{"id":"https://openalex.org/W7054814217","doi":null,"title":"Bias in medical biochemistry- what laboratory professionals need to know?","display_name":"Bias in medical biochemistry- what laboratory professionals need to know?","publication_year":2021,"publication_date":"2021-01-01","ids":{"openalex":"https://openalex.org/W7054814217"},"language":"en","primary_location":{"id":"pmh:oai:farfar.pharmacy.bg.ac.rs:123456789/4076","doi":null,"is_oa":true,"landing_page_url":"https://farfar.pharmacy.bg.ac.rs/handle/123456789/4076","pdf_url":null,"source":{"id":"https://openalex.org/S4306402647","display_name":"FarFar (University of Belgrade, Faculty of Chemistry (Belgrade, Serbia))","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I4210101313","host_organization_name":"University Hospital Center Dr Dragi\u0161a Mi\u0161ovi\u0107","host_organization_lineage":["https://openalex.org/I4210101313"],"host_organization_lineage_names":[],"type":"repository"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"XVII me\u0111unarodna konvencija o kvalitetu - Zbornik radova JUSK ICQ 2021, 9-11 jun Beograd","raw_type":"conferenceObject"},"volume":null,"type":"article","is_traditional":true,"indexed_in":[],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"https://farfar.pharmacy.bg.ac.rs/handle/123456789/4076","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5003460835","display_name":"Neda Milinkovi\u0107","orcid":"https://orcid.org/0000-0002-2641-9817","observed_orcids":["https://orcid.org/0000-0002-2641-9817"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Milinkovi\u0107, Neda","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"last","author":{"id":null,"display_name":"Ignjatovi\u0107, Svetlana","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Ignjatovi\u0107, Svetlana","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.4928865,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":true,"primary_topic":{"id":"https://openalex.org/T11314","display_name":"Clinical Laboratory Practices and Quality Control","score":0.9707000255584717,"subfield":{"id":"https://openalex.org/subfields/3607","display_name":"Medical Laboratory Technology"},"field":{"id":"https://openalex.org/fields/36","display_name":"Health Professions"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},"topics":[{"id":"https://openalex.org/T11314","display_name":"Clinical Laboratory Practices and Quality Control","score":0.9707000255584717,"subfield":{"id":"https://openalex.org/subfields/3607","display_name":"Medical Laboratory Technology"},"field":{"id":"https://openalex.org/fields/36","display_name":"Health Professions"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T11890","display_name":"Scientific Measurement and Uncertainty Evaluation","score":0.029200000688433647,"subfield":{"id":"https://openalex.org/subfields/3105","display_name":"Instrumentation"},"field":{"id":"https://openalex.org/fields/31","display_name":"Physics and Astronomy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13309","display_name":"Reliability and Agreement in Measurement","score":0.0,"subfield":{"id":"https://openalex.org/subfields/1804","display_name":"Statistics, Probability and Uncertainty"},"field":{"id":"https://openalex.org/fields/18","display_name":"Decision Sciences"},"domain":{"id":"https://openalex.org/domains/2","display_name":"Social Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/measurement-bias","display_name":"measurement bias","score":0.8130000233650208},{"id":"https://openalex.org/keywords/trueness","display_name":"trueness","score":0.8199999928474426},{"id":"https://openalex.org/keywords/systematic-errors","display_name":"systematic errors","score":0.7960000038146973},{"id":"https://openalex.org/keywords/medical-biochemistry","display_name":"medical biochemistry","score":0.6269999742507935},{"id":"https://openalex.org/keywords/reference-materials","display_name":"reference materials","score":0.8320000171661377},{"id":"https://openalex.org/keywords/certified-reference-materials","display_name":"certified reference materials","score":0.9459999799728394},{"id":"https://openalex.org/keywords/measurement-uncertainty","display_name":"measurement uncertainty","score":0.7080000042915344},{"id":"https://openalex.org/keywords/method-comparison","display_name":"method comparison","score":0.4699999988079071},{"id":"https://openalex.org/keywords/laboratory-quality-management","display_name":"laboratory quality management","score":0.6690000295639038},{"id":"https://openalex.org/keywords/external-quality-assessment","display_name":"external quality assessment","score":0.6620000004768372}],"concepts":[{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4846999943256378},{"id":"https://openalex.org/C2779530757","wikidata":"https://www.wikidata.org/wiki/Q1207505","display_name":"Quality (philosophy)","level":2,"score":0.48159998655319214},{"id":"https://openalex.org/C112930515","wikidata":"https://www.wikidata.org/wiki/Q4389547","display_name":"Risk analysis (engineering)","level":1,"score":0.4228000044822693},{"id":"https://openalex.org/C159447121","wikidata":"https://www.wikidata.org/wiki/Q490535","display_name":"Response bias","level":2,"score":0.3864000141620636},{"id":"https://openalex.org/C106436119","wikidata":"https://www.wikidata.org/wiki/Q836575","display_name":"Quality