{"id":"https://openalex.org/W7127054574","doi":"https://doi.org/10.1002/9781394442300.ch8","title":"Differential Pressure Flowmeters","display_name":"Differential Pressure Flowmeters","alternate_titles":[],"publication_year":2026,"publication_date":"2026-01-22","ids":{"openalex":"https://openalex.org/W7127054574","doi":"https://doi.org/10.1002/9781394442300.ch8"},"language":"en","primary_location":{"id":"doi:10.1002/9781394442300.ch8","doi":"https://doi.org/10.1002/9781394442300.ch8","is_oa":false,"landing_page_url":"https://doi.org/10.1002/9781394442300.ch8","pdf_url":null,"source":{"id":"https://openalex.org/S4306464293","display_name":"Wiley eBooks","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/P4310320595","host_organization_name":"Wiley","host_organization_lineage":["https://openalex.org/P4310320595"],"host_organization_lineage_names":["Wiley"],"type":"ebook platform"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Flow Measurement","raw_type":"other"},"parent_works":[{"id":"https://openalex.org/W7127044596","display_name":"Flow Measurement","relationship":"volume"}],"lineage":["https://openalex.org/W7127054574","https://openalex.org/W7127044596"],"child_works_count":0,"type":"book-chapter","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5146702799","display_name":"D. W. Spitzer","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":true,"raw_author_name":"D. W. Spitzer","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":["https://openalex.org/A5146702799"],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.0,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"129","last_page":"188"},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T12537","display_name":"Flow Measurement and Analysis","score":1.0,"subfield":{"id":"https://openalex.org/subfields/3105","display_name":"Instrumentation"},"field":{"id":"https://openalex.org/fields/31","display_name":"Physics and Astronomy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T12537","display_name":"Flow Measurement and Analysis","score":1.0,"subfield":{"id":"https://openalex.org/subfields/3105","display_name":"Instrumentation"},"field":{"id":"https://openalex.org/fields/31","display_name":"Physics and Astronomy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11700","display_name":"Hemodynamic Monitoring and Therapy","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2746","display_name":"Surgery"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T12564","display_name":"Sensor Technology and Measurement Systems","score":0.0,"subfield":{"id":"https://openalex.org/subfields/3105","display_name":"Instrumentation"},"field":{"id":"https://openalex.org/fields/31","display_name":"Physics and Astronomy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/differential-pressure-flowmeters","display_name":"differential pressure flowmeters","score":1.0},{"id":"https://openalex.org/keywords/orifice-flowmeter","display_name":"orifice flowmeter","score":0.8659999966621399},{"id":"https://openalex.org/keywords/venturi","display_name":"venturi","score":0.8899999856948853},{"id":"https://openalex.org/keywords/pitot-static-tube","display_name":"pitot-static tube","score":0.9900000095367432},{"id":"https://openalex.org/keywords/flow-rate-measurement","display_name":"flow rate measurement","score":0.7590000033378601},{"id":"https://openalex.org/keywords/pipe-flow","display_name":"pipe flow","score":0.7540000081062317},{"id":"https://openalex.org/keywords/smart-transmitters","display_name":"smart transmitters","score":0.7609999775886536}],"concepts":[{"id":"https://openalex.org/C16302685","wikidata":"https://www.wikidata.org/wiki/Q15091623","display_name":"Flow measurement","level":2,"score":0.7055000066757202},{"id":"https://openalex.org/C2984663118","wikidata":"https://www.wikidata.org/wiki/Q7424019","display_name":"Differential pressure","level":2,"score":0.6872000098228455},{"id":"https://openalex.org/C21423434","wikidata":"https://www.wikidata.org/wiki/Q725699","display_name":"Venturi effect","level":3,"score":0.6751999855041504},{"id":"https://openalex.org/C162037100","wikidata":"https://www.wikidata.org/wiki/Q56218","display_name":"Pitot tube","level":3,"score":0.614300012588501},{"id":"https://openalex.org/C81862102","wikidata":"https://www.wikidata.org/wiki/Q1240867","display_name":"Orifice plate","level":3,"score":0.5396000146865845},{"id":"https://openalex.org/C194242075","wikidata":"https://www.wikidata.org/wiki/Q546776","display_name":"Body orifice","level":2,"score":0.5353999733924866},{"id":"https://openalex.org/C2777551473","wikidata":"https://www.wikidata.org/wiki/Q2093072","display_name":"Tube (container)","level":2,"score":0.5006999969482422},{"id":"https://openalex.org/C57879066","wikidata":"https://www.wikidata.org/wiki/Q41217","display_name":"Mechanics","level":1,"score":0.48809999227523804},{"id":"https://openalex.org/C80264047","wikidata":"https://www.wikidata.org/wiki/Q7424019","display_name":"Pressure measurement","level":2,"score":0.47360000014305115},{"id":"https://openalex.org/C92854067","wikidata":"https://www.wikidata.org/wiki/Q5462091","display_name":"Flow