{"id":"https://openalex.org/W6889899373","doi":"https://doi.org/10.30501/jree.2024.436703.1813","title":"Experimental Exploration of Thermal Regulation in Li-ion Batteries Utilizing Liquid-Vapor Phase Transition in Direct Proximity to the Cells, in Combination with other BTMSs","display_name":"Experimental Exploration of Thermal Regulation in Li-ion Batteries Utilizing Liquid-Vapor Phase Transition in Direct Proximity to the Cells, in Combination with other BTMSs","publication_year":2024,"publication_date":"2024-09-01","ids":{"openalex":"https://openalex.org/W6889899373","doi":"https://doi.org/10.30501/jree.2024.436703.1813"},"language":"en","primary_location":{"id":"pmh:oai:doaj.org/article:089dc77c5c0544d08263a097193861bd","doi":"https://doi.org/10.30501/jree.2024.436703.1813","is_oa":false,"landing_page_url":"https://doaj.org/article/089dc77c5c0544d08263a097193861bd","pdf_url":null,"source":{"id":"https://openalex.org/S4306401280","display_name":"DOAJ (DOAJ: Directory of Open Access Journals)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Journal of Renewable Energy and Environment, Vol 11, Iss 4, Pp 28-36 (2024)","raw_type":"article"},"volume":null,"type":"article","indexed_in":["doaj"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":null,"display_name":"Majid Goodarzi","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Majid Goodarzi","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"last","author":{"id":"https://openalex.org/A5000060687","display_name":"Mohammad Ameri","orcid":"https://orcid.org/0000-0001-5368-5443","observed_orcids":["https://orcid.org/0000-0001-5368-5443"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Mohammad Ameri","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.20712947,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":true,"primary_topic":{"id":"https://openalex.org/T10663","display_name":"Advanced Battery Technologies Research","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2203","display_name":"Automotive Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10663","display_name":"Advanced Battery Technologies Research","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2203","display_name":"Automotive Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10018","display_name":"Advancements in Battery Materials","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10998","display_name":"Heat Transfer and Optimization","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/lithium-ion-batteries","display_name":"lithium-ion batteries","score":0.8669999837875366},{"id":"https://openalex.org/keywords/battery-thermal-management","display_name":"battery thermal management","score":0.8199999928474426},{"id":"https://openalex.org/keywords/liquid-gas-phase-transition","display_name":"liquid-gas phase transition","score":0.9039999842643738},{"id":"https://openalex.org/keywords/direct-contact-cooling","display_name":"direct contact cooling","score":0.6859999895095825},{"id":"https://openalex.org/keywords/heat-sinks","display_name":"heat sinks","score":0.5920000076293945},{"id":"https://openalex.org/keywords/hydrogels","display_name":"hydrogels","score":0.6460000276565552},{"id":"https://openalex.org/keywords/natural-convection","display_name":"natural convection","score":0.7170000076293945},{"id":"https://openalex.org/keywords/battery-pack-cooling","display_name":"battery pack cooling","score":0.7310000061988831},{"id":"https://openalex.org/keywords/inlet-water-temperature","display_name":"inlet water temperature","score":0.7080000042915344},{"id":"https://openalex.org/keywords/water-flow-rate","display_name":"water flow rate","score":0.6869999766349792}],"concepts":[{"id":"https://openalex.org/C199499590","wikidata":"https://www.wikidata.org/wiki/Q266790","display_name":"Refrigerant","level":3,"score":0.8292999863624573},{"id":"https://openalex.org/C186937647","wikidata":"https://www.wikidata.org/wiki/Q1796959","display_name":"Heat sink","level":2,"score":0.6697999835014343},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.6302000284194946},{"id":"https://openalex.org/C50517652","wikidata":"https://www.wikidata.org/wiki/Q179635","display_name":"Heat transfer","level":2,"score":0.5702000260353088},{"id":"https://openalex.org/C7694927","wikidata":"https://www.wikidata.org/wiki/Q7667810","display_name":"Water