{"id":"https://openalex.org/W7203580992","doi":"https://doi.org/10.36948/ijfmr.2026.v08i04.85875","title":"Optimization of Auxiliary Power Consumption in Supercritical Thermal Power Plant Using Six Sigma DMAIC Methodologies","display_name":"Optimization of Auxiliary Power Consumption in Supercritical Thermal Power Plant Using Six Sigma DMAIC Methodologies","publication_year":2026,"publication_date":"2026-08-16","ids":{"openalex":"https://openalex.org/W7203580992","doi":"https://doi.org/10.36948/ijfmr.2026.v08i04.85875"},"language":"en","primary_location":{"id":"doi:10.36948/ijfmr.2026.v08i04.85875","doi":"https://doi.org/10.36948/ijfmr.2026.v08i04.85875","is_oa":true,"landing_page_url":"https://doi.org/10.36948/ijfmr.2026.v08i04.85875","pdf_url":"https://www.ijfmr.com/papers/2026/4/85875.pdf","source":{"id":"https://openalex.org/S4210207214","display_name":"International Journal For Multidisciplinary Research","issn_l":"2582-2160","issn":["2582-2160"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":"cc-by-sa","license_id":"https://openalex.org/licenses/cc-by-sa","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"International Journal For Multidisciplinary Research","raw_type":"journal-article"},"volume":null,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"hybrid","oa_url":"https://www.ijfmr.com/papers/2026/4/85875.pdf","any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5147278647","display_name":"S Lingamaiah","orcid":"https://orcid.org/0009-0009-4326-056X","observed_orcids":["https://orcid.org/0009-0009-4326-056X"]},"institutions":[{"id":"https://openalex.org/I4405254720","display_name":"B.E.S.T Innovation University","ror":"https://ror.org/025e1z063","country_code":"IN","type":"education","lineage":["https://openalex.org/I4405254720"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"S Lingamaiah","raw_affiliation_strings":["Research Scholar , BESTIU , Assistant Professor (Adhoc) SKUCET Anantapuramu , India"],"raw_orcid":"https://orcid.org/0009-0009-4326-056X","affiliations":[{"raw_affiliation_string":"Research Scholar , BESTIU , Assistant Professor (Adhoc) SKUCET Anantapuramu , India","institution_ids":["https://openalex.org/I4405254720"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5147290416","display_name":"Repana Ramachandra","orcid":"https://orcid.org/0009-0005-1785-9692","observed_orcids":["https://orcid.org/0009-0005-1785-9692"]},"institutions":[{"id":"https://openalex.org/I4031970","display_name":"Sri Krishnadevaraya University","ror":"https://ror.org/02fyxjb45","country_code":"IN","type":"education","lineage":["https://openalex.org/I4031970"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Repana Ramachandra","raw_affiliation_strings":["Principal , SKUCET , S.K.University Anantapuramu , India"],"raw_orcid":"https://orcid.org/0009-0005-1785-9692","affiliations":[{"raw_affiliation_string":"Principal , SKUCET , S.K.University Anantapuramu , India","institution_ids":["https://openalex.org/I4031970"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":true,"cited_by_count":0,"citation_normalized_percentile":{"value":0.0,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"8","issue":"4","first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T13856","display_name":"Advanced Power Generation Technologies","score":0.8403000235557556,"subfield":{"id":"https://openalex.org/subfields/2102","display_name":"Energy Engineering and Power Technology"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T13856","display_name":"Advanced Power Generation Technologies","score":0.8403000235557556,"subfield":{"id":"https://openalex.org/subfields/2102","display_name":"Energy Engineering and Power Technology"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11954","display_name":"Energy