{"id":"https://openalex.org/W6962641069","doi":"https://doi.org/10.16183/j.cnki.jsjtu.2023.159","title":"Active Disturbance Rejection Control of Current of Direct Drive Wind Turbine in Power Grid Fault","display_name":"Active Disturbance Rejection Control of Current of Direct Drive Wind Turbine in Power Grid Fault","publication_year":2024,"publication_date":"2024-12-01","ids":{"openalex":"https://openalex.org/W6962641069","doi":"https://doi.org/10.16183/j.cnki.jsjtu.2023.159"},"language":"en","primary_location":{"id":"pmh:oai:doaj.org/article:ec76b1aa14a047778ce2005c163cf5ed","doi":"https://doi.org/10.16183/j.cnki.jsjtu.2023.159","is_oa":false,"landing_page_url":"https://doaj.org/article/ec76b1aa14a047778ce2005c163cf5ed","pdf_url":null,"source":{"id":"https://openalex.org/S4306401280","display_name":"DOAJ (DOAJ: Directory of Open Access Journals)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Shanghai Jiaotong Daxue xuebao, Vol 58, Iss 12, Pp 1968-1976 (2024)","raw_type":"article"},"volume":null,"type":"article","indexed_in":["doaj"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":null,"display_name":"WANG Han, WANG Fuwen, ZHOU Dangsheng, SHI Gang, ZHANG Jianwen, CAI Xu","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":true,"raw_author_name":"WANG Han, WANG Fuwen, ZHOU Dangsheng, SHI Gang, ZHANG Jianwen, CAI Xu","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.21303413,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":true,"primary_topic":{"id":"https://openalex.org/T10740","display_name":"Wind Turbine Control Systems","score":0.9961000084877014,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10740","display_name":"Wind Turbine Control Systems","score":0.9961000084877014,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.0019000000320374966,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10573","display_name":"Power Quality and Harmonics","score":0.0005000000237487257,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/active-disturbance-rejection-control","display_name":"active disturbance rejection control","score":0.9909999966621399},{"id":"https://openalex.org/keywords/direct-drive-wind-turbine","display_name":"direct-drive wind turbine","score":0.9369999766349792},{"id":"https://openalex.org/keywords/reactive-power-support","display_name":"reactive power support","score":0.8510000109672546},{"id":"https://openalex.org/keywords/power-grid-faults","display_name":"grid faults","score":0.7409999966621399},{"id":"https://openalex.org/keywords/background-harmonics","display_name":"background harmonics","score":0.7319999933242798},{"id":"https://openalex.org/keywords/transient-response","display_name":"transient response","score":0.671999990940094},{"id":"https://openalex.org/keywords/weak-grid","display_name":"weak grid","score":0.5249999761581421},{"id":"https://openalex.org/keywords/robust-control","display_name":"robust control","score":0.5699999928474426}],"concepts":[{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.6646000146865845},{"id":"https://openalex.org/C108755667","wikidata":"https://www.wikidata.org/wiki/Q1930258","display_name":"AC power","level":3,"score":0.6022999882698059},{"id":"https://openalex.org/C78600449","wikidata":"https://www.wikidata.org/wiki/Q43302","display_name":"Wind power","level":2,"score":0.5957000255584717},{"id":"https://openalex.org/C63479239","wikidata":"https://www.wikidata.org/wiki/Q7353546","display_name":"Robustness (evolution)","level":3,"score":0.5902000069618225},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.5335999727249146},{"id":"https://openalex.org/C2778449969","wikidata":"https://www.wikidata.org/wiki/Q130760","display_name":"Turbine","level":2,"score":0.5221999883651733},{"id":"https://openalex.org/C2780799671","wikidata":"https://www.wikidata.org/wiki/Q17087362","display_name":"Transient (computer programming)","level":2,"score":0.5052000284194946},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.47429999709129333},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.44290000200271606},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.42800000309944153},{"id":"https://openalex.org/C177606310","wikidata":"https://www.wikidata.org/wiki/Q5674297","display_name":"Adaptability","level":2,"score":0.41130000352859497},{"id":"https://openalex.org/C203479927","wikidata":"https://www.wikidata.org/wiki/Q5165939","display_name":"Controller (irrigation)","level":2,"score":0.41110000014305115},{"id":"https://openalex.org/C2778072542","wikidata":"https://www.wikidata.org/wiki/Q4677499","display_name":"Active disturbance rejection control","level":4,"score":0.3910999894142151},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.385699987411499},{"id":"https://openalex.org/C2780685028","wikidata":"https://www.wikidata.org/wiki/Q1096907","display_name":"Grid