{"id":"https://openalex.org/W7098432016","doi":null,"title":"Related Collections","display_name":"Related Collections","publication_year":2004,"publication_date":"2004-01-01","ids":{"openalex":"https://openalex.org/W7098432016"},"language":"en","primary_location":{"id":"pmh:oai:CiteSeerX.psu:10.1.1.589.6461","doi":null,"is_oa":false,"landing_page_url":"http://citeseerx.ist.psu.edu/viewdoc/summary?doi=10.1.1.589.6461","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"http://files.sld.cu/hta/files/2009/03/2005-usa-recommendations-for-blood-pressure-measurement-in-humans-and-experimental-animals.pdf","raw_type":"text"},"volume":null,"type":"article","is_traditional":true,"indexed_in":[],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5085505111","display_name":"Daniel W. Jones","orcid":"https://orcid.org/0000-0003-1347-729X","observed_orcids":["https://orcid.org/0000-0003-1347-729X"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Daniel W. Jones","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":null,"display_name":"Md Theodore Kurtz","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Md Theodore Kurtz","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5028146354","display_name":"Sheldon G. Sheps","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Sheldon G. Sheps","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":null,"display_name":"Md Edward","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Md Edward","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"last","author":{"id":null,"display_name":"J. Roccella","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"J. Roccella","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.58308396,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":true,"primary_topic":{"id":"https://openalex.org/T10144","display_name":"Blood Pressure and Hypertension Studies","score":0.9970999956130981,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},"topics":[{"id":"https://openalex.org/T10144","display_name":"Blood Pressure and Hypertension Studies","score":0.9970999956130981,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T11196","display_name":"Non-Invasive Vital Sign Monitoring","score":0.0010000000474974513,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10924","display_name":"Cardiovascular Health and Disease Prevention","score":0.0005000000237487257,"subfield":{"id":"https://openalex.org/subfields/2705","display_name":"Cardiology and Cardiovascular Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/blood-pressure-measurement","display_name":"blood pressure measurement","score":0.9679999947547913},{"id":"https://openalex.org/keywords/auscultatory-method","display_name":"auscultatory method","score":0.828000009059906},{"id":"https://openalex.org/keywords/korotkoff-sounds","display_name":"Korotkoff sounds","score":0.9570000171661377},{"id":"https://openalex.org/keywords/mercury-sphygmomanometer","display_name":"mercury sphygmomanometer","score":0.9769999980926514},{"id":"https://openalex.org/keywords/aneroid-sphygmomanometer","display_name":"aneroid sphygmomanometer","score":0.9120000004768372},{"id":"https://openalex.org/keywords/oscillometric-method","display_name":"oscillometric method","score":0.8899999856948853},{"id":"https://openalex.org/keywords/self-monitoring-of-blood-pressure","display_name":"self-measured blood pressure","score":0.7900000214576721},{"id":"https://openalex.org/keywords/office-blood-pressure","display_name":"office blood pressure","score":0.6700000166893005},{"id":"https://openalex.org/keywords/cuff-size","display_name":"cuff size","score":0.5529999732971191},{"id":"https://openalex.org/keywords/observer-training","display_name":"observer training","score":0.875},{"id":"https://openalex.org/keywords/patient-positioning","display_name":"patient positioning","score":0.6340000033378601},{"id":"https://openalex.org/keywords/hypertension","display_name":"hypertension","score":0.33799999952316284}],"concepts":[{"id":"https://openalex.org/C2910533495","wikidata":"https://www.wikidata.org/wiki/Q503968","display_name":"Sphygmomanometer","level":3,"score":0.7516000270843506},{"id":"https://openalex.org/C84393581","wikidata":"https://www.wikidata.org/wiki/Q82642","display_name":"Blood pressure","level":2,"score":0.6029000282287598},{"id":"https://openalex.org/C2780017030","wikidata":"https://www.wikidata.org/wiki/Q368366","display_name":"Cuff","level":2,"score":0.5709999799728394},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.49939998984336853},{"id":"https://openalex.org/C80264047","wikidata":"https://www.wikidata.org/wiki/Q7424019","display_name":"Pressure