{"id":"https://openalex.org/W7208814866","doi":"https://doi.org/10.1016/j.csite.2026.108489","title":"Comparative study on thermal and economic performance of ground source heat pump systems utilizing vertical versus horizontal ground heat exchangers for building heating and cooling","display_name":"Comparative study on thermal and economic performance of ground source heat pump systems utilizing vertical versus horizontal ground heat exchangers for building heating and cooling","publication_year":2026,"publication_date":"2026-09-05","ids":{"openalex":"https://openalex.org/W7208814866","doi":"https://doi.org/10.1016/j.csite.2026.108489"},"language":"en","primary_location":{"id":"doi:10.1016/j.csite.2026.108489","doi":"https://doi.org/10.1016/j.csite.2026.108489","is_oa":true,"landing_page_url":"https://doi.org/10.1016/j.csite.2026.108489","pdf_url":"https://www.sciencedirect.com/science/article/pii/S2214157X2600852X/pdf","source":{"id":"https://openalex.org/S2764363796","display_name":"Case Studies in Thermal Engineering","issn_l":"2214-157X","issn":["2214-157X"],"is_oa":true,"is_in_doaj":true,"is_core":true,"listed_in":["cwts-core","doaj","dongbi-b","jufo-1","norway-1","oarl","poland-70"],"host_organization":"https://openalex.org/P4310320990","host_organization_name":"Elsevier BV","host_organization_lineage":["https://openalex.org/P4310320990"],"host_organization_lineage_names":["Elsevier BV"],"type":"journal"},"license":"cc-by-nc","license_id":"https://openalex.org/licenses/cc-by-nc","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Case Studies in Thermal Engineering","raw_type":"journal-article"},"volume":null,"type":"article","is_traditional":true,"indexed_in":["crossref","doaj"],"open_access":{"is_oa":true,"oa_status":"gold","oa_url":"https://www.sciencedirect.com/science/article/pii/S2214157X2600852X/pdf","any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5150291642","display_name":"Kun Zhou","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4210163363","display_name":"PLA Army Engineering University","ror":"https://ror.org/05mgp8x93","country_code":"CN","type":"education","lineage":["https://openalex.org/I4210163363"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Kun Zhou","raw_affiliation_strings":["Army Engineering University of PLA, Nanjing, 210007, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Army Engineering University of PLA, Nanjing, 210007, China","institution_ids":["https://openalex.org/I4210163363"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5025992841","display_name":"Kun Zhou","orcid":"https://orcid.org/0000-0002-4529-8598","observed_orcids":["https://orcid.org/0000-0002-4529-8598"]},"institutions":[{"id":"https://openalex.org/I4210163363","display_name":"PLA Army Engineering University","ror":"https://ror.org/05mgp8x93","country_code":"CN","type":"education","lineage":["https://openalex.org/I4210163363"]}],"countries":["CN"],"is_corresponding":true,"raw_author_name":"Yong Li","raw_affiliation_strings":["Army Engineering University of PLA, Nanjing, 210007, China"],"raw_orcid":"https://orcid.org/0000-0002-4529-8598","affiliations":[{"raw_affiliation_string":"Army Engineering University of PLA, Nanjing, 210007, China","institution_ids":["https://openalex.org/I4210163363"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5150190123","display_name":"Zhiliang Cui","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4210163363","display_name":"PLA Army Engineering University","ror":"https://ror.org/05mgp8x93","country_code":"CN","type":"education","lineage":["https://openalex.org/I4210163363"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Zhiliang Cui","raw_affiliation_strings":["Army Engineering University of PLA, Nanjing, 210007, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Army Engineering University of PLA, Nanjing, 210007, China","institution_ids":["https://openalex.org/I4210163363"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5052467166","display_name":"Chenglin LI","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4210163363","display_name":"PLA Army Engineering University","ror":"https://ror.org/05mgp8x93","country_code":"CN","type":"education","lineage":["https://openalex.org/I4210163363"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Chenglin