{"id":"https://openalex.org/W7159809447","doi":"https://doi.org/10.3390/buildings16091777","title":"Comparative Analysis of Target Displacement Demands in Regular Reinforced Concrete Frames Under Different Seismic Design Codes","display_name":"Comparative Analysis of Target Displacement Demands in Regular Reinforced Concrete Frames Under Different Seismic Design Codes","publication_year":2026,"publication_date":"2026-04-29","ids":{"openalex":"https://openalex.org/W7159809447","doi":"https://doi.org/10.3390/buildings16091777"},"language":"en","primary_location":{"id":"doi:10.3390/buildings16091777","doi":"https://doi.org/10.3390/buildings16091777","is_oa":true,"landing_page_url":"https://doi.org/10.3390/buildings16091777","pdf_url":"https://www.mdpi.com/2075-5309/16/9/1777/pdf?version=1778309092","source":{"id":"https://openalex.org/S4210191137","display_name":"Buildings","issn_l":"2075-5309","issn":["2075-5309"],"is_oa":true,"is_in_doaj":true,"is_core":true,"listed_in":["anvur-class-a","anvur-scientific","cwts-core","doaj","norway-1","poland-70","russia-white-list-1"],"host_organization":"https://openalex.org/P4310310987","host_organization_name":"Multidisciplinary Digital Publishing Institute","host_organization_lineage":["https://openalex.org/P4310310987"],"host_organization_lineage_names":["Multidisciplinary Digital Publishing Institute"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Buildings","raw_type":"journal-article"},"volume":null,"type":"article","is_traditional":true,"indexed_in":["crossref","doaj"],"open_access":{"is_oa":true,"oa_status":"gold","oa_url":"https://www.mdpi.com/2075-5309/16/9/1777/pdf?version=1778309092","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5122347849","display_name":"Ercan I\u015f\u0131k","orcid":"https://orcid.org/0000-0001-8057-065X","observed_orcids":["https://orcid.org/0000-0001-8057-065X"]},"institutions":[{"id":"https://openalex.org/I41055640","display_name":"Bitlis Eren University","ror":"https://ror.org/00mm4ys28","country_code":"TR","type":"education","lineage":["https://openalex.org/I41055640"]}],"countries":["TR"],"is_corresponding":true,"raw_author_name":"Ercan I\u015f\u0131k","raw_affiliation_strings":["Faculty of Engineering and Architecture, Bitlis Eren University, Ahmet Eren Boulevard, 13100 Bitlis, T\u00fcrkiye"],"raw_orcid":"https://orcid.org/0000-0001-8057-065X","affiliations":[{"raw_affiliation_string":"Faculty of Engineering and Architecture, Bitlis Eren University, Ahmet Eren Boulevard, 13100 Bitlis, T\u00fcrkiye","institution_ids":["https://openalex.org/I41055640"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5112987808","display_name":"J Radi\u0107","orcid":"https://orcid.org/0009-0009-0787-8020","observed_orcids":["https://orcid.org/0009-0009-0787-8020"]},"institutions":[{"id":"https://openalex.org/I51314090","display_name":"University of Osijek","ror":"https://ror.org/05sw4wc49","country_code":"HR","type":"education","lineage":["https://openalex.org/I51314090"]}],"countries":["HR"],"is_corresponding":false,"raw_author_name":"Josip Radi\u0107","raw_affiliation_strings":["Faculty of Civil Engineering and Architecture Osijek, Josip Juraj Strossmayer University of Osijek, Vladimir Prelog St. 3, 31000 Osijek, Croatia"],"raw_orcid":"https://orcid.org/0009-0009-0787-8020","affiliations":[{"raw_affiliation_string":"Faculty of Civil Engineering and Architecture Osijek, Josip Juraj Strossmayer University of Osijek, Vladimir Prelog St. 3, 31000 Osijek, Croatia","institution_ids":["https://openalex.org/I51314090"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5014008813","display_name":"Antonija Ere\u0161","orcid":"https://orcid.org/0009-0009-8799-2375","observed_orcids":["https://orcid.org/0009-0009-8799-2375"]},"institutions":[{"id":"https://openalex.org/I51314090","display_name":"University of Osijek","ror":"https://ror.org/05sw4wc49","country_code":"HR","type":"education","lineage":["https://openalex.org/I51314090"]}],"countries":["HR"],"is_corresponding":false,"raw_author_name":"Antonija