measurement","level":2,"score":0.42329999804496765},{"id":"https://openalex.org/C2777777548","wikidata":"https://www.wikidata.org/wiki/Q206040","display_name":"Mercury (programming language)","level":2,"score":0.41119998693466187},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.39739999175071716},{"id":"https://openalex.org/C165838908","wikidata":"https://www.wikidata.org/wiki/Q736777","display_name":"Calibration","level":2,"score":0.3939000070095062},{"id":"https://openalex.org/C2780704645","wikidata":"https://www.wikidata.org/wiki/Q9251458","display_name":"Observer (physics)","level":2,"score":0.3280999958515167},{"id":"https://openalex.org/C41325743","wikidata":"https://www.wikidata.org/wiki/Q1261040","display_name":"Pressure sensor","level":2,"score":0.29840001463890076},{"id":"https://openalex.org/C2779055095","wikidata":"https://www.wikidata.org/wiki/Q162339","display_name":"Stethoscope","level":2,"score":0.29600000381469727},{"id":"https://openalex.org/C56318395","wikidata":"https://www.wikidata.org/wiki/Q215928","display_name":"Transducer","level":2,"score":0.29260000586509705},{"id":"https://openalex.org/C2777324038","wikidata":"https://www.wikidata.org/wiki/Q779054","display_name":"Auscultation","level":2,"score":0.2694000005722046},{"id":"https://openalex.org/C136229726","wikidata":"https://www.wikidata.org/wiki/Q327092","display_name":"Biomedical engineering","level":1,"score":0.25200000405311584}],"mesh":[],"locations_count":1,"locations":[{"id":"pmh:oai:CiteSeerX.psu:10.1.1.589.6461","doi":null,"is_oa":false,"landing_page_url":"http://citeseerx.ist.psu.edu/viewdoc/summary?doi=10.1.1.589.6461","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"http://files.sld.cu/hta/files/2009/03/2005-usa-recommendations-for-blood-pressure-measurement-in-humans-and-experimental-animals.pdf","raw_type":"text"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/3","display_name":"Good health and well-being","score":0.9391000270843506}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W7097226869","https://openalex.org/W2484483641","https://openalex.org/W3118252656","https://openalex.org/W7147148485","https://openalex.org/W4205468630","https://openalex.org/W2521047529","https://openalex.org/W2431092857","https://openalex.org/W7123756359","https://openalex.org/W21463355","https://openalex.org/W1904618591"],"abstract_inverted_index":{"Accurate":[0],"measurement":[1,37],"of":[2,34,47,57,81,115,124,127,132],"blood":[3,12,148],"pressure":[4,149],"is":[5,59,109,139],"essential":[6],"to":[7,10,16,30,100,118],"classify":[8],"individuals,":[9],"ascertain":[11],"pressure\u2013related":[13],"risk,":[14],"and":[15,26,44,61,106,130,154],"guide":[17],"management.":[18],"The":[19,55,85],"auscultatory":[20],"technique":[21],"with":[22,147,164],"a":[23],"trained":[24],"observer":[25],"mercury":[27,58,82],"sphygmomanometer":[28],"continues":[29],"be":[31,89,104,158],"the":[32,39,42,48,113,128],"method":[33,87],"choice":[35],"for":[36,91],"in":[38,52,151],"office,":[40],"using":[41],"first":[43],"fifth":[45],"phases":[46],"Korotkoff":[49],"sounds,":[50],"including":[51],"pregnant":[53],"women.":[54],"use":[56,77],"declining,":[60],"alternatives":[62],"are":[63,67,135],"needed.":[64],"Aneroid":[65],"devices":[66,75,96],"suitable,":[68],"but":[69,94],"they":[70,156],"require":[71],"frequent":[72],"calibration.":[73],"Hybrid":[74],"that":[76,142,155],"electronic":[78],"transducers":[79],"instead":[80],"have":[83,112],"promise.":[84],"oscillometric":[86],"can":[88,157],"used":[90],"office":[92,143],"measurement,":[93],"only":[95],"independently":[97],"validated":[98],"according":[99],"standard":[101],"protocols":[102],"should":[103],"used,":[105],"individual":[107],"calibration":[108],"recommended.":[110],"They":[111],"advantage":[114],"being":[116],"able":[117],"take":[119],"multiple":[120],"measurements.":[121],"Proper":[122],"training":[123],"observers,":[125],"positioning":[126],"patient,":[129],"selection":[131],"cuff":[133],"size":[134],"all":[136],"essential.":[137],"It":[138],"increasingly":[140],"recognized":[141],"measurements":[144],"correlate":[145],"poorly":[146],"measured":[150],"other":[152],"settings,":[153],"supplemented":[159],"by":[160],"self-measured":[161],"readings":[162],"taken":[163]},"counts_by_year":[],"updated_date":"2026-10-14T16:39:01.820549","created_date":"2025-10-27T00:00:00"}