Li","raw_affiliation_strings":["Army Engineering University of PLA, Nanjing, 210007, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Army Engineering University of PLA, Nanjing, 210007, China","institution_ids":["https://openalex.org/I4210163363"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5136624222","display_name":"Mingzhou Xia","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4210163363","display_name":"PLA Army Engineering University","ror":"https://ror.org/05mgp8x93","country_code":"CN","type":"education","lineage":["https://openalex.org/I4210163363"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Mingzhou Xia","raw_affiliation_strings":["Army Engineering University of PLA, Nanjing, 210007, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Army Engineering University of PLA, Nanjing, 210007, China","institution_ids":["https://openalex.org/I4210163363"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5150315624","display_name":"Zengxi Li","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4210163363","display_name":"PLA Army Engineering University","ror":"https://ror.org/05mgp8x93","country_code":"CN","type":"education","lineage":["https://openalex.org/I4210163363"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Zengxi Li","raw_affiliation_strings":["Army Engineering University of PLA, Nanjing, 210007, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Army Engineering University of PLA, Nanjing, 210007, China","institution_ids":["https://openalex.org/I4210163363"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":["https://openalex.org/A5025992841"],"corresponding_institution_ids":["https://openalex.org/I4210163363"],"apc_list":{"value":1620,"currency":"USD","value_usd":1620},"apc_paid":{"value":1620,"currency":"USD","value_usd":1620},"fwci":0.0,"has_fulltext":true,"cited_by_count":0,"citation_normalized_percentile":{"value":0.0,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"86","issue":null,"first_page":"108489","last_page":"108489"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11225","display_name":"Geothermal Energy Systems and Applications","score":0.9965999722480774,"subfield":{"id":"https://openalex.org/subfields/2105","display_name":"Renewable Energy, Sustainability and the Environment"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11225","display_name":"Geothermal Energy Systems and Applications","score":0.9965999722480774,"subfield":{"id":"https://openalex.org/subfields/2105","display_name":"Renewable Energy, Sustainability and the Environment"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11185","display_name":"Integrated Energy Systems Optimization","score":0.0015999999595806003,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.00039999998989515007,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/ground-source-heat-pump","display_name":"ground source heat pump","score":0.9319999814033508},{"id":"https://openalex.org/keywords/horizontal-ground-heat-exchanger","display_name":"horizontal ground heat exchanger","score":0.9490000009536743},{"id":"https://openalex.org/keywords/building-heating-and-cooling","display_name":"building heating and cooling","score":0.9089999794960022},{"id":"https://openalex.org/keywords/techno-economic-analysis","display_name":"techno-economic analysis","score":0.7409999966621399},{"id":"https://openalex.org/keywords/levelized-cost-of-electricity","display_name":"levelized cost of electricity","score":0.9779999852180481},{"id":"https://openalex.org/keywords/coefficient-of-performance","display_name":"coefficient of performance","score":0.9470000267028809},{"id":"https://openalex.org/keywords/unsaturated-soil","display_name":"unsaturated soil","score":0.7009999752044678},{"id":"https://openalex.org/keywords/ground-heat-exchanger-design","display_name":"ground heat exchanger design","score":0.781000018119812},{"id":"https://openalex.org/keywords/drilling-costs","display_name":"drilling costs","score":0.7139999866485596},{"id":"https://openalex.org/keywords/payback-period","display_name":"payback period","score":0.6869999766349792},{"id":"https://openalex.org/keywords/sensitivity-analysis","display_name":"sensitivity