{"id":"https://openalex.org/W7128312951","doi":"https://doi.org/10.18503/2311-8318-2025-4(69)-45-53","title":"The Effect of Multi-Stage Reactor-Thyristor Start-Up Control Device on Electrical System Operation when Compensating for Voltage Deviation Over a Wide Range","display_name":"The Effect of Multi-Stage Reactor-Thyristor Start-Up Control Device on Electrical System Operation when Compensating for Voltage Deviation Over a Wide Range","publication_year":2025,"publication_date":"2025-12-25","ids":{"openalex":"https://openalex.org/W7128312951","doi":"https://doi.org/10.18503/2311-8318-2025-4(69)-45-53"},"language":"en","primary_location":{"id":"doi:10.18503/2311-8318-2025-4(69)-45-53","doi":"https://doi.org/10.18503/2311-8318-2025-4(69)-45-53","is_oa":true,"landing_page_url":"https://doi.org/10.18503/2311-8318-2025-4(69)-45-53","pdf_url":null,"source":{"id":"https://openalex.org/S4210207740","display_name":"Electrotechnical Systems and Complexes","issn_l":"2311-8318","issn":["2311-8318","2658-3151"],"is_oa":true,"is_in_doaj":false,"is_core":false,"listed_in":["russia-white-list-3"],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Electrotechnical Systems and Complexes","raw_type":"journal-article"},"parent_works":[],"lineage":["https://openalex.org/W7128312951"],"child_works_count":0,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"diamond","oa_url":"https://doi.org/10.18503/2311-8318-2025-4(69)-45-53","any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5091374476","display_name":"\u0422\u0430\u0431\u0430\u0440\u043e\u0432 \u0411\u0435\u0445\u0440\u0443\u0437 \u0414\u043e\u0432\u0443\u0434\u0445\u043e\u0434\u0436\u0430\u0435\u0432\u0438\u0447","orcid":"https://orcid.org/0000-0001-5878-3755","observed_orcids":["https://orcid.org/0000-0001-5878-3755"]},"institutions":[],"countries":[],"is_corresponding":true,"raw_author_name":"Behruz D. Tabarov","raw_affiliation_strings":[],"raw_orcid":"https://orcid.org/0000-0001-5878-3755","affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":["https://openalex.org/A5091374476"],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.1957,"has_fulltext":false,"cited_by_count":1,"citation_normalized_percentile":{"value":0.33139497,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":91,"max":95},"biblio":{"volume":null,"issue":"4(69)","first_page":"45","last_page":"53"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10573","display_name":"Power Quality and Harmonics","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10573","display_name":"Power Quality and Harmonics","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13093","display_name":"Electric Power Systems and Control","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/voltage-stabilization","display_name":"voltage stabilization","score":0.781000018119812},{"id":"https://openalex.org/keywords/transformer-substation","display_name":"transformer substation","score":0.722000002861023},{"id":"https://openalex.org/keywords/current-distortion","display_name":"current distortion","score":0.5550000071525574},{"id":"https://openalex.org/keywords/power-factor","display_name":"power factor","score":0.6259999871253967},{"id":"https://openalex.org/keywords/energy-performance","display_name":"energy performance","score":0.6359999775886536}],"concepts":[{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.657800018787384},{"id":"https://openalex.org/C66322947","wikidata":"https://www.wikidata.org/wiki/Q11658","display_name":"Transformer","level":3,"score":0.5835999846458435},{"id":"https://openalex.org/C42156128","wikidata":"https://www.wikidata.org/wiki/Q162641","display_name":"Total harmonic distortion","level":3,"score":0.5458999872207642},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.4690999984741211},{"id":"https://openalex.org/C196226539","wikidata":"https://www.wikidata.org/wiki/Q7940752","display_name":"Voltage regulation","level":3,"score":0.4618000090122223},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.4530999958515167},{"id":"https://openalex.org/C153011079","wikidata":"https://www.wikidata.org/wiki/Q5283583","display_name":"Disturbance voltage","level":5,"score":0.4474000036716461},{"id":"https://openalex.org/C196796808","wikidata":"https://www.wikidata.org/wiki/Q132629","display_name":"Electrical network","level":2,"score":0.44510000944137573},{"id":"https://openalex.org/C117323899","wikidata":"https://www.wikidata.org/wiki/Q1907989","display_name":"Distribution