{"id":"https://openalex.org/W7137243992","doi":"https://doi.org/10.1109/icct67028.2025.11427668","title":"Wireless Fire Detection System with IOT Technology","display_name":"Wireless Fire Detection System with IOT Technology","publication_year":2025,"publication_date":"2025-10-07","ids":{"openalex":"https://openalex.org/W7137243992","doi":"https://doi.org/10.1109/icct67028.2025.11427668"},"language":"en","primary_location":{"id":"doi:10.1109/icct67028.2025.11427668","doi":"https://doi.org/10.1109/icct67028.2025.11427668","is_oa":false,"landing_page_url":"https://doi.org/10.1109/icct67028.2025.11427668","pdf_url":null,"source":{"id":"https://openalex.org/S4363608595","display_name":"International Conference on Information, Control, and Communication Technologies (ICCT)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2025 9th International Conference on Information, Control, and Communication Technologies (ICCT)","raw_type":"proceedings-article"},"volume":null,"type":"conference-paper","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5051201754","display_name":"Andrey N. Ushkov","orcid":"https://orcid.org/0009-0003-0721-4298","observed_orcids":["https://orcid.org/0009-0003-0721-4298"]},"institutions":[{"id":"https://openalex.org/I171241948","display_name":"Moscow Power Engineering Institute","ror":"https://ror.org/05sa6gg87","country_code":"RU","type":"education","lineage":["https://openalex.org/I171241948"]}],"countries":["RU"],"is_corresponding":false,"raw_author_name":"A. N. Ushkov","raw_affiliation_strings":["National Research University \u201cMoscow Power Engineering Institute\u201d,Moscow,Russia"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"National Research University \u201cMoscow Power Engineering Institute\u201d,Moscow,Russia","institution_ids":["https://openalex.org/I171241948"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5112162880","display_name":"A. V. Trofimov","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I171241948","display_name":"Moscow Power Engineering Institute","ror":"https://ror.org/05sa6gg87","country_code":"RU","type":"education","lineage":["https://openalex.org/I171241948"]}],"countries":["RU"],"is_corresponding":false,"raw_author_name":"A.Y. Trofimov","raw_affiliation_strings":["National Research University \u201cMoscow Power Engineering Institute\u201d,Moscow,Russia"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"National Research University \u201cMoscow Power Engineering Institute\u201d,Moscow,Russia","institution_ids":["https://openalex.org/I171241948"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5024855838","display_name":"P. S. Ostapenkov","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I171241948","display_name":"Moscow Power Engineering Institute","ror":"https://ror.org/05sa6gg87","country_code":"RU","type":"education","lineage":["https://openalex.org/I171241948"]}],"countries":["RU"],"is_corresponding":false,"raw_author_name":"P. S. Ostapenkov","raw_affiliation_strings":["National Research University \u201cMoscow Power Engineering Institute\u201d,Moscow,Russia"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"National Research University \u201cMoscow Power Engineering Institute\u201d,Moscow,Russia","institution_ids":["https://openalex.org/I171241948"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5129486634","display_name":"P.V. Pustovalov","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I171241948","display_name":"Moscow Power Engineering Institute","ror":"https://ror.org/05sa6gg87","country_code":"RU","type":"education","lineage":["https://openalex.org/I171241948"]}],"countries":["RU"],"is_corresponding":false,"raw_author_name":"P.V. Pustovalov","raw_affiliation_strings":["National Research University \u201cMoscow Power Engineering Institute\u201d,Moscow,Russia"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"National Research University \u201cMoscow Power Engineering Institute\u201d,Moscow,Russia","institution_ids":["https://openalex.org/I171241948"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5091800002","display_name":"S.Y. Ponomareva","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I171241948","display_name":"Moscow Power Engineering Institute","ror":"https://ror.org/05sa6gg87","country_code":"RU","type":"education","lineage":["https://openalex.org/I171241948"]}],"countries":["RU"],"is_corresponding":false,"raw_author_name":"S.Y. Ponomareva","raw_affiliation_strings":["National