Efficiency and Management","score":0.07240000367164612,"subfield":{"id":"https://openalex.org/subfields/2105","display_name":"Renewable Energy, Sustainability and the Environment"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10568","display_name":"Thermodynamic and Exergetic Analyses of Power and Cooling Systems","score":0.05869999900460243,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/auxiliary-power-consumption","display_name":"auxiliary power consumption","score":0.9990000128746033},{"id":"https://openalex.org/keywords/six-sigma-dmaic","display_name":"Six Sigma DMAIC","score":0.8730000257492065},{"id":"https://openalex.org/keywords/boiler-feed-pumps","display_name":"boiler feed pumps","score":0.8539999723434448},{"id":"https://openalex.org/keywords/induced-draft-fan","display_name":"induced draft fan","score":0.8619999885559082},{"id":"https://openalex.org/keywords/forced-draft-fan","display_name":"forced draft fan","score":0.9129999876022339},{"id":"https://openalex.org/keywords/cooling-water-pump","display_name":"cooling water pump","score":0.8899999856948853},{"id":"https://openalex.org/keywords/coal-mill","display_name":"coal mill","score":0.8610000014305115},{"id":"https://openalex.org/keywords/combustion-optimization","display_name":"combustion optimization","score":0.8999999761581421},{"id":"https://openalex.org/keywords/condenser-vacuum","display_name":"condenser vacuum","score":0.7310000061988831},{"id":"https://openalex.org/keywords/low-pressure-heater","display_name":"low-pressure heater","score":0.8399999737739563},{"id":"https://openalex.org/keywords/high-pressure-heater","display_name":"high-pressure heater","score":0.7509999871253967},{"id":"https://openalex.org/keywords/energy-efficiency","display_name":"energy efficiency","score":0.8289999961853027},{"id":"https://openalex.org/keywords/operational-cost-reduction","display_name":"operational cost reduction","score":0.847000002861023}],"concepts":[{"id":"https://openalex.org/C205400985","wikidata":"https://www.wikidata.org/wiki/Q380179","display_name":"DMAIC","level":4,"score":0.6543999910354614},{"id":"https://openalex.org/C118419359","wikidata":"https://www.wikidata.org/wiki/Q682585","display_name":"Supercritical fluid","level":2,"score":0.6029000282287598},{"id":"https://openalex.org/C2039551","wikidata":"https://www.wikidata.org/wiki/Q200297","display_name":"Thermal power station","level":2,"score":0.5946999788284302},{"id":"https://openalex.org/C2780013297","wikidata":"https://www.wikidata.org/wiki/Q19596153","display_name":"Boiler (water heating)","level":2,"score":0.5782999992370605},{"id":"https://openalex.org/C21880701","wikidata":"https://www.wikidata.org/wiki/Q2144042","display_name":"Process engineering","level":1,"score":0.5145000219345093},{"id":"https://openalex.org/C161511644","wikidata":"https://www.wikidata.org/wiki/Q908333","display_name":"Auxiliary power unit","level":3,"score":0.507099986076355},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.4950999915599823},{"id":"https://openalex.org/C4311470","wikidata":"https://www.wikidata.org/wiki/Q159719","display_name":"Power station","level":2,"score":0.4733999967575073},{"id":"https://openalex.org/C2780934509","wikidata":"https://www.wikidata.org/wiki/Q571589","display_name":"Condenser (optics)","level":3,"score":0.4652000069618225},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.4571000039577484},{"id":"https://openalex.org/C2780165032","wikidata":"https://www.wikidata.org/wiki/Q16869822","display_name":"Energy consumption","level":2,"score":0.4009999930858612},{"id":"https://openalex.org/C50406533","wikidata":"https://www.wikidata.org/wiki/Q1452104","display_name":"Thermal