{"id":"https://openalex.org/W7140106192","doi":"https://doi.org/10.1117/12.3100703","title":"Research on online comparison and measurement technology for the metering performance of networked power meters","display_name":"Research on online comparison and measurement technology for the metering performance of networked power meters","publication_year":2026,"publication_date":"2026-03-23","ids":{"openalex":"https://openalex.org/W7140106192","doi":"https://doi.org/10.1117/12.3100703"},"language":"en","primary_location":{"id":"doi:10.1117/12.3100703","doi":"https://doi.org/10.1117/12.3100703","is_oa":false,"landing_page_url":"https://doi.org/10.1117/12.3100703","pdf_url":null,"source":{"id":"https://openalex.org/S7407114964","display_name":"International Conference on Frontiers of Electrical Power and Energy Systems (EPES)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/P4310315543","host_organization_name":"SPIE","host_organization_lineage":["https://openalex.org/P4310315543"],"host_organization_lineage_names":["SPIE"],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Fifth International Conference on Frontiers of Electrical Power and Energy Systems (EPES 2025)","raw_type":"proceedings-article"},"volume":null,"type":"conference-paper","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5130356738","display_name":"Tao Zhang","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4210143001","display_name":"Tianjin Institute of Metrological Supervision Testing","ror":"https://ror.org/03pydxa09","country_code":"CN","type":"facility","lineage":["https://openalex.org/I4210143001"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Tao Zhang","raw_affiliation_strings":["Tianjin Institute of Metrological Supervision and Testing (China)"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Tianjin Institute of Metrological Supervision and Testing (China)","institution_ids":["https://openalex.org/I4210143001"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5130337158","display_name":"Chenggang Wang","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Chenggang Wang","raw_affiliation_strings":["Hospital of Integrated Chinese and Western Medicine (China)"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Hospital of Integrated Chinese and Western Medicine (China)","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5130370694","display_name":"Yimeng Zhang","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4210143001","display_name":"Tianjin Institute of Metrological Supervision Testing","ror":"https://ror.org/03pydxa09","country_code":"CN","type":"facility","lineage":["https://openalex.org/I4210143001"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Yimeng Zhang","raw_affiliation_strings":["Tianjin Institute of Metrological Supervision and Testing (China)"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Tianjin Institute of Metrological Supervision and Testing (China)","institution_ids":["https://openalex.org/I4210143001"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5130393188","display_name":"Na Dong","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4210143001","display_name":"Tianjin Institute of Metrological Supervision Testing","ror":"https://ror.org/03pydxa09","country_code":"CN","type":"facility","lineage":["https://openalex.org/I4210143001"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Na Dong","raw_affiliation_strings":["Tianjin Institute of Metrological Supervision and Testing (China)"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Tianjin Institute of Metrological Supervision and Testing (China)","institution_ids":["https://openalex.org/I4210143001"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5130326148","display_name":"Liying Cao","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4210143001","display_name":"Tianjin Institute of Metrological Supervision Testing","ror":"https://ror.org/03pydxa09","country_code":"CN","type":"facility","lineage":["https://openalex.org/I4210143001"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Liying Cao","raw_affiliation_strings":["Tianjin Institute of Metrological Supervision and Testing (China)"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Tianjin Institute of Metrological Supervision and Testing (China)","institution_ids":["https://openalex.org/I4210143001"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5122350969","display_name":"Qing Zhao","orcid":"https://orcid.org/0009-0007-1245-4869","observed_orcids":["https://orcid.org/0009-0007-1245-4869"]},"institutions":[{"id":"https://openalex.org/I4210143001","display_name":"Tianjin Institute of Metrological Supervision Testing","ror":"https://ror.org/03pydxa09","country_code":"CN","type":"facility","lineage":["https://openalex.org/I4210143001"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Qing Zhao","raw_affiliation_strings":["Tianjin Institute of Metrological Supervision and Testing (China)"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Tianjin Institute of Metrological Supervision and Testing (China)","institution_ids":["https://openalex.org/I4210143001"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.0,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"12","last_page":"12"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T12300","display_name":"Advanced Electrical Measurement Techniques","score":0.9872999787330627,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T12300","display_name":"Advanced Electrical Measurement Techniques","score":0.9872999787330627,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11890","display_name":"Scientific Measurement and Uncertainty Evaluation","score":0.002099999925121665,"subfield":{"id":"https://openalex.org/subfields/3105","display_name":"Instrumentation"},"field":{"id":"https://openalex.org/fields/31","display_name":"Physics and Astronomy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12451","display_name":"Smart Grid and Power Systems","score":0.0015999999595806003,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/meter-verification","display_name":"meter