{"id":"https://openalex.org/W7211908111","doi":"https://doi.org/10.68159/h030651861","title":"Alarm Fatigue Mitigation Under Safety Constraints: A Context-Aware Suppression Design Framework","display_name":"Alarm Fatigue Mitigation Under Safety Constraints: A Context-Aware Suppression Design Framework","alternate_titles":[],"publication_year":2025,"publication_date":"2025-01-01","ids":{"openalex":"https://openalex.org/W7211908111","doi":"https://doi.org/10.68159/h030651861"},"language":"en","primary_location":{"id":"doi:10.68159/h030651861","doi":"https://doi.org/10.68159/h030651861","is_oa":true,"landing_page_url":"https://doi.org/10.68159/h030651861","pdf_url":"https://cirpublications.com/storage/pub-article-files/article-h030651861.pdf?ts=1788793279","source":{"id":"https://openalex.org/S7407064685","display_name":"Journal of Health Informatics and Digital Systems","issn_l":"3149-8973","issn":["3149-8973"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":"cc-by-nc-sa","license_id":"https://openalex.org/licenses/cc-by-nc-sa","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Journal of Health Informatics and Digital Systems","raw_type":"journal-article"},"parent_works":[],"lineage":["https://openalex.org/W7211908111"],"child_works_count":0,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"hybrid","oa_url":"https://cirpublications.com/storage/pub-article-files/article-h030651861.pdf?ts=1788793279","any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5150690034","display_name":"Ahmed Youssef","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I150406212","display_name":"University of Khartoum","ror":"https://ror.org/02jbayz55","country_code":"SD","type":"education","lineage":["https://openalex.org/I150406212"]}],"countries":["SD"],"is_corresponding":true,"contributor_roles":[],"raw_author_name":"Ahmed Youssef","raw_affiliation_strings":["Department of Health Informatics , Faculty of Medicine , University of Khartoum , Khartoum , Sudan"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Health Informatics , Faculty of Medicine , University of Khartoum , Khartoum , Sudan","institution_ids":["https://openalex.org/I150406212"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5137444978","display_name":"Khaled Hassan","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"Khaled Hassan","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":["https://openalex.org/A5150690034"],"corresponding_institution_ids":["https://openalex.org/I150406212"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":true,"cited_by_count":0,"reviewed_by_count":0,"citation_normalized_percentile":{"value":0.0,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"5","issue":"2","first_page":null,"last_page":null},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T13248","display_name":"Healthcare Technology and Patient Monitoring","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2746","display_name":"Surgery"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},"topics":[{"id":"https://openalex.org/T13248","display_name":"Healthcare Technology and Patient Monitoring","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2746","display_name":"Surgery"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T10350","display_name":"Electronic Health Records Systems","score":0.0,"subfield":{"id":"https://openalex.org/subfields/3605","display_name":"Health Information Management"},"field":{"id":"https://openalex.org/fields/36","display_name":"Health Professions"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T10508","display_name":"Patient Safety and Medication Errors","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2739","display_name":"Public Health, Environmental and Occupational Health"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/alarm-fatigue","display_name":"alarm fatigue","score":0.9980000257492065},{"id":"https://openalex.org/keywords/alarm-suppression","display_name":"alarm suppression","score":0.7310000061988831},{"id":"https://openalex.org/keywords/context-aware-design","display_name":"context-sensitive design","score":0.656000018119812},{"id":"https://openalex.org/keywords/safety-constraints","display_name":"safety constraints","score":0.7129999995231628},{"id":"https://openalex.org/keywords/clinical-alarms","display_name":"clinical alarm systems","score":0.6899999976158142},{"id":"https://openalex.org/keywords/patient-safety","display_name":"patient safety","score":0.5849999785423279},{"id":"https://openalex.org/keywords/clinical-decision-support","display_name":"clinical decision support","score":0.531000018119812}],"concepts":[{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.45419999957084656},{"id":"https://openalex.org/C2779119184","wikidata":"https://www.wikidata.org/wiki/Q294350","display_name":"ALARM","level":2,"score":0.427700012922287},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.3765000104904175},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.34549999237060547},{"id":"https://openalex.org/C168167062","wikidata":"https://www.wikidata.org/wiki/Q1117970","display_name":"Component (thermodynamics)","level":2,"score":0.2782999873161316},{"id":"https://openalex.org/C194305327","wikidata":"https://www.wikidata.org/wiki/Q1022253","display_name":"Manual fire alarm activation","level":3,"score":0.24719999730587006},{"id":"https://openalex.org/C99498987","wikidata":"https://www.wikidata.org/wiki/Q2210247","display_name":"Noise (video)","level":3,"score":0.24529999494552612},{"id":"https://openalex.org/C26517878","wikidata":"https://www.wikidata.org/wiki/Q228039","display_name":"Key (lock)","level":2,"score":0.23759999871253967},{"id":"https://openalex.org/C112930515","wikidata":"https://www.wikidata.org/wiki/Q4389547","display_name":"Risk analysis (engineering)","level":1,"score":0.2362000048160553},{"id":"https://openalex.org/C2780791683","wikidata":"https://www.wikidata.org/wiki/Q846785","display_name":"Action (physics)","level":2,"score":0.22990000247955322}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.68159/h030651861","doi":"https://doi.org/10.68159/h030651861","is_oa":true,"landing_page_url":"https://doi.org/10.68159/h030651861","pdf_url":"https://cirpublications.com/storage/pub-article-files/article-h030651861.pdf?ts=1788793279","source":{"id":"https://openalex.org/S7407064685","display_name":"Journal of Health Informatics and Digital Systems","issn_l":"3149-8973","issn":["3149-8973"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":"cc-by-nc-sa","license_id":"https://openalex.org/licenses/cc-by-nc-sa","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Journal of Health Informatics and Digital Systems","raw_type":"journal-article"}],"best_oa_location":{"id":"doi:10.68159/h030651861","doi":"https://doi.org/10.68159/h030651861","is_oa":true,"landing_page_url":"https://doi.org/10.68159/h030651861","pdf_url":"https://cirpublications.com/storage/pub-article-files/article-h030651861.pdf?ts=1788793279","source":{"id":"https://openalex.org/S7407064685","display_name":"Journal of Health Informatics and Digital Systems","issn_l":"3149-8973","issn":["3149-8973"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":"cc-by-nc-sa","license_id":"https://openalex.org/licenses/cc-by-nc-sa","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Journal of Health Informatics and Digital Systems","raw_type":"journal-article"},"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/3","display_name":"Good health and well-being","score":0.6240000128746033}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":true,"pdf":true},"content_urls":{"pdf":"https://content.openalex.org/works/W7211908111.pdf","grobid_xml":"https://content.openalex.org/works/W7211908111.grobid-xml"},"referenced_works_count":29,"referenced_works":["https://openalex.org/W2510044447","https://openalex.org/W2795366269","https://openalex.org/W2807152379","https://openalex.org/W2884449598","https://openalex.org/W2902050969","https://openalex.org/W2929458269","https://openalex.org/W2962843063","https://openalex.org/W2964979747","https://openalex.org/W2979391928","https://openalex.org/W2990473145","https://openalex.org/W3048898282","https://openalex.org/W3101848621","https://openalex.org/W3128926672","https://openalex.org/W3171672053","https://openalex.org/W4221083181","https://openalex.org/W4282601654","https://openalex.org/W4362475600","https://openalex.org/W4380270945","https://openalex.org/W4386261738","https://openalex.org/W4388451292","https://openalex.org/W4388850972","https://openalex.org/W4394573496","https://openalex.org/W4402895140","https://openalex.org/W4405168559","https://openalex.org/W4408026487","https://openalex.org/W4409358713","https://openalex.org/W4409902907","https://openalex.org/W4411492992","https://openalex.org/W4414773521"],"related_works":["https://openalex.org/W4242247164","https://openalex.org/W2423777416","https://openalex.org/W4366394242","https://openalex.org/W7211878493","https://openalex.org/W2595730337","https://openalex.org/W2409559494","https://openalex.org/W2274966415","https://openalex.org/W205804704","https://openalex.org/W2105707930","https://openalex.org/W6885162822"],"abstract_inverted_index":{"Alarm":[0],"fatigue":[1,29],"in":[2,142,174],"healthcare":[3,162],"settings":[4],"poses":[5],"significant":[6],"risks":[7],"to":[8,37,64,184],"patient":[9,75,186],"safety,":[10],"arising":[11],"from":[12,44],"excessive,":[13],"non-actionable":[14],"alerts":[15],"that":[16],"desensitize":[17],"clinicians.":[18],"This":[19,155],"conceptual":[20,158],"manuscript":[21],"introduces":[22],"a":[23,60,102,106,150],"novel":[24],"framework":[25,83],"for":[26,87,118,160,171,180],"mitigating":[27],"alarm":[28,182],"through":[30],"context-aware":[31,56],"suppression":[32,57,91,107,126],"mechanisms,":[33],"while":[34],"rigorously":[35],"adhering":[36],"safety":[38,112],"constraints.":[39,131],"Drawing":[40],"on":[41,69],"theoretical":[42],"principles":[43],"systems":[45],"engineering,":[46],"human":[47],"factors,":[48,78],"and":[49,79,114,127,149,167,188],"artificial":[50],"intelligence,":[51],"we":[52,136],"propose":[53],"the":[54,178],"safety-integrated":[55],"topology":[58],"(SICAST),":[59],"multi-layered":[61],"architecture":[62],"designed":[63],"dynamically":[65],"filter":[66],"alarms":[67],"based":[68],"real-time":[70],"contextual":[71,153],"data":[72],"such":[73,145],"as":[74,146],"physiology,":[76],"environmental":[77],"clinician":[80,190],"workload.":[81],"The":[82],"incorporates":[84],"feedback":[85],"loops":[86],"continuous":[88],"adaptation,":[89],"ensuring":[90],"decisions":[92],"prioritize":[93],"risk":[94,123],"minimization":[95],"without":[96],"compromising":[97],"vigilance.":[98],"Key":[99],"components":[100],"include":[101],"context":[103],"aggregation":[104],"layer,":[105],"decision":[108,128],"engine":[109],"governed":[110],"by":[111],"thresholds,":[113],"an":[115],"audit":[116],"trail":[117],"governance.":[119],"Interpretive":[120],"formulas":[121],"model":[122],"propagation":[124],"under":[125],"confidence":[129],"amid":[130],"By":[132],"synthesizing":[133],"recent":[134],"literature,":[135],"highlight":[137],"how":[138],"SICAST":[139],"addresses":[140],"gaps":[141],"existing":[143],"approaches,":[144],"static":[147],"thresholding":[148],"lack":[151],"of":[152],"integration.":[154],"work":[156],"advances":[157],"designs":[159],"AI-driven":[161],"systems,":[163],"emphasizing":[164],"infrastructural":[165],"resilience":[166],"ethical":[168],"deployment.":[169],"Implications":[170],"system":[172],"orchestration":[173],"critical":[175],"care":[176],"underscore":[177],"need":[179],"balanced":[181],"management":[183],"enhance":[185],"outcomes":[187],"reduce":[189],"burden.":[191]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W7211908111","counts_by_year":[],"updated_date":"2026-11-22T12:46:00.618207","created_date":"2026-09-08T00:00:00"}