{"id":"https://openalex.org/W587705244","doi":null,"title":"HVAC testing, adjusting, and balancing manual","display_name":"HVAC testing, adjusting, and balancing manual","alternate_titles":[],"publication_year":1997,"publication_date":"1997-01-01","ids":{"openalex":"https://openalex.org/W587705244","mag":"587705244"},"language":"en","primary_location":{"id":"mag:587705244","doi":null,"is_oa":false,"landing_page_url":"http://ci.nii.ac.jp/ncid/BA41377477","pdf_url":null,"source":{"id":"https://openalex.org/S4306463609","display_name":"McGraw-Hill eBooks","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/P4323253411","host_organization_name":"McGraw-Hill","host_organization_lineage":["https://openalex.org/P4323253411"],"host_organization_lineage_names":["McGraw-Hill"],"type":"ebook platform"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":"McGraw-Hill eBooks","raw_type":null},"parent_works":[],"lineage":["https://openalex.org/W587705244"],"child_works_count":0,"type":"book","is_traditional":true,"indexed_in":[],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":null,"display_name":"J. H. Gladstone","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"J. H. Gladstone","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"last","author":{"id":"https://openalex.org/A5004414593","display_name":"W. David Bevirt","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"W. David Bevirt","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":8,"citation_normalized_percentile":{"value":0.0,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":88,"max":93},"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.6205999851226807,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.6205999851226807,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13263","display_name":"Building energy efficiency and sustainability","score":0.25440001487731934,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11529","display_name":"Refrigeration and Air Conditioning Technologies","score":0.10570000112056732,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/airflow-measurement","display_name":"air flow measurement","score":0.9449999928474426},{"id":"https://openalex.org/keywords/fan-drive","display_name":"fan drive","score":0.7609999775886536},{"id":"https://openalex.org/keywords/hydronic-systems","display_name":"hydronic systems","score":0.8740000128746033},{"id":"https://openalex.org/keywords/pump-curves","display_name":"pump curves","score":0.6069999933242798},{"id":"https://openalex.org/keywords/flow-measurement","display_name":"flow measurement","score":0.6489999890327454},{"id":"https://openalex.org/keywords/psychometrics","display_name":"psychometrics","score":0.753000020980835},{"id":"https://openalex.org/keywords/indoor-air-quality","display_name":"indoor air quality","score":0.8949999809265137},{"id":"https://openalex.org/keywords/energy-recovery","display_name":"energy recovery","score":0.8040000200271606},{"id":"https://openalex.org/keywords/hvac-control","display_name":"HVAC control","score":0.9380000233650208},{"id":"https://openalex.org/keywords/sound-and-vibration","display_name":"sound and vibration","score":0.8619999885559082},{"id":"https://openalex.org/keywords/hvac-troubleshooting","display_name":"HVAC troubleshooting","score":0.9279999732971191}],"concepts":[{"id":"https://openalex.org/C122346748","wikidata":"https://www.wikidata.org/wiki/Q1798773","display_name":"HVAC","level":3,"score":0.9178636074066162},{"id":"https://openalex.org/C116067010","wikidata":"https://www.wikidata.org/wiki/Q4698686","display_name":"Airflow","level":2,"score":0.7254189848899841},{"id":"https://openalex.org/C2781212128","wikidata":"https://www.wikidata.org/wiki/Q2256181","display_name":"Duct (anatomy)","level":2,"score":0.6916193962097168},{"id":"https://openalex.org/C127094628","wikidata":"https://www.wikidata.org/wiki/Q794827","display_name":"Cleanroom","level":2,"score":0.6807436943054199},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.5925314426422119},{"id":"https://openalex.org/C206145494","wikidata":"https://www.wikidata.org/wiki/Q4654236","display_name":"ASHRAE 