{"id":"https://openalex.org/W7123360253","doi":"https://doi.org/10.35583/js.v13i2.397","title":"Pengaruh Pergantian dan Uprating Transformator Distribusi 20 KV Terhadap Beban Sekunder Transformator","display_name":"Pengaruh Pergantian dan Uprating Transformator Distribusi 20 KV Terhadap Beban Sekunder Transformator","publication_year":2025,"publication_date":"2025-12-30","ids":{"openalex":"https://openalex.org/W7123360253","doi":"https://doi.org/10.35583/js.v13i2.397"},"language":"id","primary_location":{"id":"doi:10.35583/js.v13i2.397","doi":"https://doi.org/10.35583/js.v13i2.397","is_oa":true,"landing_page_url":"https://doi.org/10.35583/js.v13i2.397","pdf_url":"https://ejournal.sttp-yds.ac.id/index.php/js/article/download/397/268","source":{"id":"https://openalex.org/S4210201718","display_name":"SAINSTEK International Journal on Applied Science Advanced Technology and Informatics","issn_l":"1410-8070","issn":["1410-8070","2460-1039","2830-6953"],"is_oa":true,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"SAINSTEK","raw_type":"journal-article"},"volume":null,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"diamond","oa_url":"https://ejournal.sttp-yds.ac.id/index.php/js/article/download/397/268","any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5048701513","display_name":"Fadhli Palaha","orcid":"https://orcid.org/0000-0002-2971-0001","observed_orcids":["https://orcid.org/0000-0002-2971-0001"]},"institutions":[{"id":"https://openalex.org/I4405274115","display_name":"Sekolah Tinggi Teknologi Pekanbaru","ror":"https://ror.org/013ppvd87","country_code":"ID","type":"education","lineage":["https://openalex.org/I4405274115"]}],"countries":["ID"],"is_corresponding":false,"raw_author_name":"Fadhli Palaha","raw_affiliation_strings":["Sekolah Tinggi Teknologi Pekanbaru"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Sekolah Tinggi Teknologi Pekanbaru","institution_ids":["https://openalex.org/I4405274115"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5035538488","display_name":"Machdalena Machdalena","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4405274115","display_name":"Sekolah Tinggi Teknologi Pekanbaru","ror":"https://ror.org/013ppvd87","country_code":"ID","type":"education","lineage":["https://openalex.org/I4405274115"]}],"countries":["ID"],"is_corresponding":false,"raw_author_name":"Machdalena Machdalena","raw_affiliation_strings":["Sekolah Tinggi Teknologi Pekanbaru"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Sekolah Tinggi Teknologi Pekanbaru","institution_ids":["https://openalex.org/I4405274115"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5122905360","display_name":"Adli Fajrian","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4405274115","display_name":"Sekolah Tinggi Teknologi Pekanbaru","ror":"https://ror.org/013ppvd87","country_code":"ID","type":"education","lineage":["https://openalex.org/I4405274115"]}],"countries":["ID"],"is_corresponding":false,"raw_author_name":"Adli Fajrian","raw_affiliation_strings":["Sekolah Tinggi Teknologi Pekanbaru"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Sekolah Tinggi Teknologi Pekanbaru","institution_ids":["https://openalex.org/I4405274115"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5103179727","display_name":"Ermawati Ermawati","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4405274115","display_name":"Sekolah Tinggi Teknologi Pekanbaru","ror":"https://ror.org/013ppvd87","country_code":"ID","type":"education","lineage":["https://openalex.org/I4405274115"]}],"countries":["ID"],"is_corresponding":false,"raw_author_name":"Ermawati Ermawati","raw_affiliation_strings":["Sekolah Tinggi Teknologi Pekanbaru"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Sekolah Tinggi Teknologi Pekanbaru","institution_ids":["https://openalex.org/I4405274115"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":["https://openalex.org/I4405274115"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":true,"cited_by_count":0,"citation_normalized_percentile":{"value":0.0,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"13","issue":"2","first_page":"233","last_page":"237"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11343","display_name":"Power Transformer Diagnostics and Insulation","score":0.33959999680519104,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11343","display_name":"Power Transformer Diagnostics and Insulation","score":0.33959999680519104,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14502","display_name":"High-Voltage Power Transmission Systems","score":0.2517000138759613,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10454","display_name":"Optimal Power Flow Distribution","score":0.15469999611377716,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/secondary-load","display_name":"secondary load","score":0.7910000085830688},{"id":"https://openalex.org/keywords/transformer-efficiency","display_name":"transformer efficiency","score":0.7839999794960022},{"id":"https://openalex.org/keywords/transformer-losses","display_name":"transformer losses","score":0.7409999966621399},{"id":"https://openalex.org/keywords/load-unbalance","display_name":"load