{"id":"https://openalex.org/W7204209701","doi":"https://doi.org/10.51483/ijaiml.6.2.2026.229-242","title":"Design And Analysis Of An Integrated Dq-Frame Control Strategy For Three-Phase Grid-Connected PV Systems","display_name":"Design And Analysis Of An Integrated Dq-Frame Control Strategy For Three-Phase Grid-Connected PV Systems","publication_year":2026,"publication_date":"2026-01-01","ids":{"openalex":"https://openalex.org/W7204209701","doi":"https://doi.org/10.51483/ijaiml.6.2.2026.229-242"},"language":"en","primary_location":{"id":"doi:10.51483/ijaiml.6.2.2026.229-242","doi":"https://doi.org/10.51483/ijaiml.6.2.2026.229-242","is_oa":true,"landing_page_url":"https://doi.org/10.51483/ijaiml.6.2.2026.229-242","pdf_url":"https://www.svedbergopen.com/index.php/ijaiml/article/download/1159/789","source":{"id":"https://openalex.org/S4386621846","display_name":"International Journal of Artificial Intelligence and Machine Learning","issn_l":"2789-2557","issn":["2789-2557"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core"],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"International Journal of Artificial Intelligence and Machine Learning","raw_type":"journal-article"},"volume":null,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"hybrid","oa_url":"https://www.svedbergopen.com/index.php/ijaiml/article/download/1159/789","any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5062981888","display_name":"Vishal G. Jotangiya","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I137674396","display_name":"RK University","ror":"https://ror.org/057ap5t09","country_code":"IN","type":"education","lineage":["https://openalex.org/I137674396"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Vishal G Jotangiya","raw_affiliation_strings":["Research Scholar , Department of Electrical Engineering , RK University , Rajkot- 360020 , Gujarat , India;"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Research Scholar , Department of Electrical Engineering , RK University , Rajkot- 360020 , Gujarat , India;","institution_ids":["https://openalex.org/I137674396"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5073294975","display_name":"Riaz Kurbanali Israni","orcid":"https://orcid.org/0000-0001-7185-4132","observed_orcids":["https://orcid.org/0000-0001-7185-4132"]},"institutions":[{"id":"https://openalex.org/I137674396","display_name":"RK University","ror":"https://ror.org/057ap5t09","country_code":"IN","type":"education","lineage":["https://openalex.org/I137674396"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Riaz K Israni","raw_affiliation_strings":["Associate Professor, Department of Electrical Engineering , RK University , Rajkot- 360020 , Gujarat , India;"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Associate Professor, Department of Electrical Engineering , RK University , Rajkot- 360020 , Gujarat , India;","institution_ids":["https://openalex.org/I137674396"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5069912207","display_name":"Chirag Parekh","orcid":"https://orcid.org/0000-0003-4038-0522","observed_orcids":["https://orcid.org/0000-0003-4038-0522"]},"institutions":[{"id":"https://openalex.org/I137674396","display_name":"RK University","ror":"https://ror.org/057ap5t09","country_code":"IN","type":"education","lineage":["https://openalex.org/I137674396"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Chiragkumar Parekh","raw_affiliation_strings":["Professor, Department of Electrical Engineering , RK University , Rajkot- 360020 , Gujarat , India;"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Professor, Department of Electrical Engineering , RK University , Rajkot- 360020 , Gujarat , India;","institution_ids":["https://openalex.org/I137674396"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5048116611","display_name":"Parin H. Chauhan","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Parin H Chauhan","raw_affiliation_strings":["Assistant Professor, Electrical Engineering Department , Lukhdhirji Engineering College , Morbi- 363642 , Gujarat , India;"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Assistant Professor, Electrical Engineering Department , Lukhdhirji Engineering College , Morbi- 363642 , Gujarat , India;","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":true,"cited_by_count":0,"citation_normalized_percentile":{"value":0.0,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"6","issue":"2","first_page":"229","last_page":"242"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.739300012588501,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.739300012588501,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10468","display_name":"Photovoltaic