{"id":"https://openalex.org/W7204934299","doi":"https://doi.org/10.64388/irev3i5-1722580","title":"Reliability and Integrity Management of Fired Heaters, Boilers and Furnaces in Upstream Oil and Gas: A Review","display_name":"Reliability and Integrity Management of Fired Heaters, Boilers and Furnaces in Upstream Oil and Gas: A Review","alternate_titles":[],"publication_year":2019,"publication_date":"2019-11-30","ids":{"openalex":"https://openalex.org/W7204934299","doi":"https://doi.org/10.64388/irev3i5-1722580"},"language":"en","primary_location":{"id":"doi:10.64388/irev3i5-1722580","doi":"https://doi.org/10.64388/irev3i5-1722580","is_oa":true,"landing_page_url":"https://doi.org/10.64388/irev3i5-1722580","pdf_url":"https://www.irejournals.com/formatedpaper/1722580.pdf","source":{"id":"https://openalex.org/S5407000720","display_name":"Iconic Research and Engineering Journals","issn_l":"2456-8880","issn":["2456-8880"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Iconic Research and Engineering Journals","raw_type":"journal-article"},"parent_works":[],"lineage":["https://openalex.org/W7204934299"],"child_works_count":0,"pull_notice_works":[],"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"bronze","oa_url":"https://www.irejournals.com/formatedpaper/1722580.pdf","any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5150200150","display_name":"Paul Chibuike Obetta","type":null,"orcid":null,"observed_orcids":[]},"acted_on_behalf_of":[],"institutions":[],"countries":[],"is_corresponding":true,"contributor_roles":[],"raw_author_name":"Paul Chibuike Obetta","raw_affiliation_strings":["STIS Nigeria Ltd for TotalEnergies"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"STIS Nigeria Ltd for TotalEnergies","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":["https://openalex.org/A5150200150"],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":3.4445,"has_fulltext":true,"cited_by_count":28,"reviewed_by_count":0,"citation_normalized_percentile":{"value":0.92415404,"is_in_top_1_percent":false,"is_in_top_10_percent":true},"cited_by_percentile_year":{"min":86,"max":99},"biblio":{"volume":"3","issue":"5","first_page":"599","last_page":"626"},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T12086","display_name":"Structural Integrity and Reliability Analysis","score":0.9609000086784363,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T12086","display_name":"Structural Integrity and Reliability Analysis","score":0.9609000086784363,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10780","display_name":"Reliability and Maintenance Optimization","score":0.016499999910593033,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13891","display_name":"Engineering Diagnostics and Reliability","score":0.01080000028014183,"subfield":{"id":"https://openalex.org/subfields/2211","display_name":"Mechanics of Materials"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/fired-heaters","display_name":"fired heaters","score":0.9919999837875366},{"id":"https://openalex.org/keywords/boilers","display_name":"boilers","score":0.9639999866485596},{"id":"https://openalex.org/keywords/furnaces","display_name":"furnaces","score":0.9739999771118164},{"id":"https://openalex.org/keywords/integrity-management","display_name":"integrity management","score":0.8389999866485596},{"id":"https://openalex.org/keywords/reliability","display_name":"reliability","score":0.8460000157356262},{"id":"https://openalex.org/keywords/upstream-oil-and-gas","display_name":"upstream oil and gas","score":0.8830000162124634},{"id":"https://openalex.org/keywords/damage-mechanisms","display_name":"damage mechanisms","score":0.6650000214576721},{"id":"https://openalex.org/keywords/creep","display_name":"creep","score":0.9900000095367432},{"id":"https://openalex.org/keywords/high-temperature-hydrogen-attack","display_name":"high temperature hydrogen attack","score":0.8970000147819519},{"id":"https://openalex.org/keywords/corrosion","display_name":"corrosion","score":0.9580000042915344},{"id":"https://openalex.org/keywords/oxidation","display_name":"oxidation","score":0.7440000176429749},{"id":"https://openalex.org/keywords/carburization","display_name":"carburizing","score":0.9950000047683716},{"id":"https://openalex.org/keywords/thermal-fatigue","display_name":"thermal