{"id":"https://openalex.org/W7127434883","doi":"https://doi.org/10.1109/icps67276.2025.11364882","title":"Real-Time Fault Analysis and System Optimization in EV Controllers with Field-Oriented Control: A Practical Investigation on Monitoring Diagnostics and Enhancements","display_name":"Real-Time Fault Analysis and System Optimization in EV Controllers with Field-Oriented Control: A Practical Investigation on Monitoring Diagnostics and Enhancements","publication_year":2025,"publication_date":"2025-12-07","ids":{"openalex":"https://openalex.org/W7127434883","doi":"https://doi.org/10.1109/icps67276.2025.11364882"},"language":"en","primary_location":{"id":"doi:10.1109/icps67276.2025.11364882","doi":"https://doi.org/10.1109/icps67276.2025.11364882","is_oa":false,"landing_page_url":"https://doi.org/10.1109/icps67276.2025.11364882","pdf_url":null,"source":{"id":"https://openalex.org/S4306498441","display_name":"International Conference on Power Systems (ICPS)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2025 11th International Conference on Power Systems (ICPS)","raw_type":"proceedings-article"},"volume":null,"type":"conference-paper","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5033669946","display_name":"R. Suganya","orcid":"https://orcid.org/0009-0003-1062-3439","observed_orcids":["https://orcid.org/0009-0003-1062-3439"]},"institutions":[{"id":"https://openalex.org/I4405263155","display_name":"SR University","ror":"https://ror.org/039t32v17","country_code":"IN","type":"education","lineage":["https://openalex.org/I4405263155"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"R. Suganya","raw_affiliation_strings":["SR University,School of Engineering,Department of ECE,Warangal,Telangana,India,506371"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"SR University,School of Engineering,Department of ECE,Warangal,Telangana,India,506371","institution_ids":["https://openalex.org/I4405263155"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5122653411","display_name":"L.M.I. Leo Joseph","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4405263155","display_name":"SR University","ror":"https://ror.org/039t32v17","country_code":"IN","type":"education","lineage":["https://openalex.org/I4405263155"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"L.M.I. Leo Joseph","raw_affiliation_strings":["SR University,School of Engineering,Department of ECE,Warangal,Telangana,India,506371"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"SR University,School of Engineering,Department of ECE,Warangal,Telangana,India,506371","institution_ids":["https://openalex.org/I4405263155"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5087528897","display_name":"Sreedhar Kollem","orcid":"https://orcid.org/0000-0002-9203-0404","observed_orcids":["https://orcid.org/0000-0002-9203-0404"]},"institutions":[{"id":"https://openalex.org/I4405263155","display_name":"SR University","ror":"https://ror.org/039t32v17","country_code":"IN","type":"education","lineage":["https://openalex.org/I4405263155"]}],"countries":["IN"],"is_corresponding":false,"raw_author_name":"Sreedhar Kollem","raw_affiliation_strings":["SR University,School of Engineering,Department of ECE,Warangal,Telangana,India,506371"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"SR University,School of Engineering,Department of ECE,Warangal,Telangana,India,506371","institution_ids":["https://openalex.org/I4405263155"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I4405263155"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.0,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"6"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10504","display_name":"Sensorless Control of Electric Motors","score":0.5473999977111816,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10504","display_name":"Sensorless Control of Electric Motors","score":0.5473999977111816,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10808","display_name":"Electric and Hybrid Vehicle Technologies","score":0.24889999628067017,"subfield":{"id":"https://openalex.org/subfields/2203","display_name":"Automotive Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10876","display_name":"Fault