Research University \u201cMoscow Power Engineering Institute\u201d,Moscow,Russia"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"National Research University \u201cMoscow Power Engineering Institute\u201d,Moscow,Russia","institution_ids":["https://openalex.org/I171241948"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5082209087","display_name":"\u0412. \u0421. \u0424\u043b\u0430\u043d\u0434\u0435\u043d","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I171241948","display_name":"Moscow Power Engineering Institute","ror":"https://ror.org/05sa6gg87","country_code":"RU","type":"education","lineage":["https://openalex.org/I171241948"]}],"countries":["RU"],"is_corresponding":false,"raw_author_name":"V.S. Flanden","raw_affiliation_strings":["National Research University \u201cMoscow Power Engineering Institute\u201d,Moscow,Russia"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"National Research University \u201cMoscow Power Engineering Institute\u201d,Moscow,Russia","institution_ids":["https://openalex.org/I171241948"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5049393197","display_name":"N. O. Strelkov","orcid":"https://orcid.org/0000-0003-0013-1919","observed_orcids":["https://orcid.org/0000-0003-0013-1919"]},"institutions":[{"id":"https://openalex.org/I171241948","display_name":"Moscow Power Engineering Institute","ror":"https://ror.org/05sa6gg87","country_code":"RU","type":"education","lineage":["https://openalex.org/I171241948"]}],"countries":["RU"],"is_corresponding":false,"raw_author_name":"N. O. Strelkov","raw_affiliation_strings":["National Research University \u201cMoscow Power Engineering Institute\u201d,Moscow,Russia"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"National Research University \u201cMoscow Power Engineering Institute\u201d,Moscow,Russia","institution_ids":["https://openalex.org/I171241948"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I171241948"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.0,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"6"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T12597","display_name":"Fire Detection and Safety Systems","score":0.9868000149726868,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T12597","display_name":"Fire Detection and Safety Systems","score":0.9868000149726868,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13535","display_name":"Wireless Sensor Networks and IoT","score":0.005400000140070915,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13420","display_name":"Arduino and IoT Applications","score":0.0032999999821186066,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/internet-of-things","display_name":"Internet of Things","score":0.746999979019165},{"id":"https://openalex.org/keywords/cloud-monitoring","display_name":"cloud-based monitoring","score":0.8019999861717224},{"id":"https://openalex.org/keywords/can-bus","display_name":"CAN bus","score":0.5960000157356262},{"id":"https://openalex.org/keywords/bluetooth","display_name":"Bluetooth","score":0.953000009059906},{"id":"https://openalex.org/keywords/cortex-m3-microcontroller","display_name":"Cortex-M3 microcontroller","score":0.9039999842643738},{"id":"https://openalex.org/keywords/industrial-fire-safety","display_name":"industrial fire safety","score":0.656000018119812},{"id":"https://openalex.org/keywords/false-alarm-detection","display_name":"false alarm detection","score":0.6079999804496765},{"id":"https://openalex.org/keywords/fault-monitoring","display_name":"fault monitoring","score":0.3869999945163727},{"id":"https://openalex.org/keywords/data-collection-devices","display_name":"data collection devices","score":0.6449999809265137}],"concepts":[{"id":"https://openalex.org/C2780836893","wikidata":"https://www.wikidata.org/wiki/Q19922674","display_name":"Fire detection","level":2,"score":0.7002999782562256},{"id":"https://openalex.org/C546215728","wikidata":"https://www.wikidata.org/wiki/Q39531","display_name":"Bluetooth","level":3,"score":0.6256999969482422},{"id":"https://openalex.org/C555944384","wikidata":"https://www.wikidata.org/wiki/Q249","display_name":"Wireless","level":2,"score":0.5493000149726868},{"id":"https://openalex.org/C152745839","wikidata":"https://www.wikidata.org/wiki/Q5438153","display_name":"Fault detection