{"id":"https://openalex.org/W7210285653","doi":"https://doi.org/10.65405/vwcfnp63","title":"A Comparative Machine Learning Algorithms for Integrated Structural Health Monitoring in Smart Infrastructure maintenance and predication","display_name":"A Comparative Machine Learning Algorithms for Integrated Structural Health Monitoring in Smart Infrastructure maintenance and predication","publication_year":2026,"publication_date":"2026-09-06","ids":{"openalex":"https://openalex.org/W7210285653","doi":"https://doi.org/10.65405/vwcfnp63"},"language":"en","primary_location":{"id":"doi:10.65405/vwcfnp63","doi":"https://doi.org/10.65405/vwcfnp63","is_oa":true,"landing_page_url":"https://doi.org/10.65405/vwcfnp63","pdf_url":"https://afjs.histr.edu.ly/index.php/afjs/article/download/767/691","source":{"id":"https://openalex.org/S7407058654","display_name":"Al-Farooq Journal of Sciences","issn_l":"3135-2359","issn":["3135-2359"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Al-Farooq Journal of Sciences","raw_type":"journal-article"},"volume":null,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"hybrid","oa_url":"https://afjs.histr.edu.ly/index.php/afjs/article/download/767/691","any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5120532860","display_name":"Mohamed Ali Mohamed EL-sseid","orcid":"https://orcid.org/0009-0007-1307-8623","observed_orcids":["https://orcid.org/0009-0007-1307-8623"]},"institutions":[{"id":"https://openalex.org/I4387152199","display_name":"Ankara Bilim \u00dcniversitesi","ror":"https://ror.org/041vwqc20","country_code":"TR","type":"education","lineage":["https://openalex.org/I4387152199"]}],"countries":["TR"],"is_corresponding":false,"raw_author_name":"Mohamed EL-sseid","raw_affiliation_strings":["Department of Software Engineering, Ankara Bilim University, T\u00fcrkiye"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Software Engineering, Ankara Bilim University, T\u00fcrkiye","institution_ids":["https://openalex.org/I4387152199"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5095652383","display_name":"L.O.F. Ben Dalla","orcid":"https://orcid.org/0009-0008-7624-7567","observed_orcids":["https://orcid.org/0009-0008-7624-7567"]},"institutions":[{"id":"https://openalex.org/I4405259189","display_name":"Higher Institute of Science and Technology Tajoura","ror":"https://ror.org/01wbvvd76","country_code":"LY","type":"education","lineage":["https://openalex.org/I4405259189"]}],"countries":["LY"],"is_corresponding":false,"raw_author_name":"Llahm Ben Dalla","raw_affiliation_strings":["Computer Engineering department, Higher institute of Sciences and Technology Tajoura, , Libya"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Computer Engineering department, Higher institute of Sciences and Technology Tajoura, , Libya","institution_ids":["https://openalex.org/I4405259189"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5150539542","display_name":"Tasnem ELsseid","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4387152199","display_name":"Ankara Bilim \u00dcniversitesi","ror":"https://ror.org/041vwqc20","country_code":"TR","type":"education","lineage":["https://openalex.org/I4387152199"]}],"countries":["TR"],"is_corresponding":false,"raw_author_name":"Tasnem ELsseid","raw_affiliation_strings":["Department of computer  Engineering, Ankara Bilim University, T\u00fcrkiye"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of computer  Engineering, Ankara Bilim University, T\u00fcrkiye","institution_ids":["https://openalex.org/I4387152199"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5112886563","display_name":"Mansour Essgaer","orcid":"https://orcid.org/0000-0002-8447-5091","observed_orcids":["https://orcid.org/0000-0002-8447-5091"]},"institutions":[{"id":"https://openalex.org/I153265617","display_name":"Sebha University","ror":"https://ror.org/04m1ha467","country_code":"LY","type":"education","lineage":["https://openalex.org/I153265617"]}],"countries":["LY"],"is_corresponding":false,"raw_author_name":"Mansour Essgaer","raw_affiliation_strings":["Artificial Intelligence Department, Faculty of Information Technology, Sebha University, Sabha, Libya"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Artificial Intelligence Department, Faculty of Information Technology, Sebha University, Sabha, Libya","institution_ids":["https://openalex.org/I153265617"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5126517608","display_name":"Abdulgader Alsharif","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I153265617","display_name":"Sebha University","ror":"https://ror.org/04m1ha467","country_code":"LY","type":"education","lineage":["https://openalex.org/I153265617"]}],"countries":["LY"],"is_corresponding":false,"raw_author_name":"Abdulgader Alsharif","raw_affiliation_strings":["Department of Electric and Electronic