{"id":"https://openalex.org/W49090291","doi":null,"title":"Ventilation and moisture in new energy-efficient manufactured homes","display_name":"Ventilation and moisture in new energy-efficient manufactured homes","publication_year":1991,"publication_date":"1991-06-01","ids":{"openalex":"https://openalex.org/W49090291","mag":"49090291"},"language":"en","primary_location":{"id":"pmh:oai:osti.gov:5754450","doi":null,"is_oa":true,"landing_page_url":"https://www.osti.gov/biblio/5754450","pdf_url":"https://www.osti.gov/servlets/purl/5754450","source":{"id":"https://openalex.org/S4306402487","display_name":"OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I139351228","host_organization_name":"Office of Scientific and Technical Information","host_organization_lineage":["https://openalex.org/I139351228"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":null},"volume":null,"type":"article","is_traditional":true,"indexed_in":[],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"https://www.osti.gov/servlets/purl/5754450","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5111413003","display_name":"Donald L. Hadley","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"D.L. Hadley","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5103345397","display_name":"Scott Bailey","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Scott Bailey","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"last","author":{"id":"https://openalex.org/A5091097191","display_name":"G.B. Parker","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"G.B. Parker","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":4.6915,"has_fulltext":true,"cited_by_count":1,"citation_normalized_percentile":{"value":0.89942639,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T13263","display_name":"Building energy efficiency and sustainability","score":0.5054000020027161,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T13263","display_name":"Building energy efficiency and sustainability","score":0.5054000020027161,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11002","display_name":"Indoor Air Quality and Microbial Exposure","score":0.2896000146865845,"subfield":{"id":"https://openalex.org/subfields/2307","display_name":"Health, Toxicology and Mutagenesis"},"field":{"id":"https://openalex.org/fields/23","display_name":"Environmental Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.14890000224113464,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/manufactured-housing","display_name":"manufactured housing","score":0.8820000290870667},{"id":"https://openalex.org/keywords/energy-efficient-housing","display_name":"energy-efficient housing","score":0.6650000214576721},{"id":"https://openalex.org/keywords/residential-ventilation","display_name":"residential ventilation","score":0.6010000109672546},{"id":"https://openalex.org/keywords/moisture","display_name":"moisture","score":0.39500001072883606},{"id":"https://openalex.org/keywords/condensation","display_name":"condensation","score":0.9660000205039978},{"id":"https://openalex.org/keywords/indoor-air-quality","display_name":"indoor air quality","score":0.7770000100135803},{"id":"https://openalex.org/keywords/air-exchange-rate","display_name":"air exchange rate","score":0.6449999809265137},{"id":"https://openalex.org/keywords/blower-door-test","display_name":"blower door test","score":0.8629999756813049},{"id":"https://openalex.org/keywords/exhaust-system","display_name":"exhaust system","score":0.5630000233650208},{"id":"https://openalex.org/keywords/pacific-northwest","display_name":"Pacific Northwest","score":0.8600000143051147},{"id":"https://openalex.org/keywords/occupant-survey","display_name":"occupant survey","score":0.597000002861023},{"id":"https://openalex.org/keywords/bonneville-power-administration","display_name":"Bonneville Power