{"id":"https://openalex.org/W7128908916","doi":"https://doi.org/10.47460/athenea.v7i23.126","title":"Comparison of the effectiveness between the Wavelet Transform and the Wigner-Ville Transform for the diagnosis of low insulation in the starting transient of induction motors","display_name":"Comparison of the effectiveness between the Wavelet Transform and the Wigner-Ville Transform for the diagnosis of low insulation in the starting transient of induction motors","publication_year":2026,"publication_date":"2026-02-11","ids":{"openalex":"https://openalex.org/W7128908916","doi":"https://doi.org/10.47460/athenea.v7i23.126"},"language":"en","primary_location":{"id":"doi:10.47460/athenea.v7i23.126","doi":"https://doi.org/10.47460/athenea.v7i23.126","is_oa":true,"landing_page_url":"https://doi.org/10.47460/athenea.v7i23.126","pdf_url":"https://athenea.autanabooks.com/index.php/revista/article/download/126/341","source":{"id":"https://openalex.org/S4210217842","display_name":"Athenea","issn_l":"2737-6419","issn":["2737-6419"],"is_oa":true,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Athenea","raw_type":"journal-article"},"volume":null,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"diamond","oa_url":"https://athenea.autanabooks.com/index.php/revista/article/download/126/341","any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5029571466","display_name":"Alfredo Alejandro Marot Guevara","orcid":"https://orcid.org/0000-0002-8829-4124","observed_orcids":["https://orcid.org/0000-0002-8829-4124"]},"institutions":[{"id":"https://openalex.org/I4210134112","display_name":"Universidad Nacional Experimental Polit\u00e9cnica Antonio Jos\u00e9 de Sucre","ror":"https://ror.org/03mnvhz29","country_code":"VE","type":"education","lineage":["https://openalex.org/I4210134112"]}],"countries":["VE"],"is_corresponding":false,"raw_author_name":"Alfredo Alejandro Marot Guevara","raw_affiliation_strings":["Universidad Nacional Experimental Polit\u00e9cnica \"Antonio Jos\u00e9 de Sucre\""],"raw_orcid":"https://orcid.org/0000-0002-8829-4124","affiliations":[{"raw_affiliation_string":"Universidad Nacional Experimental Polit\u00e9cnica \"Antonio Jos\u00e9 de Sucre\"","institution_ids":["https://openalex.org/I4210134112"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5085619506","display_name":"Sergio Vel\u00e1squez","orcid":"https://orcid.org/0000-0002-3516-4430","observed_orcids":["https://orcid.org/0000-0002-3516-4430"]},"institutions":[{"id":"https://openalex.org/I4210134112","display_name":"Universidad Nacional Experimental Polit\u00e9cnica Antonio Jos\u00e9 de Sucre","ror":"https://ror.org/03mnvhz29","country_code":"VE","type":"education","lineage":["https://openalex.org/I4210134112"]}],"countries":["VE"],"is_corresponding":false,"raw_author_name":"Sergio Rafael Velasquez Guzman","raw_affiliation_strings":["Universidad Nacional Experimental Polit\u00e9cnica \"Antonio Jos\u00e9 de Sucre\""],"raw_orcid":"https://orcid.org/0000-0002-3516-4430","affiliations":[{"raw_affiliation_string":"Universidad Nacional Experimental Polit\u00e9cnica \"Antonio Jos\u00e9 de Sucre\"","institution_ids":["https://openalex.org/I4210134112"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I4210134112"],"apc_list":null,"apc_paid":null,"fwci":1.6164,"has_fulltext":true,"cited_by_count":1,"citation_normalized_percentile":{"value":0.77710441,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":91,"max":95},"biblio":{"volume":"7","issue":"23","first_page":"28","last_page":"28"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10220","display_name":"Machine Fault Diagnosis Techniques","score":0.9990000128746033,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10220","display_name":"Machine Fault Diagnosis Techniques","score":0.9990000128746033,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12737","display_name":"Electrical Fault Detection and