fatigue","score":0.9980000257492065},{"id":"https://openalex.org/keywords/fouling","display_name":"fouling","score":0.9350000023841858},{"id":"https://openalex.org/keywords/api-579-1-asme-ffs-1","display_name":"API 579-1/ASME FFS-1","score":0.8849999904632568},{"id":"https://openalex.org/keywords/risk-based-inspection","display_name":"risk-based inspection","score":0.8220000267028809},{"id":"https://openalex.org/keywords/fitness-for-service","display_name":"fitness-for-service","score":0.9179999828338623},{"id":"https://openalex.org/keywords/reliability-centered-maintenance","display_name":"reliability-centered maintenance","score":0.996999979019165},{"id":"https://openalex.org/keywords/condition-monitoring","display_name":"condition monitoring","score":0.8240000009536743},{"id":"https://openalex.org/keywords/infrared-thermography","display_name":"infrared thermography","score":0.9440000057220459},{"id":"https://openalex.org/keywords/tube-inspection","display_name":"tube inspection","score":0.7559999823570251},{"id":"https://openalex.org/keywords/digital-twin","display_name":"digital twin","score":0.7720000147819519},{"id":"https://openalex.org/keywords/predictive-analytics","display_name":"predictive analytics","score":0.7789999842643738},{"id":"https://openalex.org/keywords/aging-equipment","display_name":"aging equipment","score":0.6610000133514404},{"id":"https://openalex.org/keywords/offshore-installations","display_name":"offshore installations","score":0.6029999852180481}],"concepts":[{"id":"https://openalex.org/C2780013297","wikidata":"https://www.wikidata.org/wiki/Q19596153","display_name":"Boiler (water heating)","level":2,"score":0.5220999717712402},{"id":"https://openalex.org/C191172861","wikidata":"https://www.wikidata.org/wiki/Q7899321","display_name":"Upstream (networking)","level":2,"score":0.5121999979019165},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.5080000162124634},{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.4839000105857849},{"id":"https://openalex.org/C2777675914","wikidata":"https://www.wikidata.org/wiki/Q6043351","display_name":"Integrity management","level":3,"score":0.41929998993873596},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.4050999879837036},{"id":"https://openalex.org/C548081761","wikidata":"https://www.wikidata.org/wiki/Q180388","display_name":"Waste management","level":1,"score":0.40230000019073486},{"id":"https://openalex.org/C2775846686","wikidata":"https://www.wikidata.org/wiki/Q643012","display_name":"Condition monitoring","level":2,"score":0.3903000056743622},{"id":"https://openalex.org/C2777019822","wikidata":"https://www.wikidata.org/wiki/Q390066","display_name":"Containment (computer programming)","level":2,"score":0.38929998874664307},{"id":"https://openalex.org/C159063594","wikidata":"https://www.wikidata.org/wiki/Q248382","display_name":"Ignition system","level":2,"score":0.3837999999523163},{"id":"https://openalex.org/C105923489","wikidata":"https://www.wikidata.org/wiki/Q133235","display_name":"Combustion","level":2,"score":0.3752000033855438},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.3693999946117401},{"id":"https://openalex.org/C21880701","wikidata":"https://www.wikidata.org/wiki/Q2144042","display_name":"Process engineering","level":1,"score":0.350600004196167},{"id":"https://openalex.org/C115901376","wikidata":"https://www.wikidata.org/wiki/Q184199","display_name":"Automation","level":2,"score":0.3474000096321106},{"id":"https://openalex.org/C78762247","wikidata":"https://www.wikidata.org/wiki/Q1273174","display_name":"Petroleum engineering","level":1,"score":0.34220001101493835},{"id":"https://openalex.org/C109747225","wikidata":"https://www.wikidata.org/wiki/Q815758","display_name":"Scarcity","level":2,"score":0.3391000032424927},{"id":"https://openalex.org/C526740375","wikidata":"https://www.wikidata.org/wiki/Q862571","display_name":"Petroleum industry","level":2,"score":0.3192000091075897},{"id":"https://openalex.org/C107706546","wikidata":"https://www.wikidata.org/wiki/Q189124","display_name":"Heat