Ere\u0161","raw_affiliation_strings":["Faculty of Civil Engineering and Architecture Osijek, Josip Juraj Strossmayer University of Osijek, Vladimir Prelog St. 3, 31000 Osijek, Croatia"],"raw_orcid":"https://orcid.org/0009-0009-8799-2375","affiliations":[{"raw_affiliation_string":"Faculty of Civil Engineering and Architecture Osijek, Josip Juraj Strossmayer University of Osijek, Vladimir Prelog St. 3, 31000 Osijek, Croatia","institution_ids":["https://openalex.org/I51314090"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5056624539","display_name":"Marijana Hadzima-Nyarko","orcid":"https://orcid.org/0000-0002-9500-7285","observed_orcids":["https://orcid.org/0000-0002-9500-7285"]},"institutions":[{"id":"https://openalex.org/I51314090","display_name":"University of Osijek","ror":"https://ror.org/05sw4wc49","country_code":"HR","type":"education","lineage":["https://openalex.org/I51314090"]}],"countries":["HR"],"is_corresponding":true,"raw_author_name":"Marijana Hadzima-Nyarko","raw_affiliation_strings":["Faculty of Civil Engineering and Architecture Osijek, Josip Juraj Strossmayer University of Osijek, Vladimir Prelog St. 3, 31000 Osijek, Croatia"],"raw_orcid":"https://orcid.org/0000-0002-9500-7285","affiliations":[{"raw_affiliation_string":"Faculty of Civil Engineering and Architecture Osijek, Josip Juraj Strossmayer University of Osijek, Vladimir Prelog St. 3, 31000 Osijek, Croatia","institution_ids":["https://openalex.org/I51314090"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":2,"corresponding_author_ids":["https://openalex.org/A5056624539","https://openalex.org/A5122347849"],"corresponding_institution_ids":["https://openalex.org/I41055640","https://openalex.org/I51314090"],"apc_list":{"value":2600,"currency":"CHF","value_usd":3137},"apc_paid":{"value":2600,"currency":"CHF","value_usd":3137},"fwci":0.0,"has_fulltext":true,"cited_by_count":0,"citation_normalized_percentile":{"value":0.0,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"16","issue":"9","first_page":"1777","last_page":"1777"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10160","display_name":"Seismic Performance and Analysis","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2205","display_name":"Civil and Structural Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10160","display_name":"Seismic Performance and Analysis","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2205","display_name":"Civil and Structural Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11352","display_name":"Masonry and Concrete Structural Analysis","score":0.00019999999494757503,"subfield":{"id":"https://openalex.org/subfields/2205","display_name":"Civil and Structural Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10479","display_name":"Structural Behavior of Reinforced Concrete","score":9.999999747378752e-05,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/reinforced-concrete-frames","display_name":"reinforced concrete frames","score":0.9779999852180481},{"id":"https://openalex.org/keywords/seismic-design-codes","display_name":"seismic design codes","score":0.9599999785423279},{"id":"https://openalex.org/keywords/turkish-building-earthquake-code-2018","display_name":"Turkish Building Earthquake Code 2018","score":0.902999997138977},{"id":"https://openalex.org/keywords/asce-41","display_name":"ASCE 41","score":0.9929999709129333},{"id":"https://openalex.org/keywords/eurocode-8","display_name":"Eurocode 8","score":1.0},{"id":"https://openalex.org/keywords/pushover-analysis","display_name":"pushover analysis","score":0.7360000014305115},{"id":"https://openalex.org/keywords/soil-degradation","display_name":"soil degradation","score":0.8080000281333923},{"id":"https://openalex.org/keywords/soft-story","display_name":"soft story","score":0.6240000128746033},{"id":"https://openalex.org/keywords/structural-ductility","display_name":"structural ductility","score":0.753000020980835},{"id":"https://openalex.org/keywords/number-of-stories","display_name":"number of