{"id":"https://openalex.org/W658447239","doi":null,"title":"Facilities Engineering and Management Handbook: Commercial, Industrial, and Institutional Buildings","display_name":"Facilities Engineering and Management Handbook: Commercial, Industrial, and Institutional Buildings","alternate_titles":[],"publication_year":2000,"publication_date":"2000-12-06","ids":{"openalex":"https://openalex.org/W658447239","mag":"658447239"},"language":"en","primary_location":{"id":"mag:658447239","doi":null,"is_oa":false,"landing_page_url":"https://ci.nii.ac.jp/ncid/BA51067476","pdf_url":null,"source":null,"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":null},"parent_works":[],"lineage":["https://openalex.org/W658447239"],"child_works_count":0,"type":"book","is_traditional":true,"indexed_in":[],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5060172878","display_name":"Paul R. Smith","orcid":"https://orcid.org/0000-0002-7850-8440","observed_orcids":["https://orcid.org/0000-0002-7850-8440"]},"institutions":[],"countries":[],"is_corresponding":true,"contributor_roles":[],"raw_author_name":"Paul Smith","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":["https://openalex.org/A5060172878"],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":3.2143,"has_fulltext":false,"cited_by_count":14,"reviewed_by_count":0,"citation_normalized_percentile":{"value":0.89977728,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":86,"max":97},"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T13263","display_name":"Building energy efficiency and sustainability","score":0.5800999999046326,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T13263","display_name":"Building energy efficiency and sustainability","score":0.5800999999046326,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12256","display_name":"Facilities and Workplace Management","score":0.23819999396800995,"subfield":{"id":"https://openalex.org/subfields/2216","display_name":"Architecture"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.0608999989926815,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/facilities-engineering","display_name":"facilities engineering","score":0.7630000114440918},{"id":"https://openalex.org/keywords/building-management","display_name":"building management","score":0.8360000252723694},{"id":"https://openalex.org/keywords/commercial-buildings","display_name":"commercial buildings","score":0.9229999780654907},{"id":"https://openalex.org/keywords/industrial-buildings","display_name":"industrial buildings","score":0.9649999737739563},{"id":"https://openalex.org/keywords/institutional-building","display_name":"institutional building","score":0.9959999918937683},{"id":"https://openalex.org/keywords/mechanical-systems","display_name":"mechanical systems","score":0.8009999990463257},{"id":"https://openalex.org/keywords/electrical-systems","display_name":"electrical systems","score":0.9890000224113464},{"id":"https://openalex.org/keywords/building-codes-and-standards","display_name":"building codes and standards","score":0.7549999952316284},{"id":"https://openalex.org/keywords/building-information-management","display_name":"building information management","score":0.6639999747276306},{"id":"https://openalex.org/keywords/boilers","display_name":"boilers","score":0.6499999761581421},{"id":"https://openalex.org/keywords/refrigeration-equipment","display_name":"refrigeration equipment","score":0.8299999833106995},{"id":"https://openalex.org/keywords/ventilation","display_name":"ventilation","score":0.6819999814033508},{"id":"https://openalex.org/keywords/air-conditioning","display_name":"air conditioning","score":0.859000027179718},{"id":"https://openalex.org/keywords/pumps","display_name":"pumps","score":0.6470000147819519},{"id":"https://openalex.org/keywords/fans","display_name":"fans","score":0.8080000281333923},{"id":"https://openalex.org/keywords/vibration-and-noise-reduction","display_name":"noise and vibration reduction","score":0.925000011920929},{"id":"https://openalex.org/keywords/plumbing","display_name":"plumbing","score":0.9760000109672546},{"id":"https://openalex.org/keywords/water-supply","display_name":"water supply","score":0.6470000147819519},{"id":"https://openalex.org/keywords/alarm-system","display_name":"alarm system","score":0.9340000152587891},{"id":"https://openalex.org/keywords/lighting","display_name":"lighting","score":0.859000027179718},{"id":"https://openalex.org/keywords/electrical-distribution","display_name":"electrical distribution","score":0.6169999837875366},{"id":"https://openalex.org/keywords/energy-management","display_name":"energy management","score":0.8140000104904175},{"id":"https://openalex.org/keywords/lightning-protection","display_name":"lightning protection","score":0.8610000014305115},{"id":"https://openalex.org/keywords/communication-systems","display_name":"communication systems","score":0.8149999976158142},{"id":"https://openalex.org/keywords/building-automation","display_name":"building automation","score":0.9380000233650208},{"id":"https://openalex.org/keywords/computer-room","display_name":"computer rooms","score":0.9789999723434448},{"id":"https://openalex.org/keywords/human-factors","display_name":"human