efficiency","level":3,"score":0.39100000262260437},{"id":"https://openalex.org/C2778368411","wikidata":"https://www.wikidata.org/wiki/Q24662","display_name":"Retrofitting","level":2,"score":0.3684000074863434},{"id":"https://openalex.org/C23119410","wikidata":"https://www.wikidata.org/wiki/Q236908","display_name":"Six Sigma","level":3,"score":0.3644999861717224},{"id":"https://openalex.org/C45882903","wikidata":"https://www.wikidata.org/wiki/Q5042317","display_name":"Fuel efficiency","level":2,"score":0.36070001125335693},{"id":"https://openalex.org/C132646400","wikidata":"https://www.wikidata.org/wiki/Q929429","display_name":"Internal combustion engine cooling","level":4,"score":0.33970001339912415},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.3278000056743622},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.3197000026702881},{"id":"https://openalex.org/C107861326","wikidata":"https://www.wikidata.org/wiki/Q209233","display_name":"Thermal energy","level":2,"score":0.31619998812675476},{"id":"https://openalex.org/C204530211","wikidata":"https://www.wikidata.org/wiki/Q752823","display_name":"Thermal","level":2,"score":0.3077000081539154},{"id":"https://openalex.org/C105923489","wikidata":"https://www.wikidata.org/wiki/Q133235","display_name":"Combustion","level":2,"score":0.29089999198913574},{"id":"https://openalex.org/C73673526","wikidata":"https://www.wikidata.org/wiki/Q1158818","display_name":"Steam-electric power station","level":4,"score":0.28690001368522644},{"id":"https://openalex.org/C16057445","wikidata":"https://www.wikidata.org/wiki/Q44494","display_name":"Mill","level":2,"score":0.2858999967575073},{"id":"https://openalex.org/C423512","wikidata":"https://www.wikidata.org/wiki/Q383973","display_name":"Electricity generation","level":3,"score":0.2851000130176544},{"id":"https://openalex.org/C186868685","wikidata":"https://www.wikidata.org/wiki/Q1759095","display_name":"Air preheater","level":2,"score":0.27959999442100525},{"id":"https://openalex.org/C106169591","wikidata":"https://www.wikidata.org/wiki/Q909434","display_name":"Combustion chamber","level":3,"score":0.2757999897003174},{"id":"https://openalex.org/C2742236","wikidata":"https://www.wikidata.org/wiki/Q924713","display_name":"Efficient energy use","level":2,"score":0.2709999978542328},{"id":"https://openalex.org/C511840579","wikidata":"https://www.wikidata.org/wiki/Q12757","display_name":"Internal combustion engine","level":2,"score":0.2709999978542328},{"id":"https://openalex.org/C2984118289","wikidata":"https://www.wikidata.org/wiki/Q29954","display_name":"Power consumption","level":3,"score":0.26510000228881836},{"id":"https://openalex.org/C2778139897","wikidata":"https://www.wikidata.org/wiki/Q6509447","display_name":"Lean Six Sigma","level":4,"score":0.2590000033378601},{"id":"https://openalex.org/C548081761","wikidata":"https://www.wikidata.org/wiki/Q180388","display_name":"Waste management","level":1,"score":0.2574000060558319}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.36948/ijfmr.2026.v08i04.85875","doi":"https://doi.org/10.36948/ijfmr.2026.v08i04.85875","is_oa":true,"landing_page_url":"https://doi.org/10.36948/ijfmr.2026.v08i04.85875","pdf_url":"https://www.ijfmr.com/papers/2026/4/85875.pdf","source":{"id":"https://openalex.org/S4210207214","display_name":"International Journal For Multidisciplinary Research","issn_l":"2582-2160","issn":["2582-2160"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":"cc-by-sa","license_id":"https://openalex.org/licenses/cc-by-sa","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"International Journal For Multidisciplinary Research","raw_type":"journal-article"}],"best_oa_location":{"id":"doi:10.36948/ijfmr.2026.v08i04.85875","doi":"https://doi.org/10.36948/ijfmr.2026.v08i04.85875","is_oa":true,"landing_page_url":"https://doi.org/10.36948/ijfmr.2026.v08i04.85875","pdf_url":"https://www.ijfmr.com/papers/2026/4/85875.pdf","source":{"id":"https://openalex.org/S4210207214","display_name":"International