Engineering, College of Technical Sciences Sebha, Libya"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Electric and Electronic Engineering, College of Technical Sciences Sebha, Libya","institution_ids":["https://openalex.org/I153265617"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5150463147","display_name":"Fatma Mohammed Ali","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Fatma Mohammed Ali","raw_affiliation_strings":["Department of Computer Sciences,Faculty of Information Technology, Benghazi, Libya"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Computer Sciences,Faculty of Information Technology, Benghazi, Libya","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5150534872","display_name":"Mohammed Alarafi","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Mohammed Alarafi","raw_affiliation_strings":["Electrical and Electronics Engineering Department, Faculty of Engineering Benghazi, Libya"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Electrical and Electronics Engineering Department, Faculty of Engineering Benghazi, Libya","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5008843412","display_name":"Asma Agaal","orcid":"https://orcid.org/0000-0002-8687-2605","observed_orcids":["https://orcid.org/0000-0002-8687-2605"]},"institutions":[{"id":"https://openalex.org/I4405284835","display_name":"College of Technical Sciences - Sabha","ror":"https://ror.org/049edyw11","country_code":"LY","type":"education","lineage":["https://openalex.org/I4405284835"]}],"countries":["LY"],"is_corresponding":false,"raw_author_name":"Asma Agaal","raw_affiliation_strings":["Department of Computer Sciences,Faculty of Technical Sciences, Sabha,Libya, Sabha"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Department of Computer Sciences,Faculty of Technical Sciences, Sabha,Libya, Sabha","institution_ids":["https://openalex.org/I4405284835"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5136101804","display_name":"Ayyah Mustafa Salih","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4405264338","display_name":"College of Electrical and Electronics Technology","ror":"https://ror.org/01mg2ny21","country_code":"LY","type":"education","lineage":["https://openalex.org/I4405264338"]}],"countries":["LY"],"is_corresponding":false,"raw_author_name":"Ayyah Mustafa Salih","raw_affiliation_strings":["Faculty of Engineering, College of Electrical and Electronic Technology-Benghazi, Benghazi, Libya"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Faculty of Engineering, College of Electrical and Electronic Technology-Benghazi, Benghazi, Libya","institution_ids":["https://openalex.org/I4405264338"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":5,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":true,"cited_by_count":0,"citation_normalized_percentile":{"value":0.0,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"2","issue":"4","first_page":"165","last_page":"182"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10534","display_name":"Structural Health Monitoring Techniques","score":0.9990000128746033,"subfield":{"id":"https://openalex.org/subfields/2205","display_name":"Civil and Structural Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10534","display_name":"Structural Health Monitoring Techniques","score":0.9990000128746033,"subfield":{"id":"https://openalex.org/subfields/2205","display_name":"Civil and Structural Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11606","display_name":"Infrastructure Maintenance and Monitoring","score":0.000699999975040555,"subfield":{"id":"https://openalex.org/subfields/2205","display_name":"Civil and Structural Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10220","display_name":"Machine Fault Diagnosis Techniques","score":9.999999747378752e-05,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/structural-health-monitoring","display_name":"structural health monitoring","score":0.9919999837875366},{"id":"https://openalex.org/keywords/predictive-maintenance","display_name":"predictive maintenance","score":0.9890000224113464},{"id":"https://openalex.org/keywords/smart-infrastructure","display_name":"smart infrastructure","score":0.9679999947547913},{"id":"https://openalex.org/keywords/multimodal-sensor-data","display_name":"multimodal sensor data","score":0.8069999814033508},{"id":"https://openalex.org/keywords/vibration-signatures","display_name":"vibration signatures","score":0.7789999842643738},{"id":"https://openalex.org/keywords/bridge-deck","display_name":"bridge deck","score":0.7519999742507935},{"id":"https://openalex.org/keywords/substation-transformers","display_name":"substation transformers","score":0.9079999923706055},{"id":"https://openalex.org/keywords/load-forecasting","display_name":"load