transformer","level":4,"score":0.43630000948905945},{"id":"https://openalex.org/C49324399","wikidata":"https://www.wikidata.org/wiki/Q466758","display_name":"Voltage divider","level":3,"score":0.4268999993801117},{"id":"https://openalex.org/C46529443","wikidata":"https://www.wikidata.org/wiki/Q7940750","display_name":"Voltage optimisation","level":4,"score":0.40070000290870667},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.40070000290870667},{"id":"https://openalex.org/C40293303","wikidata":"https://www.wikidata.org/wiki/Q27137","display_name":"Electric power","level":3,"score":0.36090001463890076},{"id":"https://openalex.org/C22958824","wikidata":"https://www.wikidata.org/wiki/Q565668","display_name":"Autotransformer","level":5,"score":0.35499998927116394},{"id":"https://openalex.org/C122940293","wikidata":"https://www.wikidata.org/wiki/Q1755966","display_name":"Tap changer","level":4,"score":0.35280001163482666},{"id":"https://openalex.org/C2780365114","wikidata":"https://www.wikidata.org/wiki/Q169478","display_name":"MATLAB","level":2,"score":0.3504999876022339},{"id":"https://openalex.org/C128624480","wikidata":"https://www.wikidata.org/wiki/Q1504817","display_name":"Low voltage","level":3,"score":0.34119999408721924},{"id":"https://openalex.org/C162175671","wikidata":"https://www.wikidata.org/wiki/Q3749263","display_name":"Electrical equipment","level":2,"score":0.31279999017715454},{"id":"https://openalex.org/C133770746","wikidata":"https://www.wikidata.org/wiki/Q856535","display_name":"Current transformer","level":4,"score":0.2964000105857849},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.28439998626708984},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.28360000252723694},{"id":"https://openalex.org/C15032970","wikidata":"https://www.wikidata.org/wiki/Q851210","display_name":"Dropout voltage","level":4,"score":0.2818000018596649},{"id":"https://openalex.org/C151799858","wikidata":"https://www.wikidata.org/wiki/Q587008","display_name":"Switched-mode power supply","level":3,"score":0.28049999475479126},{"id":"https://openalex.org/C98576551","wikidata":"https://www.wikidata.org/wiki/Q841798","display_name":"Electric potential energy","level":3,"score":0.27459999918937683},{"id":"https://openalex.org/C206658404","wikidata":"https://www.wikidata.org/wiki/Q12725","display_name":"Electricity","level":2,"score":0.27070000767707825},{"id":"https://openalex.org/C125884559","wikidata":"https://www.wikidata.org/wiki/Q369791","display_name":"Linear variable differential transformer","level":5,"score":0.2685999870300293},{"id":"https://openalex.org/C88182573","wikidata":"https://www.wikidata.org/wiki/Q1139740","display_name":"High voltage","level":3,"score":0.26820001006126404},{"id":"https://openalex.org/C9121194","wikidata":"https://www.wikidata.org/wiki/Q5377050","display_name":"Energy efficient transformer","level":5,"score":0.267300009727478},{"id":"https://openalex.org/C110706871","wikidata":"https://www.wikidata.org/wiki/Q851210","display_name":"Voltage regulator","level":3,"score":0.26570001244544983},{"id":"https://openalex.org/C126780896","wikidata":"https://www.wikidata.org/wiki/Q899871","display_name":"Distortion (music)","level":4,"score":0.2502000033855438}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.18503/2311-8318-2025-4(69)-45-53","doi":"https://doi.org/10.18503/2311-8318-2025-4(69)-45-53","is_oa":true,"landing_page_url":"https://doi.org/10.18503/2311-8318-2025-4(69)-45-53","pdf_url":null,"source":{"id":"https://openalex.org/S4210207740","display_name":"Electrotechnical Systems and Complexes","issn_l":"2311-8318","issn":["2311-8318","2658-3151"],"is_oa":true,"is_in_doaj":false,"is_core":false,"listed_in":["russia-white-list-3"],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Electrotechnical Systems and Complexes","raw_type":"journal-article"}],"best_oa_location":{"id":"doi:10.18503/2311-8318-2025-4(69)-45-53","doi":"https://doi.org/10.18503/2311-8318-2025-4(69)-45-53","is_oa":true,"landing_page_url":"https://doi.org/10.18503/2311-8318-2025-4(69)-45-53","pdf_url":null,"source":{"id":"https://openalex.org/S4210207740","display_name":"Electrotechnical Systems and Complexes","issn_l":"2311-8318","issn":["2311-8318","2658-3151"],"is_oa":true,"is_in_doaj":false,"is_core":false,"listed_in":["russia-white-list-3"],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Electrotechnical Systems and