Administration","score":0.7680000066757202}],"concepts":[{"id":"https://openalex.org/C39432304","wikidata":"https://www.wikidata.org/wiki/Q188847","display_name":"Environmental science","level":0,"score":0.6194443106651306},{"id":"https://openalex.org/C200457457","wikidata":"https://www.wikidata.org/wiki/Q584049","display_name":"Ventilation (architecture)","level":2,"score":0.6099383234977722},{"id":"https://openalex.org/C2742236","wikidata":"https://www.wikidata.org/wiki/Q924713","display_name":"Efficient energy use","level":2,"score":0.4693656265735626},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.38155731558799744},{"id":"https://openalex.org/C153294291","wikidata":"https://www.wikidata.org/wiki/Q25261","display_name":"Meteorology","level":1,"score":0.36838775873184204},{"id":"https://openalex.org/C205649164","wikidata":"https://www.wikidata.org/wiki/Q1071","display_name":"Geography","level":0,"score":0.16307687759399414},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.10476920008659363}],"mesh":[],"locations_count":2,"locations":[{"id":"pmh:oai:osti.gov:5754450","doi":null,"is_oa":true,"landing_page_url":"https://www.osti.gov/biblio/5754450","pdf_url":"https://www.osti.gov/servlets/purl/5754450","source":{"id":"https://openalex.org/S4306402487","display_name":"OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I139351228","host_organization_name":"Office of Scientific and Technical Information","host_organization_lineage":["https://openalex.org/I139351228"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":null},{"id":"mag:49090291","doi":null,"is_oa":true,"landing_page_url":"https://www.osti.gov/biblio/5754450","pdf_url":null,"source":{"id":"https://openalex.org/S4306402487","display_name":"OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I139351228","host_organization_name":"Office of Scientific and Technical Information","host_organization_lineage":["https://openalex.org/I139351228"],"host_organization_lineage_names":[],"type":"repository"},"license":"other-oa","license_id":"https://openalex.org/licenses/other-oa","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information)","raw_type":null}],"best_oa_location":{"id":"pmh:oai:osti.gov:5754450","doi":null,"is_oa":true,"landing_page_url":"https://www.osti.gov/biblio/5754450","pdf_url":"https://www.osti.gov/servlets/purl/5754450","source":{"id":"https://openalex.org/S4306402487","display_name":"OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I139351228","host_organization_name":"Office of Scientific and Technical Information","host_organization_lineage":["https://openalex.org/I139351228"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":null},"sustainable_development_goals":[{"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7","score":0.75}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":true,"pdf":true},"content_urls":{"pdf":"https://content.openalex.org/works/W49090291.pdf","grobid_xml":"https://content.openalex.org/works/W49090291.grobid-xml"},"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W2169996796","https://openalex.org/W1561178633","https://openalex.org/W4229485074","https://openalex.org/W49042070","https://openalex.org/W1565647024","https://openalex.org/W7100735972","https://openalex.org/W2546805624","https://openalex.org/W124521965","https://openalex.org/W1510277451","https://openalex.org/W7063647853"],"abstract_inverted_index":{"Manufactured":[0],"housing":[1,8,23],"accounts":[2],"for":[3,89,162,221],"approximately":[4,26],"35%":[5],"of":[6,15,21,30,36,50,61,92,102,105,115,205,224,245,269,274,311,331,368,384,402],"new":[7,185,259,369,405],"starts":[9],"in":[10,120,138,177,235,351,365,377,404],"the":[11,16,22,37,43,51,83,87,103,106,133,139,156,196,206,213,222,232,254,265,270,312,329,332,362,378,391],"Pacific":[12,217,379],"Northwest":[13,207,218],"region":[14],"United":[17],"States.":[18],"This":[19,141,267,358],"segment":[20],"market":[24],"represents":[25],"40":[27],"average":[28],"megawatts":[29],"potential":[31,88],"end-use":[32],"efficiency":[33],"resource.":[34],"Many":[35],"energy":[38,69,72,163,255],"conservation":[39],"measures":[40,63],"implemented":[41],"at":[42,328],"factory":[44],"or":[45],"during":[46,195],"setup":[47],"involve":[48],"tightening":[49],"shell,":[52],"thereby":[53],"reducing":[54],"whole":[55],"house":[56,338],"infiltration.":[57],"While":[58],"these":[59,62,168,184],"goal":[60],"will":[64,360,393],"reduce":[65],"heating":[66,215],"and":[67,98,117,242,292,323,343,355,370,375],"cooling":[68],"consumption,":[70],"this":[71,366],"savings":[73],"is":[74,86],"not":[75,251],"without":[76],"its":[77],"negative":[78],"side":[79],"effects.":[80],"Along":[81],"with":[82],"reduced":[84],"infiltration":[85,116],"increased":[90],"levels":[91],"indoor":[93,107],"air":[94,304],"contaminates":[95],"(including":[96],"moisture)":[97],"a":[99,113,125,243,293],"general":[100],"lowering":[101],"quality":[104],"air.":[108],"In":[109,182,307],"order":[110],"to":[111,146,154,253,264,288,301,334],"establish":[112],"database":[114],"ventilation":[118,233,344],"characteristics":[119,234,364],"current":[121,247],"practice":[122,248],"manufactured":[123,186,240,249,372,407],"housing,":[124],"multiyear":[126],"field":[127],"testing":[128,333],"program":[129,142,271],"was":[130,143,272,286,299,319,326],"undertaken":[131],"by":[132,390],"Bonneville":[134,227],"Power":[135,228],"Administration":[136,229],"begining":[137],"mid-1980s.":[140],"later":[144],"expanded":[145],"include":[147],"20":[148],"homes":[149,187,193,241,250,261,348,373],"that":[150,174,200],"had":[151],"been":[152],"upgraded":[153],"meet":[155],"regional":[157],"Model":[158],"Conservation":[159],"Standards":[160],"(MCS)":[161],"efficiency.":[164],"The":[165,258,347,381],"results":[166,398],"from":[167],"initial":[169],"studies":[170],"(Table":[171],"I)":[172],"indicates":[173],"significant":[175],"improvement":[176],"shell":[178,290],"tightness":[179],"are":[180],"possible.":[181],"fact,":[183],"were":[188,201,262,349],"also":[189,394],"tighter":[190],"than":[191],"site-built":[192],"constructed":[194,238],"same":[197],"time":[198,330],"period":[199],"tested":[202],"as":[203,388],"part":[204,273],"Residential":[208,276],"Infiltration":[209],"Survey":[210],"(NORIS).":[211],"During":[212],"1989-1990":[214],"season,":[216],"Laboratory":[219],"(PNL)":[220],"Office":[223],"Energy":[225],"Resources,":[226],"(Bonneville),":[230],"measured":[231],"139":[236],"newly":[237],"energy-efficient":[239,260,371,406],"sample":[244,367],"35":[246],"built":[252,263,374],"efficient":[256],"standards.":[257],"MCS.":[266],"phase":[268],"Bonneville's":[275],"Construction":[277],"Demonstration":[278],"Program":[279],"(RCDP).":[280],"A":[281],"standard":[282],"blower":[283],"door":[284],"test":[285],"used":[287,300],"estimate":[289,302],"leakiness,":[291],"passive":[294],"perfluorocarbon":[295],"tracer":[296],"(PFT)":[297],"technique":[298],"overall":[303],"exchange":[305],"rates.":[306],"addition,":[308],"one-time":[309],"measurements":[310],"designated":[313],"whole-house":[314],"exhaust":[315],"system":[316,345],"flow":[317],"rate":[318],"taken.":[320],"An":[321],"occupant":[322,341],"structure":[324],"survey":[325],"conducted":[327],"obtain":[335],"information":[336],"on":[337],"characteristics,":[339],"daily":[340],"activities":[342],"operation.":[346],"located":[350],"Oregon,":[352],"Washington,":[353],"Idaho,":[354],"western":[356],"Montana.":[357],"paper":[359],"summarize":[361],"infiltration/ventilation":[363],"situated":[376],"Northwest.":[380],"reported":[382],"incidence":[383],"moisture":[385],"and/or":[386],"condensation":[387],"observed":[389],"occupants":[392],"be":[395,400],"detailed.":[396],"These":[397],"should":[399],"indicative":[401],"conditions":[403],"housing.":[408]},"counts_by_year":[],"updated_date":"2026-11-07T11:25:07.637180","created_date":"2016-06-24T00:00:00"}
