{"id":"https://openalex.org/W7089340335","doi":"https://doi.org/10.1016/j.engstruct.2025.121517","title":"Seismic strengthening of external beam-column joints with plain bars using minimally invasive FRP layouts","display_name":"Seismic strengthening of external beam-column joints with plain bars using minimally invasive FRP layouts","publication_year":2025,"publication_date":"2025-10-13","ids":{"openalex":"https://openalex.org/W7089340335","doi":"https://doi.org/10.1016/j.engstruct.2025.121517"},"language":"en","primary_location":{"id":"doi:10.1016/j.engstruct.2025.121517","doi":"https://doi.org/10.1016/j.engstruct.2025.121517","is_oa":true,"landing_page_url":"https://doi.org/10.1016/j.engstruct.2025.121517","pdf_url":null,"source":{"id":"https://openalex.org/S165454098","display_name":"Engineering Structures","issn_l":"0141-0296","issn":["0141-0296","1873-7323"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["anvur-scientific","cwts-core","dongbi-b","jufo-3","ki-jl-2","norway-2","poland-140","russia-white-list-1","vabb-shw"],"host_organization":"https://openalex.org/P4310320990","host_organization_name":"Elsevier BV","host_organization_lineage":["https://openalex.org/P4310320990"],"host_organization_lineage_names":["Elsevier BV"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Engineering Structures","raw_type":"journal-article"},"volume":null,"type":"article","indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"hybrid","oa_url":"https://doi.org/10.1016/j.engstruct.2025.121517","any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5081486797","display_name":"Martha A. Karabini","orcid":"https://orcid.org/0000-0001-6111-1378","observed_orcids":["https://orcid.org/0000-0001-6111-1378"]},"institutions":[{"id":"https://openalex.org/I147962203","display_name":"Democritus University of Thrace","ror":"https://ror.org/03bfqnx40","country_code":"GR","type":"education","lineage":["https://openalex.org/I147962203"]}],"countries":["GR"],"is_corresponding":true,"raw_author_name":"Martha Karabini","raw_affiliation_strings":["Lab. of Reinforced Concrete and Seismic Design of Structures, Dept. of Civil Engineering, Democritus University of Thrace, Xanthi 67100, Greece"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Lab. of Reinforced Concrete and Seismic Design of Structures, Dept. of Civil Engineering, Democritus University of Thrace, Xanthi 67100, Greece","institution_ids":["https://openalex.org/I147962203"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5044549315","display_name":"Ciro Del Vecchio","orcid":"https://orcid.org/0000-0002-4912-2944","observed_orcids":["https://orcid.org/0000-0002-4912-2944"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Ciro Del Vecchio","raw_affiliation_strings":[],"raw_orcid":"https://orcid.org/0000-0002-4912-2944","affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5002418101","display_name":"Theodoros C. Rousakis","orcid":"https://orcid.org/0000-0002-6384-1451","observed_orcids":["https://orcid.org/0000-0002-6384-1451"]},"institutions":[{"id":"https://openalex.org/I147962203","display_name":"Democritus University of Thrace","ror":"https://ror.org/03bfqnx40","country_code":"GR","type":"education","lineage":["https://openalex.org/I147962203"]}],"countries":["GR"],"is_corresponding":false,"raw_author_name":"Theodoros Rousakis","raw_affiliation_strings":["Lab. of Reinforced Concrete and Seismic Design of Structures, Dept. of Civil Engineering, Democritus University of Thrace, Xanthi 67100, Greece"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Lab. of Reinforced Concrete and Seismic Design of Structures, Dept. of Civil Engineering, Democritus University of Thrace, Xanthi 67100, Greece","institution_ids":["https://openalex.org/I147962203"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5017737982","display_name":"Marco Di Ludovico","orcid":"https://orcid.org/0000-0003-3697-3923","observed_orcids":["https://orcid.org/0000-0003-3697-3923"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Marco Di Ludovico","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"last","author":{"id":null,"display_name":"Andrea Prota","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I71267560","display_name":"University