{"id":"https://openalex.org/W7128328569","doi":null,"title":"MATHEMATICAL MODELING AND SIMULATION OF ENERGY CONSUMPTION IN SCHOOL/OFFICE BUILDINGS USING ENERGYPLUS AND OPENSTUDIO","display_name":"MATHEMATICAL MODELING AND SIMULATION OF ENERGY CONSUMPTION IN SCHOOL/OFFICE BUILDINGS USING ENERGYPLUS AND OPENSTUDIO","publication_year":2025,"publication_date":"2025-05-01","ids":{"openalex":"https://openalex.org/W7128328569"},"language":"en","primary_location":{"id":"pmh:oai:doaj.org/article:62b81392026743d19156b3f3be7963d7","doi":null,"is_oa":true,"landing_page_url":"https://doaj.org/article/62b81392026743d19156b3f3be7963d7","pdf_url":null,"source":{"id":"https://openalex.org/S4306401280","display_name":"DOAJ (DOAJ: Directory of Open Access Journals)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by-sa","license_id":"https://openalex.org/licenses/cc-by-sa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Fiabilitate \u015fi Durabilitate, Vol 18, Iss 1, Pp 268-272 (2025)","raw_type":"article"},"volume":null,"type":"article","indexed_in":["doaj"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"https://doaj.org/article/62b81392026743d19156b3f3be7963d7","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5125364491","display_name":"Maria-Isabela CA\u0218OT\u0102 (Ghicajanu)","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4210149165","display_name":"Universitatea Din Petrosani","ror":"https://ror.org/055k3dh55","country_code":"RO","type":"education","lineage":["https://openalex.org/I4210149165"]}],"countries":["RO"],"is_corresponding":true,"raw_author_name":"Maria-Isabela CA\u0218OT\u0102 (Ghicajanu)","raw_affiliation_strings":["University of Petro\u0219ani, ROMANIA"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"University of Petro\u0219ani, ROMANIA","institution_ids":["https://openalex.org/I4210149165"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":["https://openalex.org/A5125364491"],"corresponding_institution_ids":["https://openalex.org/I4210149165"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.46885982,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13263","display_name":"Building energy efficiency and sustainability","score":0.0003000000142492354,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/building-energy-consumption","display_name":"building energy consumption","score":0.7649999856948853},{"id":"https://openalex.org/keywords/school-buildings","display_name":"school buildings","score":0.9900000095367432},{"id":"https://openalex.org/keywords/office-buildings","display_name":"office buildings","score":0.9390000104904175},{"id":"https://openalex.org/keywords/energyplus","display_name":"EnergyPlus","score":0.9330000281333923},{"id":"https://openalex.org/keywords/openstudio","display_name":"OpenStudio","score":0.9739999771118164},{"id":"https://openalex.org/keywords/hvac-systems","display_name":"HVAC systems","score":0.8519999980926514},{"id":"https://openalex.org/keywords/occupancy-schedules","display_name":"occupancy schedules","score":0.984000027179718},{"id":"https://openalex.org/keywords/energy-saving-strategies","display_name":"energy-saving strategies","score":0.8119999766349792},{"id":"https://openalex.org/keywords/insulation-improvement","display_name":"insulation improvement","score":0.7350000143051147},{"id":"https://openalex.org/keywords/lighting-retrofit","display_name":"lighting retrofit","score":0.9150000214576721},{"id":"https://openalex.org/keywords/ventilation-optimization","display_name":"ventilation system optimization","score":0.9980000257492065},{"id":"https://openalex.org/keywords/3d-building-modeling","display_name":"3D building modeling","score":0.75},{"id":"https://openalex.org/keywords/carbon-emission-reduction","display_name":"carbon emission reduction","score":0.765999972820282},{"id":"https://openalex.org/keywords/sustainable-building-design","display_name":"sustainable building