{"id":"https://openalex.org/W7128706232","doi":"https://doi.org/10.30574/wjarr.2024.24.3.3803","title":"Sustainable Energy Optimization Through Cloud-Native Building Automation and Predictive Analytics Integration","display_name":"Sustainable Energy Optimization Through Cloud-Native Building Automation and Predictive Analytics Integration","alternate_titles":[],"publication_year":2024,"publication_date":"2024-12-31","ids":{"openalex":"https://openalex.org/W7128706232","doi":"https://doi.org/10.30574/wjarr.2024.24.3.3803"},"language":"en","primary_location":{"id":"doi:10.30574/wjarr.2024.24.3.3803","doi":"https://doi.org/10.30574/wjarr.2024.24.3.3803","is_oa":true,"landing_page_url":"https://doi.org/10.30574/wjarr.2024.24.3.3803","pdf_url":"https://wjarr.com/sites/default/files/WJARR-2024-3803.pdf","source":{"id":"https://openalex.org/S4210223820","display_name":"World Journal of Advanced Research and Reviews","issn_l":"2581-9615","issn":["2581-9615"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/P4383735917","host_organization_name":"GSC Online Press","host_organization_lineage":["https://openalex.org/P4383735917"],"host_organization_lineage_names":["GSC Online Press"],"type":"journal"},"license":"cc-by-nc-sa","license_id":"https://openalex.org/licenses/cc-by-nc-sa","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"World Journal of Advanced Research and Reviews","raw_type":"journal-article"},"parent_works":[],"lineage":["https://openalex.org/W7128706232"],"child_works_count":0,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"hybrid","oa_url":"https://wjarr.com/sites/default/files/WJARR-2024-3803.pdf","any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5117861616","display_name":"Sampath Kumar Konda","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4210099550","display_name":"Schneider Electric (United States)","ror":"https://ror.org/00x39dd97","country_code":"US","type":"company","lineage":["https://openalex.org/I1305429183","https://openalex.org/I4210099550"]}],"countries":["US"],"is_corresponding":true,"contributor_roles":[],"raw_author_name":"Sampath Kumar Konda","raw_affiliation_strings":["Regional System Architect , Schneider Electric , USA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Regional System Architect , Schneider Electric , USA","institution_ids":["https://openalex.org/I4210099550"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":["https://openalex.org/A5117861616"],"corresponding_institution_ids":["https://openalex.org/I4210099550"],"apc_list":null,"apc_paid":null,"fwci":0.5566,"has_fulltext":true,"cited_by_count":4,"citation_normalized_percentile":{"value":0.61091783,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":86,"max":96},"biblio":{"volume":"24","issue":"3","first_page":"3619","last_page":"3628"},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.9932000041007996,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.9932000041007996,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.0017999999690800905,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13263","display_name":"Building energy efficiency and sustainability","score":0.0010000000474974513,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/predictive-analytics","display_name":"predictive analytics","score":0.6230000257492065},{"id":"https://openalex.org/keywords/predictive-fault-detection","display_name":"predictive fault detection","score":0.7590000033378601},{"id":"https://openalex.org/keywords/demand-response","display_name":"demand response","score":0.906000018119812},{"id":"https://openalex.org/keywords/load-curtailment","display_name":"load curtailment","score":0.984000027179718},{"id":"https://openalex.org/keywords/hvac-control","display_name":"HVAC control","score":0.42500001192092896},{"id":"https://openalex.org/keywords/timescaledb","display_name":"TimescaleDB","score":0.7009999752044678},{"id":"https://openalex.org/keywords/maintenance-prioritization","display_name":"maintenance