{"id":"https://openalex.org/W7166324936","doi":"https://doi.org/10.5281/zenodo.20969471","title":"Design and Performance Analysis of a Liquid Sub Cooler in a Refrigeration Circuit using a Shell-and-Tube Heat Exchanger","display_name":"Design and Performance Analysis of a Liquid Sub Cooler in a Refrigeration Circuit using a Shell-and-Tube Heat Exchanger","publication_year":2026,"publication_date":"2026-06-27","ids":{"openalex":"https://openalex.org/W7166324936","doi":"https://doi.org/10.5281/zenodo.20969471"},"language":"en","primary_location":{"id":"doi:10.5281/zenodo.20969471","doi":"https://doi.org/10.5281/zenodo.20969471","is_oa":true,"landing_page_url":"https://doi.org/10.5281/zenodo.20969471","pdf_url":null,"source":{"id":"https://openalex.org/S4306400562","display_name":"Zenodo (CERN European Organization for Nuclear Research)","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I67311998","host_organization_name":"European Organization for Nuclear Research","host_organization_lineage":["https://openalex.org/I67311998"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"Preprint"},"volume":null,"type":"preprint","indexed_in":["datacite"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"https://doi.org/10.5281/zenodo.20969471","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5139472623","display_name":"Hamza Hossani","orcid":"https://orcid.org/0009-0000-0606-7466","observed_orcids":["https://orcid.org/0009-0000-0606-7466"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Hossani, Hamza","raw_affiliation_strings":[],"raw_orcid":"https://orcid.org/0009-0000-0606-7466","affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5139494967","display_name":"Amine Soulane","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Soulane, Amine","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"last","author":{"id":"https://openalex.org/A5139476185","display_name":"Otmane Chaafane","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Chaafane, Otmane","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":null,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":null,"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11529","display_name":"Refrigeration and Air Conditioning Technologies","score":0.5249000191688538,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11529","display_name":"Refrigeration and Air Conditioning Technologies","score":0.5249000191688538,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10998","display_name":"Heat Transfer and Optimization","score":0.4652999937534332,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10850","display_name":"Heat Transfer and Boiling Studies","score":0.004000000189989805,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/shell-and-tube-heat-exchanger","display_name":"shell and tube heat exchanger","score":0.9610000252723694},{"id":"https://openalex.org/keywords/r717","display_name":"R717","score":0.8130000233650208},{"id":"https://openalex.org/keywords/thermal-design","display_name":"thermal design","score":0.7089999914169312},{"id":"https://openalex.org/keywords/kern-method","display_name":"Kern method","score":0.7910000085830688},{"id":"https://openalex.org/keywords/log-mean-temperature-difference","display_name":"log mean temperature difference","score":0.8320000171661377},{"id":"https://openalex.org/keywords/sieder-tate-correlation","display_name":"Sieder-Tate correlation","score":0.890999972820282},{"id":"https://openalex.org/keywords/thermal-transmittance","display_name":"thermal transmittance","score":0.7730000019073486},{"id":"https://openalex.org/keywords/fouling","display_name":"fouling","score":0.843999981880188},{"id":"https://openalex.org/keywords/coefficient-of-performance","display_name":"coefficient of performance","score":0.8889999985694885},{"id":"https://openalex.org/keywords/cooling-water","display_name":"cooling water","score":0.5720000267028809}],"concepts":[{"id":"https://openalex.org/C107706546","wikidata":"https://www.wikidata.org/wiki/Q189124","display_name":"Heat