analysis","score":0.6949999928474426}],"concepts":[{"id":"https://openalex.org/C2776461528","wikidata":"https://www.wikidata.org/wiki/Q131313","display_name":"Heat pump","level":3,"score":0.7594000101089478},{"id":"https://openalex.org/C107706546","wikidata":"https://www.wikidata.org/wiki/Q189124","display_name":"Heat exchanger","level":2,"score":0.66839998960495},{"id":"https://openalex.org/C204530211","wikidata":"https://www.wikidata.org/wiki/Q752823","display_name":"Thermal","level":2,"score":0.5878000259399414},{"id":"https://openalex.org/C187949908","wikidata":"https://www.wikidata.org/wiki/Q2044954","display_name":"Air source heat pumps","level":4,"score":0.5552999973297119},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.5478000044822693},{"id":"https://openalex.org/C116915560","wikidata":"https://www.wikidata.org/wiki/Q83504","display_name":"Nuclear engineering","level":1,"score":0.4717000126838684},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.4691999852657318},{"id":"https://openalex.org/C65473313","wikidata":"https://www.wikidata.org/wiki/Q17007798","display_name":"Copper in heat exchangers","level":5,"score":0.46209999918937683},{"id":"https://openalex.org/C57879066","wikidata":"https://www.wikidata.org/wiki/Q41217","display_name":"Mechanics","level":1,"score":0.4011000096797943},{"id":"https://openalex.org/C32375409","wikidata":"https://www.wikidata.org/wiki/Q261231","display_name":"Plate heat exchanger","level":3,"score":0.3610000014305115},{"id":"https://openalex.org/C13119800","wikidata":"https://www.wikidata.org/wiki/Q902090","display_name":"Coefficient of performance","level":4,"score":0.3321000039577484},{"id":"https://openalex.org/C50517652","wikidata":"https://www.wikidata.org/wiki/Q179635","display_name":"Heat transfer","level":2,"score":0.3215000033378601},{"id":"https://openalex.org/C79795727","wikidata":"https://www.wikidata.org/wiki/Q3068508","display_name":"Passive cooling","level":3,"score":0.305400013923645},{"id":"https://openalex.org/C7694927","wikidata":"https://www.wikidata.org/wiki/Q7667810","display_name":"Water cooling","level":2,"score":0.29899999499320984},{"id":"https://openalex.org/C44044945","wikidata":"https://www.wikidata.org/wiki/Q17028110","display_name":"Hybrid heat","level":4,"score":0.2888999879360199},{"id":"https://openalex.org/C118227150","wikidata":"https://www.wikidata.org/wiki/Q6839192","display_name":"Micro heat exchanger","level":4,"score":0.2870999872684479},{"id":"https://openalex.org/C48632124","wikidata":"https://www.wikidata.org/wiki/Q617088","display_name":"Heat spreader","level":3,"score":0.2816999852657318},{"id":"https://openalex.org/C97355855","wikidata":"https://www.wikidata.org/wiki/Q11473","display_name":"Thermodynamics","level":1,"score":0.2761000096797943},{"id":"https://openalex.org/C39420092","wikidata":"https://www.wikidata.org/wiki/Q17075298","display_name":"Plate fin heat exchanger","level":4,"score":0.27140000462532043},{"id":"https://openalex.org/C129716092","wikidata":"https://www.wikidata.org/wiki/Q912130","display_name":"Internal heating","level":2,"score":0.26249998807907104},{"id":"https://openalex.org/C186937647","wikidata":"https://www.wikidata.org/wiki/Q1796959","display_name":"Heat sink","level":2,"score":0.25609999895095825},{"id":"https://openalex.org/C78762247","wikidata":"https://www.wikidata.org/wiki/Q1273174","display_name":"Petroleum engineering","level":1,"score":0.2529999911785126},{"id":"https://openalex.org/C59218005","wikidata":"https://www.wikidata.org/wiki/Q17027571","display_name":"Horizontal and vertical","level":2,"score":0.25049999356269836}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1016/j.csite.2026.108489","doi":"https://doi.org/10.1016/j.csite.2026.108489","is_oa":true,"landing_page_url":"https://doi.org/10.1016/j.csite.2026.108489","pdf_url":"https://www.sciencedirect.com/science/article/pii/S2214157X2600852X/pdf","source":{"id":"https://openalex.org/S2764363796","display_name":"Case Studies in Thermal Engineering","issn_l":"2214-157X","issn":["2214-157X"],"is_oa":true,"is_in_doaj":true,"is_core":true,"listed_in":["cwts-core","doaj","dongbi-b","jufo-1","norway-1","oarl","poland-70"],"host_organization":"https://openalex.org/P4310320990","host_organization_name":"Elsevier