stories","score":0.7120000123977661},{"id":"https://openalex.org/keywords/seismic-performance-assessment","display_name":"seismic performance evaluation","score":0.4950000047683716},{"id":"https://openalex.org/keywords/code-conservatism","display_name":"code conservatism","score":0.39500001072883606}],"concepts":[{"id":"https://openalex.org/C66938386","wikidata":"https://www.wikidata.org/wiki/Q633538","display_name":"Structural engineering","level":1,"score":0.7896999716758728},{"id":"https://openalex.org/C107551265","wikidata":"https://www.wikidata.org/wiki/Q1458245","display_name":"Displacement (psychology)","level":2,"score":0.6452999711036682},{"id":"https://openalex.org/C182358397","wikidata":"https://www.wikidata.org/wiki/Q2656128","display_name":"Seismic analysis","level":2,"score":0.6437000036239624},{"id":"https://openalex.org/C2988805333","wikidata":"https://www.wikidata.org/wiki/Q184190","display_name":"Reinforced concrete","level":2,"score":0.5799000263214111},{"id":"https://openalex.org/C181781793","wikidata":"https://www.wikidata.org/wiki/Q1434513","display_name":"Eurocode","level":2,"score":0.5644999742507935},{"id":"https://openalex.org/C103711010","wikidata":"https://www.wikidata.org/wiki/Q909789","display_name":"Earthquake engineering","level":2,"score":0.5012999773025513},{"id":"https://openalex.org/C126042441","wikidata":"https://www.wikidata.org/wiki/Q1324888","display_name":"Frame (networking)","level":2,"score":0.49570000171661377},{"id":"https://openalex.org/C2776436953","wikidata":"https://www.wikidata.org/wiki/Q5163215","display_name":"Consistency (knowledge bases)","level":2,"score":0.484499990940094},{"id":"https://openalex.org/C2776512210","wikidata":"https://www.wikidata.org/wiki/Q5311608","display_name":"Ductility (Earth science)","level":3,"score":0.412200003862381},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3880999982357025},{"id":"https://openalex.org/C8128475","wikidata":"https://www.wikidata.org/wiki/Q6015423","display_name":"Incremental Dynamic Analysis","level":3,"score":0.38260000944137573},{"id":"https://openalex.org/C2776760102","wikidata":"https://www.wikidata.org/wiki/Q5139990","display_name":"Code (set theory)","level":3,"score":0.3763999938964844},{"id":"https://openalex.org/C158622935","wikidata":"https://www.wikidata.org/wiki/Q660848","display_name":"Nonlinear system","level":2,"score":0.37369999289512634},{"id":"https://openalex.org/C187320778","wikidata":"https://www.wikidata.org/wiki/Q1349130","display_name":"Geotechnical engineering","level":1,"score":0.36000001430511475},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.3587000072002411},{"id":"https://openalex.org/C56625316","wikidata":"https://www.wikidata.org/wiki/Q3492878","display_name":"Response spectrum","level":2,"score":0.3452000021934509},{"id":"https://openalex.org/C88282795","wikidata":"https://www.wikidata.org/wiki/Q2448108","display_name":"Structural system","level":2,"score":0.34459999203681946},{"id":"https://openalex.org/C2777212017","wikidata":"https://www.wikidata.org/wiki/Q2333573","display_name":"Building code","level":2,"score":0.32989999651908875},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.32670000195503235},{"id":"https://openalex.org/C182365436","wikidata":"https://www.wikidata.org/wiki/Q50701","display_name":"Variable (mathematics)","level":2,"score":0.3197000026702881},{"id":"https://openalex.org/C2781121862","wikidata":"https://www.wikidata.org/wiki/Q256","display_name":"Turkish","level":2,"score":0.31790000200271606},{"id":"https://openalex.org/C123060433","wikidata":"https://www.wikidata.org/wiki/Q2026731","display_name":"Seismic loading","level":2,"score":0.30169999599456787},{"id":"https://openalex.org/C2988284105","wikidata":"https://www.wikidata.org/wiki/Q11424730","display_name":"Ground motion","level":2,"score":0.3000999987125397},{"id":"https://openalex.org/C2779372316","wikidata":"https://www.wikidata.org/wiki/Q569057","display_name":"Stiffness","level":2,"score":0.2689000070095062},{"id":"https://openalex.org/C2993591475","wikidata":"https://www.wikidata.org/wiki/Q909789","display_name":"Earthquake