exchanger","level":2,"score":0.31520000100135803},{"id":"https://openalex.org/C68189081","wikidata":"https://www.wikidata.org/wiki/Q12748","display_name":"Fossil fuel","level":2,"score":0.31380000710487366},{"id":"https://openalex.org/C548895740","wikidata":"https://www.wikidata.org/wiki/Q22656","display_name":"Petroleum","level":2,"score":0.2793999910354614},{"id":"https://openalex.org/C77595967","wikidata":"https://www.wikidata.org/wiki/Q3151013","display_name":"Forensic engineering","level":1,"score":0.2775999903678894},{"id":"https://openalex.org/C2776364302","wikidata":"https://www.wikidata.org/wiki/Q1845437","display_name":"Oil field","level":2,"score":0.2653000056743622},{"id":"https://openalex.org/C98045186","wikidata":"https://www.wikidata.org/wiki/Q205663","display_name":"Process (computing)","level":2,"score":0.26499998569488525},{"id":"https://openalex.org/C66283442","wikidata":"https://www.wikidata.org/wiki/Q1389268","display_name":"Failure mode and effects analysis","level":2,"score":0.2646999955177307},{"id":"https://openalex.org/C82576440","wikidata":"https://www.wikidata.org/wiki/Q214199","display_name":"Fuel oil","level":2,"score":0.26429998874664307}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.64388/irev3i5-1722580","doi":"https://doi.org/10.64388/irev3i5-1722580","is_oa":true,"landing_page_url":"https://doi.org/10.64388/irev3i5-1722580","pdf_url":"https://www.irejournals.com/formatedpaper/1722580.pdf","source":{"id":"https://openalex.org/S5407000720","display_name":"Iconic Research and Engineering Journals","issn_l":"2456-8880","issn":["2456-8880"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Iconic Research and Engineering Journals","raw_type":"journal-article"}],"best_oa_location":{"id":"doi:10.64388/irev3i5-1722580","doi":"https://doi.org/10.64388/irev3i5-1722580","is_oa":true,"landing_page_url":"https://doi.org/10.64388/irev3i5-1722580","pdf_url":"https://www.irejournals.com/formatedpaper/1722580.pdf","source":{"id":"https://openalex.org/S5407000720","display_name":"Iconic Research and Engineering Journals","issn_l":"2456-8880","issn":["2456-8880"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Iconic Research and Engineering Journals","raw_type":"journal-article"},"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/9","score":0.4943999946117401,"display_name":"Industry, innovation and infrastructure"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":true,"pdf":true},"content_urls":{"pdf":"https://content.openalex.org/works/W7204934299.pdf","grobid_xml":"https://content.openalex.org/works/W7204934299.grobid-xml"},"referenced_works_count":47,"referenced_works":["https://openalex.org/W432071087","https://openalex.org/W575036385","https://openalex.org/W1972274821","https://openalex.org/W1973585648","https://openalex.org/W1987450917","https://openalex.org/W1999509994","https://openalex.org/W2140904188","https://openalex.org/W2484982554","https://openalex.org/W2575812970","https://openalex.org/W2755266123","https://openalex.org/W3035886909","https://openalex.org/W3088841665","https://openalex.org/W4231646313","https://openalex.org/W4239265769","https://openalex.org/W7019978257","https://openalex.org/W7042996423","https://openalex.org/W7053730696","https://openalex.org/W7066910597","https://openalex.org/W7117555108","https://openalex.org/W7117564193","https://openalex.org/W7117581712","https://openalex.org/W7117630293","https://openalex.org/W7121649650","https://openalex.org/W7125115539","https://openalex.org/W7125198459","https://openalex.org/W7125206930","https://openalex.org/W7128438084","https://openalex.org/W7128443851","https://openalex.org/W7132815807","https://openalex.org/W7132826070","https://openalex.org/W7132843054","https://openalex.org/W7132852011","https://openalex.org/W7137938881","https://openalex.org/W7137987652","https://openalex.org/W7138030623","https://openalex.org/W7143337988","https://openalex.org/W7143478157","https://openalex.org/W7143498545","https://openalex.org/W7154209738","https://openalex.org/W7154325203","https://openalex.org/W7160273224","https://openalex.org/W7160295005","https://openalex.org/W7162769521","https://openalex.org/W7162774288","https://openalex.org/W7163657584