factors","score":0.9300000071525574}],"concepts":[{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.7013118863105774},{"id":"https://openalex.org/C103742991","wikidata":"https://www.wikidata.org/wiki/Q173725","display_name":"Air conditioning","level":2,"score":0.5958830118179321},{"id":"https://openalex.org/C506575596","wikidata":"https://www.wikidata.org/wiki/Q192043","display_name":"Electrical wiring","level":2,"score":0.47975218296051025},{"id":"https://openalex.org/C557531904","wikidata":"https://www.wikidata.org/wiki/Q897825","display_name":"Firefighting","level":2,"score":0.4607895314693451},{"id":"https://openalex.org/C162175671","wikidata":"https://www.wikidata.org/wiki/Q3749263","display_name":"Electrical equipment","level":2,"score":0.45710691809654236},{"id":"https://openalex.org/C122156500","wikidata":"https://www.wikidata.org/wiki/Q41399","display_name":"Fire protection","level":2,"score":0.44513097405433655},{"id":"https://openalex.org/C83931994","wikidata":"https://www.wikidata.org/wiki/Q1149653","display_name":"Building automation","level":2,"score":0.43987375497817993},{"id":"https://openalex.org/C115901376","wikidata":"https://www.wikidata.org/wiki/Q184199","display_name":"Automation","level":2,"score":0.4323437809944153},{"id":"https://openalex.org/C40293303","wikidata":"https://www.wikidata.org/wiki/Q27137","display_name":"Electric power","level":3,"score":0.42158693075180054},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.36772406101226807},{"id":"https://openalex.org/C170154142","wikidata":"https://www.wikidata.org/wiki/Q150737","display_name":"Architectural engineering","level":1,"score":0.34196075797080994},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.33322474360466003},{"id":"https://openalex.org/C147176958","wikidata":"https://www.wikidata.org/wiki/Q77590","display_name":"Civil engineering","level":1,"score":0.31432777643203735},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.31396055221557617},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.16562893986701965},{"id":"https://openalex.org/C185592680","wikidata":"https://www.wikidata.org/wiki/Q2329","display_name":"Chemistry","level":0,"score":0.0},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.0},{"id":"https://openalex.org/C62520636","wikidata":"https://www.wikidata.org/wiki/Q944","display_name":"Quantum mechanics","level":1,"score":0.0},{"id":"https://openalex.org/C97355855","wikidata":"https://www.wikidata.org/wiki/Q11473","display_name":"Thermodynamics","level":1,"score":0.0},{"id":"https://openalex.org/C178790620","wikidata":"https://www.wikidata.org/wiki/Q11351","display_name":"Organic chemistry","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"mag:658447239","doi":null,"is_oa":false,"landing_page_url":"https://ci.nii.ac.jp/ncid/BA51067476","pdf_url":null,"source":null,"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W2097560910","https://openalex.org/W7097944899","https://openalex.org/W4242724606","https://openalex.org/W4253046910","https://openalex.org/W600432869","https://openalex.org/W3205653639","https://openalex.org/W3181417272","https://openalex.org/W573810887"],"abstract_inverted_index":{"Part":[0,39,89,135],"A":[1],"Building":[2],"fundamental:":[3],"mechanical":[4,37,77],"and":[5,11,17,25,29,34,55,69,75,80,87,93,95,99],"electrical":[6,106,117],"systems":[7,78,104,108,112,116,127,130],"evolution":[8],"building":[9,15,128],"codes":[10],"standards":[12],"project":[13],"management":[14,19,123],"configuration":[16],"information":[18],"design":[20,26],"loading":[21],"for":[22,65,119],"equipment":[23,46,52],"engineering":[24],"considerations":[27],"defining":[28],"improving":[30],"your":[31],"processes":[32],"maintenance":[33],"operations":[35],"programs":[36],"systems.":[38],"B":[40],"Mechanical":[41],"systems:":[42,97],"boilers":[43],"fuel":[44],"burning":[45],"boiler":[47],"room":[48],"auxiliaries":[49],"fuels":[50],"refrigeration":[51],"heating":[53],"temperature":[54],"humidity":[56],"ventilation":[57],"air":[58,66],"filtration":[59],"odour":[60],"control":[61,82],"central":[62],"plant":[63],"facilities":[64],"conditioning":[67],"centrifugal":[68],"positive":[70],"displacement":[71],"pumps":[72],"fans":[73],"balancing":[74],"testing":[76],"noise":[79],"vibration":[81],"plumbing":[83],"water":[84],"supply,":[85],"treatment":[86],"conditioning.":[88],"C":[90],"Electrical,":[91],"instrumentation":[92],"controls,":[94],"computer":[96,131],"fire":[98],"life":[100],"safety":[101],"analysis":[102],"alarm":[103],"lighting":[105],"wiring":[107],"high":[109],"voltage":[110],"distribution":[111,115],"secondary":[113],"power":[114],"service":[118],"vertical":[120],"transportation":[121],"energy":[122],"lightening":[124],"protection":[125],"communications":[126],"automation":[129],"rooms":[132],"human":[133],"factors.":[134],"D":[136],"Appendices:":[137],"conversion":[138],"tables":[139],"glossary":[140],"tables.":[141]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W658447239","counts_by_year":[{"year":2026,"cited_by_count":1},{"year":2021,"cited_by_count":1},{"year":2020,"cited_by_count":4},{"year":2019,"cited_by_count":1},{"year":2015,"cited_by_count":1}],"updated_date":"2026-11-22T12:46:00.618207","created_date":"2016-06-24T00:00:00"}
