{"id":"https://openalex.org/W7204487355","doi":"https://doi.org/10.5935/jetia.v12i60.4036","title":"Impact of Inter-Winding Magnetic and Capacitive Coupling on SFRA Signature","display_name":"Impact of Inter-Winding Magnetic and Capacitive Coupling on SFRA Signature","publication_year":2026,"publication_date":"2026-01-01","ids":{"openalex":"https://openalex.org/W7204487355","doi":"https://doi.org/10.5935/jetia.v12i60.4036"},"language":"en","primary_location":{"id":"doi:10.5935/jetia.v12i60.4036","doi":"https://doi.org/10.5935/jetia.v12i60.4036","is_oa":true,"landing_page_url":"https://doi.org/10.5935/jetia.v12i60.4036","pdf_url":null,"source":{"id":"https://openalex.org/S2764766405","display_name":"ITEGAM- Journal of Engineering and Technology for Industrial Applications (ITEGAM-JETIA)","issn_l":"2447-0228","issn":["2447-0228"],"is_oa":true,"is_in_doaj":true,"is_core":false,"listed_in":["doaj"],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"ITEGAM- Journal of Engineering and Technology for Industrial Applications (ITEGAM-JETIA","raw_type":"journal-article"},"volume":null,"type":"article","is_traditional":true,"indexed_in":["crossref","doaj"],"open_access":{"is_oa":true,"oa_status":"diamond","oa_url":"https://doi.org/10.5935/jetia.v12i60.4036","any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5054797694","display_name":"Mayur V. Gojiya","orcid":"https://orcid.org/0000-0002-4000-0078","observed_orcids":["https://orcid.org/0000-0002-4000-0078"]},"institutions":[{"id":"https://openalex.org/I29563240","display_name":"Gujarat Technological University","ror":"https://ror.org/059x8vm09","country_code":"IN","type":"education","lineage":["https://openalex.org/I29563240"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Mayur V gojiya","raw_affiliation_strings":["Gujarat Technological University"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Gujarat Technological University","institution_ids":["https://openalex.org/I29563240"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5027343780","display_name":"Mehul Dansinh Solanki","orcid":"https://orcid.org/0000-0001-8852-3145","observed_orcids":["https://orcid.org/0000-0001-8852-3145"]},"institutions":[{"id":"https://openalex.org/I29563240","display_name":"Gujarat Technological University","ror":"https://ror.org/059x8vm09","country_code":"IN","type":"education","lineage":["https://openalex.org/I29563240"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Mehul Dansinh Solanki","raw_affiliation_strings":["Gujarat Technological University"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Gujarat Technological University","institution_ids":["https://openalex.org/I29563240"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5023464131","display_name":"Ashokkumar Parmar","orcid":"https://orcid.org/0000-0001-7529-3774","observed_orcids":["https://orcid.org/0000-0001-7529-3774"]},"institutions":[{"id":"https://openalex.org/I29563240","display_name":"Gujarat Technological University","ror":"https://ror.org/059x8vm09","country_code":"IN","type":"education","lineage":["https://openalex.org/I29563240"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Ashokkumar Parmar","raw_affiliation_strings":["Gujarat Technological University"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Gujarat Technological University","institution_ids":["https://openalex.org/I29563240"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5132771690","display_name":"Maqbul Ghanchi","orcid":"https://orcid.org/0009-0009-5399-8728","observed_orcids":["https://orcid.org/0009-0009-5399-8728"]},"institutions":[{"id":"https://openalex.org/I29563240","display_name":"Gujarat Technological University","ror":"https://ror.org/059x8vm09","country_code":"IN","type":"education","lineage":["https://openalex.org/I29563240"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Maqbul U. Ghanchi","raw_affiliation_strings":["Gujarat