cooling","level":2,"score":0.5665000081062317},{"id":"https://openalex.org/C11026015","wikidata":"https://www.wikidata.org/wiki/Q840551","display_name":"Computer cooling","level":3,"score":0.5583000183105469},{"id":"https://openalex.org/C204530211","wikidata":"https://www.wikidata.org/wiki/Q752823","display_name":"Thermal","level":2,"score":0.5253999829292297},{"id":"https://openalex.org/C156820238","wikidata":"https://www.wikidata.org/wiki/Q422876","display_name":"Active cooling","level":3,"score":0.5177000164985657},{"id":"https://openalex.org/C116067010","wikidata":"https://www.wikidata.org/wiki/Q4698686","display_name":"Airflow","level":2,"score":0.4975000023841858},{"id":"https://openalex.org/C105873366","wikidata":"https://www.wikidata.org/wiki/Q1208873","display_name":"Air cooling","level":2,"score":0.475600004196167},{"id":"https://openalex.org/C2778119658","wikidata":"https://www.wikidata.org/wiki/Q1806889","display_name":"Phase-change material","level":3,"score":0.4641000032424927},{"id":"https://openalex.org/C201289731","wikidata":"https://www.wikidata.org/wiki/Q1172599","display_name":"Inlet","level":2,"score":0.45879998803138733},{"id":"https://openalex.org/C91721477","wikidata":"https://www.wikidata.org/wiki/Q778612","display_name":"Fin","level":2,"score":0.45080000162124634},{"id":"https://openalex.org/C57879066","wikidata":"https://www.wikidata.org/wiki/Q41217","display_name":"Mechanics","level":1,"score":0.4131999909877777},{"id":"https://openalex.org/C29700514","wikidata":"https://www.wikidata.org/wiki/Q634340","display_name":"Heat transfer coefficient","level":3,"score":0.4106000065803528},{"id":"https://openalex.org/C24561367","wikidata":"https://www.wikidata.org/wiki/Q909313","display_name":"Forced convection","level":3,"score":0.40880000591278076},{"id":"https://openalex.org/C97355855","wikidata":"https://www.wikidata.org/wiki/Q11473","display_name":"Thermodynamics","level":1,"score":0.398499995470047},{"id":"https://openalex.org/C172120300","wikidata":"https://www.wikidata.org/wiki/Q1134348","display_name":"Volumetric flow rate","level":2,"score":0.3677000105381012},{"id":"https://openalex.org/C79795727","wikidata":"https://www.wikidata.org/wiki/Q3068508","display_name":"Passive cooling","level":3,"score":0.3310000002384186},{"id":"https://openalex.org/C48632124","wikidata":"https://www.wikidata.org/wiki/Q617088","display_name":"Heat spreader","level":3,"score":0.310699999332428},{"id":"https://openalex.org/C173991790","wikidata":"https://www.wikidata.org/wiki/Q1896787","display_name":"Evaporative cooler","level":2,"score":0.3100999891757965},{"id":"https://openalex.org/C114834414","wikidata":"https://www.wikidata.org/wiki/Q15477170","display_name":"Thermal management of electronic devices and systems","level":2,"score":0.3070000112056732},{"id":"https://openalex.org/C137693562","wikidata":"https://www.wikidata.org/wiki/Q899628","display_name":"Thermal resistance","level":3,"score":0.30480000376701355},{"id":"https://openalex.org/C2776427868","wikidata":"https://www.wikidata.org/wiki/Q671257","display_name":"Forced-air","level":2,"score":0.3041999936103821},{"id":"https://openalex.org/C2779301550","wikidata":"https://www.wikidata.org/wiki/Q217236","display_name":"Working fluid","level":2,"score":0.2978000044822693},{"id":"https://openalex.org/C555008776","wikidata":"https://www.wikidata.org/wiki/Q267298","display_name":"Battery (electricity)","level":3,"score":0.2874000072479248},{"id":"https://openalex.org/C142014798","wikidata":"https://www.wikidata.org/wiki/Q7783037","display_name":"Thermal contact","level":3,"score":0.28540000319480896},{"id":"https://openalex.org/C38349280","wikidata":"https://www.wikidata.org/wiki/Q1434290","display_name":"Flow (mathematics)","level":2,"score":0.2847999930381775},{"id":"https://openalex.org/C2988574769","wikidata":"https://www.wikidata.org/wiki/Q2259545","display_name":"Water flow","level":2,"score":0.28380000591278076},{"id":"https://openalex.org/C135402231","wikidata":"https://www.wikidata.org/wiki/Q898440","display_name":"Dissipation","level":2,"score":0.2809999883174896},{"id":"https://openalex.org/C164915370","wikidata":"https://www.wikidata.org/wiki/Q5167494","display_name":"Cooling