design","score":0.7099999785423279}],"concepts":[{"id":"https://openalex.org/C122346748","wikidata":"https://www.wikidata.org/wiki/Q1798773","display_name":"HVAC","level":3,"score":0.7556999921798706},{"id":"https://openalex.org/C2780165032","wikidata":"https://www.wikidata.org/wiki/Q16869822","display_name":"Energy consumption","level":2,"score":0.6765999794006348},{"id":"https://openalex.org/C2780331096","wikidata":"https://www.wikidata.org/wiki/Q24965464","display_name":"Energy modeling","level":3,"score":0.5819000005722046},{"id":"https://openalex.org/C160331591","wikidata":"https://www.wikidata.org/wiki/Q7075743","display_name":"Occupancy","level":2,"score":0.5149999856948853},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.44290000200271606},{"id":"https://openalex.org/C186370098","wikidata":"https://www.wikidata.org/wiki/Q442787","display_name":"Energy (signal processing)","level":2,"score":0.4422999918460846},{"id":"https://openalex.org/C2742236","wikidata":"https://www.wikidata.org/wiki/Q924713","display_name":"Efficient energy use","level":2,"score":0.44190001487731934},{"id":"https://openalex.org/C170154142","wikidata":"https://www.wikidata.org/wiki/Q150737","display_name":"Architectural engineering","level":1,"score":0.39660000801086426},{"id":"https://openalex.org/C167343916","wikidata":"https://www.wikidata.org/wiki/Q6888384","display_name":"Modeling and simulation","level":2,"score":0.3853999972343445},{"id":"https://openalex.org/C2776409380","wikidata":"https://www.wikidata.org/wiki/Q18205688","display_name":"Building energy simulation","level":4,"score":0.3750999867916107},{"id":"https://openalex.org/C108215451","wikidata":"https://www.wikidata.org/wiki/Q7263963","display_name":"Simulation modeling","level":2,"score":0.36890000104904175},{"id":"https://openalex.org/C2777735758","wikidata":"https://www.wikidata.org/wiki/Q817765","display_name":"Path (computing)","level":2,"score":0.364300012588501},{"id":"https://openalex.org/C30772137","wikidata":"https://www.wikidata.org/wiki/Q5164762","display_name":"Consumption (sociology)","level":2,"score":0.36090001463890076},{"id":"https://openalex.org/C200457457","wikidata":"https://www.wikidata.org/wiki/Q584049","display_name":"Ventilation (architecture)","level":2,"score":0.35089999437332153},{"id":"https://openalex.org/C2982928256","wikidata":"https://www.wikidata.org/wiki/Q6865456","display_name":"Energy performance","level":3,"score":0.350600004196167},{"id":"https://openalex.org/C2983177510","wikidata":"https://www.wikidata.org/wiki/Q1853339","display_name":"Energy demand","level":2,"score":0.3458999991416931},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3411000072956085},{"id":"https://openalex.org/C44154836","wikidata":"https://www.wikidata.org/wiki/Q45045","display_name":"Simulation","level":1,"score":0.3407999873161316},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.3303999900817871},{"id":"https://openalex.org/C552854447","wikidata":"https://www.wikidata.org/wiki/Q131201","display_name":"Sustainable development","level":2,"score":0.3163999915122986},{"id":"https://openalex.org/C76969082","wikidata":"https://www.wikidata.org/wiki/Q486902","display_name":"Mathematical model","level":2,"score":0.29899999499320984},{"id":"https://openalex.org/C520301825","wikidata":"https://www.wikidata.org/wiki/Q380170","display_name":"Energy conservation","level":2,"score":0.29280000925064087},{"id":"https://openalex.org/C13736549","wikidata":"https://www.wikidata.org/wiki/Q4489420","display_name":"Industrial engineering","level":1,"score":0.2921999990940094},{"id":"https://openalex.org/C103742991","wikidata":"https://www.wikidata.org/wiki/Q173725","display_name":"Air conditioning","level":2,"score":0.2791000008583069},{"id":"https://openalex.org/C67186912","wikidata":"https://www.wikidata.org/wiki/Q367664","display_name":"Data modeling","level":2,"score":0.27709999680519104},{"id":"https://openalex.org/C520343842","wikidata":"https://www.wikidata.org/wiki/Q3353193","display_name":"Energy