{"id":"https://openalex.org/W7127300922","doi":"https://doi.org/10.35833/mpce.2024.001191","title":"Market-oriented Two-stage Reactive Power Regulation for Large-scale Distributed Photovoltaic Entities","display_name":"Market-oriented Two-stage Reactive Power Regulation for Large-scale Distributed Photovoltaic Entities","publication_year":2026,"publication_date":"2026-01-01","ids":{"openalex":"https://openalex.org/W7127300922","doi":"https://doi.org/10.35833/mpce.2024.001191"},"language":"en","primary_location":{"id":"doi:10.35833/mpce.2024.001191","doi":"https://doi.org/10.35833/mpce.2024.001191","is_oa":true,"landing_page_url":"https://doi.org/10.35833/mpce.2024.001191","pdf_url":null,"source":{"id":"https://openalex.org/S4210194934","display_name":"Journal of Modern Power Systems and Clean Energy","issn_l":"2196-5420","issn":["2196-5420","2196-5625"],"is_oa":true,"is_in_doaj":true,"is_core":true,"listed_in":["cwts-core","doaj","dongbi-b","jufo-1","norway-1","oarl","poland-100","russia-white-list-1"],"host_organization":"https://openalex.org/P4310319965","host_organization_name":"Springer Nature","host_organization_lineage":["https://openalex.org/P4310319965"],"host_organization_lineage_names":["Springer Nature"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Journal of Modern Power Systems and Clean Energy","raw_type":"journal-article"},"volume":null,"type":"article","is_traditional":true,"indexed_in":["crossref","doaj"],"open_access":{"is_oa":true,"oa_status":"diamond","oa_url":"https://doi.org/10.35833/mpce.2024.001191","any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5015910159","display_name":"Qiangang Jia","orcid":"https://orcid.org/0000-0002-4074-2039","observed_orcids":["https://orcid.org/0000-0002-4074-2039"]},"institutions":[{"id":"https://openalex.org/I38877650","display_name":"Zhengzhou University","ror":"https://ror.org/04ypx8c21","country_code":"CN","type":"education","lineage":["https://openalex.org/I38877650"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Jia Qiangang","raw_affiliation_strings":["School of Electrical and Information Engineering, Zhengzhou University, Zhengzhou, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"School of Electrical and Information Engineering, Zhengzhou University, Zhengzhou, China","institution_ids":["https://openalex.org/I38877650"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5063734304","display_name":"Jiao Wenshu","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I154099455","display_name":"Shandong University","ror":"https://ror.org/0207yh398","country_code":"CN","type":"education","lineage":["https://openalex.org/I154099455"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Jiao Wenshu","raw_affiliation_strings":["School of Electrical Engineering, Shandong University, Jinan, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"School of Electrical Engineering, Shandong University, Jinan, China","institution_ids":["https://openalex.org/I154099455"]}]},{"author_position":"middle","author":{"id":null,"display_name":"Chen Sijie","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I183067930","display_name":"Shanghai Jiao Tong University","ror":"https://ror.org/0220qvk04","country_code":"CN","type":"education","lineage":["https://openalex.org/I183067930"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Chen Sijie","raw_affiliation_strings":["Key Laboratory of Control of Power Transmission and Conversion, Ministry of Education, Shanghai Jiao Tong University, Shanghai, China","Shanghai Non-Carbon Energy Conversion and Utilization Institute, Shanghai Jiao Tong University, Shanghai, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Key Laboratory of Control of Power Transmission and Conversion, Ministry of Education, Shanghai Jiao Tong University, Shanghai, China","institution_ids":["https://openalex.org/I183067930"]},{"raw_affiliation_string":"Shanghai Non-Carbon Energy Conversion and Utilization Institute, Shanghai Jiao Tong University, Shanghai, China","institution_ids":["https://openalex.org/I183067930"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5124938117","display_name":"Ping Jian","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I183067930","display_name":"Shanghai Jiao Tong University","ror":"https://ror.org/0220qvk04","country_code":"CN","type":"education","lineage":["https://openalex.org/I183067930"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Ping Jian","raw_affiliation_strings":["College of Smart Energy, Shanghai Jiao Tong University, Shanghai, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"College of Smart Energy, Shanghai Jiao Tong University, Shanghai, China","institution_ids":["https://openalex.org/I183067930"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5124940792","display_name":"Yan Zheng","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I183067930","display_name":"Shanghai Jiao Tong University","ror":"https://ror.org/0220qvk04","country_code":"CN","type":"education","lineage":["https://openalex.org/I183067930"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Yan Zheng","raw_affiliation_strings":["Key Laboratory of Control of Power Transmission and Conversion, Ministry of Education, Shanghai Jiao Tong University, Shanghai, China","Shanghai