{"id":"https://openalex.org/W67949595","doi":"https://doi.org/10.21236/ada520818","title":"Energy Optimization Assessments at U.S. Army Installations: Caserma Ederle Vicenza, Italy","display_name":"Energy Optimization Assessments at U.S. Army Installations: Caserma Ederle Vicenza, Italy","publication_year":2009,"publication_date":"2009-01-17","ids":{"openalex":"https://openalex.org/W67949595","doi":"https://doi.org/10.21236/ada520818","mag":"67949595"},"language":"en","primary_location":{"id":"doi:10.21236/ada520818","doi":"https://doi.org/10.21236/ada520818","is_oa":false,"landing_page_url":"http://doi.org/10.21236/ada520818","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"US Dept of the Army","raw_type":"report"},"volume":null,"type":"report","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5085992088","display_name":"David M. Underwood","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"David M. Underwood","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5051286461","display_name":"Alexander Michael Zhivov","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Alexander Zhivov","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5075379076","display_name":"Alfred Woody","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Alfred Woody","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5068121067","display_name":"Curt Bj\u00f6rk","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Curt Bjork","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5021828025","display_name":"Dieter Neth","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Dieter Neth","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"last","author":{"id":"https://openalex.org/A5023713040","display_name":"Roland Ziegler","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Roland Ziegler","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":null,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":null,"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.8314999938011169,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.8314999938011169,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13263","display_name":"Building energy efficiency and sustainability","score":0.13680000603199005,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11954","display_name":"Energy Efficiency and Management","score":0.02889999933540821,"subfield":{"id":"https://openalex.org/subfields/2105","display_name":"Renewable Energy, Sustainability and the Environment"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/military-installations","display_name":"military installations","score":0.7760000228881836},{"id":"https://openalex.org/keywords/energy-efficient-technologies","display_name":"energy-saving technologies","score":0.9279999732971191},{"id":"https://openalex.org/keywords/energy-efficiency","display_name":"energy efficiency","score":0.6740000247955322},{"id":"https://openalex.org/keywords/steam-distribution-systems","display_name":"steam distribution systems","score":0.9900000095367432},{"id":"https://openalex.org/keywords/building-envelope","display_name":"building envelope","score":0.8730000257492065},{"id":"https://openalex.org/keywords/ventilation-systems","display_name":"ventilation systems","score":0.8579999804496765},{"id":"https://openalex.org/keywords/lighting-systems","display_name":"lighting systems","score":0.6890000104904175},{"id":"https://openalex.org/keywords/energy-conservation","display_name":"energy conservation","score":0.4569999873638153}],"concepts":[{"id":"https://openalex.org/C178802073","wikidata":"https://www.wikidata.org/wiki/Q8421","display_name":"Aeronautics","level":1,"score":0.4213927686214447},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3691285252571106},{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.36145874857902527}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.21236/ada520818","doi":"https://doi.org/10.21236/ada520818","is_oa":false,"landing_page_url":"http://doi.org/10.21236/ada520818","pdf_url":null,"source":null,"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"US Dept of the Army","raw_type":"report"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","score":0.75,"display_name":"Affordable and clean energy"},{"id":"https://metadata.un.org/sdg/13","score":0.46149998903274536,"display_name":"Climate action"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W85731365","https://openalex.org/W94077186","https://openalex.org/W117524561","https://openalex.org/W2652756409","https://openalex.org/W183475895","https://openalex.org/W288300215","https://openalex.org/W340168340","https://openalex.org/W3209845200","https://openalex.org/W7042780676","https://openalex.org/W37565715"],"abstract_inverted_index":{"Abstract":[0],":":[1],"An":[2],"Energy":[3,19,22,65,76,98],"Optimization":[4,99],"Assessment":[5,100],"was":[6,72],"conducted":[7,73],"at":[8],"Caserma":[9,152],"Ederle":[10],"Vicenza,":[11],"Italy,":[12],"as":[13],"a":[14,102,176],"part":[15],"of":[16,79,94,106,131,178,181],"the":[17,50,55,75,80,95,107],"International":[18],"Agency":[20],"(IEA)":[21],"Conservation":[23],"in":[24,162,167,172],"Buildings":[25],"and":[26,35,37,44,64,87,111,125,128,138,170],"Community":[27],"Systems":[28],"(ECBCS)":[29],"initiative":[30],"to":[31,52,118,159],"identify":[32],"energy":[33,56,109,145,155],"inefficiencies":[34],"wastes":[36],"propose":[38],"energy-related":[39],"projects":[40],"with":[41],"applicable":[42],"funding":[43],"execution":[45],"methods":[46],"that":[47,149],"could":[48],"enable":[49],"installation":[51],"better":[53],"meet":[54],"reduction":[57],"requirements":[58],"mandated":[59],"by":[60,74,157],"Executive":[61],"Order":[62],"13123":[63],"Policy":[66],"Act":[67],"(EPAct)":[68],"2005.":[69],"The":[70,92,140],"study":[71,105,141],"Team,":[77],"composed":[78],"Construction":[81],"Engineering":[82],"Research":[83],"Laboratory":[84],"(ERDC-CERL)":[85],"researchers":[86],"their":[88,132],"subject":[89],"matter":[90],"experts.":[91],"scope":[93],"Annex":[96],"46":[97],"included":[101],"Level":[103],"I":[104],"central":[108],"plants":[110],"associated":[112],"steam":[113],"distribution":[114],"systems":[115],"providing":[116],"heat":[117],"representative":[119],"administrative":[120],"buildings,":[121],"laundry,":[122],"dining":[123],"facilities,":[124],"other":[126],"buildings":[127],"an":[129],"analysis":[130],"building":[133],"envelopes,":[134],"ventilation":[135],"air":[136],"systems,":[137],"lighting.":[139],"identified":[142],"28":[143],"different":[144],"conservation":[146],"measures":[147],"(ECMs)":[148],"would":[150],"reduce":[151],"Ederle's":[153],"annual":[154],"use":[156],"up":[158],"1,702":[160],"MWh/yr":[161],"electrical":[163],"savings,":[164],"12,922":[165],"MMBtu/yr":[166],"thermal":[168],"energy,":[169],"$37K/yr":[171],"maintenance":[173],"savings":[174],"for":[175],"total":[177],"$769":[179],"K/yr":[180],"savings.":[182]},"counts_by_year":[],"updated_date":"2026-09-22T06:50:58.402377","created_date":"2016-06-24T00:00:00"}
