{"id":"https://openalex.org/W7204652621","doi":"https://doi.org/10.1016/j.enbuild.2026.118164","title":"HeatShift-HP: A Techno-Economic framework for assessing heat pump load shifting under dynamic tariffs and grid fees","display_name":"HeatShift-HP: A Techno-Economic framework for assessing heat pump load shifting under dynamic tariffs and grid fees","publication_year":2026,"publication_date":"2026-08-29","ids":{"openalex":"https://openalex.org/W7204652621","doi":"https://doi.org/10.1016/j.enbuild.2026.118164"},"language":"en","primary_location":{"id":"doi:10.1016/j.enbuild.2026.118164","doi":"https://doi.org/10.1016/j.enbuild.2026.118164","is_oa":true,"landing_page_url":"https://doi.org/10.1016/j.enbuild.2026.118164","pdf_url":"https://www.sciencedirect.com/science/article/pii/S0378778826012247/pdf","source":{"id":"https://openalex.org/S6846437","display_name":"Energy and Buildings","issn_l":"0378-7788","issn":["0378-7788","1872-6178"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["anvur-class-a","anvur-scientific","cwts-core","dongbi-b","jufo-3","norway-2","poland-140","russia-white-list-1","vabb-shw"],"host_organization":"https://openalex.org/P4310320990","host_organization_name":"Elsevier BV","host_organization_lineage":["https://openalex.org/P4310320990"],"host_organization_lineage_names":["Elsevier BV"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Energy and Buildings","raw_type":"journal-article"},"volume":null,"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"hybrid","oa_url":"https://www.sciencedirect.com/science/article/pii/S0378778826012247/pdf","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5070493740","display_name":"Alexander Neubauer","orcid":"https://orcid.org/0000-0002-2476-3681","observed_orcids":["https://orcid.org/0000-0002-2476-3681"]},"institutions":[{"id":"https://openalex.org/I148283060","display_name":"Lawrence Berkeley National Laboratory","ror":"https://ror.org/02jbv0t02","country_code":"US","type":"facility","lineage":["https://openalex.org/I1330989302","https://openalex.org/I148283060","https://openalex.org/I39565521"]},{"id":"https://openalex.org/I4577782","display_name":"Technische Universit\u00e4t Berlin","ror":"https://ror.org/03v4gjf40","country_code":"DE","type":"education","lineage":["https://openalex.org/I4577782"]}],"countries":["DE","US"],"is_corresponding":true,"raw_author_name":"Alexander Neubauer","raw_affiliation_strings":["Hermann-Rietschel-Institut, Technische Universit\u00e4t Berlin, 10587, Berlin, Germany","Lawrence Berkeley National Laboratory, Berkeley, CA, 94720, USA"],"raw_orcid":"https://orcid.org/0000-0002-2476-3681","affiliations":[{"raw_affiliation_string":"Hermann-Rietschel-Institut, Technische Universit\u00e4t Berlin, 10587, Berlin, Germany","institution_ids":["https://openalex.org/I4577782"]},{"raw_affiliation_string":"Lawrence Berkeley National Laboratory, Berkeley, CA, 94720, USA","institution_ids":["https://openalex.org/I148283060"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5148605945","display_name":"Oliver Awasthi-Hilgendorf","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4577782","display_name":"Technische Universit\u00e4t Berlin","ror":"https://ror.org/03v4gjf40","country_code":"DE","type":"education","lineage":["https://openalex.org/I4577782"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Oliver Awasthi-Hilgendorf","raw_affiliation_strings":["Hermann-Rietschel-Institut, Technische Universit\u00e4t Berlin, 10587, Berlin, Germany"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Hermann-Rietschel-Institut, Technische Universit\u00e4t Berlin, 10587, Berlin, Germany","institution_ids":["https://openalex.org/I4577782"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5102934002","display_name":"Peter Grant","orcid":"https://orcid.org/0000-0003-1240-2018","observed_orcids":["https://orcid.org/0000-0003-1240-2018"]},"institutions":[{"id":"https://openalex.org/I148283060","display_name":"Lawrence Berkeley National Laboratory","ror":"https://ror.org/02jbv0t02","country_code":"US","type":"facility","lineage":["https://openalex.org/I1330989302","https://openalex.org/I148283060","https://openalex.org/I39565521"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Peter