Non-Carbon Energy Conversion and Utilization Institute, Shanghai Jiao Tong University, Shanghai, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Key Laboratory of Control of Power Transmission and Conversion, Ministry of Education, Shanghai Jiao Tong University, Shanghai, China","institution_ids":["https://openalex.org/I183067930"]},{"raw_affiliation_string":"Shanghai Non-Carbon Energy Conversion and Utilization Institute, Shanghai Jiao Tong University, Shanghai, China","institution_ids":["https://openalex.org/I183067930"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5124951298","display_name":"Sun Haitao","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I9086337","display_name":"Taiyuan University of Technology","ror":"https://ror.org/03kv08d37","country_code":"CN","type":"education","lineage":["https://openalex.org/I9086337"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Sun Haitao","raw_affiliation_strings":["College of Electrical and Power Engineering, Taiyuan University of Technology, Taiyuan, China","Key Laboratory of Cleaner Intelligent Control on Coal & Electricity, Ministry of Education, Taiyuan, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"College of Electrical and Power Engineering, Taiyuan University of Technology, Taiyuan, China","institution_ids":["https://openalex.org/I9086337"]},{"raw_affiliation_string":"Key Laboratory of Cleaner Intelligent Control on Coal & Electricity, Ministry of Education, Taiyuan, China","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":4,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.04245814,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"14","issue":"1","first_page":"347","last_page":"356"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10454","display_name":"Optimal Power Flow Distribution","score":0.9624000191688538,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10454","display_name":"Optimal Power Flow Distribution","score":0.9624000191688538,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10424","display_name":"Electric Power System Optimization","score":0.021400000900030136,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10603","display_name":"Smart Grid Energy Management","score":0.012299999594688416,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/reactive-power-control","display_name":"reactive power control","score":0.9449999928474426},{"id":"https://openalex.org/keywords/distributed-photovoltaics","display_name":"distributed photovoltaic generation","score":0.8519999980926514},{"id":"https://openalex.org/keywords/voltage-control","display_name":"voltage regulation","score":0.8569999933242798},{"id":"https://openalex.org/keywords/distribution-networks","display_name":"distribution networks","score":0.7170000076293945},{"id":"https://openalex.org/keywords/economic-efficiency","display_name":"economic efficiency","score":0.8700000047683716},{"id":"https://openalex.org/keywords/radial-distribution-systems","display_name":"radial distribution systems","score":0.6980000138282776}],"concepts":[{"id":"https://openalex.org/C108755667","wikidata":"https://www.wikidata.org/wiki/Q1930258","display_name":"AC power","level":3,"score":0.8804000020027161},{"id":"https://openalex.org/C41291067","wikidata":"https://www.wikidata.org/wiki/Q1897785","display_name":"Photovoltaic system","level":2,"score":0.7013999819755554},{"id":"https://openalex.org/C544738498","wikidata":"https://www.wikidata.org/wiki/Q861135","display_name":"Distributed generation","level":3,"score":0.5411999821662903},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5393000245094299},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.4700999855995178},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.4228000044822693},{"id":"https://openalex.org/C36877392","wikidata":"https://www.wikidata.org/wiki/Q1229571","display_name":"Distributed power","level":3,"score":0.3806999921798706},{"id":"https://openalex.org/C2989491980","wikidata":"https://www.wikidata.org/wiki/Q676081","display_name":"Power market","level":4,"score":0.36629998683929443},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.36160001158714294},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.36039999127388},{"id":"https://openalex.org/C196226539","wikidata":"https://www.wikidata.org/wiki/Q7940752","display_name":"Voltage regulation","level":3,"score":0.34709998965263367},{"id":"https://openalex.org/C2778348673","wikidata":"https://www.wikidata.org/wiki/Q739302","display_name":"Production (economics)","level":2,"score":0.31850001215934753},{"id":"https://openalex.org/C187633118","wikidata":"https://www.wikidata.org/wiki/Q1317949","display_name":"Economic dispatch","level":4,"score":0.3127000033855438},{"id":"https://openalex.org/C46529443","wikidata":"https://www.wikidata.org/wiki/Q7940750","display_name":"Voltage optimisation","level":4,"score":0.3118000030517578},{"id":"https://openalex.org/C195697387","wikidata":"https://www.wikidata.org/wiki/Q5608561","display_name":"Grid-connected photovoltaic power system","level":5,"score":0.3086000084877014},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.2957000136375427},{"id":"https://openalex.org/C423512","wikidata":"https://www.wikidata.org/wiki/Q383973","display_name":"Electricity