{"id":"https://openalex.org/W7202364572","doi":"https://doi.org/10.1109/eic68788.2026.11642563","title":"Experience with Corona/Blackout Tests on Fully Assembled Stator Windings","display_name":"Experience with Corona/Blackout Tests on Fully Assembled Stator Windings","publication_year":2026,"publication_date":"2026-07-01","ids":{"openalex":"https://openalex.org/W7202364572","doi":"https://doi.org/10.1109/eic68788.2026.11642563"},"language":"en","primary_location":{"id":"doi:10.1109/eic68788.2026.11642563","doi":"https://doi.org/10.1109/eic68788.2026.11642563","is_oa":true,"landing_page_url":"https://doi.org/10.1109/eic68788.2026.11642563","pdf_url":null,"source":{"id":"https://openalex.org/S7407086244","display_name":"IEEE Electrical Insulation Conference (EIC)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2026 IEEE Electrical Insulation Conference (EIC)","raw_type":"proceedings-article"},"volume":null,"type":"conference-paper","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"hybrid","oa_url":"https://doi.org/10.1109/eic68788.2026.11642563","any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5040493309","display_name":"Mike Partyka","orcid":"https://orcid.org/0009-0004-8395-712X","observed_orcids":["https://orcid.org/0009-0004-8395-712X"]},"institutions":[{"id":"https://openalex.org/I33814908","display_name":"Manitoba Hydro","ror":"https://ror.org/03y90jx90","country_code":"CA","type":"company","lineage":["https://openalex.org/I33814908"]}],"countries":["CA"],"is_corresponding":false,"raw_author_name":"Mike Partyka","raw_affiliation_strings":["High Voltage Test Facility Manitoba Hydro"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"High Voltage Test Facility Manitoba Hydro","institution_ids":["https://openalex.org/I33814908"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5147099068","display_name":"Tyler Black","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I33814908","display_name":"Manitoba Hydro","ror":"https://ror.org/03y90jx90","country_code":"CA","type":"company","lineage":["https://openalex.org/I33814908"]}],"countries":["CA"],"is_corresponding":false,"raw_author_name":"Tyler Black","raw_affiliation_strings":["High Voltage Test Facility Manitoba Hydro"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"High Voltage Test Facility Manitoba Hydro","institution_ids":["https://openalex.org/I33814908"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I33814908"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.0,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"4"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10511","display_name":"High voltage insulation and dielectric phenomena","score":0.6636000275611877,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10511","display_name":"High voltage insulation and dielectric phenomena","score":0.6636000275611877,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11343","display_name":"Power Transformer Diagnostics and Insulation","score":0.2712000012397766,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10278","display_name":"Electric Motor Design and Analysis","score":0.02539999969303608,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/stator-winding","display_name":"stator winding","score":0.9779999852180481},{"id":"https://openalex.org/keywords/rotating-machinery","display_name":"rotating machinery","score":0.8519999980926514},{"id":"https://openalex.org/keywords/corona-discharge","display_name":"corona discharge","score":0.949999988079071},{"id":"https://openalex.org/keywords/insulation-degradation","display_name":"insulation degradation","score":0.5640000104904175},{"id":"https://openalex.org/keywords/partial-discharge","display_name":"partial discharge","score":0.7609999775886536},{"id":"https://openalex.org/keywords/acceptance-testing","display_name":"acceptance testing","score":0.859000027179718},{"id":"https://openalex.org/keywords/manitoba-hydro","display_name":"Manitoba Hydro","score":0.6899999976158142}],"concepts":[{"id":"https://openalex.org/C30403606","wikidata":"https://www.wikidata.org/wiki/Q2981904","display_name":"Electromagnetic