{"id":"https://openalex.org/W45108359","doi":"https://doi.org/10.3130/aijax.402.0_9","title":"AIR TIGHTNESS OF MAIN DOORS AND EXTERIOR WALLS : Study on the stack effect of tall office building (Part 2)","display_name":"AIR TIGHTNESS OF MAIN DOORS AND EXTERIOR WALLS : Study on the stack effect of tall office building (Part 2)","publication_year":1989,"publication_date":"1989-01-01","ids":{"openalex":"https://openalex.org/W45108359","doi":"https://doi.org/10.3130/aijax.402.0_9","mag":"45108359"},"language":"en","primary_location":{"id":"doi:10.3130/aijax.402.0_9","doi":"https://doi.org/10.3130/aijax.402.0_9","is_oa":true,"landing_page_url":"https://doi.org/10.3130/aijax.402.0_9","pdf_url":"https://www.jstage.jst.go.jp/article/aijax/402/0/402_KJ00004074943/_pdf","source":{"id":"https://openalex.org/S4210187398","display_name":"Journal of Architecture Planning and Environmental Engineering (Transactions of AIJ)","issn_l":"0910-8017","issn":["0910-8017","2433-0043"],"is_oa":true,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Journal of Architecture, Planning and Environmental Engineering (Transactions of AIJ)","raw_type":"journal-article"},"volume":null,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"diamond","oa_url":"https://www.jstage.jst.go.jp/article/aijax/402/0/402_KJ00004074943/_pdf","any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5070397692","display_name":"Shin Hayakawa","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"SHIN HAYAKAWA","raw_affiliation_strings":["KAJIMA Institute of Construction Technology"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"KAJIMA Institute of Construction Technology","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5046449446","display_name":"Satoshi Togari","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"SATOSHI TOGARI","raw_affiliation_strings":["KAJIMA Institute of Construction Technology"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"KAJIMA Institute of Construction Technology","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":true,"cited_by_count":2,"citation_normalized_percentile":{"value":0.01147715,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"402","issue":"0","first_page":"9","last_page":"18"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T13263","display_name":"Building energy efficiency and sustainability","score":0.5557000041007996,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T13263","display_name":"Building energy efficiency and sustainability","score":0.5557000041007996,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11371","display_name":"Wind and Air Flow Studies","score":0.3237000107765198,"subfield":{"id":"https://openalex.org/subfields/2305","display_name":"Environmental Engineering"},"field":{"id":"https://openalex.org/fields/23","display_name":"Environmental Science"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10121","display_name":"Building Energy and Comfort Optimization","score":0.10109999775886536,"subfield":{"id":"https://openalex.org/subfields/2215","display_name":"Building and Construction"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/air-tightness","display_name":"air tightness","score":0.9120000004768372},{"id":"https://openalex.org/keywords/air-infiltration-rate","display_name":"air infiltration rate","score":0.7889999747276306},{"id":"https://openalex.org/keywords/stack-effect","display_name":"stack effect","score":0.8619999885559082},{"id":"https://openalex.org/keywords/high-rise-office-buildings","display_name":"high-rise office buildings","score":0.8619999885559082},{"id":"https://openalex.org/keywords/exterior-walls","display_name":"exterior walls","score":0.7229999899864197},{"id":"https://openalex.org/keywords/doors","display_name":"doors","score":0.6650000214576721},{"id":"https://openalex.org/keywords/elevator-doors","display_name":"elevator doors","score":0.6859999895095825},{"id":"https://openalex.org/keywords/revolving-door","display_name":"revolving door","score":0.996999979019165},{"id":"https://openalex.org/keywords/pressure-testing","display_name":"pressure testing","score":0.6980000138282776},{"id":"https://openalex.org/keywords/cast-in-place-concrete","display_name":"cast-in-place concrete","score":0.8299999833106995},{"id":"https://openalex.org/keywords/precast-concrete-panels","display_name":"precast concrete panels","score":0.949999988079071},{"id":"https://openalex.org/keywords/differential-pressure","display_name":"pressure difference","score":0.5370000004768372}],"concepts":[{"id":"https://openalex.org/C125209513","wikidata":"https://www.wikidata.org/wiki/Q4037520","display_name":"Doors","level":2,"score":0.8481931686401367},{"id":"https://openalex.org/C56550808","wikidata":"https://www.wikidata.org/wiki/Q1709610","display_name":"Stack effect","level":2,"score":0.6126829385757446},{"id":"https://openalex.org/C66938386","wikidata":"https://www.wikidata.org/wiki/Q633538","display_name":"Structural