Grant","raw_affiliation_strings":["Lawrence Berkeley National Laboratory, Berkeley, CA, 94720, USA"],"raw_orcid":"https://orcid.org/0000-0003-1240-2018","affiliations":[{"raw_affiliation_string":"Lawrence Berkeley National Laboratory, Berkeley, CA, 94720, USA","institution_ids":["https://openalex.org/I148283060"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5088990923","display_name":"Tianzhen Hong","orcid":"https://orcid.org/0000-0003-1886-9137","observed_orcids":["https://orcid.org/0000-0003-1886-9137"]},"institutions":[{"id":"https://openalex.org/I148283060","display_name":"Lawrence Berkeley National Laboratory","ror":"https://ror.org/02jbv0t02","country_code":"US","type":"facility","lineage":["https://openalex.org/I1330989302","https://openalex.org/I148283060","https://openalex.org/I39565521"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Tianzhen Hong","raw_affiliation_strings":["Lawrence Berkeley National Laboratory, Berkeley, CA, 94720, USA"],"raw_orcid":"https://orcid.org/0000-0003-1886-9137","affiliations":[{"raw_affiliation_string":"Lawrence Berkeley National Laboratory, Berkeley, CA, 94720, USA","institution_ids":["https://openalex.org/I148283060"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5043326131","display_name":"Yannick F\u00fcrst","orcid":"https://orcid.org/0009-0000-5138-3310","observed_orcids":["https://orcid.org/0009-0000-5138-3310"]},"institutions":[{"id":"https://openalex.org/I4577782","display_name":"Technische Universit\u00e4t Berlin","ror":"https://ror.org/03v4gjf40","country_code":"DE","type":"education","lineage":["https://openalex.org/I4577782"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Yannick F\u00fcrst","raw_affiliation_strings":["Hermann-Rietschel-Institut, Technische Universit\u00e4t Berlin, 10587, Berlin, Germany"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Hermann-Rietschel-Institut, Technische Universit\u00e4t Berlin, 10587, Berlin, Germany","institution_ids":["https://openalex.org/I4577782"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5079777919","display_name":"Stefan Brandt","orcid":"https://orcid.org/0000-0003-0419-0764","observed_orcids":["https://orcid.org/0000-0003-0419-0764"]},"institutions":[{"id":"https://openalex.org/I4577782","display_name":"Technische Universit\u00e4t Berlin","ror":"https://ror.org/03v4gjf40","country_code":"DE","type":"education","lineage":["https://openalex.org/I4577782"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Stefan Brandt","raw_affiliation_strings":["Hermann-Rietschel-Institut, Technische Universit\u00e4t Berlin, 10587, Berlin, Germany"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Hermann-Rietschel-Institut, Technische Universit\u00e4t Berlin, 10587, Berlin, Germany","institution_ids":["https://openalex.org/I4577782"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5073655858","display_name":"Martin Kriegel","orcid":"https://orcid.org/0000-0003-0107-6333","observed_orcids":["https://orcid.org/0000-0003-0107-6333"]},"institutions":[{"id":"https://openalex.org/I4577782","display_name":"Technische Universit\u00e4t Berlin","ror":"https://ror.org/03v4gjf40","country_code":"DE","type":"education","lineage":["https://openalex.org/I4577782"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Martin Kriegel","raw_affiliation_strings":["Hermann-Rietschel-Institut, Technische Universit\u00e4t Berlin, 10587, Berlin, Germany"],"raw_orcid":"https://orcid.org/0000-0003-0107-6333","affiliations":[{"raw_affiliation_string":"Hermann-Rietschel-Institut, Technische Universit\u00e4t Berlin, 10587, Berlin, Germany","institution_ids":["https://openalex.org/I4577782"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":2,"corresponding_author_ids":["https://openalex.org/A5070493740"],"corresponding_institution_ids":["https://openalex.org/I148283060","https://openalex.org/I4577782"],"apc_list":{"value":4260,"currency":"USD","value_usd":4260},"apc_paid":{"value":4260,"currency":"USD","value_usd":4260},"fwci":1.4672,"has_fulltext":true,"cited_by_count":1,"citation_normalized_percentile":{"value":0.87022446,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":92,"max":95},"biblio":{"volume":"371","issue":null,"first_page":"118164","last_page":"118164"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.8633000254631042,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.8633000254631042,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11185","display_name":"Integrated