and isolation","level":3,"score":0.5169000029563904},{"id":"https://openalex.org/C173018170","wikidata":"https://www.wikidata.org/wiki/Q165678","display_name":"Microcontroller","level":2,"score":0.5047000050544739},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.48980000615119934},{"id":"https://openalex.org/C79974875","wikidata":"https://www.wikidata.org/wiki/Q483639","display_name":"Cloud computing","level":2,"score":0.487199991941452},{"id":"https://openalex.org/C2779119184","wikidata":"https://www.wikidata.org/wiki/Q294350","display_name":"ALARM","level":2,"score":0.48350000381469727},{"id":"https://openalex.org/C2780728072","wikidata":"https://www.wikidata.org/wiki/Q5297","display_name":"Microprocessor","level":2,"score":0.46650001406669617},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.45190000534057617},{"id":"https://openalex.org/C194305327","wikidata":"https://www.wikidata.org/wiki/Q1022253","display_name":"Manual fire alarm activation","level":3,"score":0.4154999852180481},{"id":"https://openalex.org/C149635348","wikidata":"https://www.wikidata.org/wiki/Q193040","display_name":"Embedded system","level":1,"score":0.40959998965263367},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.398499995470047},{"id":"https://openalex.org/C2779697362","wikidata":"https://www.wikidata.org/wiki/Q390516","display_name":"Control room","level":2,"score":0.37599998712539673},{"id":"https://openalex.org/C17500928","wikidata":"https://www.wikidata.org/wiki/Q959968","display_name":"Control system","level":2,"score":0.3571000099182129},{"id":"https://openalex.org/C26517878","wikidata":"https://www.wikidata.org/wiki/Q228039","display_name":"Key (lock)","level":2,"score":0.35530000925064087},{"id":"https://openalex.org/C133462117","wikidata":"https://www.wikidata.org/wiki/Q4929239","display_name":"Data collection","level":2,"score":0.34369999170303345},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.33399999141693115},{"id":"https://openalex.org/C86338984","wikidata":"https://www.wikidata.org/wiki/Q79708","display_name":"General Packet Radio Service","level":3,"score":0.32179999351501465},{"id":"https://openalex.org/C94915269","wikidata":"https://www.wikidata.org/wiki/Q1834857","display_name":"Detector","level":2,"score":0.3077999949455261},{"id":"https://openalex.org/C38652104","wikidata":"https://www.wikidata.org/wiki/Q3510521","display_name":"Computer security","level":1,"score":0.30640000104904175},{"id":"https://openalex.org/C24590314","wikidata":"https://www.wikidata.org/wiki/Q336038","display_name":"Wireless sensor network","level":2,"score":0.3028999865055084},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.30230000615119934},{"id":"https://openalex.org/C138827492","wikidata":"https://www.wikidata.org/wiki/Q6661985","display_name":"Data processing","level":2,"score":0.2978000044822693},{"id":"https://openalex.org/C2776836416","wikidata":"https://www.wikidata.org/wiki/Q1364844","display_name":"False alarm","level":2,"score":0.2971000075340271},{"id":"https://openalex.org/C81988521","wikidata":"https://www.wikidata.org/wiki/Q676838","display_name":"Control unit","level":2,"score":0.28299999237060547},{"id":"https://openalex.org/C132835097","wikidata":"https://www.wikidata.org/wiki/Q7663745","display_name":"System safety","level":2,"score":0.28130000829696655},{"id":"https://openalex.org/C2777488183","wikidata":"https://www.wikidata.org/wiki/Q6900510","display_name":"Safety monitoring","level":2,"score":0.2793999910354614},{"id":"https://openalex.org/C40071531","wikidata":"https://www.wikidata.org/wiki/Q2513962","display_name":"Industrial control system","level":3,"score":0.27889999747276306},{"id":"https://openalex.org/C2775846686","wikidata":"https://www.wikidata.org/wiki/Q643012","display_name":"Condition monitoring","level":2,"score":0.2711000144481659},{"id":"https://openalex.org/C527821871","wikidata":"https://www.wikidata.org/wiki/Q228502","display_name":"Access control","level":2,"score":0.257999986410141},{"id":"https://openalex.org/C2776666747","wikidata":"https://www.wikidata.org/wiki/Q1135322","display_name":"Modbus","level":3,"score":0.257099986076355},{"id":"https://openalex.org/C557945733","wikidata":"https://www.wikidata.org/wiki/Q389772","display_name":"Data transmission","level":2,"score":0.25679999589920044}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/icct67028.2025.11427668","doi":"https://doi.org/10.1109/icct67028.2025.11427668","is_oa":false,"landing_page_url":"https://doi.org/10.1109/icct67028.2025.11427668","pdf_url":null,"source":{"id":"https://openalex.org/S4363608595","display_name":"International Conference on Information, Control, and Communication Technologies (ICCT)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2025 9th International Conference on Information, Control, and Communication Technologies (ICCT)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.5378999710083008,"display_name":"Industry, innovation and infrastructure","id":"https://metadata.un.org/sdg/9"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":21,"referenced_works":["https://openalex.org/W2011639706","https://openalex.org/W2034491914","https://openalex.org/W2315784213","https://openalex.org/W2800497142","https://openalex.org/W2907704522","https://openalex.org/W2944753573","https://openalex.org/W3205953949","https://openalex.org/W4281670243","https://openalex.org/W4367597951","https://openalex.org/W4388093986","https://openalex.org/W4388107311","https://openalex.org/W4390708837","https://openalex.org/W4390823431","https://openalex.org/W4399769091","https://openalex.org/W4399769396","https://openalex.org/W4401330632","https://openalex.org/W4410227678","https://openalex.org/W4410583547","https://openalex.org/W4410860380","https://openalex.org/W4411306424","https://openalex.org/W7133239790"],"related_works":["https://openalex.org/W4410227678","https://openalex.org/W4399769091","https://openalex.org/W4403773000","https://openalex.org/W2366895209","https://openalex.org/W3117039324","https://openalex.org/W7220178621","https://openalex.org/W3164152399","https://openalex.org/W4388660232","https://openalex.org/W3134700832","https://openalex.org/W2758131703"],"abstract_inverted_index":{"The":[0,91,135,180],"development":[1],"of":[2,10,18,27,32,59,65,78,104,119,137,174,203,226,232],"microprocessor":[3],"technology":[4],"has":[5,123],"led":[6],"to":[7,38,40,101,163,196,219],"the":[8,19,24,57,66,73,79,105,117,138,142,149,164,169,175,189,198,221,233],"integration":[9],"microcontrollers":[11],"into":[12],"human":[13,41],"safety":[14,107],"systems.":[15],"An":[16],"analysis":[17,133],"algorithms":[20],"showed":[21],"that":[22,35],"despite":[23],"increased":[25],"level":[26],"automation,":[28],"there":[29],"are":[30],"cases":[31],"incorrect":[33,206],"operation":[34,58],"can":[36],"lead":[37],"danger":[39],"life.":[42],"Wireless":[43],"monitoring":[44,116,186],"using":[45,94],"cloud":[46,185],"technologies":[47,96],"is":[48,141,146,155,161,209],"a":[49,76,98,128,210,227],"technical":[50],"solution":[51,182],"for":[52,81,115,183,188,201],"collecting":[53],"additional":[54],"information":[55,160,199],"about":[56],"security":[60,214],"systems":[61,215],"and":[62,83,132,159,205,216],"fault":[63],"control":[64,102,166],"data":[67,85,130],"collection":[68,131],"system.":[69,237],"In":[70],"this":[71],"article,":[72],"authors":[74],"proposed":[75,181],"version":[77,100],"device":[80],"analyzing":[82],"processing":[84],"from":[86,153],"fire":[87,106,120,190,234],"sensors":[88,154],"obtained":[89],"wirelessly.":[90],"article":[92],"suggests":[93],"wireless":[95],"in":[97,110,224],"hybrid":[99],"elements":[103],"system":[108,114,192],"used":[109],"industrial":[111,178],"facilities.":[112],"A":[113],"condition":[118],"smoke":[121],"detectors":[122],"been":[124],"developed,":[125],"which":[126,145,208],"includes":[127],"developed":[129],"device.":[134],"center":[136],"intelligent":[139],"module":[140],"K1986VE91T":[143],"microcontroller,":[144],"based":[147],"on":[148],"cortex-M3":[150],"core.":[151],"Data":[152],"processed":[156],"via":[157,168],"Bluetooth":[158],"transmitted":[162],"central":[165],"unit":[167],"CAN":[170],"bus,":[171],"as":[172],"one":[173],"most":[176],"reliable":[177],"interfaces.":[179],"integrating":[184],"tools":[187],"detector":[191],"makes":[193],"it":[194],"possible":[195],"increase":[197],"content":[200],"reasons":[202],"failure":[204],"operation,":[207],"step":[211],"towards":[212],"optimizing":[213],"allows":[217],"you":[218],"make":[220],"right":[222],"decision":[223],"case":[225],"false":[228],"alarm":[229],"or":[230],"malfunction":[231],"extinguishing":[235],"detection":[236]},"counts_by_year":[],"updated_date":"2026-11-10T11:39:43.021295","created_date":"2026-03-17T00:00:00"}