capacity","level":2,"score":0.27950000762939453},{"id":"https://openalex.org/C116915560","wikidata":"https://www.wikidata.org/wiki/Q83504","display_name":"Nuclear engineering","level":1,"score":0.2727999985218048},{"id":"https://openalex.org/C75892298","wikidata":"https://www.wikidata.org/wiki/Q1366187","display_name":"Mass flow rate","level":2,"score":0.26840001344680786},{"id":"https://openalex.org/C2993006356","wikidata":"https://www.wikidata.org/wiki/Q7667810","display_name":"Water cooled","level":3,"score":0.25589999556541443},{"id":"https://openalex.org/C2778952998","wikidata":"https://www.wikidata.org/wiki/Q17010280","display_name":"Electronics cooling","level":3,"score":0.25529998540878296},{"id":"https://openalex.org/C536315585","wikidata":"https://www.wikidata.org/wiki/Q7698332","display_name":"Temperature control","level":2,"score":0.25110000371932983},{"id":"https://openalex.org/C49996111","wikidata":"https://www.wikidata.org/wiki/Q2277783","display_name":"Free cooling","level":3,"score":0.25049999356269836},{"id":"https://openalex.org/C2777777821","wikidata":"https://www.wikidata.org/wiki/Q25111513","display_name":"Heat transfer enhancement","level":4,"score":0.2500999867916107}],"mesh":[],"locations_count":1,"locations":[{"id":"pmh:oai:doaj.org/article:089dc77c5c0544d08263a097193861bd","doi":"https://doi.org/10.30501/jree.2024.436703.1813","is_oa":false,"landing_page_url":"https://doaj.org/article/089dc77c5c0544d08263a097193861bd","pdf_url":null,"source":{"id":"https://openalex.org/S4306401280","display_name":"DOAJ (DOAJ: Directory of Open Access Journals)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"Journal of Renewable Energy and Environment, Vol 11, Iss 4, Pp 28-36 (2024)","raw_type":"article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy","score":0.9853000044822693}],"sustainable_development_goals_aurora":[{"id":"https://metadata.un.org/sdg/6","display_name":"Clean water and sanitation","score":0.5458928942680359}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":[],"abstract_inverted_index":{"In":[0,68],"the":[1,6,9,21,26,31,36,53,55,63,66,69,72,76,82,96,98,114,117,120,127,133,136,141,172,182,198,208],"present":[2],"work,":[3],"direct":[4],"contact":[5,30],"refrigerant":[7,27],"and":[8,47,158],"cells":[10],"was":[11,100,148,176],"employed":[12],"for":[13],"thermal":[14],"management.":[15],"This":[16],"study":[17],"experimentally":[18],"investigates":[19],"cooling":[20,49,156],"battery":[22],"pack":[23],"by":[24,60,124,178],"allowing":[25],"to":[28,52,81,181,203],"directly":[29],"cells.":[32],"Furthermore,":[33],"it":[34],"presents":[35],"first":[37],"experimental":[38],"evaluation":[39],"of":[40,65,116,129,135,169],"combining":[41],"this":[42],"approach":[43],"with":[44,102,151],"various":[45,159],"active":[46,103,153],"passive":[48,105],"methods.":[50],"According":[51],"results,":[54],"cells\u2019":[56,121,142,173],"maximum":[57,122,143,174,210],"temperature":[58,123,175,201],"decreased":[59,119],"34\u00b0C":[61],"at":[62],"end":[64],"discharge.":[67],"proposed":[70,146],"system,":[71,157],"heatsink":[73,118,137],"served":[74],"as":[75],"only":[77],"heat":[78,85,93],"transfer":[79,86],"path":[80],"environment,":[83],"where.":[84],"occurred":[87],"via":[88],"free":[89],"convection.":[90],"To":[91],"enhance":[92],"dissipation":[94],"from":[95],"heatsink,":[97],"system":[99,147],"combined":[101,150],"or":[104],"Battery":[106],"Thermal":[107],"Management":[108],"Systems":[109],"(BTMSs).":[110],"Using":[111],"hydrogel":[112],"between":[113,132],"fins":[115,134],"0.5\u00b0C.":[125],"However,":[126],"use":[128],"forced":[130,154,185],"airflow":[131],"did":[138],"not":[139],"affect":[140],"temperature.":[144,211],"The":[145],"also":[149],"an":[152],"liquid":[155],"water":[160,186,191,200],"flow":[161,167],"rates":[162],"were":[163,193],"investigated.":[164],"At":[165],"a":[166,204],"rate":[168],"200":[170],"LPH,":[171],"reduced":[177],"1.5\u00b0C":[179],"compared":[180],"mode":[183],"without":[184],"flow.":[187],"Additionally,":[188],"different":[189],"inlet":[190,199],"temperatures":[192],"examined,":[194],"revealing":[195],"that":[196],"increasing":[197],"leads":[202],"significant":[205],"rise":[206],"in":[207],"cells'":[209]},"counts_by_year":[],"updated_date":"2026-10-12T09:40:04.860316","created_date":"2025-10-10T00:00:00"}