Detection and Control Systems","score":0.04670000076293945,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/field-oriented-control","display_name":"field-oriented control","score":0.9440000057220459},{"id":"https://openalex.org/keywords/fault-diagnosis","display_name":"fault diagnosis","score":0.9599999785423279},{"id":"https://openalex.org/keywords/real-time-monitoring","display_name":"real-time monitoring","score":0.9409999847412109},{"id":"https://openalex.org/keywords/thermal-management","display_name":"thermal management","score":0.8859999775886536},{"id":"https://openalex.org/keywords/motor-temperature","display_name":"motor temperature","score":0.796999990940094},{"id":"https://openalex.org/keywords/fault-prioritization","display_name":"fault prioritization","score":0.8500000238418579},{"id":"https://openalex.org/keywords/adaptive-thermal-management","display_name":"adaptive thermal management","score":0.8199999928474426},{"id":"https://openalex.org/keywords/predictive-maintenance","display_name":"predictive maintenance","score":0.8799999952316284},{"id":"https://openalex.org/keywords/machine-learning-for-fault-diagnosis","display_name":"machine learning for fault diagnosis","score":0.7789999842643738}],"concepts":[{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.6359999775886536},{"id":"https://openalex.org/C48044578","wikidata":"https://www.wikidata.org/wiki/Q727490","display_name":"Scalability","level":2,"score":0.5978999733924866},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.515999972820282},{"id":"https://openalex.org/C152745839","wikidata":"https://www.wikidata.org/wiki/Q5438153","display_name":"Fault detection and isolation","level":3,"score":0.47540000081062317},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.4715000092983246},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4399999976158142},{"id":"https://openalex.org/C2777615720","wikidata":"https://www.wikidata.org/wiki/Q11888847","display_name":"Prioritization","level":2,"score":0.40709999203681946},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.40560001134872437},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.39010000228881836},{"id":"https://openalex.org/C114834414","wikidata":"https://www.wikidata.org/wiki/Q15477170","display_name":"Thermal management of electronic devices and systems","level":2,"score":0.3691999912261963},{"id":"https://openalex.org/C17500928","wikidata":"https://www.wikidata.org/wiki/Q959968","display_name":"Control system","level":2,"score":0.36640000343322754},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.3628999888896942},{"id":"https://openalex.org/C108074857","wikidata":"https://www.wikidata.org/wiki/Q3067360","display_name":"Fault management","level":3,"score":0.36059999465942383},{"id":"https://openalex.org/C201995342","wikidata":"https://www.wikidata.org/wiki/Q682496","display_name":"Systems engineering","level":1,"score":0.33709999918937683},{"id":"https://openalex.org/C198783460","wikidata":"https://www.wikidata.org/wiki/Q629173","display_name":"Management system","level":2,"score":0.33640000224113464},{"id":"https://openalex.org/C2775846686","wikidata":"https://www.wikidata.org/wiki/Q643012","display_name":"Condition monitoring","level":2,"score":0.3346000015735626},{"id":"https://openalex.org/C149635348","wikidata":"https://www.wikidata.org/wiki/Q193040","display_name":"Embedded system","level":1,"score":0.32350000739097595},{"id":"https://openalex.org/C132835097","wikidata":"https://www.wikidata.org/wiki/Q7663745","display_name":"System safety","level":2,"score":0.301800012588501},{"id":"https://openalex.org/C107464732","wikidata":"https://www.wikidata.org/wiki/Q235781","display_name":"Adaptive control","level":3,"score":0.30149999260902405},{"id":"https://openalex.org/C176871988","wikidata":"https://www.wikidata.org/wiki/Q72313","display_name":"Electric motor","level":2,"score":0.2770000100135803},{"id":"https://openalex.org/C105637607","wikidata":"https://www.wikidata.org/wiki/Q1786258","display_name":"Drivetrain","level":3,"score":0.27320000529289246},{"id":"https://openalex.org/C2778755073","wikidata":"https://www.wikidata.org/wiki/Q10858537","display_name":"Scale (ratio)","level":2,"score":0.2696000039577484},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.2639999985694885},{"id":"https://openalex.org/C154750914","wikidata":"https://www.wikidata.org/wiki/Q4304910","display_name":"Motor drive","level":2,"score":0.2583000063896179}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/icps67276.2025.11364882","doi":"https://doi.org/10.1109/icps67276.2025.11364882","is_oa":false,"landing_page_url":"https://doi.org/10.1109/icps67276.2025.11364882","pdf_url":null,"source":{"id":"https://openalex.org/S4306498441","display_name":"International Conference on Power Systems (ICPS)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2025 11th International Conference on Power Systems (ICPS)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy","score":0.75},{"id":"https://metadata.un.org/sdg/9","display_name":"Industry, innovation and infrastructure","score":0.6773999929428101}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":19,"referenced_works":["https://openalex.org/W3153959117","https://openalex.org/W4205283615","https://openalex.org/W4206834325","https://openalex.org/W4220672209","https://openalex.org/W4225876525","https://openalex.org/W4313408713","https://openalex.org/W4313889575","https://openalex.org/W4386807711","https://openalex.org/W4389616311","https://openalex.org/W4394627245","https://openalex.org/W4399767918","https://openalex.org/W4401931510","https://openalex.org/W4402495699","https://openalex.org/W4402892240","https://openalex.org/W4403119238","https://openalex.org/W4404563494","https://openalex.org/W4404787967","https://openalex.org/W4405233236","https://openalex.org/W4405975227"],"related_works":["https://openalex.org/W4416367290","https://openalex.org/W7128597483","https://openalex.org/W4416922859","https://openalex.org/W4415458251","https://openalex.org/W7139014357","https://openalex.org/W4411401266","https://openalex.org/W4399801320","https://openalex.org/W7215424826","https://openalex.org/W4383376217","https://openalex.org/W4391725088"],"abstract_inverted_index":{"This":[0,113],"paper":[1],"examines":[2],"the":[3,12,29,62,87,136],"Field-Oriented":[4],"Control":[5],"(FOC)":[6],"for":[7,122],"EV":[8,88,126],"controllers":[9],"monitoring":[10],"in":[11,26,28],"LingBo":[13],"ECU":[14],"Gen5":[15],"GUI":[16],"environment.":[17],"Advanced":[18],"analysis":[19],"and":[20,40,73,84,99,110,120,140],"fault":[21,71,108],"diagnosis":[22,109],"tools":[23],"are":[24,77],"employed":[25],"real-time":[27],"system":[30],"to":[31,80,106],"monitor":[32],"important":[33],"parameters,":[34],"including":[35],"bus":[36],"voltage,":[37],"current,":[38],"speed,":[39],"motor":[41],"temperature.":[42],"Based":[43],"on":[44,95,125],"this":[45],"analysis,":[46],"it":[47],"is":[48],"found":[49],"that":[50,133],"undervoltage":[51],"faults,":[52],"as":[53,55,70],"well":[54],"thermal":[56,101],"management":[57,102],"issues,":[58],"present":[59],"some":[60],"of":[61,138],"most":[63],"significant":[64],"problems":[65],"during":[66],"operation.":[67],"Recommendations,":[68],"such":[69],"prioritization":[72],"enhanced":[74],"cooling":[75],"systems,":[76],"also":[78,92],"presented":[79],"promote":[81],"both":[82],"safety":[83],"efficiency":[85],"within":[86],"controller.":[89],"The":[90],"article":[91],"presents":[93],"ideas":[94],"how":[96],"machine":[97],"learning":[98],"adaptive":[100],"can":[103,134],"be":[104],"integrated":[105],"improve":[107],"predictive":[111],"maintenance.":[112],"concept":[114],"would":[115],"ensure":[116],"high":[117],"performance,":[118],"reliability,":[119],"scalability":[121],"FOC-based":[123],"systems":[124],"applications.":[127],"These":[128],"results":[129],"provide":[130],"crucial":[131],"information":[132],"accelerate":[135],"development":[137],"sustainable":[139],"efficient":[141],"electric":[142],"transportation":[143],"systems.":[144]},"counts_by_year":[],"updated_date":"2026-10-28T10:33:24.094632","created_date":"2026-02-04T00:00:00"}