of Naples Federico II","ror":"https://ror.org/05290cv24","country_code":"IT","type":"education","lineage":["https://openalex.org/I71267560"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Andrea Prota","raw_affiliation_strings":["Dept. of Structures for Engineering and Architecture, University of Napoli Federico II, via Claudio 21, Napoli 80125, Italy"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Dept. of Structures for Engineering and Architecture, University of Napoli Federico II, via Claudio 21, Napoli 80125, Italy","institution_ids":["https://openalex.org/I71267560"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":2,"corresponding_author_ids":["https://openalex.org/A5081486797"],"corresponding_institution_ids":["https://openalex.org/I147962203"],"apc_list":{"value":4620,"currency":"USD","value_usd":4620},"apc_paid":{"value":4620,"currency":"USD","value_usd":4620},"fwci":1.7139,"has_fulltext":false,"cited_by_count":4,"citation_normalized_percentile":{"value":0.84158358,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":98,"max":99},"biblio":{"volume":"345","issue":null,"first_page":"121517","last_page":"121517"},"is_retracted":false,"is_paratext":false,"is_xpac":true,"primary_topic":{"id":"https://openalex.org/T10479","display_name":"Structural Behavior of Reinforced Concrete","score":0.899399995803833,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10479","display_name":"Structural Behavior of Reinforced Concrete","score":0.899399995803833,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10160","display_name":"Seismic Performance and Analysis","score":0.08169999718666077,"subfield":{"id":"https://openalex.org/subfields/2205","display_name":"Civil and Structural Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11352","display_name":"Masonry and Concrete Structural Analysis","score":0.016899999231100082,"subfield":{"id":"https://openalex.org/subfields/2205","display_name":"Civil and Structural Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/seismic-retrofitting","display_name":"seismic retrofitting","score":0.8140000104904175},{"id":"https://openalex.org/keywords/beam-column-joints","display_name":"beam-column joints","score":0.9789999723434448},{"id":"https://openalex.org/keywords/externally-bonded-frp","display_name":"externally bonded FRP","score":0.8479999899864197},{"id":"https://openalex.org/keywords/plain-steel-bars","display_name":"plain steel bars","score":0.6010000109672546},{"id":"https://openalex.org/keywords/reinforced-concrete-structures","display_name":"reinforced concrete structures","score":0.7710000276565552},{"id":"https://openalex.org/keywords/transverse-reinforcement","display_name":"transverse reinforcement","score":0.671999990940094},{"id":"https://openalex.org/keywords/bond-degradation","display_name":"bond degradation","score":0.8199999928474426},{"id":"https://openalex.org/keywords/energy-dissipation","display_name":"energy dissipation","score":0.984000027179718},{"id":"https://openalex.org/keywords/capacity-model","display_name":"capacity model","score":0.8140000104904175},{"id":"https://openalex.org/keywords/seismic-detailing","display_name":"seismic detailing","score":0.5600000023841858},{"id":"https://openalex.org/keywords/old-buildings","display_name":"old buildings","score":0.3610000014305115}],"concepts":[{"id":"https://openalex.org/C76344452","wikidata":"https://www.wikidata.org/wiki/Q263125","display_name":"Fibre-reinforced plastic","level":2,"score":0.7906000018119812},{"id":"https://openalex.org/C66938386","wikidata":"https://www.wikidata.org/wiki/Q633538","display_name":"Structural engineering","level":1,"score":0.6869999766349792},{"id":"https://openalex.org/C136478896","wikidata":"https://www.wikidata.org/wiki/Q898288","display_name":"Brittleness","level":2,"score":0.6531999707221985},{"id":"https://openalex.org/C188198153","wikidata":"https://www.wikidata.org/wiki/Q1613840","display_name":"Limiting","level":2,"score":0.5719000101089478},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.5491999983787537},{"id":"https://openalex.org/C95713431","wikidata":"https://www.wikidata.org/wiki/Q631425","display_name":"Vulnerability (computing)","level":2,"score":0.5020999908447266},{"id":"https://openalex.org/C187320778","wikidata":"https://www.wikidata.org/wiki/Q1349130","display_name":"Geotechnical engineering","level":1,"score":0.41850000619888306},{"id":"https://openalex.org/C96035792","wikidata":"https://www.wikidata.org/wiki/Q43606218","display_name":"Shear (geology)","level":2,"score":0.3720000088214874},{"id":"https://openalex.org/C167063184","wikidata":"https://www.wikidata.org/wiki/Q1400839","display_name":"Vulnerability assessment","level":3,"score":0.3720000088214874},{"id":"https://openalex.org/C29979489","wikidata":"https://www.wikidata.org/wiki/Q2468944","display_name":"Seismic retrofit","level":3,"score":0.36719998717308044},{"id":"https://openalex.org/C18555067","wikidata":"https://www.wikidata.org/wiki/Q8375051","display_name":"Joint (building)","level":2,"score":0.3652999997138977},{"id":"https://openalex.org/C2988805333","wikidata":"https://www.wikidata.org/wiki/Q184190","display_name":"Reinforced concrete","level":2,"score":0.3513000011444092},{"id":"https://openalex.org/C182358397","wikidata":"https://www.wikidata.org/wiki/Q2656128","display_name":"Seismic analysis","level":2,"score":0.33899998664855957},{"id":"https://openalex.org/C127893833","wikidata":"https://www.wikidata.org/wiki/Q7492185","display_name":"Shear strength (soil)","level":3,"score":0.32519999146461487},{"id":"https://openalex.org/C77595967","wikidata":"https://www.wikidata.org/wiki/Q3151013","display_name":"Forensic engineering","level":1,"score":0.3199000060558319},{"id":"https://openalex.org/C123060433","wikidata":"https://www.wikidata.org/wiki/Q2026731","display_name":"Seismic loading","level":2,"score":0.3165999948978424},{"id":"https://openalex.org/C2779372316","wikidata":"https://www.wikidata.org/wiki/Q569057","display_name":"Stiffness","level":2,"score":0.3075999915599823},{"id":"https://openalex.org/C127313418","wikidata":"https://www.wikidata.org/wiki/Q1069","display_name":"Geology","level":0,"score":0.30399999022483826},{"id":"https://openalex.org/C134512083","wikidata":"https://www.wikidata.org/wiki/Q1632256","display_name":"Seismic risk","level":2,"score":0.2992999851703644},{"id":"https://openalex.org/C147176958","wikidata":"https://www.wikidata.org/wiki/Q77590","display_name":"Civil engineering","level":1,"score":0.2989000082015991},{"id":"https://openalex.org/C135628077","wikidata":"https://www.wikidata.org/wiki/Q220184","display_name":"Finite element method","level":2,"score":0.2921999990940094},{"id":"https://openalex.org/C162307627","wikidata":"https://www.wikidata.org/wiki/Q204833","display_name":"Enhanced Data Rates for GSM Evolution","level":2,"score":0.2639999985694885}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1016/j.engstruct.2025.121517","doi":"https://doi.org/10.1016/j.engstruct.2025.121517","is_oa":true,"landing_page_url":"https://doi.org/10.1016/j.engstruct.2025.121517","pdf_url":null,"source":{"id":"https://openalex.org/S165454098","display_name":"Engineering Structures","issn_l":"0141-0296","issn":["0141-0296","1873-7323"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["anvur-scientific","cwts-core","dongbi-b","jufo-3","ki-jl-2","norway-2","poland-140","russia-white-list-1","vabb-shw"],"host_organization":"https://openalex.org/P4310320990","host_organization_name":"Elsevier BV","host_organization_lineage":["https://openalex.org/P4310320990"],"host_organization_lineage_names":["Elsevier BV"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Engineering Structures","raw_type":"journal-article"}],"best_oa_location":{"id":"doi:10.1016/j.engstruct.2025.121517","doi":"https://doi.org/10.1016/j.engstruct.2025.121517","is_oa":true,"landing_page_url":"https://doi.org/10.1016/j.engstruct.2025.121517","pdf_url":null,"source":{"id":"https://openalex.org/S165454098","display_name":"Engineering Structures","issn_l":"0141-0296","issn":["0141-0296","1873-7323"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["anvur-scientific","cwts-core","dongbi-b","jufo-3","ki-jl-2","norway-2","poland-140","russia-white-list-1","vabb-shw"],"host_organization":"https://openalex.org/P4310320990","host_organization_name":"Elsevier BV","host_organization_lineage":["https://openalex.org/P4310320990"],"host_organization_lineage_names":["Elsevier