assurance","level":3,"score":0.36739999055862427},{"id":"https://openalex.org/C19527891","wikidata":"https://www.wikidata.org/wiki/Q1120908","display_name":"Medical physics","level":1,"score":0.34880000352859497},{"id":"https://openalex.org/C44519122","wikidata":"https://www.wikidata.org/wiki/Q2296168","display_name":"Medical laboratory","level":2,"score":0.3359000086784363},{"id":"https://openalex.org/C137209882","wikidata":"https://www.wikidata.org/wiki/Q1403517","display_name":"Measurement uncertainty","level":2,"score":0.3334999978542328},{"id":"https://openalex.org/C2985213535","wikidata":"https://www.wikidata.org/wiki/Q1626599","display_name":"Reference values","level":2,"score":0.2727999985218048},{"id":"https://openalex.org/C88629717","wikidata":"https://www.wikidata.org/wiki/Q17056323","display_name":"Information bias","level":3,"score":0.2676999866962433},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.2615000009536743},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.25999999046325684},{"id":"https://openalex.org/C100253034","wikidata":"https://www.wikidata.org/wiki/Q196372","display_name":"Systematic error","level":2,"score":0.2531999945640564}],"mesh":[],"locations_count":1,"locations":[{"id":"pmh:oai:farfar.pharmacy.bg.ac.rs:123456789/4076","doi":null,"is_oa":true,"landing_page_url":"https://farfar.pharmacy.bg.ac.rs/handle/123456789/4076","pdf_url":null,"source":{"id":"https://openalex.org/S4306402647","display_name":"FarFar (University of Belgrade, Faculty of Chemistry (Belgrade, Serbia))","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I4210101313","host_organization_name":"University Hospital Center Dr Dragi\u0161a Mi\u0161ovi\u0107","host_organization_lineage":["https://openalex.org/I4210101313"],"host_organization_lineage_names":[],"type":"repository"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"XVII me\u0111unarodna konvencija o kvalitetu - Zbornik radova JUSK ICQ 2021, 9-11 jun Beograd","raw_type":"conferenceObject"}],"best_oa_location":{"id":"pmh:oai:farfar.pharmacy.bg.ac.rs:123456789/4076","doi":null,"is_oa":true,"landing_page_url":"https://farfar.pharmacy.bg.ac.rs/handle/123456789/4076","pdf_url":null,"source":{"id":"https://openalex.org/S4306402647","display_name":"FarFar (University of Belgrade, Faculty of Chemistry (Belgrade, Serbia))","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I4210101313","host_organization_name":"University Hospital Center Dr Dragi\u0161a Mi\u0161ovi\u0107","host_organization_lineage":["https://openalex.org/I4210101313"],"host_organization_lineage_names":[],"type":"repository"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"XVII me\u0111unarodna konvencija o kvalitetu - Zbornik radova JUSK ICQ 2021, 9-11 jun Beograd","raw_type":"conferenceObject"},"sustainable_development_goals":[],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W2077039884","https://openalex.org/W2401230896","https://openalex.org/W4410198487","https://openalex.org/W4386406877","https://openalex.org/W2037120565","https://openalex.org/W2354864968","https://openalex.org/W2593900320","https://openalex.org/W2052100313","https://openalex.org/W2888181600","https://openalex.org/W2366446564"],"abstract_inverted_index":{"In":[0,114],"medical":[1,62],"laboratories,":[2],"bias":[3,18,38,59,138,169],"presents":[4],"quantitative":[5],"expression":[6],"of":[7,24,27,67,120],"trueness,":[8],"as":[9,162],"\\nanalytical":[10],"performance":[11],"characteristic":[12],"that":[13,48,76,90,156],"describes":[14],"systematic":[15],"errors.":[16],"Despite":[17],"evaluation":[19],"\\nis":[20],"an":[21],"integral":[22],"part":[23],"basic":[25],"lessons":[26],"laboratory":[28,42,141,160],"quality":[29,112],"management,":[30],"it":[31,73],"is":[32,64,74,125],"still":[33],"difficult":[34],"to":[35,52,167],"achieve":[36],"\\nadequate":[37],"estimation":[39],"in":[40,60,85,139],"routine":[41,61,140],"practice.":[43],"There":[44],"are":[45,84,153],"several":[46],"principles":[47],"could":[49,101],"\\nbe":[50],"used":[51],"estimate":[53],"bias,":[54],"but":[55],"fundamental":[56],"for":[57,128,158],"evaluating":[58],"laboratories":[63],"\\nthe":[65],"availability":[66],"a":[68,86,126],"suitable":[69],"reference":[70,123,144,149],"materials.":[71,150],"Besides,":[72],"important":[75],"the":[77,106,118,121,130,159,163,178],"measuring":[78,81],"\\nmethod":[79],"and":[80,89,147,173],"analytical":[82],"system":[83],"stable":[87],"state,":[88],"they":[91],"have":[92],"completed":[93],"\\nan":[94],"appropriate":[95],"validation":[96],"or":[97],"verification":[98],"process.":[99],"This":[100],"be":[102],"checked":[103],"routinely":[104],"by":[105],"results":[107],"\\nof":[108],"internal":[109],"and/or":[110,177],"external":[111],"control.":[113],"addition,":[115],"information":[116],"about":[117],"uncertainty":[119],"\\ncertified":[122],"material":[124],"prerequisite":[127],"testing":[129],"bias.":[131],"Significant":[132],"efforts":[133],"were":[134],"made":[135],"\\nto":[136],"minimized":[137],"practice,":[142],"using":[143],"measurement":[145,171],"methods":[146,172],"\\ncommutable":[148],"Still,":[151],"there":[152],"some":[154],"challenges":[155],"remain":[157],"\\nprofessionals":[161],"end":[164],"users,":[165],"due":[166],"remaining":[168],"between":[170],"\\nsystems":[174],"from":[175],"different":[176],"same":[179],"manufacturers.":[180]},"counts_by_year":[],"updated_date":"2026-11-04T10:54:05.112534","created_date":"2025-10-10T00:00:00"}