Technological University"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Gujarat Technological University","institution_ids":["https://openalex.org/I29563240"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I29563240"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.0,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"12","issue":"60","first_page":"1180","last_page":"1187"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11343","display_name":"Power Transformer Diagnostics and Insulation","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11343","display_name":"Power Transformer Diagnostics and Insulation","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11222","display_name":"Magnetic Properties and Applications","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2504","display_name":"Electronic, Optical and Magnetic Materials"},"field":{"id":"https://openalex.org/fields/25","display_name":"Materials Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10511","display_name":"High voltage insulation and dielectric phenomena","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/sweep-frequency-response-analysis","display_name":"sweep frequency response analysis","score":0.9909999966621399},{"id":"https://openalex.org/keywords/power-transformer-windings","display_name":"power transformer windings","score":0.753000020980835},{"id":"https://openalex.org/keywords/magnetic-coupling","display_name":"magnetic coupling","score":0.8820000290870667},{"id":"https://openalex.org/keywords/capacitive-coupling","display_name":"capacitive coupling","score":0.9959999918937683},{"id":"https://openalex.org/keywords/mechanical-deformation","display_name":"mechanical deformation","score":0.6629999876022339},{"id":"https://openalex.org/keywords/fault-localization","display_name":"fault location","score":0.8199999928474426},{"id":"https://openalex.org/keywords/radial-buckling","display_name":"radial buckling","score":0.7409999966621399},{"id":"https://openalex.org/keywords/open-circuit-fault","display_name":"open-circuit fault","score":0.8700000047683716},{"id":"https://openalex.org/keywords/oil-immersed-transformers","display_name":"oil-immersed transformers","score":0.8429999947547913},{"id":"https://openalex.org/keywords/transformer-diagnostics","display_name":"transformer diagnostics","score":0.3930000066757202}],"concepts":[{"id":"https://openalex.org/C66322947","wikidata":"https://www.wikidata.org/wiki/Q11658","display_name":"Transformer","level":3,"score":0.7098000049591064},{"id":"https://openalex.org/C206755178","wikidata":"https://www.wikidata.org/wiki/Q1131271","display_name":"Capacitive sensing","level":2,"score":0.6176000237464905},{"id":"https://openalex.org/C68278764","wikidata":"https://www.wikidata.org/wiki/Q444167","display_name":"Capacitive coupling","level":3,"score":0.5961999893188477},{"id":"https://openalex.org/C176605952","wikidata":"https://www.wikidata.org/wiki/Q827674","display_name":"Phasor","level":4,"score":0.5702999830245972},{"id":"https://openalex.org/C131584629","wikidata":"https://www.wikidata.org/wiki/Q4308705","display_name":"Coupling (piping)","level":2,"score":0.453900009393692},{"id":"https://openalex.org/C30403606","wikidata":"https://www.wikidata.org/wiki/Q2981904","display_name":"Electromagnetic coil","level":2,"score":0.42739999294281006},{"id":"https://openalex.org/C2779696439","wikidata":"https://www.wikidata.org/wiki/Q7512811","display_name":"Signature (topology)","level":2,"score":0.41019999980926514},{"id":"https://openalex.org/C177872590","wikidata":"https://www.wikidata.org/wiki/Q1498289","display_name":"Inductive coupling","level":2,"score":0.3978999853134155},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.397599995136261},{"id":"https://openalex.org/C37580369","wikidata":"https://www.wikidata.org/wiki/Q7655123","display_name":"Sweep