BV"],"type":"journal"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Engineering Structures","raw_type":"journal-article"},"sustainable_development_goals":[{"score":0.7207000255584717,"id":"https://metadata.un.org/sdg/9","display_name":"Industry, innovation and infrastructure"}],"sustainable_development_goals_aurora":[{"score":0.65565425157547,"id":"https://metadata.un.org/sdg/11","display_name":"Sustainable cities and communities"}],"study_designs":[],"awards":[],"funders":[{"id":"https://openalex.org/F4320313804","display_name":"Dipartimento della Protezione Civile, Presidenza del Consiglio dei Ministri","ror":"https://ror.org/050xp5d36"}],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":25,"referenced_works":["https://openalex.org/W1978735047","https://openalex.org/W1980271253","https://openalex.org/W1996104401","https://openalex.org/W2006040434","https://openalex.org/W2015212359","https://openalex.org/W2023496582","https://openalex.org/W2031485154","https://openalex.org/W2083424497","https://openalex.org/W2149460830","https://openalex.org/W2164763866","https://openalex.org/W2179419111","https://openalex.org/W2268300328","https://openalex.org/W2290776346","https://openalex.org/W2567238741","https://openalex.org/W2589159325","https://openalex.org/W2898327040","https://openalex.org/W2943318913","https://openalex.org/W2950410233","https://openalex.org/W3015897552","https://openalex.org/W3093562379","https://openalex.org/W3198513089","https://openalex.org/W4247113360","https://openalex.org/W4285392852","https://openalex.org/W4361199414","https://openalex.org/W4398247148"],"related_works":[],"abstract_inverted_index":{"Recent":[0],"seismic":[1,8,39,92,110],"events":[2],"have":[3,126],"underscored":[4],"the":[5,14,28,33,58,81,90,99,107,135,154,158,165,172],"role":[6],"of":[7,17,36,60,83,94,98,109,137,150,174],"detailing":[9],"in":[10,79,153,163],"earthquake-prone":[11],"regions,":[12],"emphasizing":[13],"high":[15],"vulnerability":[16],"existing":[18],"reinforced":[19],"concrete":[20],"(RC)":[21],"structures.":[22],"Beam-column":[23],"joints":[24],"(BCJs)":[25],"are":[26,76,161],"among":[27],"most":[29],"critical":[30],"members":[31],"influencing":[32],"overall":[34,91],"response":[35],"buildings":[37,152],"during":[38],"events.":[40],"BCJs":[41,143],"designed":[42],"under":[43],"obsolete":[44],"regulations":[45],"often":[46],"lack":[47],"adequate":[48],"transverse":[49],"reinforcement,":[50],"making":[51],"them":[52],"susceptible":[53],"to":[54,170,184],"brittle":[55,183],"failure,":[56,87,186],"while":[57],"use":[59],"plain":[61,145],"bars":[62,148],"is":[63,198],"associated":[64],"with":[65,144,194],"bond":[66],"degradation":[67],"and":[68,133,167,187],"lower":[69],"steel":[70,147],"yield":[71],"stress.":[72],"Externally":[73],"bonded":[74],"FRPs":[75],"proven":[77],"effective":[78],"enhancing":[80],"strength":[82],"BCJs,":[84],"preventing":[85],"shear":[86],"thereby":[88],"reducing":[89],"risk":[93,111],"buildings.":[95],"However,":[96],"many":[97],"proposed":[100],"strengthening":[101,124],"layouts":[102,125],"disrupt":[103],"building":[104],"usability,":[105],"limiting":[106],"effectiveness":[108],"mitigation":[112],"at":[113],"a":[114,180],"regional":[115],"scale.":[116],"To":[117],"address":[118],"this,":[119],"FRP-based":[120],"minimally":[121],"invasive":[122],"(MinInv)":[123],"been":[127],"recently":[128],"proposed.":[129,199],"This":[130],"study":[131],"reports":[132],"discusses":[134],"results":[136],"an":[138],"experimental":[139],"program":[140],"on":[141],"four":[142],"internal":[146],"typical":[149],"RC":[151],"Mediterranean":[155],"built":[156],"before":[157],"70\u2019s.":[159],"They":[160],"tested":[162],"both":[164],"as-built":[166],"FRP-strengthened":[168],"configuration,":[169],"validate":[171],"performance":[173],"MinInv-layouts.":[175],"Results":[176],"demonstrated":[177],"improved":[178],"strength,":[179],"shift":[181],"from":[182],"ductile":[185],"significantly":[188],"increased":[189],"energy":[190],"dissipation.":[191],"A":[192],"comparison":[193],"available":[195],"capacity":[196],"models":[197]},"counts_by_year":[{"year":2026,"cited_by_count":4}],"updated_date":"2026-10-14T16:39:01.820549","created_date":"2025-10-13T00:00:00"}