Energy Systems Optimization","score":0.07240000367164612,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.029899999499320984,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/heat-pumps","display_name":"heat pumps","score":0.8629999756813049},{"id":"https://openalex.org/keywords/load-shifting","display_name":"load shifting","score":0.9309999942779541},{"id":"https://openalex.org/keywords/dynamic-tariffs","display_name":"dynamic tariffs","score":0.7310000061988831},{"id":"https://openalex.org/keywords/techno-economic-analysis","display_name":"techno-economic analysis","score":0.9570000171661377},{"id":"https://openalex.org/keywords/electricity-pricing","display_name":"electricity pricing","score":0.4390000104904175}],"concepts":[{"id":"https://openalex.org/C2776461528","wikidata":"https://www.wikidata.org/wiki/Q131313","display_name":"Heat pump","level":3,"score":0.6531999707221985},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.59170001745224},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.43130001425743103},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.384799987077713},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.3797000050544739},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.3659999966621399},{"id":"https://openalex.org/C2986689482","wikidata":"https://www.wikidata.org/wiki/Q1806775","display_name":"Peak load","level":2,"score":0.35499998927116394},{"id":"https://openalex.org/C2989099649","wikidata":"https://www.wikidata.org/wiki/Q233558","display_name":"Grid system","level":3,"score":0.3422999978065491},{"id":"https://openalex.org/C2989353520","wikidata":"https://www.wikidata.org/wiki/Q2419918","display_name":"Heat load","level":2,"score":0.30809998512268066},{"id":"https://openalex.org/C2777030403","wikidata":"https://www.wikidata.org/wiki/Q17099419","display_name":"Load shifting","level":3,"score":0.30790001153945923},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.30379998683929443},{"id":"https://openalex.org/C186370098","wikidata":"https://www.wikidata.org/wiki/Q442787","display_name":"Energy (signal processing)","level":2,"score":0.3018999993801117},{"id":"https://openalex.org/C134560507","wikidata":"https://www.wikidata.org/wiki/Q753291","display_name":"Environmental economics","level":1,"score":0.30140000581741333},{"id":"https://openalex.org/C2779370713","wikidata":"https://www.wikidata.org/wiki/Q357554","display_name":"Load management","level":2,"score":0.2667999863624573},{"id":"https://openalex.org/C13119800","wikidata":"https://www.wikidata.org/wiki/Q902090","display_name":"Coefficient of performance","level":4,"score":0.2572999894618988},{"id":"https://openalex.org/C2781099182","wikidata":"https://www.wikidata.org/wiki/Q24963825","display_name":"Cooling load","level":3,"score":0.25440001487731934}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1016/j.enbuild.2026.118164","doi":"https://doi.org/10.1016/j.enbuild.2026.118164","is_oa":true,"landing_page_url":"https://doi.org/10.1016/j.enbuild.2026.118164","pdf_url":"https://www.sciencedirect.com/science/article/pii/S0378778826012247/pdf","source":{"id":"https://openalex.org/S6846437","display_name":"Energy and Buildings","issn_l":"0378-7788","issn":["0378-7788","1872-6178"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["anvur-class-a","anvur-scientific","cwts-core","dongbi-b","jufo-3","norway-2","poland-140","russia-white-list-1","vabb-shw"],"host_organization":"https://openalex.org/P4310320990","host_organization_name":"Elsevier BV","host_organization_lineage":["https://openalex.org/P4310320990"],"host_organization_lineage_names":["Elsevier BV"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Energy and Buildings","raw_type":"journal-article"},{"id":"pmh:oai:escholarship.org:ark:/13030/qt803399rv","doi":null,"is_oa":true,"landing_page_url":"https://escholarship.org/uc/item/803399rv","pdf_url":null,"source":{"id":"https://openalex.org/S4306400115","display_name":"eScholarship (California Digital Library)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I2801248553","host_organization_name":"California Digital Library","host_organization_lineage":["https://openalex.org/I2801248553"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by-nd","license_id":"https://openalex.org/licenses/cc-by-nd","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Energy and Buildings, vol 371","raw_type":"article"}],"best_oa_location":{"id":"doi:10.1016/j.enbuild.2026.118164","doi":"https://doi.org/10.1016/j.enbuild.2026.118164","is_oa":true,"landing_page_url":"https://doi.org/10.1016/j.enbuild.2026.118164","pdf_url":"https://www.sciencedirect.com/science/article/pii/S0378778826012247/pdf","source":{"id":"https://openalex.org/S6846437","display_name":"Energy and Buildings","issn_l":"0378-7788","issn":["0378-7788","1872-6178"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["anvur-class-a","anvur-scientific","cwts-core","dongbi-b","jufo-3","norway-2","poland-140","russia-white-list-1","vabb-shw"],"host_organization":"https://openalex.org/P4310320990","host_organization_name":"Elsevier BV","host_organization_lineage":["https://openalex.org/P4310320990"],"host_organization_lineage_names":["Elsevier BV"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Energy and Buildings","raw_type":"journal-article"},"sustainable_development_goals":[{"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7","score":0.9853000044822693},{"display_name":"Climate action","id":"https://metadata.un.org/sdg/13","score":0.9786999821662903},{"display_name":"Sustainable cities and communities","id":"https://metadata.un.org/sdg/11","score":0.47999998927116394}],"study_designs":[],"awards":[{"id":"https://openalex.org/G2510324025","display_name":null,"funder_award_id":"ML-EBESR 03EN1076B","funder_id":"https://openalex.org/F4320323803","funder_display_name":"Bundesministerium f\u00fcr Wirtschaft und Energie"},{"id":"https://openalex.org/G9000635399","display_name":"Verbundvorhaben: EnOB: ML-EBESR - Entwicklung einer selbstoptimier ten Regelung zum effizienten und netzdienlichen Betrieb von (regenerativen) Energiesystemen unter Verwendung von maschinellem Lernen, Teilvorhaben: Entwicklung der Prognose- und Regelungsalgorithmen","funder_award_id":"03EN1076B","funder_id":"https://openalex.org/F4320323803","funder_display_name":"Bundesministerium f\u00fcr Wirtschaft und Energie"}],"funders":[{"id":"https://openalex.org/F4320323803","display_name":"Bundesministerium f\u00fcr Wirtschaft und Energie","ror":"https://ror.org/02vgg2808"},{"id":"https://openalex.org/F4320338292","display_name":"Lawrence Berkeley National Laboratory","ror":"https://ror.org/02jbv0t02"}],"has_content":{"pdf":true,"grobid_xml":true},"content_urls":{"pdf":"https://content.openalex.org/works/W7204652621.pdf","grobid_xml":"https://content.openalex.org/works/W7204652621.grobid-xml"},"referenced_works_count":35,"referenced_works":["https://openalex.org/W2011938518","https://openalex.org/W2073505656","https://openalex.org/W2166751342","https://openalex.org/W2464717066","https://openalex.org/W2786385826","https://openalex.org/W2794034951","https://openalex.org/W2801306872","https://openalex.org/W2929874559","https://openalex.org/W2973783235","https://openalex.org/W3007815452","https://openalex.org/W3027785214","https://openalex.org/W3140310299","https://openalex.org/W3209188603","https://openalex.org/W3211129524","https://openalex.org/W4311147038","https://openalex.org/W4311816907","https://openalex.org/W4313436711","https://openalex.org/W4362734279","https://openalex.org/W4380201551","https://openalex.org/W4382020633","https://openalex.org/W4387539797","https://openalex.org/W4396813774","https://openalex.org/W4401503269","https://openalex.org/W4402905438","https://openalex.org/W4406080305","https://openalex.org/W4408689981","https://openalex.org/W4414396980","https://openalex.org/W4416792296","https://openalex.org/W6926521327","https://openalex.org/W6959624797","https://openalex.org/W7082439177","https://openalex.org/W7116629766","https://openalex.org/W7117484319","https://openalex.org/W7125025305","https://openalex.org/W7128435224"],"related_works":["https://openalex.org/W4398230038","https://openalex.org/W4398230031","https://openalex.org/W4413977568","https://openalex.org/W6965566457","https://openalex.org/W4403058679","https://openalex.org/W1553353840","https://openalex.org/W7123352987","https://openalex.org/W6908676132","https://openalex.org/W2591749558","https://openalex.org/W7163034701"],"abstract_inverted_index":{"Rapid":[0],"growth":[1],"of":[2,9,16,24,67,107,165,234,251,293],"electric":[3,18],"demand":[4],"combined":[5],"with":[6,59,130,150,208,307],"increased":[7],"penetration":[8],"intermittent":[10],"power":[11],"sources":[12],"increases":[13],"the":[14,21,162,174,187,205,275,290],"value":[15,292],"flexible":[17],"heating,":[19],"but":[20,244],"techno-economic":[22],"role":[23],"central":[25],"hot-water":[26,142],"storage":[27,54,218],"under":[28,212],"realistic":[29],"tariffs":[30,306],"remains":[31,237],"unclear.":[32],"This":[33],"paper":[34],"introduces":[35],"HeatShift-HP":[36],",":[37],"an":[38],"open-source":[39],"Python/Modelica":[40],"co-simulation":[41],"workflow.":[42],"The":[43,75,110,231,278],"framework":[44,76],"couples":[45],"a":[46,52,60,98,104,115],"generic":[47],"air-to-water":[48],"heat":[49,171,191,229,264,287],"pump":[50],"and":[51,64,71,80,87,94,121,126,131,169,199,226,304],"stratified":[53],"tank":[55,83],"Functional":[56],"Mock-up":[57],"Unit":[58],"supervisory":[61],"rule-based":[62],"controller":[63,92],"time":[65],"series":[66],"weather,":[68],"heating":[69],"load,":[70],"end-user":[72],"electricity":[73],"prices.":[74],"targets":[77],"plant-side":[78],"flexibility":[79,222],"varies":[81],"specific":[82,190],"volume,":[84],"nominal":[85,158,175],"supply":[86,176],"return":[88],"temperatures,":[89],"heat-pump":[90],"sizing,":[91],"settings,":[93],"tariff":[95],"variants,":[96],"including":[97],"price-responsive":[99],"boosting":[100],"strategy":[101],"constrained":[102],"by":[103,193,223,266],"cost-neutral":[105],"coefficient":[106],"performance":[108,168],"approximation.":[109],"workflow":[111],"is":[112,161],"applied":[113],"to":[114,182,253,270,274],"single-family":[116],"reference":[117],"building":[118,151],"in":[119,197,202,241,259],"Berlin":[120,198,246,260],"Chicago":[122,203],"using":[123],"2025":[124],"weather":[125],"hourly":[127],"retail":[128,305],"prices":[129],"without":[132],"dynamic":[133],"grid-fee":[134],"components.":[135],"A":[136],"theoretical":[137],"pre-analysis":[138],"shows":[139],"that":[140,157,281],"typical":[141],"buffers":[143],"provide":[144],"only":[145],"limited":[146],"stand-alone":[147],"autonomy":[148],"compared":[149],"thermal":[152],"mass.":[153],"Annual":[154],"simulations":[155],"show":[156,249,280],"system":[159,283],"temperature":[160,177],"dominant":[163],"driver":[164],"both":[166,242],"seasonal":[167],"paid":[170,189,263],"costs.":[172],"Lowering":[173],"from":[178],"40":[179],"\u2218":[180,184],"C":[181,185],"35":[183],"reduces":[186],"median":[188,262],"cost":[192],"about":[194,267],"3.7":[195],"%":[196,201,240,269,272],"4.4":[200],"for":[204],"standard":[206],"controller,":[207],"similarly":[209],"strong":[210,309],"reductions":[211],"price-based":[213,235,294],"control.":[214],"By":[215],"contrast,":[216],"additional":[217],"mainly":[219],"improves":[220],"operational":[221],"reducing":[224],"cycling":[225],"increasing":[227],"low-price":[228],"generation.":[230],"pooled":[232],"effect":[233],"control":[236,295,302],"below":[238],"1":[239],"cities,":[243],"matched":[245],"dynamic-grid":[247],"cases":[248],"savings":[250],"up":[252],"4.0":[254],"%.":[255],"Dynamic":[256],"grid":[257],"fees":[258],"reduce":[261],"costs":[265],"7.0":[268],"7.6":[271],"relative":[273],"fixed-grid":[276],"tariff.":[277],"results":[279],"low-temperature":[282],"design":[284],"minimises":[285],"absolute":[286],"costs,":[288],"whereas":[289],"incremental":[291],"depends":[296],"primarily":[297],"on":[298],"sufficient":[299],"storage,":[300],"moderate":[301],"actions,":[303],"sufficiently":[308],"temporal":[310],"price":[311],"variation.":[312]},"counts_by_year":[{"year":2026,"cited_by_count":1}],"updated_date":"2026-11-04T10:54:05.112534","created_date":"2026-08-30T00:00:00"}