Protection","score":0.00019999999494757503,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11343","display_name":"Power Transformer Diagnostics and Insulation","score":9.999999747378752e-05,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/discrete-wavelet-transform","display_name":"discrete wavelet transform","score":0.8309999704360962},{"id":"https://openalex.org/keywords/wigner-ville-transform","display_name":"Wigner-Ville transform","score":0.9860000014305115},{"id":"https://openalex.org/keywords/fault-detection","display_name":"fault detection","score":0.621999979019165},{"id":"https://openalex.org/keywords/predictive-maintenance","display_name":"predictive maintenance","score":0.8220000267028809}],"concepts":[{"id":"https://openalex.org/C180591934","wikidata":"https://www.wikidata.org/wiki/Q1253369","display_name":"Downtime","level":2,"score":0.7444999814033508},{"id":"https://openalex.org/C80962145","wikidata":"https://www.wikidata.org/wiki/Q207450","display_name":"Induction motor","level":3,"score":0.6861000061035156},{"id":"https://openalex.org/C196216189","wikidata":"https://www.wikidata.org/wiki/Q2867","display_name":"Wavelet transform","level":3,"score":0.6115999817848206},{"id":"https://openalex.org/C21200559","wikidata":"https://www.wikidata.org/wiki/Q7451068","display_name":"Sensitivity (control systems)","level":2,"score":0.585099995136261},{"id":"https://openalex.org/C2780799671","wikidata":"https://www.wikidata.org/wiki/Q17087362","display_name":"Transient (computer programming)","level":2,"score":0.5733000040054321},{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.5655999779701233},{"id":"https://openalex.org/C46286280","wikidata":"https://www.wikidata.org/wiki/Q2414958","display_name":"Discrete wavelet transform","level":4,"score":0.47679999470710754},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.45239999890327454},{"id":"https://openalex.org/C152745839","wikidata":"https://www.wikidata.org/wiki/Q5438153","display_name":"Fault detection and isolation","level":3,"score":0.45210000872612},{"id":"https://openalex.org/C2779855323","wikidata":"https://www.wikidata.org/wiki/Q1172774","display_name":"Daubechies wavelet","level":5,"score":0.4514000117778778},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4377000033855438},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.41920000314712524},{"id":"https://openalex.org/C47432892","wikidata":"https://www.wikidata.org/wiki/Q831390","display_name":"Wavelet","level":2,"score":0.41119998693466187},{"id":"https://openalex.org/C155777637","wikidata":"https://www.wikidata.org/wiki/Q2736187","display_name":"Wavelet packet decomposition","level":4,"score":0.38420000672340393},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3377000093460083},{"id":"https://openalex.org/C142433447","wikidata":"https://www.wikidata.org/wiki/Q7806653","display_name":"Time\u2013frequency analysis","level":3,"score":0.33480000495910645},{"id":"https://openalex.org/C2775846686","wikidata":"https://www.wikidata.org/wiki/Q643012","display_name":"Condition monitoring","level":2,"score":0.3165999948978424},{"id":"https://openalex.org/C153180895","wikidata":"https://www.wikidata.org/wiki/Q7148389","display_name":"Pattern recognition (psychology)","level":2,"score":0.3156999945640564},{"id":"https://openalex.org/C124681953","wikidata":"https://www.wikidata.org/wiki/Q339062","display_name":"Decomposition","level":2,"score":0.31290000677108765},{"id":"https://openalex.org/C95722684","wikidata":"https://www.wikidata.org/wiki/Q2622756","display_name":"Continuous wavelet transform","level":5,"score":0.28850001096725464},{"id":"https://openalex.org/C165838908","wikidata":"https://www.wikidata.org/wiki/Q736777","display_name":"Calibration","level":2,"score":0.2872999906539917},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.2854999899864197},{"id":"https://openalex.org/C73339587","wikidata":"https://www.wikidata.org/wiki/Q1375942","display_name":"Stationary wavelet