{"id":"https://openalex.org/W7203600712","doi":"https://doi.org/10.83144/pcns.vi.3001","title":"Assessment of Fuel Fitness for Service Following Standing Start Process During Gentilly-2 Annual Outage","display_name":"Assessment of Fuel Fitness for Service Following Standing Start Process During Gentilly-2 Annual Outage","publication_year":2024,"publication_date":"2024-12-12","ids":{"openalex":"https://openalex.org/W7203600712","doi":"https://doi.org/10.83144/pcns.vi.3001"},"language":"en","primary_location":{"id":"doi:10.83144/pcns.vi.3001","doi":"https://doi.org/10.83144/pcns.vi.3001","is_oa":true,"landing_page_url":"https://doi.org/10.83144/pcns.vi.3001","pdf_url":null,"source":{"id":"https://openalex.org/S7407063483","display_name":"Canadian Nuclear Society Proceedings","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"JournalArticle"},"volume":null,"type":"article","is_traditional":true,"indexed_in":["datacite"],"open_access":{"is_oa":true,"oa_status":"bronze","oa_url":"https://doi.org/10.83144/pcns.vi.3001","any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5052783814","display_name":"Q.M. Lei","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I69816183","display_name":"Atomic Energy (Canada)","ror":"https://ror.org/019ja9e37","country_code":"CA","type":"company","lineage":["https://openalex.org/I69816183"]}],"countries":["CA"],"is_corresponding":false,"raw_author_name":"Lei, Q.M.","raw_affiliation_strings":["Atomic Energy of Canada Limited"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Atomic Energy of Canada Limited","institution_ids":["https://openalex.org/I69816183"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5147373547","display_name":"P. Gulshani","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I47099075","display_name":"Hydro-Qu\u00e9bec","ror":"https://ror.org/01nhzsw25","country_code":"CA","type":"government","lineage":["https://openalex.org/I47099075"]}],"countries":["CA"],"is_corresponding":false,"raw_author_name":"Gulshani, P.","raw_affiliation_strings":["Hydro Quebec"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Hydro Quebec","institution_ids":["https://openalex.org/I47099075"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5147356968","display_name":"H. Huynh","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I47099075","display_name":"Hydro-Qu\u00e9bec","ror":"https://ror.org/01nhzsw25","country_code":"CA","type":"government","lineage":["https://openalex.org/I47099075"]}],"countries":["CA"],"is_corresponding":false,"raw_author_name":"Huynh, H.","raw_affiliation_strings":["Hydro Quebec"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Hydro Quebec","institution_ids":["https://openalex.org/I47099075"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.34883287,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T12560","display_name":"Nuclear Engineering Thermal-Hydraulics","score":0.7904999852180481,"subfield":{"id":"https://openalex.org/subfields/2104","display_name":"Nuclear Energy and Engineering"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T12560","display_name":"Nuclear Engineering Thermal-Hydraulics","score":0.7904999852180481,"subfield":{"id":"https://openalex.org/subfields/2104","display_name":"Nuclear Energy and Engineering"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11242","display_name":"Nuclear Materials and Properties","score":0.10830000042915344,"subfield":{"id":"https://openalex.org/subfields/2505","display_name":"Materials Chemistry"},"field":{"id":"https://openalex.org/fields/25","display_name":"Materials Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10597","display_name":"Nuclear reactor physics and engineering","score":0.04500000178813934,"subfield":{"id":"https://openalex.org/subfields/2104","display_name":"Nuclear Energy and Engineering"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/standing-start","display_name":"standing