000643730164},{"id":"https://openalex.org/C140311924","wikidata":"https://www.wikidata.org/wiki/Q200928","display_name":"Electric power transmission","level":2,"score":0.30790001153945923},{"id":"https://openalex.org/C11413529","wikidata":"https://www.wikidata.org/wiki/Q8366","display_name":"Algorithm","level":1,"score":0.27410000562667847},{"id":"https://openalex.org/C152745839","wikidata":"https://www.wikidata.org/wiki/Q5438153","display_name":"Fault detection and isolation","level":3,"score":0.25609999895095825},{"id":"https://openalex.org/C198352243","wikidata":"https://www.wikidata.org/wiki/Q37105","display_name":"Line (geometry)","level":2,"score":0.23579999804496765},{"id":"https://openalex.org/C33441834","wikidata":"https://www.wikidata.org/wiki/Q693004","display_name":"Transmission line","level":2,"score":0.2313999980688095},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.22609999775886536},{"id":"https://openalex.org/C2776401178","wikidata":"https://www.wikidata.org/wiki/Q12050496","display_name":"Feature (linguistics)","level":2,"score":0.2224999964237213}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/sefet69291.2026.11687189","doi":"https://doi.org/10.1109/sefet69291.2026.11687189","is_oa":true,"landing_page_url":"https://doi.org/10.1109/sefet69291.2026.11687189","pdf_url":null,"source":{"id":"https://openalex.org/S4363607997","display_name":"IEEE International Conference on Sustainable Energy and Future Electric Transportation (SEFET)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2026 IEEE 6th International Conference on Sustainable Energy and Future Electric Transportation (SEFET)","raw_type":"proceedings-article"}],"best_oa_location":{"id":"doi:10.1109/sefet69291.2026.11687189","doi":"https://doi.org/10.1109/sefet69291.2026.11687189","is_oa":true,"landing_page_url":"https://doi.org/10.1109/sefet69291.2026.11687189","pdf_url":null,"source":{"id":"https://openalex.org/S4363607997","display_name":"IEEE International Conference on Sustainable Energy and Future Electric Transportation (SEFET)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2026 IEEE 6th International Conference on Sustainable Energy and Future Electric Transportation (SEFET)","raw_type":"proceedings-article"},"sustainable_development_goals":[{"score":0.8970999717712402,"id":"https://metadata.un.org/sdg/9","display_name":"Industry, innovation and infrastructure"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":18,"referenced_works":["https://openalex.org/W1965481914","https://openalex.org/W1974782891","https://openalex.org/W1993786104","https://openalex.org/W2002010700","https://openalex.org/W2038379866","https://openalex.org/W2106634663","https://openalex.org/W2123587279","https://openalex.org/W2126229465","https://openalex.org/W2275393404","https://openalex.org/W2570465035","https://openalex.org/W2606582741","https://openalex.org/W2992442490","https://openalex.org/W2993308361","https://openalex.org/W3172052970","https://openalex.org/W4379805526","https://openalex.org/W4388691939","https://openalex.org/W4406412765","https://openalex.org/W4410583929"],"related_works":["https://openalex.org/W2998746782","https://openalex.org/W2934522535","https://openalex.org/W3145012478","https://openalex.org/W2591298610","https://openalex.org/W2176969543","https://openalex.org/W2030493988","https://openalex.org/W1481387046","https://openalex.org/W2591810659","https://openalex.org/W4247859941","https://openalex.org/W2041618591"],"abstract_inverted_index":{"In":[0],"practical":[1],"power":[2,34],"systems,":[3],"transmission":[4,49],"lines":[5,50],"are":[6],"often":[7],"operated":[8],"in":[9,46],"an":[10],"untransposed":[11,48],"configuration,":[12],"which":[13],"can":[14],"degrade":[15],"the":[16,85,88,98,105,119],"accuracy":[17,135],"of":[18,97,118],"conventional":[19],"fault-location":[20,131],"methods.":[21],"Accurate":[22],"fault":[23,44,138],"location":[24,45],"is":[25,75,101,121],"essential":[26],"for":[27,42,107],"minimizing":[28],"outage":[29],"duration":[30],"and":[31,66],"ensuring":[32],"reliable":[33],"supply.":[35],"This":[36],"paper":[37],"presents":[38],"a":[39],"closed-form":[40],"algorithm":[41,89,120],"estimating":[43],"short":[47],"that":[51,79,102],"does":[52],"not":[53],"need":[54,106],"line":[55],"parameters":[56],"to":[57,91],"be":[58],"known.":[59],"The":[60,72,94,116],"method":[61],"operates":[62],"using":[63],"unsynchronized":[64],"voltage":[65],"current":[67],"measurements":[68,109],"from":[69],"both":[70],"terminals.":[71],"synchronization":[73,114],"angle":[74],"estimated":[76],"by":[77],"assuming":[78],"one":[80],"phase":[81],"remains":[82],"healthy":[83],"during":[84],"fault,":[86],"making":[87],"applicable":[90],"asymmetrical":[92],"faults.":[93],"key":[95],"contribution":[96],"proposed":[99],"approach":[100],"it":[103],"eliminates":[104],"pre-fault":[108],"while":[110],"maintaining":[111],"robustness":[112],"against":[113],"mismatch.":[115],"performance":[117],"validated":[122],"through":[123],"detailed":[124],"PSCAD":[125],"simulations.":[126],"Comparative":[127],"analysis":[128],"with":[129],"existing":[130],"techniques":[132],"demonstrates":[133],"improved":[134],"under":[136],"various":[137],"conditions.":[139]},"counts_by_year":[],"updated_date":"2026-11-08T12:12:28.789561","created_date":"2026-09-17T00:00:00"}
