{"id":"https://openalex.org/W7037385697","doi":null,"title":"Design Considerations of Medium-Frequency Power Transformers in HVDC Applications","display_name":"Design Considerations of Medium-Frequency Power Transformers in HVDC Applications","alternate_titles":[],"publication_year":2017,"publication_date":"2017-01-01","ids":{"openalex":"https://openalex.org/W7037385697"},"language":"en","primary_location":{"id":"pmh:oai:publications.lib.chalmers.se:248952","doi":null,"is_oa":false,"landing_page_url":"http://publications.lib.chalmers.se/publication/248952-design-considerations-of-medium-frequency-power-transformers-in-hvdc-applications","pdf_url":null,"source":{"id":"https://openalex.org/S4377196470","display_name":"Chalmers Publication Library (Chalmers University of Technology)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I66862912","host_organization_name":"Chalmers University of Technology","host_organization_lineage":["https://openalex.org/I66862912"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"","raw_type":"Text.Article.Conference.PeerReviewed"},"parent_works":[],"lineage":["https://openalex.org/W7037385697"],"child_works_count":0,"type":"article","is_traditional":true,"indexed_in":[],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5048726433","display_name":"M. A. Bahmani","orcid":"https://orcid.org/0000-0002-3772-7284","observed_orcids":["https://orcid.org/0000-0002-3772-7284"]},"institutions":[],"countries":[],"is_corresponding":true,"contributor_roles":[],"raw_author_name":"Bahmani, Mohammad Amin","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":["https://openalex.org/A5048726433"],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0968,"has_fulltext":false,"cited_by_count":1,"citation_normalized_percentile":{"value":0.37989364,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":87,"max":92},"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":true,"primary_topic":{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":0.9955999851226807,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":0.9955999851226807,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11102","display_name":"HVDC Systems and Fault Protection","score":0.0015999999595806003,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11249","display_name":"Wireless Power Transfer Systems","score":0.00039999998989515007,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/hvdc","display_name":"HVDC","score":0.8029999732971191},{"id":"https://openalex.org/keywords/isolated-dc-dc-converter","display_name":"isolated DC-DC converter","score":0.8399999737739563},{"id":"https://openalex.org/keywords/transformer-design-optimization","display_name":"transformer design optimization","score":0.7940000295639038},{"id":"https://openalex.org/keywords/high-frequency-magnetic-loss","display_name":"high-frequency magnetic loss","score":0.9290000200271606},{"id":"https://openalex.org/keywords/thermal-management","display_name":"thermal management","score":0.984000027179718},{"id":"https://openalex.org/keywords/power-density","display_name":"power density","score":0.8610000014305115},{"id":"https://openalex.org/keywords/solid-state-transformer","display_name":"solid-state transformer","score":0.7850000262260437},{"id":"https://openalex.org/keywords/offshore-wind-farms","display_name":"offshore wind farms","score":0.871999979019165},{"id":"https://openalex.org/keywords/dc-grid-interconnection","display_name":"DC grid interconnection","score":0.9599999785423279}],"concepts":[{"id":"https://openalex.org/C66322947","wikidata":"https://www.wikidata.org/wiki/Q11658","display_name":"Transformer","level":3,"score":0.6622999906539917},{"id":"https://openalex.org/C2778422915","wikidata":"https://www.wikidata.org/wiki/Q10302051","display_name":"Converters","level":3,"score":0.5909000039100647},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.5268999934196472},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.5083000063896179},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.37229999899864197},{"id":"https://openalex.org/C180850520","wikidata":"https://www.wikidata.org/wiki/Q2166404","display_name":"Isolation transformer","level":4,"score":0.36899998784065247},{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.35989999771118164},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.3587999939918518},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.3499000072479248},{"id":"https://openalex.org/C9121194","wikidata":"https://www.wikidata.org/wiki/Q5377050","display_name":"Energy