{"id":"https://openalex.org/W7204915639","doi":"https://doi.org/10.48550/arxiv.2608.30901","title":"Flexible Training Workloads in Large-Scale AI Data Centers for Transient-Stability Support in Transmission-Constrained Power Systems","display_name":"Flexible Training Workloads in Large-Scale AI Data Centers for Transient-Stability Support in Transmission-Constrained Power Systems","publication_year":2026,"publication_date":"2026-08-31","ids":{"openalex":"https://openalex.org/W7204915639","doi":"https://doi.org/10.48550/arxiv.2608.30901"},"language":"en","primary_location":{"id":"pmh:oai:arXiv.org:2608.30901","doi":null,"is_oa":true,"landing_page_url":"https://arxiv.org/abs/2608.30901","pdf_url":"https://arxiv.org/pdf/2608.30901","source":{"id":"https://openalex.org/S4306400194","display_name":"arXiv (Cornell University)","issn_l":"2331-8422","issn":["2331-8422"],"is_oa":true,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I205783295","host_organization_name":"Cornell University","host_organization_lineage":["https://openalex.org/I205783295"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"text"},"volume":null,"type":"preprint","is_traditional":true,"indexed_in":["arxiv","datacite"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"https://arxiv.org/pdf/2608.30901","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5036016494","display_name":"Jae-Kyeong Kim","orcid":"https://orcid.org/0000-0001-9486-2434","observed_orcids":["https://orcid.org/0000-0001-9486-2434"]},"institutions":[],"countries":[],"is_corresponding":true,"raw_author_name":"Kim, Jae-Kyeong","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":["https://openalex.org/A5036016494"],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":null,"has_fulltext":true,"cited_by_count":0,"citation_normalized_percentile":null,"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.9955999851226807,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.9955999851226807,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12277","display_name":"Frequency Control in Power Systems","score":0.002099999925121665,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.000699999975040555,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/ai-data-centers","display_name":"AI data centers","score":0.8920000195503235},{"id":"https://openalex.org/keywords/transient-stability","display_name":"transient stability","score":0.8240000009536743},{"id":"https://openalex.org/keywords/demand-side-flexibility","display_name":"demand-side flexibility","score":0.6389999985694885},{"id":"https://openalex.org/keywords/load-flexibility","display_name":"load flexibility","score":0.5410000085830688},{"id":"https://openalex.org/keywords/rotor-angle","display_name":"rotor angle","score":0.4050000011920929},{"id":"https://openalex.org/keywords/generation-limits","display_name":"generation limits","score":0.7570000290870667},{"id":"https://openalex.org/keywords/single-machine-infinite-bus-system","display_name":"single machine infinite bus","score":0.7630000114440918},{"id":"https://openalex.org/keywords/ieee-39-bus-system","display_name":"IEEE 39-bus system","score":0.8389999866485596}],"concepts":[{"id":"https://openalex.org/C2780598303","wikidata":"https://www.wikidata.org/wiki/Q65921492","display_name":"Flexibility (engineering)","level":2,"score":0.7452999949455261},{"id":"https://openalex.org/C188198153","wikidata":"https://www.wikidata.org/wiki/Q1613840","display_name":"Limiting","level":2,"score":0.612500011920929},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.6090999841690063},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5939000248908997},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.5051000118255615},{"id":"https://openalex.org/C2779370713","wikidata":"https://www.wikidata.org/wiki/Q357554","display_name":"Load