frequency response analysis","level":2,"score":0.3952000141143799},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.39160001277923584},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3889999985694885},{"id":"https://openalex.org/C196489102","wikidata":"https://www.wikidata.org/wiki/Q3442941","display_name":"Rotary variable differential transformer","level":5,"score":0.3691999912261963},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.3677999973297119},{"id":"https://openalex.org/C17829176","wikidata":"https://www.wikidata.org/wiki/Q179043","display_name":"Electrical impedance","level":2,"score":0.36719998717308044},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.3555999994277954},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.3472000062465668},{"id":"https://openalex.org/C24890656","wikidata":"https://www.wikidata.org/wiki/Q82811","display_name":"Acoustics","level":1,"score":0.34279999136924744},{"id":"https://openalex.org/C135628077","wikidata":"https://www.wikidata.org/wiki/Q220184","display_name":"Finite element method","level":2,"score":0.32339999079704285},{"id":"https://openalex.org/C30066665","wikidata":"https://www.wikidata.org/wiki/Q164399","display_name":"Capacitance","level":3,"score":0.3199000060558319},{"id":"https://openalex.org/C133770746","wikidata":"https://www.wikidata.org/wiki/Q856535","display_name":"Current transformer","level":4,"score":0.30630001425743103},{"id":"https://openalex.org/C104892082","wikidata":"https://www.wikidata.org/wiki/Q17156810","display_name":"Low frequency","level":2,"score":0.3061999976634979},{"id":"https://openalex.org/C2989427145","wikidata":"https://www.wikidata.org/wiki/Q260295","display_name":"Single phase","level":2,"score":0.3012999892234802},{"id":"https://openalex.org/C117323899","wikidata":"https://www.wikidata.org/wiki/Q1907989","display_name":"Distribution transformer","level":4,"score":0.30000001192092896},{"id":"https://openalex.org/C23572009","wikidata":"https://www.wikidata.org/wiki/Q964981","display_name":"Equivalent circuit","level":3,"score":0.28519999980926514},{"id":"https://openalex.org/C29210110","wikidata":"https://www.wikidata.org/wiki/Q177897","display_name":"Inductance","level":3,"score":0.2849999964237213},{"id":"https://openalex.org/C8590192","wikidata":"https://www.wikidata.org/wiki/Q1054694","display_name":"Frequency response","level":2,"score":0.2759000062942505},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.27410000562667847},{"id":"https://openalex.org/C2775846686","wikidata":"https://www.wikidata.org/wiki/Q643012","display_name":"Condition monitoring","level":2,"score":0.2685000002384186},{"id":"https://openalex.org/C129187525","wikidata":"https://www.wikidata.org/wiki/Q10858078","display_name":"Fault current limiter","level":4,"score":0.26179999113082886},{"id":"https://openalex.org/C73000952","wikidata":"https://www.wikidata.org/wiki/Q17007827","display_name":"Discretization","level":2,"score":0.2563999891281128},{"id":"https://openalex.org/C44280652","wikidata":"https://www.wikidata.org/wiki/Q104837","display_name":"Phase (matter)","level":2,"score":0.2556000053882599},{"id":"https://openalex.org/C52192207","wikidata":"https://www.wikidata.org/wiki/Q5322","display_name":"Capacitor","level":3,"score":0.25429999828338623}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.5935/jetia.v12i60.4036","doi":"https://doi.org/10.5935/jetia.v12i60.4036","is_oa":true,"landing_page_url":"https://doi.org/10.5935/jetia.v12i60.4036","pdf_url":null,"source":{"id":"https://openalex.org/S2764766405","display_name":"ITEGAM- Journal of Engineering and Technology for Industrial Applications (ITEGAM-JETIA)","issn_l":"2447-0228","issn":["2447-0228"],"is_oa":true,"is_in_doaj":true,"is_core":false,"listed_in":["doaj"],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"ITEGAM- Journal of Engineering and Technology for Industrial