efficient transformer","level":5,"score":0.3352000117301941},{"id":"https://openalex.org/C8735168","wikidata":"https://www.wikidata.org/wiki/Q61637704","display_name":"Offshore wind power","level":3,"score":0.3327000141143799},{"id":"https://openalex.org/C117323899","wikidata":"https://www.wikidata.org/wiki/Q1907989","display_name":"Distribution transformer","level":4,"score":0.3222000002861023},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.3125999867916107},{"id":"https://openalex.org/C2777767291","wikidata":"https://www.wikidata.org/wiki/Q1080291","display_name":"Sizing","level":2,"score":0.29760000109672546},{"id":"https://openalex.org/C2780705257","wikidata":"https://www.wikidata.org/wiki/Q5636221","display_name":"HVDC converter","level":4,"score":0.289900004863739},{"id":"https://openalex.org/C78600449","wikidata":"https://www.wikidata.org/wiki/Q43302","display_name":"Wind power","level":2,"score":0.2831999957561493},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.28029999136924744},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.2777999937534332},{"id":"https://openalex.org/C88182573","wikidata":"https://www.wikidata.org/wiki/Q1139740","display_name":"High voltage","level":3,"score":0.2718000113964081},{"id":"https://openalex.org/C133770746","wikidata":"https://www.wikidata.org/wiki/Q856535","display_name":"Current transformer","level":4,"score":0.2619999945163727},{"id":"https://openalex.org/C54089160","wikidata":"https://www.wikidata.org/wiki/Q1803786","display_name":"Power engineering","level":4,"score":0.26089999079704285},{"id":"https://openalex.org/C2781163877","wikidata":"https://www.wikidata.org/wiki/Q370607","display_name":"High-voltage direct current","level":4,"score":0.2522999942302704}],"mesh":[],"locations_count":1,"locations":[{"id":"pmh:oai:publications.lib.chalmers.se:248952","doi":null,"is_oa":false,"landing_page_url":"http://publications.lib.chalmers.se/publication/248952-design-considerations-of-medium-frequency-power-transformers-in-hvdc-applications","pdf_url":null,"source":{"id":"https://openalex.org/S4377196470","display_name":"Chalmers Publication Library (Chalmers University of Technology)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I66862912","host_organization_name":"Chalmers University of Technology","host_organization_lineage":["https://openalex.org/I66862912"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"","raw_type":"Text.Article.Conference.PeerReviewed"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","score":0.9853000044822693,"display_name":"Affordable and clean energy"},{"id":"https://metadata.un.org/sdg/9","score":0.8970999717712402,"display_name":"Industry, innovation and infrastructure"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W2468345249","https://openalex.org/W7042561902","https://openalex.org/W7064859711","https://openalex.org/W2984934147","https://openalex.org/W3015276165","https://openalex.org/W2058488154","https://openalex.org/W6948149672","https://openalex.org/W2065388820","https://openalex.org/W4392216939","https://openalex.org/W6945920126"],"abstract_inverted_index":{"High-power":[0],"isolated":[1],"DC-DC":[2],"converters":[3],"are":[4],"likely":[5],"to":[6,53],"provide":[7],"solutions":[8],"for":[9],"many":[10],"technical":[11],"challenges":[12],"associated":[13],"with":[14],"power":[15,40],"density,":[16],"efficiency":[17],"and":[18,32,75,87],"reliability":[19],"in":[20,33],"potential":[21],"applications":[22],"such":[23,50],"as":[24,60,62],"offshore":[25],"wind":[26],"farms,":[27],"inter-connection":[28],"of":[29,45,49,70,78],"DC":[30],"grids":[31],"future":[34],"solid-state":[35],"transformer":[36,41],"applications.":[37],"The":[38],"medium-frequency":[39],"(MFPT)":[42],"is":[43],"one":[44],"the":[46,55,71,83],"key":[47],"elements":[48],"a":[51],"converter":[52],"realize":[54],"voltage":[56],"adoption,":[57],"isolation":[58],"requirements,":[59],"well":[61],"high-power":[63],"density.":[64],"This":[65],"paper":[66],"presents":[67],"an":[68],"overview":[69],"most":[72],"important":[73],"design":[74],"optimization":[76],"considerations":[77],"MFPTs":[79],"taking":[80],"into":[81],"account":[82],"high-frequency":[84],"magnetic":[85],"losses":[86],"thermal":[88],"management.":[89]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W7037385697","counts_by_year":[{"year":2019,"cited_by_count":1}],"updated_date":"2026-11-16T12:05:36.265796","created_date":"2025-10-10T00:00:00"}