conditioning","level":4,"score":0.46459999680519104},{"id":"https://openalex.org/C38349280","wikidata":"https://www.wikidata.org/wiki/Q1434290","display_name":"Flow (mathematics)","level":2,"score":0.4584999978542328},{"id":"https://openalex.org/C172120300","wikidata":"https://www.wikidata.org/wiki/Q1134348","display_name":"Volumetric flow rate","level":2,"score":0.42500001192092896},{"id":"https://openalex.org/C93226319","wikidata":"https://www.wikidata.org/wiki/Q193137","display_name":"Differential (mechanical device)","level":2,"score":0.4023999869823456},{"id":"https://openalex.org/C41325743","wikidata":"https://www.wikidata.org/wiki/Q1261040","display_name":"Pressure sensor","level":2,"score":0.384799987077713},{"id":"https://openalex.org/C132643394","wikidata":"https://www.wikidata.org/wiki/Q7233264","display_name":"Positive displacement meter","level":2,"score":0.3709000051021576},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.353300005197525},{"id":"https://openalex.org/C158522163","wikidata":"https://www.wikidata.org/wiki/Q2406217","display_name":"Static pressure","level":2,"score":0.3476000130176544},{"id":"https://openalex.org/C90278072","wikidata":"https://www.wikidata.org/wiki/Q216320","display_name":"Fluid dynamics","level":2,"score":0.34619998931884766},{"id":"https://openalex.org/C204323151","wikidata":"https://www.wikidata.org/wiki/Q905424","display_name":"Range (aeronautics)","level":2,"score":0.33320000767707825},{"id":"https://openalex.org/C24890656","wikidata":"https://www.wikidata.org/wiki/Q82811","display_name":"Acoustics","level":1,"score":0.3271999955177307},{"id":"https://openalex.org/C27805115","wikidata":"https://www.wikidata.org/wiki/Q960824","display_name":"Magnetic flow meter","level":3,"score":0.3255999982357025},{"id":"https://openalex.org/C114088122","wikidata":"https://www.wikidata.org/wiki/Q1261069","display_name":"Pressure drop","level":2,"score":0.30869999527931213},{"id":"https://openalex.org/C143428516","wikidata":"https://www.wikidata.org/wiki/Q1794809","display_name":"Flow coefficient","level":3,"score":0.295199990272522},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.29170000553131104},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.2913999855518341},{"id":"https://openalex.org/C166693061","wikidata":"https://www.wikidata.org/wiki/Q5462119","display_name":"Flow velocity","level":3,"score":0.2572000026702881},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.2515000104904175}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1002/9781394442300.ch8","doi":"https://doi.org/10.1002/9781394442300.ch8","is_oa":false,"landing_page_url":"https://doi.org/10.1002/9781394442300.ch8","pdf_url":null,"source":{"id":"https://openalex.org/S4306464293","display_name":"Wiley eBooks","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/P4310320595","host_organization_name":"Wiley","host_organization_lineage":["https://openalex.org/P4310320595"],"host_organization_lineage_names":["Wiley"],"type":"ebook platform"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Flow Measurement","raw_type":"other"}],"best_oa_location":null,"sustainable_development_goals":[],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W2204377803","https://openalex.org/W2478469769","https://openalex.org/W1500542978","https://openalex.org/W2499187952","https://openalex.org/W2891020367","https://openalex.org/W2565791979","https://openalex.org/W7127057042","https://openalex.org/W3020923696","https://openalex.org/W797242200","https://openalex.org/W2990542324"],"abstract_inverted_index":{"For":[0],"many":[1,133],"years":[2],"differential":[3,64],"pressure":[4,31,55,65,127],"types":[5],"of":[6,40,61,99,107,117,136],"flowmeters":[7,32,56],"have":[8],"been":[9],"the":[10,42,45,49,59,74,88],"most":[11,50],"widely":[12,51],"applied":[13,52],"flow":[14,76,85],"rate":[15],"measuring":[16],"device":[17],"for":[18],"fluid":[19,75],"flows":[20],"in":[21,83,105],"pipes":[22],"that":[23,69],"require":[24],"accurate":[25],"measurement":[26],"at":[27],"reasonable":[28],"cost.":[29],"Differential":[30,54],"are":[33],"also":[34,140],"known":[35],"as":[36,102],"head-type":[37,43],"meters,":[38,44],"and,":[39],"all":[41],"orifice":[46],"flowmeter":[47],"is":[48,80],"device.":[53],"operate":[57],"on":[58],"principle":[60],"developing":[62],"a":[63,67,118,146],"across":[66],"restriction":[68],"can":[70,139],"be":[71,95,141],"related":[72],"to":[73,94],"rate.":[77],"A":[78],"venturi":[79],"often":[81],"used":[82],"dirty":[84],"streams":[86],"since":[87],"smooth":[89],"entry":[90],"allows":[91],"foreign":[92],"material":[93],"swept":[96],"through":[97,145],"instead":[98],"building":[100],"up":[101],"it":[103],"would":[104],"front":[106],"an":[108,114,122],"orifice.":[109],"The":[110,129],"Pitot-static":[111],"tube":[112,120,124],"has":[113],"integral":[115],"construction":[116],"Pitot":[119],"and":[121,132],"annular":[123],"with":[125],"static":[126],"ports.":[128],"operating":[130],"range":[131],"other":[134],"parameters":[135],"smart":[137],"transmitters":[138],"changed":[142],"during":[143],"operation":[144],"digital":[147],"communicator.":[148]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W7127054574","counts_by_year":[],"updated_date":"2026-11-14T11:04:58.165337","created_date":"2026-02-03T00:00:00"}