connection","level":3,"score":0.3531000018119812},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.34779998660087585},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.31439998745918274},{"id":"https://openalex.org/C85761212","wikidata":"https://www.wikidata.org/wiki/Q1974593","display_name":"Transient response","level":2,"score":0.31130000948905945},{"id":"https://openalex.org/C17829176","wikidata":"https://www.wikidata.org/wiki/Q179043","display_name":"Electrical impedance","level":2,"score":0.310699999332428},{"id":"https://openalex.org/C56685638","wikidata":"https://www.wikidata.org/wiki/Q2300474","display_name":"Power control","level":3,"score":0.30790001153945923},{"id":"https://openalex.org/C152745839","wikidata":"https://www.wikidata.org/wiki/Q5438153","display_name":"Fault detection and isolation","level":3,"score":0.30469998717308044},{"id":"https://openalex.org/C31531917","wikidata":"https://www.wikidata.org/wiki/Q915157","display_name":"Robust control","level":3,"score":0.304500013589859},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.2924000024795532},{"id":"https://openalex.org/C119701452","wikidata":"https://www.wikidata.org/wiki/Q5165881","display_name":"Control reconfiguration","level":2,"score":0.2816999852657318},{"id":"https://openalex.org/C2780438294","wikidata":"https://www.wikidata.org/wiki/Q6693052","display_name":"Low voltage ride through","level":4,"score":0.27399998903274536},{"id":"https://openalex.org/C17500928","wikidata":"https://www.wikidata.org/wiki/Q959968","display_name":"Control system","level":2,"score":0.2635999917984009},{"id":"https://openalex.org/C116219307","wikidata":"https://www.wikidata.org/wiki/Q7236625","display_name":"Power system simulation","level":4,"score":0.260699987411499},{"id":"https://openalex.org/C172205157","wikidata":"https://www.wikidata.org/wiki/Q1782962","display_name":"Model predictive control","level":3,"score":0.25690001249313354},{"id":"https://openalex.org/C106131492","wikidata":"https://www.wikidata.org/wiki/Q3072260","display_name":"Filter (signal processing)","level":2,"score":0.250900000333786}],"mesh":[],"locations_count":1,"locations":[{"id":"pmh:oai:doaj.org/article:ec76b1aa14a047778ce2005c163cf5ed","doi":"https://doi.org/10.16183/j.cnki.jsjtu.2023.159","is_oa":false,"landing_page_url":"https://doaj.org/article/ec76b1aa14a047778ce2005c163cf5ed","pdf_url":null,"source":{"id":"https://openalex.org/S4306401280","display_name":"DOAJ (DOAJ: Directory of Open Access Journals)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Shanghai Jiaotong Daxue xuebao, Vol 58, Iss 12, Pp 1968-1976 (2024)","raw_type":"article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy","score":0.9853000044822693},{"id":"https://metadata.un.org/sdg/9","display_name":"Industry, innovation and infrastructure","score":0.5378999710083008}],"sustainable_development_goals_aurora":[{"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy","score":0.8973994255065918}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":[],"abstract_inverted_index":{"The":[0,73,101,129,154],"grid":[1,19,39,88,126,147,150],"connection":[2],"guidelines":[3],"require":[4],"wind":[5,123,135],"turbines":[6,124],"to":[7,10,47,78,106],"have":[8,25],"capability":[9],"quickly":[11,79],"support":[12,58],"reactive":[13,56,111],"power":[14,57,112,146,149],"in":[15,38],"the":[16,26,83,86,97,109,116,122,157],"events":[17],"of":[18,28,85,121,132,156],"faults.":[20],"However,":[21],"traditional":[22],"proportional-integral":[23],"controllers":[24],"problems":[27],"slow":[29],"transient":[30,110],"response":[31,113],"and":[32,41,80,115,119,148],"poor":[33],"adaptability":[34,118],"dealing":[35],"with":[36,68,90,151],"changes":[37],"impedance":[40,127],"serious":[42],"model":[43,131],"disturbances.":[44],"In":[45],"order":[46],"solve":[48],"this":[49,51],"problem,":[50],"paper":[52],"proposes":[53],"an":[54],"improved":[55],"control":[59,117,159],"strategy":[60,160],"which":[61,93],"combines":[62],"linear":[63],"active":[64],"disturbance":[65],"rejection":[66],"control(ADRC)":[67],"least":[69],"error":[70],"squares(LES)":[71],"filters.":[72],"LES":[74],"filter":[75],"is":[76,104,140,161],"used":[77,105],"accurately":[81],"detect":[82],"amplitude":[84],"fault":[87,98],"voltage":[89],"background":[91,152],"harmonics,":[92],"can":[94],"effectively":[95,107],"reduce":[96],"detection":[99],"delay.":[100],"ADRC":[102],"controller":[103],"improve":[108],"speed":[114],"robustness":[120],"under":[125],"disturbance.":[128],"simulation":[130],"direct":[133],"drive":[134],"turbine":[136],"based":[137],"on":[138],"PSCAD/EMTDC":[139],"built":[141],"considering":[142],"two":[143],"scenarios,":[144],"weak":[145],"harmonics.":[153],"effectiveness":[155],"proposed":[158],"verified":[162],"by":[163],"simulation.":[164]},"counts_by_year":[],"updated_date":"2026-10-12T09:40:04.860316","created_date":"2025-10-10T00:00:00"}