resistance","level":2,"score":0.2632000148296356}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.3390/buildings16091777","doi":"https://doi.org/10.3390/buildings16091777","is_oa":true,"landing_page_url":"https://doi.org/10.3390/buildings16091777","pdf_url":"https://www.mdpi.com/2075-5309/16/9/1777/pdf?version=1778309092","source":{"id":"https://openalex.org/S4210191137","display_name":"Buildings","issn_l":"2075-5309","issn":["2075-5309"],"is_oa":true,"is_in_doaj":true,"is_core":true,"listed_in":["anvur-class-a","anvur-scientific","cwts-core","doaj","norway-1","poland-70","russia-white-list-1"],"host_organization":"https://openalex.org/P4310310987","host_organization_name":"Multidisciplinary Digital Publishing Institute","host_organization_lineage":["https://openalex.org/P4310310987"],"host_organization_lineage_names":["Multidisciplinary Digital Publishing Institute"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Buildings","raw_type":"journal-article"},{"id":"pmh:oai:doaj.org/article:0d078be4bfa44e98b1888955b40619b1","doi":null,"is_oa":true,"landing_page_url":"https://doaj.org/article/0d078be4bfa44e98b1888955b40619b1","pdf_url":null,"source":{"id":"https://openalex.org/S4306401280","display_name":"DOAJ (DOAJ: Directory of Open Access Journals)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by-sa","license_id":"https://openalex.org/licenses/cc-by-sa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Buildings, Vol 16, Iss 9, p 1777 (2026)","raw_type":"article"}],"best_oa_location":{"id":"doi:10.3390/buildings16091777","doi":"https://doi.org/10.3390/buildings16091777","is_oa":true,"landing_page_url":"https://doi.org/10.3390/buildings16091777","pdf_url":"https://www.mdpi.com/2075-5309/16/9/1777/pdf?version=1778309092","source":{"id":"https://openalex.org/S4210191137","display_name":"Buildings","issn_l":"2075-5309","issn":["2075-5309"],"is_oa":true,"is_in_doaj":true,"is_core":true,"listed_in":["anvur-class-a","anvur-scientific","cwts-core","doaj","norway-1","poland-70","russia-white-list-1"],"host_organization":"https://openalex.org/P4310310987","host_organization_name":"Multidisciplinary Digital Publishing Institute","host_organization_lineage":["https://openalex.org/P4310310987"],"host_organization_lineage_names":["Multidisciplinary Digital Publishing Institute"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Buildings","raw_type":"journal-article"},"sustainable_development_goals":[{"score":0.7250000238418579,"display_name":"Sustainable cities and communities","id":"https://metadata.un.org/sdg/11"}],"study_designs":[],"awards":[],"funders":[{"id":"https://openalex.org/F4320320300","display_name":"European Commission","ror":"https://ror.org/00k4n6c32"}],"has_content":{"pdf":true,"grobid_xml":true},"content_urls":{"pdf":"https://content.openalex.org/works/W7159809447.pdf","grobid_xml":"https://content.openalex.org/works/W7159809447.grobid-xml"},"referenced_works_count":57,"referenced_works":["https://openalex.org/W1539515023","https://openalex.org/W1808675277","https://openalex.org/W1969760883","https://openalex.org/W1989702602","https://openalex.org/W1990528390","https://openalex.org/W2001829511","https://openalex.org/W2009097298","https://openalex.org/W2015785775","https://openalex.org/W2021306693","https://openalex.org/W2023500811","https://openalex.org/W2030458089","https://openalex.org/W2039022455","https://openalex.org/W2057979305","https://openalex.org/W2130213987","https://openalex.org/W2148971984","https://openalex.org/W2155423289","https://openalex.org/W2164763866","https://openalex.org/W2337111860","https://openalex.org/W2739316361","https://openalex.org/W2950263273","https://openalex.org/W2999296986","https://openalex.org/W3016848006","https://openalex.org/W3092029552","https://openalex.org/W3176990312","https://openalex.org/W3201651874","https://openalex.org/W3205059882","https://openalex.org/W4206981305","https://openalex.org/W4285794535