System Optimization Techniques","score":0.14820000529289246,"subfield":{"id":"https://openalex.org/subfields/2105","display_name":"Renewable Energy, Sustainability and the Environment"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10228","display_name":"Multilevel Inverters and Converters","score":0.02879999950528145,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/dq-frame-control","display_name":"dq-frame control","score":0.9860000014305115},{"id":"https://openalex.org/keywords/photovoltaic-inverter","display_name":"photovoltaic inverter","score":0.8109999895095825},{"id":"https://openalex.org/keywords/active-and-reactive-power-control","display_name":"active and reactive power control","score":0.8600000143051147},{"id":"https://openalex.org/keywords/reference-current-generation","display_name":"reference current generation","score":0.9089999794960022},{"id":"https://openalex.org/keywords/current-control-loop","display_name":"current loop control","score":0.6980000138282776},{"id":"https://openalex.org/keywords/point-of-common-coupling","display_name":"point of common coupling","score":0.8349999785423279},{"id":"https://openalex.org/keywords/power-factor-control","display_name":"power factor control","score":0.699999988079071},{"id":"https://openalex.org/keywords/reactive-power-compensation","display_name":"reactive power compensation","score":0.996999979019165},{"id":"https://openalex.org/keywords/grid-synchronization","display_name":"grid synchronization","score":0.9789999723434448},{"id":"https://openalex.org/keywords/grid-integration","display_name":"grid integration","score":0.5429999828338623}],"concepts":[{"id":"https://openalex.org/C108755667","wikidata":"https://www.wikidata.org/wiki/Q1930258","display_name":"AC power","level":3,"score":0.739799976348877},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.60589998960495},{"id":"https://openalex.org/C41291067","wikidata":"https://www.wikidata.org/wiki/Q1897785","display_name":"Photovoltaic system","level":2,"score":0.5763999819755554},{"id":"https://openalex.org/C36139824","wikidata":"https://www.wikidata.org/wiki/Q1052007","display_name":"Maximum power point tracking","level":4,"score":0.5626000165939331},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.5559999942779541},{"id":"https://openalex.org/C203479927","wikidata":"https://www.wikidata.org/wiki/Q5165939","display_name":"Controller (irrigation)","level":2,"score":0.48910000920295715},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.486299991607666},{"id":"https://openalex.org/C56685638","wikidata":"https://www.wikidata.org/wiki/Q2300474","display_name":"Power control","level":3,"score":0.4860000014305115},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4844000041484833},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.4731000065803528},{"id":"https://openalex.org/C2778562939","wikidata":"https://www.wikidata.org/wiki/Q1298791","display_name":"Synchronization (alternating current)","level":3,"score":0.4620000123977661},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.4503999948501587},{"id":"https://openalex.org/C64424096","wikidata":"https://www.wikidata.org/wiki/Q750454","display_name":"Power factor","level":3,"score":0.39010000228881836},{"id":"https://openalex.org/C195697387","wikidata":"https://www.wikidata.org/wiki/Q5608561","display_name":"Grid-connected photovoltaic power system","level":5,"score":0.3801000118255615},{"id":"https://openalex.org/C11190779","wikidata":"https://www.wikidata.org/wiki/Q664575","display_name":"Inverter","level":3,"score":0.3779999911785126},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.36550000309944153},{"id":"https://openalex.org/C112972136","wikidata":"https://www.wikidata.org/wiki/Q7595718","display_name":"Stability (learning theory)","level":2,"score":0.3325999975204468},{"id":"https://openalex.org/C17500928","wikidata":"https://www.wikidata.org/wiki/Q959968","display_name":"Control system","level":2,"score":0.32589998841285706},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.30630001425743103},{"id":"https://openalex.org/C45872418","wikidata":"https://www.wikidata.org/wiki/Q5318966","display_name":"Dynamic demand","level":3,"score":0.2937000095844269},{"id":"https://openalex.org/C59407501","wikidata":"https://www.wikidata.org/wiki/Q550341","display_name":"Volt-ampere reactive","level":5,"score":0.28949999809265137},{"id":"https://openalex.org/C31531917","wikidata":"https://www.wikidata.org/wiki/Q915157","display_name":"Robust