start","score":0.5529999732971191},{"id":"https://openalex.org/keywords/decay-heat-removal","display_name":"decay heat removal","score":0.9089999794960022}],"concepts":[{"id":"https://openalex.org/C91914117","wikidata":"https://www.wikidata.org/wiki/Q1056832","display_name":"Coolant","level":2,"score":0.5706999897956848},{"id":"https://openalex.org/C150328934","wikidata":"https://www.wikidata.org/wiki/Q1662393","display_name":"Decay heat","level":2,"score":0.5641000270843506},{"id":"https://openalex.org/C186937647","wikidata":"https://www.wikidata.org/wiki/Q1796959","display_name":"Heat sink","level":2,"score":0.5410000085830688},{"id":"https://openalex.org/C116915560","wikidata":"https://www.wikidata.org/wiki/Q83504","display_name":"Nuclear engineering","level":1,"score":0.5370000004768372},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.4359000027179718},{"id":"https://openalex.org/C2779095084","wikidata":"https://www.wikidata.org/wiki/Q3679502","display_name":"Piping","level":2,"score":0.38100001215934753},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3361000120639801},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.3287999927997589},{"id":"https://openalex.org/C2780799671","wikidata":"https://www.wikidata.org/wiki/Q17087362","display_name":"Transient (computer programming)","level":2,"score":0.3240000009536743},{"id":"https://openalex.org/C2780945871","wikidata":"https://www.wikidata.org/wiki/Q194274","display_name":"Backup","level":2,"score":0.30640000104904175},{"id":"https://openalex.org/C50517652","wikidata":"https://www.wikidata.org/wiki/Q179635","display_name":"Heat transfer","level":2,"score":0.30480000376701355},{"id":"https://openalex.org/C194945478","wikidata":"https://www.wikidata.org/wiki/Q5693253","display_name":"Heat capacity rate","level":4,"score":0.2944999933242798},{"id":"https://openalex.org/C7694927","wikidata":"https://www.wikidata.org/wiki/Q7667810","display_name":"Water cooling","level":2,"score":0.28189998865127563},{"id":"https://openalex.org/C103208741","wikidata":"https://www.wikidata.org/wiki/Q1675349","display_name":"Service life","level":2,"score":0.26919999718666077},{"id":"https://openalex.org/C174379495","wikidata":"https://www.wikidata.org/wiki/Q3523888","display_name":"Thermal hydraulics","level":3,"score":0.2685000002384186},{"id":"https://openalex.org/C3020116064","wikidata":"https://www.wikidata.org/wiki/Q11473","display_name":"Heat generation","level":2,"score":0.26409998536109924},{"id":"https://openalex.org/C9526370","wikidata":"https://www.wikidata.org/wiki/Q308881","display_name":"Fuel injection","level":2,"score":0.2549999952316284},{"id":"https://openalex.org/C29700514","wikidata":"https://www.wikidata.org/wiki/Q634340","display_name":"Heat transfer coefficient","level":3,"score":0.2540999948978424},{"id":"https://openalex.org/C57879066","wikidata":"https://www.wikidata.org/wiki/Q41217","display_name":"Mechanics","level":1,"score":0.25099998712539673}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.83144/pcns.vi.3001","doi":"https://doi.org/10.83144/pcns.vi.3001","is_oa":true,"landing_page_url":"https://doi.org/10.83144/pcns.vi.3001","pdf_url":null,"source":{"id":"https://openalex.org/S7407063483","display_name":"Canadian Nuclear Society Proceedings","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"JournalArticle"}],"best_oa_location":{"id":"doi:10.83144/pcns.vi.3001","doi":"https://doi.org/10.83144/pcns.vi.3001","is_oa":true,"landing_page_url":"https://doi.org/10.83144/pcns.vi.3001","pdf_url":null,"source":{"id":"https://openalex.org/S7407063483","display_name":"Canadian Nuclear Society Proceedings","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"JournalArticle"},"sustainable_development_goals":[{"display_name":"Affordable and clean