exchanger","level":2,"score":0.6473000049591064},{"id":"https://openalex.org/C69907114","wikidata":"https://www.wikidata.org/wiki/Q747713","display_name":"Refrigeration","level":2,"score":0.6241000294685364},{"id":"https://openalex.org/C91311341","wikidata":"https://www.wikidata.org/wiki/Q1764892","display_name":"Evaporator","level":3,"score":0.5514000058174133},{"id":"https://openalex.org/C97355855","wikidata":"https://www.wikidata.org/wiki/Q11473","display_name":"Thermodynamics","level":1,"score":0.5497000217437744},{"id":"https://openalex.org/C29700514","wikidata":"https://www.wikidata.org/wiki/Q634340","display_name":"Heat transfer coefficient","level":3,"score":0.47909998893737793},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.4722999930381775},{"id":"https://openalex.org/C205318045","wikidata":"https://www.wikidata.org/wiki/Q1930881","display_name":"Shell and tube heat exchanger","level":3,"score":0.45190000534057617},{"id":"https://openalex.org/C116915560","wikidata":"https://www.wikidata.org/wiki/Q83504","display_name":"Nuclear engineering","level":1,"score":0.4507000148296356},{"id":"https://openalex.org/C164915370","wikidata":"https://www.wikidata.org/wiki/Q5167494","display_name":"Cooling capacity","level":2,"score":0.4499000012874603},{"id":"https://openalex.org/C199499590","wikidata":"https://www.wikidata.org/wiki/Q266790","display_name":"Refrigerant","level":3,"score":0.44269999861717224},{"id":"https://openalex.org/C13119800","wikidata":"https://www.wikidata.org/wiki/Q902090","display_name":"Coefficient of performance","level":4,"score":0.4203999936580658},{"id":"https://openalex.org/C32375409","wikidata":"https://www.wikidata.org/wiki/Q261231","display_name":"Plate heat exchanger","level":3,"score":0.4178999960422516},{"id":"https://openalex.org/C50517652","wikidata":"https://www.wikidata.org/wiki/Q179635","display_name":"Heat transfer","level":2,"score":0.39980000257492065},{"id":"https://openalex.org/C2780934509","wikidata":"https://www.wikidata.org/wiki/Q571589","display_name":"Condenser (optics)","level":3,"score":0.3095000088214874},{"id":"https://openalex.org/C204826919","wikidata":"https://www.wikidata.org/wiki/Q905855","display_name":"NTU method","level":5,"score":0.2985999882221222},{"id":"https://openalex.org/C41004858","wikidata":"https://www.wikidata.org/wiki/Q1389702","display_name":"Economizer","level":3,"score":0.2971999943256378},{"id":"https://openalex.org/C7694927","wikidata":"https://www.wikidata.org/wiki/Q7667810","display_name":"Water cooling","level":2,"score":0.27799999713897705},{"id":"https://openalex.org/C141713623","wikidata":"https://www.wikidata.org/wiki/Q1452596","display_name":"Heat pump and refrigeration cycle","level":4,"score":0.27709999680519104},{"id":"https://openalex.org/C30487094","wikidata":"https://www.wikidata.org/wiki/Q332868","display_name":"Absorption refrigerator","level":3,"score":0.2768000066280365},{"id":"https://openalex.org/C57879066","wikidata":"https://www.wikidata.org/wiki/Q41217","display_name":"Mechanics","level":1,"score":0.27559998631477356},{"id":"https://openalex.org/C204530211","wikidata":"https://www.wikidata.org/wiki/Q752823","display_name":"Thermal","level":2,"score":0.27459999918937683},{"id":"https://openalex.org/C39420092","wikidata":"https://www.wikidata.org/wiki/Q17075298","display_name":"Plate fin heat exchanger","level":4,"score":0.27219998836517334},{"id":"https://openalex.org/C76563973","wikidata":"https://www.wikidata.org/wiki/Q189452","display_name":"Laminar flow","level":2,"score":0.2614000141620636},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.2547000050544739}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.5281/zenodo.20969471","doi":"https://doi.org/10.5281/zenodo.20969471","is_oa":true,"landing_page_url":"https://doi.org/10.5281/zenodo.20969471","pdf_url":null,"source":{"id":"https://openalex.org/S4306400562","display_name":"Zenodo (CERN European Organization for Nuclear