Applications (ITEGAM-JETIA","raw_type":"journal-article"},{"id":"pmh:oai:doaj.org/article:f4023971fcd2475091e0899972fc70d3","doi":null,"is_oa":false,"landing_page_url":"https://doaj.org/article/f4023971fcd2475091e0899972fc70d3","pdf_url":null,"source":{"id":"https://openalex.org/S4306401280","display_name":"DOAJ (DOAJ: Directory of Open Access Journals)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"ITEGAM-JETIA, Vol 12, Iss 60 (2026)","raw_type":"article"}],"best_oa_location":{"id":"doi:10.5935/jetia.v12i60.4036","doi":"https://doi.org/10.5935/jetia.v12i60.4036","is_oa":true,"landing_page_url":"https://doi.org/10.5935/jetia.v12i60.4036","pdf_url":null,"source":{"id":"https://openalex.org/S2764766405","display_name":"ITEGAM- Journal of Engineering and Technology for Industrial Applications (ITEGAM-JETIA)","issn_l":"2447-0228","issn":["2447-0228"],"is_oa":true,"is_in_doaj":true,"is_core":false,"listed_in":["doaj"],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"ITEGAM- Journal of Engineering and Technology for Industrial Applications (ITEGAM-JETIA","raw_type":"journal-article"},"sustainable_development_goals":[],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W2893543720","https://openalex.org/W2791718239","https://openalex.org/W2089689156","https://openalex.org/W3116131981","https://openalex.org/W2567700246","https://openalex.org/W2954138588","https://openalex.org/W2137030644","https://openalex.org/W4390506225","https://openalex.org/W1977093768","https://openalex.org/W4391666884"],"abstract_inverted_index":{"Sweep":[0],"Frequency":[1],"Response":[2],"Analysis":[3],"(SFRA)":[4],"serves":[5],"as":[6],"a":[7,31,35,72,112,141,154],"highly":[8],"sensitive":[9],"diagnostic":[10],"technique":[11],"for":[12,119,174],"identifying":[13],"mechanical":[14,165],"deformations":[15],"within":[16,140],"power":[17,77],"transformer":[18,118],"windings.":[19,52],"The":[20,122,145],"inherent":[21],"magnetic":[22,81],"and":[23,62,82,100,133,177],"capacitive":[24,83],"inter-winding":[25],"couplings":[26],"in":[27,106,130],"transformers":[28],"mean":[29],"that":[30],"fault":[32,175],"localized":[33],"to":[34,88,138,150,160],"single":[36,142,155],"winding":[37,110,156],"can":[38],"propagate":[39],"detectable":[40],"anomalies":[41],"across":[42],"the":[43,48,90,107,162],"frequency":[44,124],"responses":[45],"observed":[46],"at":[47],"terminals":[49],"of":[50,71,111,164,169],"all":[51],"This":[53],"study":[54,146],"systematically":[55],"explores":[56],"this":[57],"interdependency":[58],"through":[59],"detailed":[60],"simulations":[61],"case":[63],"studies.":[64],"A":[65],"comprehensive":[66],"six-winding":[67],"equivalent":[68],"circuit":[69],"model":[70],"40":[73],"MVA,":[74,114],"132/11":[75],"kV":[76,116],"transformer,":[78],"incorporating":[79],"both":[80,131],"coupling":[84],"effects":[85],"is":[86,158],"simulated":[87],"validate":[89],"underlying":[91],"hypothesis.":[92],"Complementing":[93],"this,":[94],"faults":[95,139],"comprising":[96],"an":[97],"open-circuit":[98],"condition":[99],"radial":[101],"buckling":[102],"were":[103],"deliberately":[104],"induced":[105],"low-voltage":[108],"(LV)":[109],"20":[113],"66/11":[115],"oil-immersed":[117],"experimental":[120],"validation.":[121],"resultant":[123],"response":[125],"traces":[126],"reveal":[127],"pronounced":[128],"deviations":[129],"LV":[132],"high-voltage":[134],"(HV)":[135],"signatures":[136,171],"attributable":[137],"phase":[143],"winding.":[144],"concludes":[147],"that,":[148],"due":[149],"unavoidable":[151],"coupling,":[152],"analyzing":[153],"signature":[157],"sufficient":[159],"ensure":[161],"presence":[163],"deformation,":[166],"whereas":[167],"comparison":[168],"multiple":[170],"retains":[172],"value":[173],"localization":[176],"severity":[178],"assessment.":[179]},"counts_by_year":[],"updated_date":"2026-11-13T13:42:25.865203","created_date":"2026-08-28T00:00:00"}