90.1","level":2,"score":0.5133901834487915},{"id":"https://openalex.org/C147494362","wikidata":"https://www.wikidata.org/wiki/Q2078905","display_name":"Troubleshooting","level":2,"score":0.49545538425445557},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.48845353722572327},{"id":"https://openalex.org/C65469","wikidata":"https://www.wikidata.org/wiki/Q905504","display_name":"Indoor air quality","level":2,"score":0.4580051898956299},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.43396976590156555},{"id":"https://openalex.org/C103742991","wikidata":"https://www.wikidata.org/wiki/Q173725","display_name":"Air conditioning","level":2,"score":0.28435218334198},{"id":"https://openalex.org/C153294291","wikidata":"https://www.wikidata.org/wiki/Q25261","display_name":"Meteorology","level":1,"score":0.13638323545455933},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.10031715035438538},{"id":"https://openalex.org/C87717796","wikidata":"https://www.wikidata.org/wiki/Q146326","display_name":"Environmental engineering","level":1,"score":0.10022196173667908},{"id":"https://openalex.org/C192562407","wikidata":"https://www.wikidata.org/wiki/Q228736","display_name":"Materials science","level":0,"score":0.0903775691986084},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.09026333689689636},{"id":"https://openalex.org/C142724271","wikidata":"https://www.wikidata.org/wiki/Q7208","display_name":"Pathology","level":1,"score":0.0},{"id":"https://openalex.org/C71924100","wikidata":"https://www.wikidata.org/wiki/Q11190","display_name":"Medicine","level":0,"score":0.0},{"id":"https://openalex.org/C171250308","wikidata":"https://www.wikidata.org/wiki/Q11468","display_name":"Nanotechnology","level":1,"score":0.0}],"mesh":[],"locations_count":1,"locations":[{"id":"mag:587705244","doi":null,"is_oa":false,"landing_page_url":"http://ci.nii.ac.jp/ncid/BA41377477","pdf_url":null,"source":{"id":"https://openalex.org/S4306463609","display_name":"McGraw-Hill eBooks","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/P4323253411","host_organization_name":"McGraw-Hill","host_organization_lineage":["https://openalex.org/P4323253411"],"host_organization_lineage_names":["McGraw-Hill"],"type":"ebook platform"},"license":null,"license_id":null,"version":null,"is_accepted":false,"is_published":false,"raw_source_name":"McGraw-Hill eBooks","raw_type":null}],"best_oa_location":null,"sustainable_development_goals":[],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W7222873491","https://openalex.org/W3202071617","https://openalex.org/W3202372822","https://openalex.org/W3206162554","https://openalex.org/W3207154436","https://openalex.org/W3203409213","https://openalex.org/W3202580308","https://openalex.org/W3099559655","https://openalex.org/W3199523883","https://openalex.org/W3204472524"],"abstract_inverted_index":{"A":[0],"Standard":[1],"TAB":[2,23,28,64,78,81],"Procedures.":[3],"Airflow":[4],"Measurement":[5],"Equations.":[6,8,16,57],"Fan":[7,9,13],"and":[10,15,51,55,75],"System":[11,18,52],"Curves.":[12,53],"Drives":[14],"Duct":[17],"Pressure":[19],"Losses.":[20],"Use":[21,26],"of":[22,27,39,60],"Instruments":[24,29],"(Airflow).":[25],"(Hydronic,":[30],"Thermal,":[31],"Rotational,":[32],"Electrical).":[33],"HVAC":[34,69],"Unit":[35],"Air":[36,40,46],"Measurements.":[37],"Effects":[38],"Densities.":[41],"Heat":[42],"Transfer.":[43],"Psychometrics.":[44],"Indoor":[45],"Quality.":[47],"Energy":[48],"Recovery.":[49],"Pumps":[50],"Pump":[54],"Hydronic":[56,61],"Flow":[58],"Measurements":[59],"Systems.":[62,71],"Recording":[63],"Data.":[65,68],"Basic":[66],"Electrical":[67],"Control":[70],"Cleanroom":[72],"Testing.":[73],"Sound":[74],"Vibration.":[76],"Troubleshooting.":[77],"Cost":[79],"Estimating.":[80],"Mathematics.":[82]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W587705244","counts_by_year":[{"year":2020,"cited_by_count":1}],"updated_date":"2026-11-16T12:05:36.265796","created_date":"2016-06-24T00:00:00"}