Journal For Multidisciplinary Research","issn_l":"2582-2160","issn":["2582-2160"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":"cc-by-sa","license_id":"https://openalex.org/licenses/cc-by-sa","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"International Journal For Multidisciplinary Research","raw_type":"journal-article"},"sustainable_development_goals":[{"score":0.9853000044822693,"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7"},{"score":0.7207000255584717,"display_name":"Industry, innovation and infrastructure","id":"https://metadata.un.org/sdg/9"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":true,"grobid_xml":true},"content_urls":{"pdf":"https://content.openalex.org/works/W7203580992.pdf","grobid_xml":"https://content.openalex.org/works/W7203580992.grobid-xml"},"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W4224925059","https://openalex.org/W2778208289","https://openalex.org/W2054061295","https://openalex.org/W2387185099","https://openalex.org/W2377662081","https://openalex.org/W2047955885","https://openalex.org/W2386998989","https://openalex.org/W4381799843","https://openalex.org/W2375055544","https://openalex.org/W3080824362"],"abstract_inverted_index":{"Auxiliary":[0],"Power":[1,71],"Consumption":[2],"(APC)":[3],"is":[4],"one":[5],"of":[6,54,113,127,131,157,163,170],"the":[7,52,75,84,105,168],"critical":[8],"performance":[9,180],"indicators":[10],"in":[11,58,104,174,181],"thermal":[12,63,183],"power":[13,56,64,184],"plants,":[14],"directly":[15],"influencing":[16],"plant":[17,65],"efficiency":[18,177],"and":[19,42,110,137,178],"operational":[20,179],"cost.":[21],"In":[22],"large":[23,182],"supercritical":[24,62],"units,":[25],"auxiliary":[26,55,114],"equipment":[27,115],"such":[28,97],"as":[29,98],"boiler":[30],"feed":[31,134],"pumps,":[32,41],"induced":[33],"draft":[34,37],"fans,":[35,38],"forced":[36],"cooling":[39],"water":[40],"coal":[43],"mills":[44],"consume":[45],"significant":[46],"internal":[47],"power.":[48],"This":[49],"study":[50,166],"presents":[51],"optimization":[53],"consumption":[57],"an":[59,154],"800":[60],"MW":[61],"at":[66],"Sri":[67],"Damodaram":[68],"Sanjeevaiah":[69],"Thermal":[70],"Station":[72],"by":[73],"adopting":[74],"Six":[76,171],"Sigma":[77,172],"DMAIC":[78],"(Define\u2013Measure\u2013Analyze\u2013Improve\u2013Control)":[79],"methodology.":[80],"Operational":[81],"data":[82],"for":[83],"period":[85],"2023\u20132024":[86],"were":[87,116,141],"analyzed":[88],"to":[89,93,151],"identify":[90],"major":[91],"contributors":[92],"APC.":[94],"Key":[95],"issues":[96],"inefficient":[99],"pump":[100],"operation,":[101],"air":[102],"ingress":[103],"condenser,":[106],"suboptimal":[107],"combustion":[108,121],"conditions,":[109],"improper":[111],"operation":[112],"identified.":[117],"Improvement":[118],"actions":[119],"including":[120],"optimization,":[122],"mill":[123],"fine":[124],"tuning,":[125],"restoration":[126],"low-pressure":[128],"heater-3,":[129],"modification":[130],"high-pressure":[132],"heater":[133],"outlet":[135],"temperature,":[136],"condenser":[138],"vacuum":[139],"improvement":[140],"implemented.":[142],"As":[143],"a":[144],"result,":[145],"APC":[146],"was":[147],"reduced":[148],"from":[149],"6.9%":[150],"6.4%,":[152],"yielding":[153],"annual":[155],"saving":[156],"approximately":[158],"25":[159],"million":[160],"units":[161],"(MUs)":[162],"electricity.":[164],"The":[165],"demonstrates":[167],"effectiveness":[169],"techniques":[173],"improving":[175],"energy":[176],"plants.":[185]},"counts_by_year":[],"updated_date":"2026-10-28T10:33:24.094632","created_date":"2026-08-17T00:00:00"}