management","level":2,"score":0.5016000270843506},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.47839999198913574},{"id":"https://openalex.org/C2777211547","wikidata":"https://www.wikidata.org/wiki/Q17141490","display_name":"Training (meteorology)","level":2,"score":0.4699999988079071},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.40939998626708984},{"id":"https://openalex.org/C40293303","wikidata":"https://www.wikidata.org/wiki/Q27137","display_name":"Electric power","level":3,"score":0.385699987411499},{"id":"https://openalex.org/C12713177","wikidata":"https://www.wikidata.org/wiki/Q1900281","display_name":"Perspective (graphical)","level":2,"score":0.382999986410141},{"id":"https://openalex.org/C138959212","wikidata":"https://www.wikidata.org/wiki/Q1806783","display_name":"Load balancing (electrical power)","level":3,"score":0.3725999891757965},{"id":"https://openalex.org/C2986689482","wikidata":"https://www.wikidata.org/wiki/Q1806775","display_name":"Peak load","level":2,"score":0.34549999237060547},{"id":"https://openalex.org/C89611455","wikidata":"https://www.wikidata.org/wiki/Q6804646","display_name":"Mechanism (biology)","level":2,"score":0.32249999046325684},{"id":"https://openalex.org/C77715397","wikidata":"https://www.wikidata.org/wiki/Q931447","display_name":"Electrical load","level":3,"score":0.3190000057220459},{"id":"https://openalex.org/C26517878","wikidata":"https://www.wikidata.org/wiki/Q228039","display_name":"Key (lock)","level":2,"score":0.31859999895095825},{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.3176000118255615},{"id":"https://openalex.org/C2777908891","wikidata":"https://www.wikidata.org/wiki/Q1806775","display_name":"Load profile","level":3,"score":0.31700000166893005},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3154999911785126},{"id":"https://openalex.org/C196796808","wikidata":"https://www.wikidata.org/wiki/Q132629","display_name":"Electrical network","level":2,"score":0.31060001254081726},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.3003999888896942},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.29159998893737793},{"id":"https://openalex.org/C423512","wikidata":"https://www.wikidata.org/wiki/Q383973","display_name":"Electricity generation","level":3,"score":0.2831999957561493},{"id":"https://openalex.org/C63540848","wikidata":"https://www.wikidata.org/wiki/Q3140932","display_name":"Fault tolerance","level":2,"score":0.28189998865127563},{"id":"https://openalex.org/C2778763806","wikidata":"https://www.wikidata.org/wiki/Q4826572","display_name":"Automatic Generation Control","level":4,"score":0.2728999853134155},{"id":"https://openalex.org/C177454536","wikidata":"https://www.wikidata.org/wiki/Q578290","display_name":"Emphasis (telecommunications)","level":2,"score":0.25949999690055847}],"mesh":[],"locations_count":2,"locations":[{"id":"pmh:oai:arXiv.org:2608.30901","doi":null,"is_oa":true,"landing_page_url":"https://arxiv.org/abs/2608.30901","pdf_url":"https://arxiv.org/pdf/2608.30901","source":{"id":"https://openalex.org/S4306400194","display_name":"arXiv (Cornell University)","issn_l":"2331-8422","issn":["2331-8422"],"is_oa":true,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I205783295","host_organization_name":"Cornell University","host_organization_lineage":["https://openalex.org/I205783295"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"text"},{"id":"doi:10.48550/arxiv.2608.30901","doi":"https://doi.org/10.48550/arxiv.2608.30901","is_oa":true,"landing_page_url":"https://doi.org/10.48550/arxiv.2608.30901","pdf_url":null,"source":{"id":"https://openalex.org/S4306400194","display_name":"arXiv (Cornell University)","issn_l":"2331-8422","issn":["2331-8422"],"is_oa":true,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I205783295","host_organization_name":"Cornell University","host_organization_lineage":["https://openalex.org/I205783295"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"Preprint"}],"best_oa_location":{"id":"pmh:oai:arXiv.org:2608.30901","doi":null,"is_oa":true,"landing_page_url":"https://arxiv.org/abs/2608.30901","pdf_url":"https://arxiv.org/pdf/2608.30901","source":{"id":"https://openalex.org/S4306400194","display_name":"arXiv (Cornell University)","issn_l":"2331-8422","issn":["2331-8422"],"is_oa":true,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I205783295","host_organization_name":"Cornell University","host_organization_lineage":["https://openalex.org/I205783295"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"text"},"sustainable_development_goals":[{"score":0.8970999717712402,"display_name":"Industry, innovation and infrastructure","id":"https://metadata.un.org/sdg/9"},{"score":0.878000020980835,"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":true,"pdf":true},"content_urls":{"pdf":"https://content.openalex.org/works/W7204915639.pdf","grobid_xml":"https://content.openalex.org/works/W7204915639.grobid-xml"},"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W7165631266","https://openalex.org/W7131102988","https://openalex.org/W7222947187","https://openalex.org/W4416452640","https://openalex.org/W7221049021","https://openalex.org/W7170167621","https://openalex.org/W7161166334","https://openalex.org/W4412739845","https://openalex.org/W4416050543","https://openalex.org/W7221759630"],"abstract_inverted_index":{"The":[0,87,110],"rapid":[1],"expansion":[2],"of":[3,44,179],"large-scale":[4,132],"artificial":[5],"intelligence":[6],"(AI)":[7],"data":[8,46,181],"centers":[9,47,182],"is":[10,113],"adding":[11],"substantial,":[12],"concentrated,":[13],"and":[14,104,122,130,154,194],"rapidly":[15],"varying":[16],"loads":[17],"to":[18,79,94],"transmission-constrained":[19],"power":[20,134],"systems.":[21],"Although":[22],"such":[23],"load":[24,42,61,89],"variations":[25],"are":[26,198],"generally":[27],"regarded":[28],"as":[29],"operational":[30],"challenges,":[31],"this":[32,55,57],"paper":[33,58],"presents":[34],"an":[35],"alternative":[36],"perspective":[37],"in":[38,116,125],"which":[39],"the":[40,101,106,126,146,164,175],"upward":[41,176],"flexibility":[43],"AI":[45,73,180],"could":[48],"be":[49],"coordinated":[50],"for":[51],"transient-stability":[52,186],"support.":[53],"To":[54],"end,":[56],"proposes":[59],"training-induced":[60],"surge":[62],"(TILS),":[63],"a":[64,117,131,159],"fast":[65],"demand-side":[66],"strategy":[67],"that":[68,142,174],"initiates":[69],"or":[70],"resumes":[71],"flexible":[72,192],"training":[74],"workloads":[75],"after":[76],"fault":[77],"clearing":[78],"increase":[80,90,145],"active-power":[81],"demand":[82],"at":[83,156],"electrically":[84],"effective":[85],"locations.":[86],"resulting":[88],"allows":[91],"accelerating":[92],"generators":[93,166],"supply":[95],"additional":[96],"electrical":[97,161,190],"power,":[98],"thereby":[99],"reducing":[100],"accelerating-power":[102],"imbalance":[103],"limiting":[105],"first-swing":[107],"rotor-angle":[108],"excursion.":[109],"underlying":[111],"mechanism":[112],"first":[114],"clarified":[115],"single-machine":[118],"infinite-bus":[119],"(SMIB)":[120],"system":[121,129],"then":[123],"evaluated":[124],"IEEE":[127],"39-bus":[128],"Korean":[133],"system.":[135],"Results":[136],"across":[137],"all":[138],"three":[139],"systems":[140],"demonstrate":[141],"TILS":[143],"can":[144,183],"transient-stability-constrained":[147],"generation":[148],"limit.":[149],"Larger":[150],"responses,":[151],"earlier":[152],"activation,":[153],"siting":[155],"buses":[157],"with":[158],"stronger":[160],"influence":[162],"on":[163],"critical":[165],"provide":[167,184],"greater":[168],"generation-limit":[169],"increases.":[170],"These":[171],"results":[172],"suggest":[173],"load-response":[177],"capability":[178],"complementary":[185],"support":[187],"when":[188],"sufficient":[189],"headroom,":[191],"workloads,":[193],"reliable":[195],"grid-triggered":[196],"activation":[197],"available.":[199]},"counts_by_year":[],"updated_date":"2026-11-06T12:05:46.655746","created_date":"2026-09-02T00:00:00"}