","https://openalex.org/W4292291559","https://openalex.org/W4292646786","https://openalex.org/W4303614332","https://openalex.org/W4306736800","https://openalex.org/W4312085914","https://openalex.org/W4320039184","https://openalex.org/W4385348880","https://openalex.org/W4385445203","https://openalex.org/W4386724810","https://openalex.org/W4387060365","https://openalex.org/W4388888647","https://openalex.org/W4393227174","https://openalex.org/W4400042788","https://openalex.org/W4402149250","https://openalex.org/W4402795666","https://openalex.org/W4403647880","https://openalex.org/W4404763955","https://openalex.org/W4406803071","https://openalex.org/W4407516777","https://openalex.org/W4409189322","https://openalex.org/W4409218903","https://openalex.org/W4409334696","https://openalex.org/W4412724101","https://openalex.org/W4414138158","https://openalex.org/W4415560326","https://openalex.org/W4416745396","https://openalex.org/W7127646362","https://openalex.org/W7128435041","https://openalex.org/W7135225261"],"related_works":["https://openalex.org/W4386588317","https://openalex.org/W3013523021","https://openalex.org/W2077218199","https://openalex.org/W3143980534","https://openalex.org/W7216076619","https://openalex.org/W3208886630","https://openalex.org/W4393173939","https://openalex.org/W2085231122","https://openalex.org/W2564222309","https://openalex.org/W2089161267"],"abstract_inverted_index":{"This":[0],"study":[1],"presents":[2],"a":[3,10,92,155],"comparative":[4,93],"investigation":[5],"of":[6,18,26,61,78,86,154],"target":[7,83,143],"displacement":[8,84,110,162,179],"demands,":[9,163],"fundamental":[11],"indicator":[12],"in":[13,46,181,187,202],"the":[14,24,27,44,82,87,149,152,168,200],"seismic":[15,114,129,207],"performance":[16,47],"assessment":[17],"reinforced":[19],"concrete":[20,63],"frame":[21,65],"systems,":[22],"within":[23],"framework":[25],"Turkish":[28],"Building":[29],"Earthquake":[30],"Code":[31],"(TBEC-2018),":[32],"American":[33],"standards":[34,39],"(ASCE":[35],"41),":[36],"and":[37,67,161,190],"European":[38],"(Eurocode":[40],"8).":[41],"To":[42],"analyse":[43],"consistency":[45],"levels":[48,131],"stipulated":[49],"by":[50],"different":[51,113],"structural":[52,159],"design":[53,208],"codes,":[54],"critical":[55,196],"variables,":[56],"including":[57],"soil":[58,139],"class,":[59],"number":[60],"stories,":[62],"grade,":[64],"span,":[66],"soft":[68],"story":[69,157],"at":[70,127],"ground":[71],"level,":[72],"were":[73,103,132],"parametrically":[74],"defined.":[75],"The":[76,121,193],"impact":[77],"these":[79],"variables":[80],"on":[81,100],"demands":[85,111,180],"structures":[88],"was":[89,172],"examined":[90],"through":[91],"lens.":[94],"Nonlinear":[95],"static":[96],"pushover":[97],"analyses":[98],"based":[99],"fiber-based":[101],"modelling":[102],"conducted":[104],"using":[105],"SeismoStruct":[106],"software":[107],"to":[108],"determine":[109],"under":[112],"code":[115],"formulations":[116],"across":[117,145,167],"six":[118],"distinct":[119],"variables.":[120],"displacements":[122,144],"obtained":[123],"for":[124,198],"each":[125],"variable":[126],"identical":[128],"ground-motion":[130],"evaluated":[133],"individually.":[134],"Analytical":[135],"results":[136],"reveal":[137],"that":[138,174],"degradation":[140],"significantly":[141],"increases":[142],"all":[146],"codes.":[147,169],"At":[148],"same":[150],"time,":[151],"presence":[153],"high":[156],"affects":[158],"ductility":[160],"with":[164],"varying":[165],"sensitivities":[166],"Notably,":[170],"it":[171],"observed":[173],"TBEC-2018":[175],"yields":[176],"more":[177],"conservative":[178],"certain":[182],"spectral":[183],"regions":[184],"than":[185],"those":[186],"ASCE":[188],"41":[189],"Eurocode":[191],"8.":[192],"findings":[194],"provide":[195],"data":[197],"understanding":[199],"disparities":[201],"safety":[203],"margins":[204],"among":[205],"international":[206],"standards.":[209]},"counts_by_year":[],"updated_date":"2026-11-07T11:25:07.637180","created_date":"2026-05-03T00:00:00"}