energy","score":0.878000020980835,"id":"https://metadata.un.org/sdg/7"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W7203596318","https://openalex.org/W7203640200","https://openalex.org/W2546182535","https://openalex.org/W121627115","https://openalex.org/W7203603589","https://openalex.org/W7221547458","https://openalex.org/W1977700910","https://openalex.org/W7203604201","https://openalex.org/W1966030723","https://openalex.org/W2898330389"],"abstract_inverted_index":{"During":[0],"a":[1,116,221,304,312],"planned":[2],"annual":[3],"outage":[4],"at":[5,365],"Gentilly":[6],"2,":[7],"primary":[8,22],"and":[9,60,66,95,134,162,193,209,224,244,254,260,271,349],"back-up":[10,107],"heat":[11,18,23,37,45,48,52,83,86,108],"sinks":[12],"are":[13,147,251,265,353],"provided":[14,26,55],"for":[15,121,183,202,216,226,241,295,355],"removing":[16],"decay":[17,44,82],"from":[19],"fuel.":[20],"The":[21,50,88,176],"sink":[24,53,109],"is":[25,54,110,156,167,287,321],"by":[27,56,275],"either":[28],"the":[29,33,43,67,75,81,106,132,150,152,163,179,185,190,199,204,210,228,233,268,272,276,292,316,324,340,343,347,350,366],"steam":[30,68],"generators":[31],"or":[32,77,129],"shutdown":[34,313],"cooling":[35],"system":[36],"exchangers.":[38],"Forced":[39],"coolant":[40,57,76,308],"flow":[41,72],"transports":[42,80],"to":[46,84,123,140,158,169,247,249,357],"these":[47,85,338],"sinks.":[49,87],"backup":[51],"subcooling,":[58],"end-shield":[59],"moderator":[61],"coolants,":[62],"piping":[63],"metal":[64],"mass.":[65],"generators.":[69],"Intermittent":[70],"buoyancy-induced":[71],"(IBIF)":[73],"of":[74,118,187,198,220,232,238,306,342],"standing-start":[78],"process":[79],"analysis":[89,114,130,177,344],"in":[90,149,173,196,311],"this":[91],"paper":[92],"assesses":[93],"fuel":[94,96,135,153,222,234,242,258,283,296,317,348,351],"channel":[97,352],"fitness-for-service":[98],"after":[99,131,360],"repeated":[100,141,361],"standing":[101],"start":[102],"cycles":[103],"when":[104],"only":[105],"assumed":[111],"available.":[112],"This":[113,289],"defines":[115,291],"set":[117,237],"suitable":[119,354],"conditions":[120,219],"return":[122,248],"full-power":[124],"operation,":[125],"without":[126],"any":[127],"inspection":[128],"fie1":[133],"channels":[136],"have":[137],"been":[138],"subjected":[139],"1BIF":[142],"cycles.":[143,175,336,363],"Two":[144],"temperature":[145,155,166,192,213,269,285,319,327],"limits":[146,270],"used":[148],"analysis:":[151],"sheath":[154,259,284,297,318],"limited":[157,168],"450":[159,280,300],"degrees":[160,171,281,301,332],"C,":[161],"pressure":[164,211,245,261,325],"tube":[165,212,262,326],"400":[170,331],"C":[172,282,302,333],"IBIF":[174,188,335,362],"uses":[178],"computer":[180,277],"programs":[181],"THERMOSS-111":[182],"calculating":[184,203],"number":[186],"cycles,":[189,200],"channel-coolant":[191],"heatup":[194],"times":[195],"each":[197],"HOTSPOT":[201],"transient":[205,229],"sheath-to-coolant":[206],"heat-transfer":[207],"coefficient":[208],"transient,":[214],"ELESTRES":[215],"generating":[217],"initial":[218],"element,":[223],"ELOCA.Mk6":[225],"assessing":[227],"thermal-mechanical":[230],"behaviour":[231],"element.":[235],"A":[236,279],"stringent":[239],"criteria":[240],"bundles":[243],"tubes":[246],"service":[250],"defined,":[252],"justified,":[253],"examined.":[255],"Whenever":[256],"possible,":[257],"degradation":[263],"mechanisms":[264],"quantified":[266],"using":[267],"results":[273,341],"calculated":[274],"codes.":[278],"map":[286,290],"constructed.":[288],"operation":[293],"envelope":[294],"remaining":[298],"below":[299,330],"should":[303],"loss":[305],"forced":[307],"circulation":[309],"occur":[310],"state.":[314],"If":[315],"limit":[320],"not":[322],"exceeded,":[323],"will":[328],"be":[329],"during":[334],"With":[337],"limits,":[339],"show":[345],"that":[346],"returning":[356],"full":[358],"power":[359],"Presented":[364],"19Ih":[367],"Annual":[368],"CNS":[369],"Conference,":[370],"Toronto,":[371],"October":[372],"18-21,":[373],"1998.":[374]},"counts_by_year":[],"updated_date":"2026-09-25T08:18:29.962427","created_date":"2026-08-18T00:00:00"}