prioritization","score":0.5640000104904175},{"id":"https://openalex.org/keywords/energy-consumption-reduction","display_name":"energy consumption reduction","score":0.5389999747276306}],"concepts":[{"id":"https://openalex.org/C83931994","wikidata":"https://www.wikidata.org/wiki/Q1149653","display_name":"Building automation","level":2,"score":0.6990000009536743},{"id":"https://openalex.org/C122346748","wikidata":"https://www.wikidata.org/wiki/Q1798773","display_name":"HVAC","level":3,"score":0.5577999949455261},{"id":"https://openalex.org/C48044578","wikidata":"https://www.wikidata.org/wiki/Q727490","display_name":"Scalability","level":2,"score":0.5267000198364258},{"id":"https://openalex.org/C115901376","wikidata":"https://www.wikidata.org/wiki/Q184199","display_name":"Automation","level":2,"score":0.5184999704360962},{"id":"https://openalex.org/C2779662365","wikidata":"https://www.wikidata.org/wiki/Q5416694","display_name":"Event (particle physics)","level":2,"score":0.5170000195503235},{"id":"https://openalex.org/C2780165032","wikidata":"https://www.wikidata.org/wiki/Q16869822","display_name":"Energy consumption","level":2,"score":0.47369998693466187},{"id":"https://openalex.org/C2742236","wikidata":"https://www.wikidata.org/wiki/Q924713","display_name":"Efficient energy use","level":2,"score":0.4505999982357025},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.43779999017715454},{"id":"https://openalex.org/C70452415","wikidata":"https://www.wikidata.org/wiki/Q3182448","display_name":"Predictive maintenance","level":2,"score":0.429500013589859},{"id":"https://openalex.org/C9652623","wikidata":"https://www.wikidata.org/wiki/Q190109","display_name":"Field (mathematics)","level":2,"score":0.4156999886035919},{"id":"https://openalex.org/C106527866","wikidata":"https://www.wikidata.org/wiki/Q1489497","display_name":"Building management system","level":3,"score":0.4138000011444092},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.4115999937057495},{"id":"https://openalex.org/C160331591","wikidata":"https://www.wikidata.org/wiki/Q7075743","display_name":"Occupancy","level":2,"score":0.38420000672340393},{"id":"https://openalex.org/C79158427","wikidata":"https://www.wikidata.org/wiki/Q485396","display_name":"Analytics","level":2,"score":0.3743000030517578},{"id":"https://openalex.org/C66862320","wikidata":"https://www.wikidata.org/wiki/Q842017","display_name":"Building information modeling","level":3,"score":0.36629998683929443},{"id":"https://openalex.org/C507571656","wikidata":"https://www.wikidata.org/wiki/Q848436","display_name":"Home automation","level":2,"score":0.3596000075340271},{"id":"https://openalex.org/C2779438525","wikidata":"https://www.wikidata.org/wiki/Q5255048","display_name":"Demand response","level":3,"score":0.3422999978065491},{"id":"https://openalex.org/C2778505942","wikidata":"https://www.wikidata.org/wiki/Q18344624","display_name":"Microservices","level":3,"score":0.3280999958515167},{"id":"https://openalex.org/C75684735","wikidata":"https://www.wikidata.org/wiki/Q858810","display_name":"Big data","level":2,"score":0.3160000145435333},{"id":"https://openalex.org/C152745839","wikidata":"https://www.wikidata.org/wiki/Q5438153","display_name":"Fault detection and isolation","level":3,"score":0.3149999976158142},{"id":"https://openalex.org/C2779530757","wikidata":"https://www.wikidata.org/wiki/Q1207505","display_name":"Quality (philosophy)","level":2,"score":0.305400013923645},{"id":"https://openalex.org/C177212765","wikidata":"https://www.wikidata.org/wiki/Q627335","display_name":"Workflow","level":2,"score":0.29600000381469727},{"id":"https://openalex.org/C201995342","wikidata":"https://www.wikidata.org/wiki/Q682496","display_name":"Systems engineering","level":1,"score":0.29350000619888306},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.28679999709129333},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.2808000147342682},{"id":"https://openalex.org/C186370098","wikidata":"https://www.wikidata.org/wiki/Q442787","display_name":"Energy (signal processing)","level":2,"score":0.2775999903678894},{"id":"https://openalex.org/C2779585090","wikidata":"https://www.wikidata.org/wiki/Q3457762","display_name":"Resilience (materials science)","level":2,"score":0.2669000029563904},{"id":"https://openalex.org/C148803439","wikidata":"https://www.wikidata.org/wiki/Q4986688","display_name":"Built environment","level":2,"score":0.26660001277923584},{"id":"https://openalex.org/C170154142","wikidata":"https://www.wikidata.org/wiki/Q150737","display_name":"Architectural engineering","level":1,"score":0.25999999046325684},{"id":"https://openalex.org/C110593043","wikidata":"https://www.wikidata.org/wiki/Q7300787","display_name":"Real-time data","level":2,"score":0.25940001010894775},{"id":"https://openalex.org/C83209312","wikidata":"https://www.wikidata.org/wiki/Q1053367","display_name":"Predictive analytics","level":2,"score":0.2565999925136566},{"id":"https://openalex.org/C66204764","wikidata":"https://www.wikidata.org/wiki/Q219416","display_name":"Sustainability","level":2,"score":0.2515000104904175},{"id":"https://openalex.org/C123657996","wikidata":"https://www.wikidata.org/wiki/Q12271","display_name":"Architecture","level":2,"score":0.25099998712539673},{"id":"https://openalex.org/C520343842","wikidata":"https://www.wikidata.org/wiki/Q3353193","display_name":"Energy engineering","level":3,"score":0.25049999356269836}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.30574/wjarr.2024.24.3.3803","doi":"https://doi.org/10.30574/wjarr.2024.24.3.3803","is_oa":true,"landing_page_url":"https://doi.org/10.30574/wjarr.2024.24.3.3803","pdf_url":"https://wjarr.com/sites/default/files/WJARR-2024-3803.pdf","source":{"id":"https://openalex.org/S4210223820","display_name":"World Journal of Advanced Research and Reviews","issn_l":"2581-9615","issn":["2581-9615"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/P4383735917","host_organization_name":"GSC Online Press","host_organization_lineage":["https://openalex.org/P4383735917"],"host_organization_lineage_names":["GSC Online Press"],"type":"journal"},"license":"cc-by-nc-sa","license_id":"https://openalex.org/licenses/cc-by-nc-sa","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"World Journal of Advanced Research and Reviews","raw_type":"journal-article"}],"best_oa_location":{"id":"doi:10.30574/wjarr.2024.24.3.3803","doi":"https://doi.org/10.30574/wjarr.2024.24.3.3803","is_oa":true,"landing_page_url":"https://doi.org/10.30574/wjarr.2024.24.3.3803","pdf_url":"https://wjarr.com/sites/default/files/WJARR-2024-3803.pdf","source":{"id":"https://openalex.org/S4210223820","display_name":"World Journal of Advanced Research and Reviews","issn_l":"2581-9615","issn":["2581-9615"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/P4383735917","host_organization_name":"GSC Online Press","host_organization_lineage":["https://openalex.org/P4383735917"],"host_organization_lineage_names":["GSC Online Press"],"type":"journal"},"license":"cc-by-nc-sa","license_id":"https://openalex.org/licenses/cc-by-nc-sa","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"World Journal of Advanced Research and Reviews","raw_type":"journal-article"},"sustainable_development_goals":[{"score":0.7207000255584717,"display_name":"Industry, innovation and infrastructure","id":"https://metadata.un.org/sdg/9"},{"score":0.7128999829292297,"display_name":"Sustainable cities and communities","id":"https://metadata.un.org/sdg/11"},{"score":0.5351999998092651,"display_name":"Climate