control","level":3,"score":0.27869999408721924},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.2705000042915344}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.51483/ijaiml.6.2.2026.229-242","doi":"https://doi.org/10.51483/ijaiml.6.2.2026.229-242","is_oa":true,"landing_page_url":"https://doi.org/10.51483/ijaiml.6.2.2026.229-242","pdf_url":"https://www.svedbergopen.com/index.php/ijaiml/article/download/1159/789","source":{"id":"https://openalex.org/S4386621846","display_name":"International Journal of Artificial Intelligence and Machine Learning","issn_l":"2789-2557","issn":["2789-2557"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core"],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"International Journal of Artificial Intelligence and Machine Learning","raw_type":"journal-article"}],"best_oa_location":{"id":"doi:10.51483/ijaiml.6.2.2026.229-242","doi":"https://doi.org/10.51483/ijaiml.6.2.2026.229-242","is_oa":true,"landing_page_url":"https://doi.org/10.51483/ijaiml.6.2.2026.229-242","pdf_url":"https://www.svedbergopen.com/index.php/ijaiml/article/download/1159/789","source":{"id":"https://openalex.org/S4386621846","display_name":"International Journal of Artificial Intelligence and Machine Learning","issn_l":"2789-2557","issn":["2789-2557"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core"],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"International Journal of Artificial Intelligence and Machine Learning","raw_type":"journal-article"},"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","score":0.9853000044822693,"display_name":"Affordable and clean energy"},{"id":"https://metadata.un.org/sdg/9","score":0.7207000255584717,"display_name":"Industry, innovation and infrastructure"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":true,"pdf":true},"content_urls":{"pdf":"https://content.openalex.org/works/W7204209701.pdf","grobid_xml":"https://content.openalex.org/works/W7204209701.grobid-xml"},"referenced_works_count":10,"referenced_works":["https://openalex.org/W1966172613","https://openalex.org/W2103965176","https://openalex.org/W2132628627","https://openalex.org/W2135302867","https://openalex.org/W2169498704","https://openalex.org/W2541459946","https://openalex.org/W3111660340","https://openalex.org/W4390190180","https://openalex.org/W4400561479","https://openalex.org/W4401048503"],"related_works":["https://openalex.org/W7141738248","https://openalex.org/W7125969721","https://openalex.org/W1522111882","https://openalex.org/W4236779931","https://openalex.org/W4403329703","https://openalex.org/W2371566025","https://openalex.org/W2093233894","https://openalex.org/W7168157984","https://openalex.org/W2164430554","https://openalex.org/W2579751257"],"abstract_inverted_index":{"To":[0],"enhance":[1],"the":[2,38,76,82,94,98,119,136,152,155],"grid":[3,68,100,127,145],"integration":[4],"of":[5,24,78,88,138,154,160],"single-stage,":[6],"three-phase":[7],"photovoltaic":[8],"(PV)":[9],"systems,":[10],"this":[11],"paper":[12,134],"proposes":[13],"a":[14,54],"robust":[15],"dq-frame":[16],"control":[17,31,57,83,125],"scheme":[18],"for":[19,126],"independent":[20],"and":[21,26,43,64,90,97,109,129,144,166],"precise":[22],"regulation":[23],"active":[25,40,89],"reactive":[27,44,91,130],"power.":[28],"The":[29,133],"proposed":[30,156],"algorithm":[32],"generates":[33],"reference":[34,139],"currents":[35],"directly":[36],"from":[37],"desired":[39],"power":[41,45,47,92,111,117,123,131,164],"(P)":[42],"(Q)":[46],"commands,":[48],"which":[49],"are":[50,73],"then":[51],"tracked":[52],"by":[53],"dedicated":[55],"current":[56,140],"loop":[58],"to":[59,102,115],"ensure":[60],"fast":[61,161],"dynamic":[62],"response":[63],"improved":[65],"stability":[66,108],"under":[67],"disturbances.":[69],"When":[70],"local":[71],"loads":[72],"connected":[74],"at":[75],"point":[77],"common":[79],"coupling":[80],"(PCC),":[81],"strategy":[84],"enables":[85],"effective":[86],"sharing":[87],"between":[93],"PV":[95],"inverter":[96],"utility":[99],"according":[101],"predefined":[103],"references,":[104],"thereby":[105],"maintaining":[106],"voltage":[107],"reliable":[110],"delivery.":[112],"In":[113],"addition":[114],"basic":[116],"injection,":[118],"framework":[120],"supports":[121],"flexible":[122],"factor":[124],"support":[128],"compensation.":[132],"presents":[135],"formulation":[137],"generation,":[141],"controller":[142],"design,":[143],"synchronization":[146],"methodology.":[147],"MATLAB/Simulink":[148],"simulation":[149],"results":[150],"validate":[151],"effectiveness":[153],"approach":[157],"in":[158],"terms":[159],"response,":[162],"accurate":[163],"tracking,":[165],"enhanced":[167],"operational":[168],"reliability.":[169]},"counts_by_year":[],"updated_date":"2026-11-04T10:54:05.112534","created_date":"2026-08-26T00:00:00"}