forecasting","score":0.9629999995231628},{"id":"https://openalex.org/keywords/structural-damage-classification","display_name":"structural damage classification","score":0.8980000019073486},{"id":"https://openalex.org/keywords/xgboost","display_name":"XGBoost","score":0.753000020980835},{"id":"https://openalex.org/keywords/random-forest","display_name":"random forest","score":0.9139999747276306},{"id":"https://openalex.org/keywords/support-vector-machine","display_name":"support vector machine","score":0.9860000014305115},{"id":"https://openalex.org/keywords/lstm","display_name":"LSTM","score":0.7820000052452087},{"id":"https://openalex.org/keywords/edge-deployment","display_name":"edge deployment","score":0.8109999895095825},{"id":"https://openalex.org/keywords/internet-of-things","display_name":"Internet of Things","score":0.6119999885559082},{"id":"https://openalex.org/keywords/smart-cities","display_name":"smart cities","score":0.5799999833106995}],"concepts":[{"id":"https://openalex.org/C2776247918","wikidata":"https://www.wikidata.org/wiki/Q1423713","display_name":"Structural health monitoring","level":2,"score":0.661899983882904},{"id":"https://openalex.org/C12267149","wikidata":"https://www.wikidata.org/wiki/Q282453","display_name":"Support vector machine","level":2,"score":0.6376000046730042},{"id":"https://openalex.org/C119857082","wikidata":"https://www.wikidata.org/wiki/Q2539","display_name":"Machine learning","level":1,"score":0.614300012588501},{"id":"https://openalex.org/C169258074","wikidata":"https://www.wikidata.org/wiki/Q245748","display_name":"Random forest","level":2,"score":0.5978999733924866},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5898000001907349},{"id":"https://openalex.org/C154945302","wikidata":"https://www.wikidata.org/wiki/Q11660","display_name":"Artificial intelligence","level":1,"score":0.491100013256073},{"id":"https://openalex.org/C2777303404","wikidata":"https://www.wikidata.org/wiki/Q759757","display_name":"Convergence (economics)","level":2,"score":0.4909000098705292},{"id":"https://openalex.org/C2994238195","wikidata":"https://www.wikidata.org/wiki/Q121359","display_name":"Civil infrastructure","level":2,"score":0.4580000042915344},{"id":"https://openalex.org/C11413529","wikidata":"https://www.wikidata.org/wiki/Q8366","display_name":"Algorithm","level":1,"score":0.4383000135421753},{"id":"https://openalex.org/C70452415","wikidata":"https://www.wikidata.org/wiki/Q3182448","display_name":"Predictive maintenance","level":2,"score":0.4083000123500824},{"id":"https://openalex.org/C2775846686","wikidata":"https://www.wikidata.org/wiki/Q643012","display_name":"Condition monitoring","level":2,"score":0.3953000009059906},{"id":"https://openalex.org/C110083411","wikidata":"https://www.wikidata.org/wiki/Q1744628","display_name":"Statistical classification","level":2,"score":0.36469998955726624},{"id":"https://openalex.org/C81860439","wikidata":"https://www.wikidata.org/wiki/Q251212","display_name":"Internet of Things","level":2,"score":0.36419999599456787},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.36329999566078186},{"id":"https://openalex.org/C75684735","wikidata":"https://www.wikidata.org/wiki/Q858810","display_name":"Big data","level":2,"score":0.3172999918460846},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.31119999289512634},{"id":"https://openalex.org/C40293303","wikidata":"https://www.wikidata.org/wiki/Q27137","display_name":"Electric power","level":3,"score":0.3059999942779541},{"id":"https://openalex.org/C45942800","wikidata":"https://www.wikidata.org/wiki/Q245652","display_name":"Ensemble learning","level":2,"score":0.3041999936103821},{"id":"https://openalex.org/C77715397","wikidata":"https://www.wikidata.org/wiki/Q931447","display_name":"Electrical load","level":3,"score":0.3019999861717224},{"id":"https://openalex.org/C170777988","wikidata":"https://www.wikidata.org/wiki/Q2316331","display_name":"Electric power industry","level":3,"score":0.2928999960422516},{"id":"https://openalex.org/C124101348","wikidata":"https://www.wikidata.org/wiki/Q172491","display_name":"Data mining","level":1,"score":0.2913999855518341},{"id":"https://openalex.org/C50644808","wikidata":"https://www.wikidata.org/wiki/Q192776","display_name":"Artificial neural network","level":2,"score":0.2842000126838684},{"id":"https://openalex.org/C24590314","wikidata":"https://www.wikidata.org/wiki/Q336038","display_name":"Wireless sensor network","level":2,"score":0.28220000863075256},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.27900001406669617},{"id":"https://openalex.org/C162175671","wikidata":"https://www.wikidata.org/wiki/Q3749263","display_name":"Electrical equipment","level":2,"score":0.26159998774528503}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.65405/vwcfnp63","doi":"https://doi.org/10.65405/vwcfnp63","is_oa":true,"landing_page_url":"https://doi.org/10.65405/vwcfnp63","pdf_url":"https://afjs.histr.edu.ly/index.php/afjs/article/download/767/691","source":{"id":"https://openalex.org/S7407058654","display_name":"Al-Farooq