transform","level":5,"score":0.2847000062465668},{"id":"https://openalex.org/C33923547","wikidata":"https://www.wikidata.org/wiki/Q395","display_name":"Mathematics","level":0,"score":0.28029999136924744},{"id":"https://openalex.org/C104267543","wikidata":"https://www.wikidata.org/wiki/Q208163","display_name":"Signal processing","level":3,"score":0.27790001034736633}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.47460/athenea.v7i23.126","doi":"https://doi.org/10.47460/athenea.v7i23.126","is_oa":true,"landing_page_url":"https://doi.org/10.47460/athenea.v7i23.126","pdf_url":"https://athenea.autanabooks.com/index.php/revista/article/download/126/341","source":{"id":"https://openalex.org/S4210217842","display_name":"Athenea","issn_l":"2737-6419","issn":["2737-6419"],"is_oa":true,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Athenea","raw_type":"journal-article"}],"best_oa_location":{"id":"doi:10.47460/athenea.v7i23.126","doi":"https://doi.org/10.47460/athenea.v7i23.126","is_oa":true,"landing_page_url":"https://doi.org/10.47460/athenea.v7i23.126","pdf_url":"https://athenea.autanabooks.com/index.php/revista/article/download/126/341","source":{"id":"https://openalex.org/S4210217842","display_name":"Athenea","issn_l":"2737-6419","issn":["2737-6419"],"is_oa":true,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Athenea","raw_type":"journal-article"},"sustainable_development_goals":[{"display_name":"Industry, innovation and infrastructure","id":"https://metadata.un.org/sdg/9","score":0.651199996471405}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":true,"grobid_xml":true},"content_urls":{"pdf":"https://content.openalex.org/works/W7128908916.pdf","grobid_xml":"https://content.openalex.org/works/W7128908916.grobid-xml"},"referenced_works_count":10,"referenced_works":["https://openalex.org/W2025651303","https://openalex.org/W2026743245","https://openalex.org/W2062024414","https://openalex.org/W2088302359","https://openalex.org/W2117171612","https://openalex.org/W3011538722","https://openalex.org/W3035330751","https://openalex.org/W4210621722","https://openalex.org/W4255272544","https://openalex.org/W4380372961"],"related_works":["https://openalex.org/W1975656019","https://openalex.org/W4400358009","https://openalex.org/W4408766105","https://openalex.org/W2035127909","https://openalex.org/W2544939331","https://openalex.org/W2980069703","https://openalex.org/W3145810742","https://openalex.org/W2486167230","https://openalex.org/W2184423869","https://openalex.org/W1532468329"],"abstract_inverted_index":{"This":[0,69],"study":[1],"demonstrates":[2],"the":[3,6,11,33],"superiority":[4],"of":[5,27],"Discrete":[7],"Wavelet":[8],"Transform":[9,13],"over":[10],"Wigner-Ville":[12],"in":[14,18],"detecting":[15],"insulation":[16],"faults":[17],"induction":[19],"motors":[20],"during":[21],"startup":[22],"transients.":[23],"The":[24],"comprehensive":[25],"analysis":[26],"360":[28],"simulated":[29],"signals":[30],"revealed":[31],"that":[32,85],"wavelet":[34],"technique":[35,70],"with":[36,57],"Daubechies":[37],"10":[38],"achieves":[39],"significantly":[40],"higher":[41],"classification":[42],"accuracy":[43],"(74.44%":[44],"vs.":[45],"67.78%),":[46],"substantially":[47,86],"outperforming":[48],"its":[49,67],"counterpart.":[50],"Certain":[51],"decomposition":[52],"levels":[53],"showed":[54],"maximum":[55],"sensitivity":[56],"variations":[58],"up":[59],"to":[60],"+354%,":[61],"while":[62],"diagnostic":[63],"reliability":[64],"indicators":[65],"confirm":[66],"robustness.":[68],"positions":[71],"itself":[72],"as":[73],"an":[74],"optimal":[75],"solution":[76],"for":[77],"predictive":[78],"monitoring":[79],"systems,":[80],"enabling":[81],"early":[82],"fault":[83],"detection":[84],"reduces":[87],"downtime":[88],"and":[89],"industrial":[90],"maintenance":[91],"costs.":[92]},"counts_by_year":[{"year":2026,"cited_by_count":1}],"updated_date":"2026-11-10T11:39:43.021295","created_date":"2026-02-15T00:00:00"}