engineering","level":3,"score":0.2728999853134155},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.2662000060081482},{"id":"https://openalex.org/C106527866","wikidata":"https://www.wikidata.org/wiki/Q1489497","display_name":"Building management system","level":3,"score":0.2615000009536743},{"id":"https://openalex.org/C201995342","wikidata":"https://www.wikidata.org/wiki/Q682496","display_name":"Systems engineering","level":1,"score":0.26010000705718994},{"id":"https://openalex.org/C42475967","wikidata":"https://www.wikidata.org/wiki/Q194292","display_name":"Operations research","level":1,"score":0.25200000405311584}],"mesh":[],"locations_count":1,"locations":[{"id":"pmh:oai:doaj.org/article:62b81392026743d19156b3f3be7963d7","doi":null,"is_oa":true,"landing_page_url":"https://doaj.org/article/62b81392026743d19156b3f3be7963d7","pdf_url":null,"source":{"id":"https://openalex.org/S4306401280","display_name":"DOAJ (DOAJ: Directory of Open Access Journals)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by-sa","license_id":"https://openalex.org/licenses/cc-by-sa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Fiabilitate \u015fi Durabilitate, Vol 18, Iss 1, Pp 268-272 (2025)","raw_type":"article"}],"best_oa_location":{"id":"pmh:oai:doaj.org/article:62b81392026743d19156b3f3be7963d7","doi":null,"is_oa":true,"landing_page_url":"https://doaj.org/article/62b81392026743d19156b3f3be7963d7","pdf_url":null,"source":{"id":"https://openalex.org/S4306401280","display_name":"DOAJ (DOAJ: Directory of Open Access Journals)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by-sa","license_id":"https://openalex.org/licenses/cc-by-sa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Fiabilitate \u015fi Durabilitate, Vol 18, Iss 1, Pp 268-272 (2025)","raw_type":"article"},"sustainable_development_goals":[{"display_name":"Affordable and clean energy","score":0.8485000133514404,"id":"https://metadata.un.org/sdg/7"},{"display_name":"Sustainable cities and communities","score":0.7250000238418579,"id":"https://metadata.un.org/sdg/11"},{"display_name":"Climate action","score":0.685699999332428,"id":"https://metadata.un.org/sdg/13"},{"display_name":"Quality education","score":0.6164000034332275,"id":"https://metadata.un.org/sdg/4"}],"sustainable_development_goals_aurora":[],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":[],"abstract_inverted_index":{"This":[0,105],"paper":[1],"presents":[2],"a":[3,19,37,115],"mathematical":[4],"modeling":[5],"approach":[6,106],"for":[7,68,109],"analyzing":[8],"and":[9,44,50,80,92,112,122],"optimizing":[10],"the":[11,25,34,45,65,69],"energy":[12,87,120],"consumption":[13],"of":[14,28,36,40,47,71],"school":[15],"buildings":[16],"using":[17],"EnergyPlus,":[18],"powerful":[20],"simulation":[21],"engine":[22],"developed":[23],"by":[24],"U.S.":[26],"Department":[27],"Energy.":[29],"The":[30,83],"study":[31],"focuses":[32],"on":[33],"creation":[35],"3D":[38],"model":[39,66],"an":[41],"educational":[42,103],"building":[43],"implementation":[46],"HVAC":[48],"systems":[49],"occupancy":[51],"schedules":[52],"to":[53,98],"reflect":[54],"realistic":[55],"usage":[56],"patterns.":[57],"By":[58],"integrating":[59],"thermodynamic":[60],"principles":[61],"with":[62],"simulation-based":[63],"analysis,":[64],"allows":[67],"assessment":[70],"various":[72],"energy-saving":[73],"strategies,":[74],"including":[75],"improved":[76,93],"insulation,":[77],"lighting":[78],"retrofits,":[79],"ventilation":[81],"optimization.":[82],"results":[84],"demonstrate":[85],"how":[86],"performance":[88],"can":[89],"be":[90],"predicted":[91],"through":[94],"model-based":[95],"design,":[96],"contributing":[97],"sustainable":[99],"development":[100],"goals":[101],"in":[102,125],"infrastructure.":[104],"supports":[107],"decision-making":[108],"facility":[110],"managers":[111],"designers,":[113],"offering":[114],"cost-effective":[116],"path":[117],"toward":[118],"reducing":[119],"demand":[121],"carbon":[123],"emissions":[124],"public":[126],"buildings.":[127]},"counts_by_year":[],"updated_date":"2026-08-08T01:25:22.217667","created_date":"2026-02-09T00:00:00"}