action","id":"https://metadata.un.org/sdg/13"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":true,"grobid_xml":true},"content_urls":{"pdf":"https://content.openalex.org/works/W7128706232.pdf","grobid_xml":"https://content.openalex.org/works/W7128706232.grobid-xml"},"referenced_works_count":14,"referenced_works":["https://openalex.org/W1973944436","https://openalex.org/W2017657413","https://openalex.org/W2031268492","https://openalex.org/W2086536376","https://openalex.org/W2108152153","https://openalex.org/W2109318516","https://openalex.org/W2122411471","https://openalex.org/W2220250323","https://openalex.org/W2249163419","https://openalex.org/W2436872002","https://openalex.org/W2727307896","https://openalex.org/W2754029504","https://openalex.org/W2788308593","https://openalex.org/W2903266954"],"related_works":["https://openalex.org/W4410395394","https://openalex.org/W7140211097","https://openalex.org/W2793777765","https://openalex.org/W2546981594","https://openalex.org/W7203643325","https://openalex.org/W4223578717","https://openalex.org/W2797828945","https://openalex.org/W2078063397","https://openalex.org/W4415764231","https://openalex.org/W7117449212"],"abstract_inverted_index":{"Managing":[0],"energy":[1,85,128,160],"in":[2,87,126,162],"large-scale":[3],"sports":[4],"and":[5,19,57,78,106,118,142,149,156],"entertainment":[6],"venues":[7],"is":[8],"uniquely":[9],"challenging":[10],"due":[11],"to":[12,38,40,45,83],"rapid":[13],"occupancy":[14],"fluctuations,":[15],"diverse":[16],"event":[17,116],"types,":[18],"complex,":[20],"multi-system":[21],"mechanical":[22],"infrastructures":[23],"spanning":[24],"vast":[25],"spatial":[26],"footprints.":[27],"Conventional":[28],"building":[29,65],"automation":[30,66],"strategies,":[31],"optimized":[32],"for":[33,187],"steady-state":[34],"commercial":[35],"buildings,":[36],"fail":[37],"adapt":[39],"stadiums":[41],"transitioning":[42],"from":[43],"empty":[44],"tens":[46],"of":[47,49,166],"thousands":[48],"occupants":[50],"within":[51],"hours":[52],"across":[53,174],"baseball":[54],"games,":[55],"concerts,":[56],"special":[58],"events.":[59],"This":[60],"paper":[61],"presents":[62],"a":[63,123,167,184],"cloud-native":[64],"architecture":[67],"integrating":[68],"distributed":[69],"field":[70],"control,":[71],"high-velocity":[72],"time-series":[73],"analytics,":[74],"predictive":[75],"fault":[76,134],"detection,":[77],"real-time":[79],"demand":[80],"response":[81],"orchestration":[82],"optimize":[84],"use":[86],"multi-purpose":[88],"venues.":[89],"PostgreSQL":[90],"with":[91,115,147],"TimescaleDB":[92],"extensions":[93],"supports":[94],"continuous":[95],"trend":[96],"data":[97],"ingestion,":[98],"while":[99,178],"cloud-hosted":[100],"Building":[101],"Advisor":[102],"services":[103],"automate":[104],"diagnostics":[105],"maintenance":[107],"prioritization.":[108],"Predictive":[109],"occupancy-driven":[110],"ventilation,":[111],"dynamic":[112],"pre-conditioning":[113],"aligned":[114],"schedules,":[117],"automated":[119],"load":[120],"curtailment":[121],"achieve":[122],"37%":[124],"reduction":[125],"annual":[127],"consumption":[129],"versus":[130],"traditional":[131],"schedules.":[132],"Sub-second":[133],"detection":[135],"enables":[136],"proactive":[137],"interventions,":[138],"preserving":[139],"equipment":[140],"integrity":[141],"occupant":[143],"comfort.":[144],"Closed-loop":[145],"integration":[146],"ticketing":[148],"fan":[150],"engagement":[151],"systems":[152],"dynamically":[153],"adjusts":[154],"HVAC":[155],"lighting":[157],"zones,":[158],"eliminating":[159],"waste":[161],"unoccupied":[163],"areas.":[164],"Simulation":[165],"30,000-seat":[168],"retractable":[169],"dome":[170],"stadium":[171],"confirms":[172],"scalability":[173],"927,000":[175],"square":[176],"feet":[177],"maintaining":[179],"air":[180],"quality":[181],"standards,":[182],"establishing":[183],"replicable":[185],"framework":[186],"sustainable,":[188],"high-performance":[189],"smart":[190],"venue":[191],"operations.":[192]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W7128706232","counts_by_year":[{"year":2026,"cited_by_count":2},{"year":2025,"cited_by_count":1},{"year":2024,"cited_by_count":1}],"updated_date":"2026-11-16T12:05:36.265796","created_date":"2026-02-13T00:00:00"}