coil","level":2,"score":0.45820000767707825},{"id":"https://openalex.org/C2776529397","wikidata":"https://www.wikidata.org/wiki/Q190312","display_name":"Stator","level":2,"score":0.44690001010894775},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.42480000853538513},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.423799991607666},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.36980000138282776},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.3237000107765198},{"id":"https://openalex.org/C199639397","wikidata":"https://www.wikidata.org/wiki/Q1788588","display_name":"Engineering drawing","level":1,"score":0.3003000020980835},{"id":"https://openalex.org/C66938386","wikidata":"https://www.wikidata.org/wiki/Q633538","display_name":"Structural engineering","level":1,"score":0.3001999855041504},{"id":"https://openalex.org/C24890656","wikidata":"https://www.wikidata.org/wiki/Q82811","display_name":"Acoustics","level":1,"score":0.2858000099658966},{"id":"https://openalex.org/C19474535","wikidata":"https://www.wikidata.org/wiki/Q131172","display_name":"Welding","level":2,"score":0.262800008058548}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/eic68788.2026.11642563","doi":"https://doi.org/10.1109/eic68788.2026.11642563","is_oa":true,"landing_page_url":"https://doi.org/10.1109/eic68788.2026.11642563","pdf_url":null,"source":{"id":"https://openalex.org/S7407086244","display_name":"IEEE Electrical Insulation Conference (EIC)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2026 IEEE Electrical Insulation Conference (EIC)","raw_type":"proceedings-article"}],"best_oa_location":{"id":"doi:10.1109/eic68788.2026.11642563","doi":"https://doi.org/10.1109/eic68788.2026.11642563","is_oa":true,"landing_page_url":"https://doi.org/10.1109/eic68788.2026.11642563","pdf_url":null,"source":{"id":"https://openalex.org/S7407086244","display_name":"IEEE Electrical Insulation Conference (EIC)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2026 IEEE Electrical Insulation Conference (EIC)","raw_type":"proceedings-article"},"sustainable_development_goals":[{"display_name":"Affordable and clean energy","score":0.8485000133514404,"id":"https://metadata.un.org/sdg/7"},{"display_name":"Industry, innovation and infrastructure","score":0.4943999946117401,"id":"https://metadata.un.org/sdg/9"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W7202350159","https://openalex.org/W2002545667","https://openalex.org/W7202367446","https://openalex.org/W7202345312","https://openalex.org/W7202405525","https://openalex.org/W2048285472","https://openalex.org/W7202360663","https://openalex.org/W7202356485","https://openalex.org/W7221201940","https://openalex.org/W2097700913"],"abstract_inverted_index":{"In":[0],"recent":[1],"years,":[2],"Manitoba":[3,57],"Hydro":[4],"has":[5,126],"begun":[6],"performing":[7],"corona/blackout":[8,39,53,104],"tests":[9,21,54,78,112],"on":[10,60,79,121],"the":[11,28,38,72,86,94,103,115],"stator":[12],"windings":[13],"of":[14,37,93],"rotating":[15],"machines":[16],"to":[17,91,128],"complement":[18],"existing":[19],"electrical":[20],"that":[22],"have":[23],"been":[24],"standard":[25],"practice":[26],"in":[27,85],"utility":[29,116],"for":[30,134,142],"decades.":[31],"This":[32],"paper":[33,47],"provides":[34],"an":[35],"overview":[36],"test,":[40],"including":[41],"its":[42],"benefits":[43],"and":[44,71,137],"limitations.":[45],"The":[46,99],"also":[48],"discusses":[49],"results":[50],"from":[51],"two":[52],"performed":[55,113],"by":[56,114],"Hydro.":[58],"Tests":[59],"a":[61,80,130,138],"new":[62,135],"winding":[63,82],"revealed":[64],"corona":[65],"discharge":[66],"between":[67],"air":[68],"gap":[69],"bars":[70],"winding's":[73],"intermediate":[74],"bracing":[75],"ring,":[76],"while":[77],"30-yearold":[81],"showed":[83],"discharges":[84],"slot":[87],"exit":[88],"region":[89],"due":[90],"degradation":[92],"bars'":[95],"stress":[96],"control":[97],"coatings.":[98],"issues":[100],"discovered":[101],"during":[102],"test":[105,125,133,141],"were":[106],"not":[107],"found":[108],"with":[109],"typical":[110],"insulation":[111],"(including":[117],"partial":[118],"discharge).":[119],"Based":[120],"our":[122],"experience,":[123],"this":[124],"proven":[127],"be":[129],"useful":[131],"acceptance":[132],"windings,":[136],"practical":[139],"diagnostic":[140],"service-aged":[143],"windings.":[144]},"counts_by_year":[],"updated_date":"2026-11-08T12:12:28.789561","created_date":"2026-08-14T00:00:00"}