BV","host_organization_lineage":["https://openalex.org/P4310320990"],"host_organization_lineage_names":["Elsevier BV"],"type":"journal"},"license":"cc-by-nc","license_id":"https://openalex.org/licenses/cc-by-nc","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Case Studies in Thermal Engineering","raw_type":"journal-article"},{"id":"pmh:oai:doaj.org/article:3ed85c4a4d9941bfa65856269a8b2b7a","doi":null,"is_oa":false,"landing_page_url":"https://doaj.org/article/3ed85c4a4d9941bfa65856269a8b2b7a","pdf_url":null,"source":{"id":"https://openalex.org/S4306401280","display_name":"DOAJ (DOAJ: Directory of Open Access Journals)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Case Studies in Thermal Engineering, Vol 86, Iss , Pp 108489- (2026)","raw_type":"article"}],"best_oa_location":{"id":"doi:10.1016/j.csite.2026.108489","doi":"https://doi.org/10.1016/j.csite.2026.108489","is_oa":true,"landing_page_url":"https://doi.org/10.1016/j.csite.2026.108489","pdf_url":"https://www.sciencedirect.com/science/article/pii/S2214157X2600852X/pdf","source":{"id":"https://openalex.org/S2764363796","display_name":"Case Studies in Thermal Engineering","issn_l":"2214-157X","issn":["2214-157X"],"is_oa":true,"is_in_doaj":true,"is_core":true,"listed_in":["cwts-core","doaj","dongbi-b","jufo-1","norway-1","oarl","poland-70"],"host_organization":"https://openalex.org/P4310320990","host_organization_name":"Elsevier BV","host_organization_lineage":["https://openalex.org/P4310320990"],"host_organization_lineage_names":["Elsevier BV"],"type":"journal"},"license":"cc-by-nc","license_id":"https://openalex.org/licenses/cc-by-nc","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Case Studies in Thermal Engineering","raw_type":"journal-article"},"sustainable_development_goals":[{"score":0.9090999960899353,"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy"},{"score":0.685699999332428,"id":"https://metadata.un.org/sdg/13","display_name":"Climate action"}],"study_designs":[],"awards":[{"id":"https://openalex.org/G1556243100","display_name":null,"funder_award_id":"52508146","funder_id":"https://openalex.org/F4320321001","funder_display_name":"National Natural Science Foundation of China"}],"funders":[{"id":"https://openalex.org/F4320321001","display_name":"National Natural Science Foundation of China","ror":"https://ror.org/01h0zpd94"}],"has_content":{"grobid_xml":true,"pdf":true},"content_urls":{"pdf":"https://content.openalex.org/works/W7208814866.pdf","grobid_xml":"https://content.openalex.org/works/W7208814866.grobid-xml"},"referenced_works_count":46,"referenced_works":["https://openalex.org/W1963656019","https://openalex.org/W1966475237","https://openalex.org/W1968309451","https://openalex.org/W1969974566","https://openalex.org/W1987950556","https://openalex.org/W1998337343","https://openalex.org/W2009800057","https://openalex.org/W2082661383","https://openalex.org/W2100792479","https://openalex.org/W2144574048","https://openalex.org/W2149695518","https://openalex.org/W2162604832","https://openalex.org/W2253087670","https://openalex.org/W2514500000","https://openalex.org/W2624924060","https://openalex.org/W2780839248","https://openalex.org/W2809345013","https://openalex.org/W2905805155","https://openalex.org/W2917008286","https://openalex.org/W2933110791","https://openalex.org/W2936791031","https://openalex.org/W2945778833","https://openalex.org/W2966575504","https://openalex.org/W2990718650","https://openalex.org/W3035753175","https://openalex.org/W3091148063","https://openalex.org/W3109443126","https://openalex.org/W3113144077","https://openalex.org/W3152688791","https://openalex.org/W3164401185","https://openalex.org/W4235486458","https://openalex.org/W4296251298","https://openalex.org/W4321072180","https://openalex.org/W4387122282","https://openalex.org/W4387229942","https://openalex.org/W4387940936","https://openalex.org/W4388262542","https://openalex.org/W4388530488","https://openalex.org/W4392299599","https://openalex.org/W4408264438","https://openalex.org/W4408489426","https://openalex.org/W4409577610","https://openalex.org/W4410384758","https://openalex.org/W4410974069","https://openalex.org/W4411011648","https://openalex.org/W7118020950"],"related_works":["https://openalex.org/W4386998150","https://openalex.org/W2010238382","https://openalex.org/W3081712511","https://openalex.org/W4296251298","https://openalex.org/W2937017037","https://openalex.org/W3186355438","https://openalex.org/W1899540118","https://openalex.org/W2143931925","https://openalex.org/W7217393041","https://openalex.org/W2049532619"],"abstract_inverted_index":{"This":[0],"study":[1],"presents":[2],"a":[3,72,79,244,254,270,312],"comparative":[4],"evaluation":[5],"of":[6,12,58,99,123,170,203,212,224,246,256,264,272,280,306,315],"the":[7,121,127,132,138,143,209,231,281,303,318,324],"thermal":[8,148,329],"and":[9,23,52,68,75,90,106,149,156,175,186,189,206,219,228,240,269,291,302,308,331],"economic":[10,112,150,332],"performance":[11,129],"two":[13,133],"ground":[14,26],"source":[15],"heat":[16,27,167],"pump":[17,168],"(GSHP)":[18],"systems":[19],"utilizing":[20],"vertical":[21,139,197,282,325],"U-tube":[22],"horizontal":[24,144,195,292,319],"linear-type":[25],"exchangers":[28],"(GHEs).":[29],"A":[30],"high-resolution":[31],"numerical":[32],"model":[33],"was":[34,84],"developed":[35],"to":[36,119,196,287,323],"simulate":[37],"system":[38,141,176,199,283,320,326],"behavior":[39],"under":[40],"realistic":[41],"operating":[42],"conditions,":[43],"incorporating":[44],"annual":[45,154,232],"hourly":[46],"building":[47],"load":[48],"profiles,":[49],"environmental":[50],"fluctuations,":[51],"unsaturated":[53],"soil":[54],"characteristics.":[55],"The":[56,277],"lengths":[57],"both":[59,147,328],"GHE":[60,293],"configurations":[61],"were":[62,116],"determined":[63],"using":[64],"validated":[65],"design":[66],"equations":[67],"analytical":[69],"methods,":[70],"ensuring":[71],"technically":[73],"sound":[74],"non-arbitrary":[76],"comparison.":[77],"Subsequently,":[78],"comprehensive":[80],"techno-economic":[81,96,191],"assessment":[82],"framework":[83],"established,":[85],"integrating":[86],"initial":[87,185,252],"capital,":[88],"operational,":[89],"maintenance":[91],"costs,":[92,253],"along":[93],"with":[94,299],"key":[95],"indicators\u2014levelized":[97],"cost":[98,290],"energy":[100],"(LCoE),":[101],"net":[102],"present":[103],"value":[104],"(NPV),":[105],"payback":[107],"period":[108],"(PP)\u2014to":[109],"rigorously":[110],"evaluate":[111],"efficiency.":[113],"Sensitivity":[114],"analyses":[115],"further":[117],"conducted":[118],"examine":[120],"influence":[122],"input":[124],"parameters":[125],"on":[126],"relative":[128],"gap":[130],"between":[131],"systems.":[134],"Results":[135],"demonstrate":[136],"that":[137],"GSHP":[140,198],"outperforms":[142],"counterpart":[145],"in":[146,160,201,208,230,251,260,267,275,327],"terms,":[151],"exhibiting":[152],"smaller":[153],"variations":[155],"higher":[157],"average":[158,233],"values":[159],"fluid":[161],"outlet":[162],"temperature,":[163],"T":[164,213,234],"f,o":[165,214,235],",":[166,174,180,215,218,222,236,239,243],"coefficient":[169],"performance,":[171],"COP":[172,178,216,220,237,241],"hp":[173,217,238],"COP,":[177],"sys":[179,221,242],"as":[181,183],"well":[182],"lower":[184],"operational":[187],"expenditures":[188],"favorable":[190],"indicators.":[192],"Transitioning":[193],"from":[194],"results":[200],"reductions":[202],"61.96%,":[204],"46.94%,":[205],"9.46%":[207],"fluctuation":[210],"ranges":[211],"increases":[223],"1.48":[225],"\u00b0C,":[226],"0.26,":[227],"0.24":[229,273],"reduction":[245,250,271],"769.31":[247],"Chinese":[248],"Yuan":[249],"decrease":[255],"0.02":[257],"CNY\u00b7kWh":[258],"\u22121":[259],"LCoE,":[261],"an":[262],"increase":[263],"4428.05":[265],"CNY":[266],"NPV,":[268],"year":[274],"PP.":[276],"thermal-economic":[278],"advantage":[279],"is":[284],"inversely":[285],"related":[286],"unit":[288,304],"drilling":[289],"burial":[294,313],"depth,":[295],"while":[296],"positively":[297],"correlated":[298],"interest":[300],"rate":[301],"costs":[305],"excavation":[307],"pipe.":[309],"Even":[310],"at":[311],"depth":[314],"3.00":[316],"m,":[317],"remains":[321],"inferior":[322],"efficiency":[330],"viability.":[333]},"counts_by_year":[],"updated_date":"2026-11-10T11:39:43.021295","created_date":"2026-09-06T00:00:00"}