generation","level":3,"score":0.2863999903202057},{"id":"https://openalex.org/C2780848588","wikidata":"https://www.wikidata.org/wiki/Q210494","display_name":"Power Balance","level":3,"score":0.2849000096321106},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.28360000252723694},{"id":"https://openalex.org/C181361822","wikidata":"https://www.wikidata.org/wiki/Q556030","display_name":"Power-flow study","level":4,"score":0.2815999984741211},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.27469998598098755},{"id":"https://openalex.org/C2989126829","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Power network","level":4,"score":0.2630000114440918},{"id":"https://openalex.org/C59407501","wikidata":"https://www.wikidata.org/wiki/Q550341","display_name":"Volt-ampere reactive","level":5,"score":0.25850000977516174},{"id":"https://openalex.org/C120314980","wikidata":"https://www.wikidata.org/wiki/Q180634","display_name":"Distributed computing","level":1,"score":0.2542000114917755},{"id":"https://openalex.org/C56685638","wikidata":"https://www.wikidata.org/wiki/Q2300474","display_name":"Power control","level":3,"score":0.25130000710487366}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.35833/mpce.2024.001191","doi":"https://doi.org/10.35833/mpce.2024.001191","is_oa":true,"landing_page_url":"https://doi.org/10.35833/mpce.2024.001191","pdf_url":null,"source":{"id":"https://openalex.org/S4210194934","display_name":"Journal of Modern Power Systems and Clean Energy","issn_l":"2196-5420","issn":["2196-5420","2196-5625"],"is_oa":true,"is_in_doaj":true,"is_core":true,"listed_in":["cwts-core","doaj","dongbi-b","jufo-1","norway-1","oarl","poland-100","russia-white-list-1"],"host_organization":"https://openalex.org/P4310319965","host_organization_name":"Springer Nature","host_organization_lineage":["https://openalex.org/P4310319965"],"host_organization_lineage_names":["Springer Nature"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Journal of Modern Power Systems and Clean Energy","raw_type":"journal-article"}],"best_oa_location":{"id":"doi:10.35833/mpce.2024.001191","doi":"https://doi.org/10.35833/mpce.2024.001191","is_oa":true,"landing_page_url":"https://doi.org/10.35833/mpce.2024.001191","pdf_url":null,"source":{"id":"https://openalex.org/S4210194934","display_name":"Journal of Modern Power Systems and Clean Energy","issn_l":"2196-5420","issn":["2196-5420","2196-5625"],"is_oa":true,"is_in_doaj":true,"is_core":true,"listed_in":["cwts-core","doaj","dongbi-b","jufo-1","norway-1","oarl","poland-100","russia-white-list-1"],"host_organization":"https://openalex.org/P4310319965","host_organization_name":"Springer Nature","host_organization_lineage":["https://openalex.org/P4310319965"],"host_organization_lineage_names":["Springer Nature"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Journal of Modern Power Systems and Clean Energy","raw_type":"journal-article"},"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy","score":0.9853000044822693},{"id":"https://metadata.un.org/sdg/9","display_name":"Industry, innovation and infrastructure","score":0.7207000255584717}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W4410394086","https://openalex.org/W6884759261","https://openalex.org/W3204491399","https://openalex.org/W4293211503","https://openalex.org/W3155936292","https://openalex.org/W4395448421","https://openalex.org/W2047327441","https://openalex.org/W4406906208","https://openalex.org/W1539212184","https://openalex.org/W7155094607"],"abstract_inverted_index":{"Distributed":[0],"photovoltaic":[1],"(PV)":[2],"entities":[3,22,119],"can":[4],"be":[5],"coordinated":[6],"to":[7,30,73,78,103,120],"provide":[8,79],"reactive":[9,24,56,67,80,97,106,144],"power":[10,25,57,68,81,98,107,145],"for":[11,146],"voltage":[12],"regulation":[13,58],"in":[14,142],"distribution":[15,133],"networks.":[16],"However,":[17],"integrating":[18],"large-scale":[19,147],"distributed":[20,110,148],"PV":[21,37,76,111,118,149],"into":[23],"optimization":[26],"makes":[27],"it":[28],"difficult":[29],"balance":[31],"the":[32,40,45,61,91,105,114,136,139],"individual":[33],"benefit":[34],"of":[35,44,109,116,138],"each":[36,75],"entity":[38,77],"with":[39],"overall":[41],"economic":[42,123],"efficiency":[43],"system.":[46],"To":[47],"address":[48],"this":[49],"challenge,":[50],"we":[51],"propose":[52],"a":[53,64,94,129],"market-oriented":[54],"two-stage":[55],"method.":[59],"At":[60,90],"first":[62],"stage,":[63,93],"long-term":[65],"multi-layer":[66,96],"capacity":[69],"market":[70],"is":[71,101],"created":[72],"incentivize":[74],"capacity,":[82],"while":[83],"ensuring":[84],"their":[85],"financial":[86],"interests":[87],"are":[88],"guaranteed.":[89],"second":[92],"real-time":[95],"dispatch":[99,115],"mechanism":[100],"introduced":[102],"manage":[104],"generation":[108],"entities,":[112],"prioritizing":[113],"lower-cost":[117],"maximize":[121],"system-wide":[122],"efficiency.":[124],"Simulation":[125],"results":[126],"based":[127],"on":[128],"real":[130],"Finnish":[131],"radial":[132],"network":[134],"demonstrate":[135],"effectiveness":[137],"proposed":[140],"method":[141],"optimizing":[143],"entities.":[150]},"counts_by_year":[],"updated_date":"2026-10-14T16:39:01.820549","created_date":"2026-02-04T00:00:00"}