","https://openalex.org/W7163660466","https://openalex.org/W7171324815"],"related_works":["https://openalex.org/W4410208600","https://openalex.org/W2418596488","https://openalex.org/W4409486056","https://openalex.org/W4409532964","https://openalex.org/W3214531052","https://openalex.org/W1995761906","https://openalex.org/W2357629373","https://openalex.org/W33507185","https://openalex.org/W7214334802","https://openalex.org/W2389264911"],"abstract_inverted_index":{"Fired":[0],"heaters,":[1],"boilers":[2],"and":[3,10,19,33,42,46,89,100,110,132,140,150,165,167,171,175,178,194,207,218,227,247,250],"furnaces":[4],"are":[5,264],"among":[6],"the":[7,24,96,101,108,121,147,168,211,233,251],"most":[8],"safety-critical":[9],"failure-prone":[11],"classes":[12],"of":[13,52,69,76,78,98,113,214,235,241,253],"static":[14],"equipment":[15,71,115,244],"in":[16,61,116,245],"upstream":[17,63,117],"oil":[18,40,44],"gas":[20],"facilities.":[21],"They":[22],"supply":[23],"process":[25],"heat":[26],"required":[27],"for":[28,38,256,261],"crude":[29],"stabilization,":[30],"dehydration,":[31],"glycol":[32],"amine":[34],"regeneration,":[35],"steam":[36],"generation":[37],"enhanced":[39],"recovery,":[41],"heavy":[43],"processing,":[45],"they":[47],"do":[48],"so":[49],"under":[50],"conditions":[51],"high":[53,127],"temperature,":[54],"cyclic":[55],"loading,":[56],"aggressive":[57],"combustion":[58],"environments":[59],"and,":[60],"many":[62],"settings,":[64],"variable":[65],"fuel":[66],"quality.":[67],"Failures":[68],"fired":[70,114,243],"carry":[72],"disproportionate":[73],"consequences:":[74],"loss":[75],"containment":[77],"hydrocarbons":[79],"at":[80],"a":[81],"live":[82],"ignition":[83],"source,":[84],"tube":[85,191],"ruptures,":[86],"firebox":[87],"explosions":[88],"extended":[90],"production":[91],"deferment.":[92],"This":[93],"paper":[94],"reviews":[95,176],"state":[97],"practice":[99],"published":[102],"literature,":[103],"up":[104],"to":[105,187],"2019,":[106],"on":[107],"reliability":[109,237],"integrity":[111,216],"management":[112],"service.":[118],"It":[119,144],"surveys":[120],"dominant":[122],"damage":[123,258],"mechanisms,":[124],"including":[125],"creep,":[126],"temperature":[128,197],"hydrogen":[129],"attack,":[130],"external":[131],"internal":[133],"corrosion,":[134],"oxidation,":[135],"carburization,":[136],"thermal":[137],"fatigue,":[138],"fouling":[139],"flame":[141],"impingement":[142],"damage.":[143],"then":[145],"examines":[146],"governing":[148],"codes":[149],"recommended":[151],"practices,":[152],"principally":[153],"API":[154,156,158,160,163],"560,":[155],"530,":[157],"573,":[159],"579-1/ASME":[161],"FFS-1,":[162],"580":[164],"581,":[166],"ASME":[169],"Boiler":[170],"Pressure":[172],"Vessel":[173],"Code,":[174],"inspection":[177,192],"condition":[179],"monitoring":[180],"techniques":[181],"ranging":[182],"from":[183],"conventional":[184],"non-destructive":[185],"examination":[186],"infrared":[188],"thermography,":[189],"intelligent":[190],"tools":[193],"online":[195],"tube-skin":[196],"monitoring.":[198],"The":[199],"review":[200],"further":[201],"evaluates":[202],"risk-based":[203],"inspection,":[204],"fitness-for-service":[205],"assessment":[206],"reliability-centered":[208],"maintenance":[209],"as":[210,224],"organizing":[212],"frameworks":[213],"modern":[215],"management,":[217],"considers":[219],"emerging":[220],"digital":[221,228],"approaches":[222],"such":[223],"predictive":[225],"analytics":[226],"twins.":[229],"Gaps":[230],"identified":[231],"include":[232],"scarcity":[234],"upstream-specific":[236],"data,":[238],"limited":[239],"treatment":[240],"aging":[242],"remote":[246],"offshore":[248],"locations,":[249],"immaturity":[252],"prognostic":[254],"models":[255],"combined":[257],"mechanisms.":[259],"Directions":[260],"future":[262],"research":[263],"proposed.":[265]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W7204934299","counts_by_year":[{"year":2024,"cited_by_count":1},{"year":2023,"cited_by_count":1},{"year":2022,"cited_by_count":7},{"year":2021,"cited_by_count":5},{"year":2020,"cited_by_count":6},{"year":2019,"cited_by_count":8}],"updated_date":"2026-11-22T12:46:00.618207","created_date":"2026-09-02T00:00:00"}