verification","score":0.5740000009536743},{"id":"https://openalex.org/keywords/low-voltage-distribution-networks","display_name":"low-voltage distribution networks","score":0.7940000295639038},{"id":"https://openalex.org/keywords/measurement-consistency","display_name":"measurement consistency","score":0.6269999742507935},{"id":"https://openalex.org/keywords/cumulative-error","display_name":"cumulative error","score":0.7070000171661377},{"id":"https://openalex.org/keywords/on-site-verification","display_name":"on-site verification","score":0.492000013589859},{"id":"https://openalex.org/keywords/energy-monitoring","display_name":"energy consumption monitoring","score":0.3199999928474426}],"concepts":[{"id":"https://openalex.org/C30905978","wikidata":"https://www.wikidata.org/wiki/Q815598","display_name":"Metering mode","level":2,"score":0.4957999885082245},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.47859999537467957},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.4494999945163727},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.37720000743865967},{"id":"https://openalex.org/C2780009758","wikidata":"https://www.wikidata.org/wiki/Q6804172","display_name":"Measure (data warehouse)","level":2,"score":0.32589998841285706},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.31690001487731934},{"id":"https://openalex.org/C67172668","wikidata":"https://www.wikidata.org/wiki/Q622756","display_name":"Electricity meter","level":3,"score":0.3111000061035156},{"id":"https://openalex.org/C26517878","wikidata":"https://www.wikidata.org/wiki/Q228039","display_name":"Key (lock)","level":2,"score":0.2955000102519989},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.28940001130104065},{"id":"https://openalex.org/C133462117","wikidata":"https://www.wikidata.org/wiki/Q4929239","display_name":"Data collection","level":2,"score":0.2840999960899353},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.26919999718666077},{"id":"https://openalex.org/C151011524","wikidata":"https://www.wikidata.org/wiki/Q11573","display_name":"Metre","level":2,"score":0.2639999985694885},{"id":"https://openalex.org/C115901376","wikidata":"https://www.wikidata.org/wiki/Q184199","display_name":"Automation","level":2,"score":0.25929999351501465},{"id":"https://openalex.org/C9652623","wikidata":"https://www.wikidata.org/wiki/Q190109","display_name":"Field (mathematics)","level":2,"score":0.25200000405311584}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1117/12.3100703","doi":"https://doi.org/10.1117/12.3100703","is_oa":false,"landing_page_url":"https://doi.org/10.1117/12.3100703","pdf_url":null,"source":{"id":"https://openalex.org/S7407114964","display_name":"International Conference on Frontiers of Electrical Power and Energy Systems (EPES)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/P4310315543","host_organization_name":"SPIE","host_organization_lineage":["https://openalex.org/P4310315543"],"host_organization_lineage_names":["SPIE"],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Fifth International Conference on Frontiers of Electrical Power and Energy Systems (EPES 2025)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.75,"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy"},{"score":0.6773999929428101,"id":"https://metadata.un.org/sdg/9","display_name":"Industry, innovation and infrastructure"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":3,"referenced_works":["https://openalex.org/W1970400714","https://openalex.org/W3118689231","https://openalex.org/W4389191991"],"related_works":["https://openalex.org/W3016811327","https://openalex.org/W6884919080","https://openalex.org/W2221989264","https://openalex.org/W2275794395","https://openalex.org/W2222972016","https://openalex.org/W3141187579","https://openalex.org/W2724165840","https://openalex.org/W2082239286","https://openalex.org/W1597615862","https://openalex.org/W6903945783"],"abstract_inverted_index":{"Networked":[0],"power":[1,42,64,71,105,158],"meters":[2,29,65],"are":[3,30,75],"widely":[4],"deployed":[5],"in":[6,77],"low-voltage":[7],"distribution":[8],"systems":[9],"for":[10,20,34,56,153],"energy":[11,16,25],"monitoring":[12],"and":[13,24,36,73,91,104,108,150],"management.":[14],"Accurate":[15],"metering":[17,59],"is":[18,66],"essential":[19],"reliable":[21],"data":[22],"collection":[23],"audits;":[26],"however,":[27],"embedded":[28],"difficult":[31],"to":[32,83,100,114],"remove":[33],"calibration,":[35],"traditional":[37],"verification":[38,155],"methods":[39],"often":[40],"require":[41],"interruption":[43],"or":[44],"provide":[45],"only":[46],"short-term":[47],"results.":[48],"To":[49],"address":[50],"this":[51],"limitation,":[52],"a":[53,147],"comparison-based":[54],"method":[55],"evaluating":[57],"the":[58,80,109,122,126,140],"performance":[60],"of":[61,125,156],"in-service":[62],"networked":[63,157],"proposed.":[67],"A":[68,94],"standard":[69],"high-accuracy":[70],"meter":[72,82,128],"transformers":[74],"connected":[76],"parallel":[78],"with":[79,132],"tested":[81,127],"perform":[84],"synchronous":[85],"long-term":[86],"measurements":[87],"under":[88],"identical":[89],"voltage":[90],"current":[92],"conditions.":[93],"one-week":[95],"comparison":[96],"test":[97],"was":[98,112],"conducted":[99],"cover":[101],"different":[102],"load":[103],"factor":[106],"conditions,":[107],"En":[110,134],"value":[111],"used":[113],"assess":[115],"measurement":[116],"consistency.":[117],"Experimental":[118],"results":[119],"show":[120],"that":[121],"cumulative":[123],"error":[124],"remained":[129],"within":[130],"\u00b10.2%,":[131],"all":[133],"values":[135],"less":[136],"than":[137],"1,":[138],"confirming":[139],"method\u2019s":[141],"reliability.":[142],"The":[143],"proposed":[144],"approach":[145],"provides":[146],"traceable,":[148],"long-term,":[149],"non-intrusive":[151],"solution":[152],"on-site":[154],"meters.":[159]},"counts_by_year":[],"updated_date":"2026-11-08T12:12:28.789561","created_date":"2026-03-24T00:00:00"}