unbalance","score":0.9079999923706055},{"id":"https://openalex.org/keywords/distribution-system-performance","display_name":"distribution system performance","score":0.597000002861023},{"id":"https://openalex.org/keywords/transformer-life-extension","display_name":"transformer life extension","score":0.6909999847412109}],"concepts":[{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.6873000264167786},{"id":"https://openalex.org/C109214941","wikidata":"https://www.wikidata.org/wiki/Q18334","display_name":"Particle physics","level":1,"score":0.2425999939441681},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.21150000393390656},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.20600000023841858},{"id":"https://openalex.org/C66322947","wikidata":"https://www.wikidata.org/wiki/Q11658","display_name":"Transformer","level":3,"score":0.1873999983072281},{"id":"https://openalex.org/C178550888","wikidata":"https://www.wikidata.org/wiki/Q2043282","display_name":"Business administration","level":1,"score":0.18729999661445618},{"id":"https://openalex.org/C61352017","wikidata":"https://www.wikidata.org/wiki/Q211058","display_name":"Circuit breaker","level":2,"score":0.17239999771118164},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.15119999647140503},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.14180000126361847},{"id":"https://openalex.org/C2776058289","wikidata":"https://www.wikidata.org/wiki/Q7039313","display_name":"Niobium-tin","level":4,"score":0.13819999992847443}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.35583/js.v13i2.397","doi":"https://doi.org/10.35583/js.v13i2.397","is_oa":true,"landing_page_url":"https://doi.org/10.35583/js.v13i2.397","pdf_url":"https://ejournal.sttp-yds.ac.id/index.php/js/article/download/397/268","source":{"id":"https://openalex.org/S4210201718","display_name":"SAINSTEK International Journal on Applied Science Advanced Technology and Informatics","issn_l":"1410-8070","issn":["1410-8070","2460-1039","2830-6953"],"is_oa":true,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"SAINSTEK","raw_type":"journal-article"}],"best_oa_location":{"id":"doi:10.35583/js.v13i2.397","doi":"https://doi.org/10.35583/js.v13i2.397","is_oa":true,"landing_page_url":"https://doi.org/10.35583/js.v13i2.397","pdf_url":"https://ejournal.sttp-yds.ac.id/index.php/js/article/download/397/268","source":{"id":"https://openalex.org/S4210201718","display_name":"SAINSTEK International Journal on Applied Science Advanced Technology and Informatics","issn_l":"1410-8070","issn":["1410-8070","2460-1039","2830-6953"],"is_oa":true,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"SAINSTEK","raw_type":"journal-article"},"sustainable_development_goals":[{"display_name":"Industry, innovation and infrastructure","score":1.0,"id":"https://metadata.un.org/sdg/9"},{"display_name":"Affordable and clean energy","score":0.5690000057220459,"id":"https://metadata.un.org/sdg/7"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":true,"pdf":true},"content_urls":{"pdf":"https://content.openalex.org/works/W7123360253.pdf","grobid_xml":"https://content.openalex.org/works/W7123360253.grobid-xml"},"referenced_works_count":9,"referenced_works":["https://openalex.org/W2169253422","https://openalex.org/W2945009840","https://openalex.org/W3158136706","https://openalex.org/W3201397609","https://openalex.org/W4240154266","https://openalex.org/W4283716633","https://openalex.org/W4293230883","https://openalex.org/W4319779326","https://openalex.org/W4386004323"],"related_works":["https://openalex.org/W7216998640","https://openalex.org/W7215385216","https://openalex.org/W7220006469","https://openalex.org/W7217212842","https://openalex.org/W4406516236","https://openalex.org/W7017281727","https://openalex.org/W4389202891","https://openalex.org/W4386162105","https://openalex.org/W4386325579","https://openalex.org/W7128293947"],"abstract_inverted_index":{"Penelitian":[0],"ini":[1],"menganalisis":[2],"pengaruh":[3],"pergantian":[4],"dan":[5,44,82],"uprating":[6],"transformator":[7,14],"distribusi":[8],"20":[9],"kV":[10],"terhadap":[11],"beban":[12,42],"sekunder":[13],"di":[15],"PLN":[16],"ULP":[17],"Pasir":[18],"Pengaraian.":[19],"Uprating":[20,72],"dilakukan":[21],"pada":[22],"trafo":[23],"DD":[24],"23":[25],"dari":[26,51,58,68],"kapasitas":[27],"100":[28],"kVA":[29],"menjadi":[30,53,61,70],"200":[31],"kVA.":[32],"Pengukuran":[33],"meliputi":[34],"arus,":[35],"tegangan,":[36],"efisiensi,":[37],"rugi":[38,56,80],"daya,":[39],"serta":[40,64],"ketidakseimbangan":[41],"sebelum":[43],"sesudah":[45],"uprating.":[46],"Hasil":[47],"menunjukkan":[48],"peningkatan":[49],"efisiensi":[50],"96%":[52],"97,05%,":[54],"penurunan":[55,65],"daya":[57],"20,9":[59],"W":[60],"18,92":[62],"W,":[63],"unbalance":[66],"load":[67],"79%":[69],"14%.":[71],"terbukti":[73],"efektif":[74],"meningkatkan":[75],"kinerja":[76],"sistem":[77],"distribusi,":[78],"menurunkan":[79],"energi,":[81],"memperpanjang":[83],"umur":[84],"transformator.":[85]},"counts_by_year":[],"updated_date":"2026-11-04T10:54:05.112534","created_date":"2026-01-14T00:00:00"}