Journal of Sciences","issn_l":"3135-2359","issn":["3135-2359"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Al-Farooq Journal of Sciences","raw_type":"journal-article"}],"best_oa_location":{"id":"doi:10.65405/vwcfnp63","doi":"https://doi.org/10.65405/vwcfnp63","is_oa":true,"landing_page_url":"https://doi.org/10.65405/vwcfnp63","pdf_url":"https://afjs.histr.edu.ly/index.php/afjs/article/download/767/691","source":{"id":"https://openalex.org/S7407058654","display_name":"Al-Farooq Journal of Sciences","issn_l":"3135-2359","issn":["3135-2359"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Al-Farooq Journal of Sciences","raw_type":"journal-article"},"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/9","score":1.0,"display_name":"Industry, innovation and infrastructure"},{"id":"https://metadata.un.org/sdg/11","score":0.5142999887466431,"display_name":"Sustainable cities and communities"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":true,"grobid_xml":true},"content_urls":{"pdf":"https://content.openalex.org/works/W7210285653.pdf","grobid_xml":"https://content.openalex.org/works/W7210285653.grobid-xml"},"referenced_works_count":17,"referenced_works":["https://openalex.org/W2063810421","https://openalex.org/W3036589474","https://openalex.org/W3106646795","https://openalex.org/W3118161736","https://openalex.org/W3120821924","https://openalex.org/W4295599392","https://openalex.org/W4297990456","https://openalex.org/W4312233062","https://openalex.org/W4385586270","https://openalex.org/W4386014884","https://openalex.org/W4406698083","https://openalex.org/W7108227654","https://openalex.org/W7133508157","https://openalex.org/W7134138541","https://openalex.org/W7161110452","https://openalex.org/W7161153591","https://openalex.org/W7221148150"],"related_works":["https://openalex.org/W4379911278","https://openalex.org/W3045530378","https://openalex.org/W7216804761","https://openalex.org/W3183660758","https://openalex.org/W4407590334","https://openalex.org/W7215130194","https://openalex.org/W2954225798","https://openalex.org/W7161004666","https://openalex.org/W4415292492","https://openalex.org/W4411707073"],"abstract_inverted_index":{"The":[0],"convergence":[1],"of":[2,49,112,131],"civil":[3,82,159],"infrastructure":[4,169],"and":[5,31,66,86,160],"electrical":[6,106,161],"power":[7],"systems":[8],"within":[9],"smart":[10,168],"city":[11],"frameworks":[12],"necessitates":[13],"robust,":[14],"cross-domain":[15],"monitoring":[16],"strategies.":[17],"While":[18],"machine":[19],"learning":[20],"(ML)":[21],"has":[22],"shown":[23],"promise":[24],"in":[25,101,105,122,147],"isolated":[26],"Structural":[27],"Health":[28],"Monitoring":[29],"(SHM)":[30],"Predictive":[32],"Maintenance":[33],"(PdM),":[34],"comparative":[35,47],"evaluations":[36],"across":[37],"both":[38],"domains":[39],"remain":[40],"fragmented.":[41],"This":[42,151],"study":[43],"presents":[44],"a":[45,75,154],"comprehensive":[46],"analysis":[48],"four":[50],"prominent":[51],"ML":[52,164],"algorithms":[53],"Random":[54],"Forest":[55],"(RF),":[56],"Support":[57],"Vector":[58],"Machines":[59],"(SVM),":[60],"Long":[61],"Short-Term":[62],"Memory":[63],"(LSTM)":[64],"networks,":[65],"XGBoost":[67],"applied":[68],"to":[69],"multimodal":[70],"sensor":[71],"data.":[72],"We":[73],"utilized":[74],"synthesized":[76],"dataset":[77],"comprising":[78],"vibration":[79,128],"signatures":[80],"from":[81,90,126],"structures":[83],"(bridge":[84],"decks)":[85],"thermal-electrical":[87],"load":[88,107],"profiles":[89],"substation":[91],"transformers.":[92],"Our":[93],"findings":[94],"indicate":[95],"that":[96],"while":[97],"LSTM":[98],"networks":[99],"excel":[100],"capturing":[102],"temporal":[103],"dependencies":[104],"forecasting":[108],"(achieving":[109],"an":[110],"F1-score":[111],"0.94),":[113],"tree-based":[114],"ensemble":[115],"methods,":[116],"specifically":[117],"XGBoost,":[118],"demonstrate":[119],"superior":[120],"efficacy":[121],"classifying":[123],"structural":[124],"damage":[125],"high-dimensional":[127],"features":[129],"(accuracy":[130],"96.2%).":[132],"Furthermore,":[133],"RF":[134],"offered":[135],"the":[136],"most":[137],"computationally":[138],"efficient":[139],"inference,":[140],"making":[141],"it":[142],"highly":[143],"suitable":[144],"for":[145,158,166],"edge-deployment":[146],"resource-constrained":[148],"IoT":[149],"nodes.":[150],"paper":[152],"provides":[153],"practical":[155],"decision-making":[156],"framework":[157],"engineers":[162],"selecting":[163],"architectures":[165],"integrated":[167],"monitoring.":[170]},"counts_by_year":[],"updated_date":"2026-11-04T10:54:05.112534","created_date":"2026-09-07T00:00:00"}