Complexes","raw_type":"journal-article"},"sustainable_development_goals":[{"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7","score":0.8485000133514404},{"display_name":"Industry, innovation and infrastructure","id":"https://metadata.un.org/sdg/9","score":0.7207000255584717}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W4416841995","https://openalex.org/W7217530607","https://openalex.org/W4411996022","https://openalex.org/W3157057462","https://openalex.org/W2079323278","https://openalex.org/W2995765936","https://openalex.org/W2990729294","https://openalex.org/W7155032413","https://openalex.org/W7117554573","https://openalex.org/W2142195882"],"abstract_inverted_index":{"The":[0,79,148,283,315],"paper":[1],"is":[2,84,177],"concerned":[3],"with":[4,45,142],"the":[5,12,28,41,67,76,87,97,110,115,119,128,151,155,162,166,170,175,180,183,189,198,208,211,224,231,244,252,258,261,269,273,287,291,294,299,305,312,321,327,332,341,349,362,373],"occurrence":[6],"of":[7,27,34,75,81,89,102,114,135,145,150,165,185,246,260,268,311,337,343,386],"harmonic":[8],"voltage":[9,38,64,111,144,164,176,186,195,209,278,289,296,346,369],"components":[10],"and":[11,31,47,62,91,100,141,169,201,217,238,265,308,335,365,378],"current":[13],"curve":[14],"shape":[15],"distortion":[16,196],"in":[17,66,72,127,179,197,202,210,290,340,348,372],"electrical":[18,103,120,171,270],"engineering":[19],"systems,":[20,104],"as":[21,23,105,107],"well":[22,106],"energy":[24,266,309,339],"indicators,":[25],"unloading":[26],"supply":[29,68,116,167,212,295,313,350,374],"network":[30,69,117,168,213,351],"power":[32,199,262,306,333,376],"transformer":[33,42,139,200,334],"a":[35,60,132,136,143,193,344,353,367,384],"substation":[36,43,140,292],"during":[37],"stabilization":[39,187],"at":[40,272],"input":[44],"standard":[46],"new":[48,322],"multistage":[49],"reactor-thyristor":[50],"start-up":[51,93],"device.":[52],"These":[53,123],"issues":[54],"were":[55,125],"investigated":[56],"when":[57,174,207,220,293,361,366],"there":[58],"was":[59,357],"positive":[61,345],"negative":[63,368],"deviation":[65,112,347],"within":[70,298],"\u00b116%":[71],"\u00b12.5%":[73],"increments":[74],"nominal":[77,225],"level.":[78],"purpose":[80],"these":[82],"studies":[83,124],"to":[85,108,393,399],"determine":[86],"effect":[88,113],"existing":[90],"proposed":[92,156,253,284],"control":[94],"devices":[95],"on":[96,118,131],"sinusoidal":[98,163],"currents":[99,173],"voltages":[101],"identify":[109],"system":[121,172],"operation.":[122],"conducted":[126],"Matlab":[129],"environment":[130],"simulation":[133],"model":[134],"1000":[137],"kV":[138],"6/0.4":[146],"kV.":[147],"results":[149,245,317],"study":[152],"confirmed":[153],"that":[154,251,320,360],"technical":[157,323],"solution":[158],"does":[159,255,329],"not":[160,229,256,330,382,391],"affect":[161],"stabilized":[178],"substation.":[181],"In":[182,242],"process":[184],"between":[188],"limits,":[190],"it":[191,221],"creates":[192],"maximum":[194],"electricity":[203,379],"consumers":[204,336,380],"by":[205,215,218,236,325],"2.98%":[206],"decreases":[214],"-10%":[216],"2.35%":[219],"rises":[222],"from":[223],"level,":[226],"which":[227,389],"do":[228,381],"exceed":[230],"normally":[232],"permissible":[233],"standards":[234],"established":[235,250],"domestic":[237],"foreign":[239],"GOST":[240],"standards.":[241],"addition,":[243],"numerical":[247],"experiments":[248],"have":[249],"device":[254,285,363],"degrade":[257],"values":[259],"coefficients,":[263],"efficiency":[264],"parameters":[267],"system,":[271],"same":[274],"time,":[275],"providing":[276],"continuous":[277],"regulation":[279],"over":[280,352],"wide":[281,354],"ranges.":[282],"maintains":[286],"rated":[288],"deviates":[297],"above":[300],"limits":[301],"and,":[302],"thus":[303],"reduces":[304],"coefficients":[307],"performance":[310],"network.":[314],"research":[316],"also":[318,358,398],"confirm":[319],"solution,":[324],"stabilizing":[326],"voltage,":[328],"overload":[331],"additional":[338],"event":[342],"range.":[355],"It":[356],"shown":[359],"operates":[364],"drop":[370],"occurs":[371],"network,":[375],"transformers":[377],"experience":[383],"shortage":[385],"consumed":[387],"energy,":[388],"leads":[390],"only":[392],"maintaining":[394],"normal":[395],"operation,":[396],"but":[397],"improving":[400],"their":[401],"functioning.":[402]},"counts_by_year":[{"year":2026,"cited_by_count":1}],"updated_date":"2026-10-28T10:33:24.094632","created_date":"2026-02-09T00:00:00"}