Research)","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I67311998","host_organization_name":"European Organization for Nuclear Research","host_organization_lineage":["https://openalex.org/I67311998"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":null,"is_accepted":false,"is_published":null,"raw_source_name":null,"raw_type":"Preprint"},{"id":"doi:10.5281/zenodo.20969472","doi":"https://doi.org/10.5281/zenodo.20969472","is_oa":true,"landing_page_url":"https://doi.org/10.5281/zenodo.20969472","pdf_url":null,"source":{"id":"https://openalex.org/S4306400562","display_name":"Zenodo (CERN European Organization for Nuclear Research)","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I67311998","host_organization_name":"European Organization for Nuclear Research","host_organization_lineage":["https://openalex.org/I67311998"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":null,"is_accepted":false,"is_published":null,"raw_source_name":null,"raw_type":"Preprint"}],"best_oa_location":{"id":"doi:10.5281/zenodo.20969471","doi":"https://doi.org/10.5281/zenodo.20969471","is_oa":true,"landing_page_url":"https://doi.org/10.5281/zenodo.20969471","pdf_url":null,"source":{"id":"https://openalex.org/S4306400562","display_name":"Zenodo (CERN European Organization for Nuclear Research)","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I67311998","host_organization_name":"European Organization for Nuclear Research","host_organization_lineage":["https://openalex.org/I67311998"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"Preprint"},"sustainable_development_goals":[{"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7","score":0.571399986743927}],"sustainable_development_goals_aurora":[{"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7","score":0.4741004407405853}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":[],"abstract_inverted_index":{"This":[0],"paper":[1],"presents":[2],"the":[3,65,138,141,152,157],"complete":[4],"thermal":[5],"design":[6],"of":[7,55,71],"a":[8,14,51],"shell-and-tube":[9],"liquid":[10,30],"sub-cooler":[11,139],"integrated":[12],"into":[13],"single-stage":[15],"ammonia":[16],"(R717/NH\u2083)":[17],"refrigeration":[18],"cycle":[19,142],"operating":[20],"at":[21,42,47,156],"\u22121.88":[22],"\u00b0C":[23,34,37,44],"/":[24],"36":[25,33],"\u00b0C.":[26],"The":[27,75,110],"exchanger":[28],"sub-cools":[29],"NH\u2083":[31,59],"from":[32,64,144,160],"to":[35,146,162],"30":[36],"using":[38],"cooling":[39],"water":[40],"entering":[41],"24":[43],"and":[45,73,103,150],"leaving":[46],"29":[48],"\u00b0C,":[49],"with":[50,86,116],"total":[52],"heat":[53,113],"duty":[54],"15.30":[56],"kW.":[57],"All":[58],"thermodynamic":[60],"properties":[61],"are":[62],"taken":[63],"NIST":[66],"REFPROP":[67],"database":[68],"(National":[69],"Institute":[70],"Standards":[72],"Technology).":[74],"Kern":[76,105],"method":[77],"is":[78,118],"applied":[79],"step":[80],"by":[81],"step:":[82],"log-mean":[83],"temperature":[84],"difference":[85],"correction":[87],"factor,":[88],"preliminary":[89],"tube":[90],"count,":[91],"shell":[92],"diameter":[93],"sizing,":[94],"tube-side":[95],"Sieder\u2013Tate":[96],"correlation":[97,106],"for":[98,107],"thermally":[99],"developing":[100],"laminar":[101],"flow,":[102],"shell-side":[104],"turbulent":[108],"cross-flow.":[109],"resulting":[111],"overall":[112],"transfer":[114],"coefficient":[115],"fouling":[117],"U_design":[119],"=":[120],"275":[121],"W/m\u00b2\u00b7K,":[122,129],"validated":[123],"against":[124],"HTRI":[125],"Xist":[126],"v6.00":[127],"(274.8":[128],"deviation":[130],"<":[131],"0.1":[132],"%).":[133],"Thermoptim":[134],"simulation":[135],"confirms":[136],"that":[137],"raises":[140],"COP":[143],"6.05":[145],"6.21":[147],"(+2.6":[148],"%)":[149],"reduces":[151],"refrigerant":[153],"vapour":[154],"quality":[155],"evaporator":[158],"inlet":[159],"0.14":[161],"0.11.":[163]},"counts_by_year":[],"updated_date":"2026-10-07T09:51:55.459714","created_date":"2026-06-28T00:00:00"}