engineering","level":1,"score":0.5925056338310242},{"id":"https://openalex.org/C125450124","wikidata":"https://www.wikidata.org/wiki/Q831541","display_name":"Precast concrete","level":2,"score":0.5488945245742798},{"id":"https://openalex.org/C116067010","wikidata":"https://www.wikidata.org/wiki/Q4698686","display_name":"Airflow","level":2,"score":0.48824289441108704},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.4852135479450226},{"id":"https://openalex.org/C147021018","wikidata":"https://www.wikidata.org/wiki/Q252451","display_name":"Elevator","level":2,"score":0.47734931111335754},{"id":"https://openalex.org/C78519656","wikidata":"https://www.wikidata.org/wiki/Q101333","display_name":"Mechanical engineering","level":1,"score":0.18846076726913452},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.1665184497833252},{"id":"https://openalex.org/C153294291","wikidata":"https://www.wikidata.org/wiki/Q25261","display_name":"Meteorology","level":1,"score":0.10119548439979553}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.3130/aijax.402.0_9","doi":"https://doi.org/10.3130/aijax.402.0_9","is_oa":true,"landing_page_url":"https://doi.org/10.3130/aijax.402.0_9","pdf_url":"https://www.jstage.jst.go.jp/article/aijax/402/0/402_KJ00004074943/_pdf","source":{"id":"https://openalex.org/S4210187398","display_name":"Journal of Architecture Planning and Environmental Engineering (Transactions of AIJ)","issn_l":"0910-8017","issn":["0910-8017","2433-0043"],"is_oa":true,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Journal of Architecture, Planning and Environmental Engineering (Transactions of AIJ)","raw_type":"journal-article"}],"best_oa_location":{"id":"doi:10.3130/aijax.402.0_9","doi":"https://doi.org/10.3130/aijax.402.0_9","is_oa":true,"landing_page_url":"https://doi.org/10.3130/aijax.402.0_9","pdf_url":"https://www.jstage.jst.go.jp/article/aijax/402/0/402_KJ00004074943/_pdf","source":{"id":"https://openalex.org/S4210187398","display_name":"Journal of Architecture Planning and Environmental Engineering (Transactions of AIJ)","issn_l":"0910-8017","issn":["0910-8017","2433-0043"],"is_oa":true,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Journal of Architecture, Planning and Environmental Engineering (Transactions of AIJ)","raw_type":"journal-article"},"sustainable_development_goals":[],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":true,"grobid_xml":true},"content_urls":{"pdf":"https://content.openalex.org/works/W45108359.pdf","grobid_xml":"https://content.openalex.org/works/W45108359.grobid-xml"},"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W2147165410","https://openalex.org/W2777113381","https://openalex.org/W7036286194","https://openalex.org/W6891631567","https://openalex.org/W19140993","https://openalex.org/W2035641252","https://openalex.org/W2569938189","https://openalex.org/W2229846135","https://openalex.org/W6992743612","https://openalex.org/W4298909011"],"abstract_inverted_index":{"Air":[0,43],"infiltration":[1],"rate":[2,32,82],"characteristics":[3,57],"of":[4,10,45,50,61,98,104,117],"exterior":[5,34,100,145,164],"walls":[6,35,130,165],"and":[7,19,36,138],"some":[8],"kinds":[9],"doors":[11],"like":[12],"an":[13],"elevator":[14],"door,":[15],"a":[16,20,40],"staircase":[17,68],"door":[18,22,69,72,76],"revolving":[21,75],"are":[23],"indispensable":[24],"to":[25,125,175,184],"estimating":[26],"the":[27,30,94],"pressure":[28,85],"distribution,":[29],"in-filtration":[31],"through":[33],"air":[37,102,147],"flow":[38,81],"in":[39,59],"building.":[41],"1.":[42,66],"Tightness":[44],"Main":[46],"Doors":[47],"From":[48],"results":[49],"pressurizing":[51],"tests,":[52,63],"authors":[53],"proposed":[54],"their":[55],"practical":[56],"equations,":[58],"consideration":[60],"Tamura's":[62],"as":[64,149,170],"follows;":[65,150,171],"tight":[67,152],"Q=150\u0394P^<1/2>":[70],"2.elevator":[71],"Q=500\u0394P^<1/2>":[73],"3.":[74],"Q=170\u0394P^<1/1.5>":[77],"where,":[78],"Q":[79],":":[80,84],"(m^3/h),\u0394P":[83],"difference":[86],"(kg/m^2)":[87],"2.":[88],"Exterior":[89],"wall":[90,101,146,153,156,160],"Authors":[91,142],"have":[92,143,166],"developed":[93],"simple":[95],"test":[96],"method":[97,122],"evaluating":[99],"tightness":[103,148],"actual":[105],"tall":[106,127],"office":[107],"buildings,":[108,128],"which":[109],"utilizes":[110],"buoyancy":[111],"caused":[112],"by":[113],"stack":[114],"effect":[115],"instead":[116],"fans":[118],"for":[119],"prssurization.":[120],"This":[121],"was":[123],"applied":[124],"three":[126],"whose":[129],"were":[131],"cast":[132],"-in-place":[133],"concrete,":[134],"precast":[135],"concrete":[136],"panel":[137],"metallic":[139],"curtain":[140,182],"wall.":[141],"classified":[144,169],"a.":[151],"Q=0.72\u0394P^<1/1.5>(m^3/h\u30fbm^2)":[154],"b.average":[155],"Q=1.44\u0394P^<1/1.5>(m^3/h\u30fbm^2)":[157],"c.":[158],"loose":[159,185],"Q=2.88\u0394P^<1/1.5>(m^3/h\u30fbm^2)":[161],"And":[162],"tested":[163],"been":[167],"tentatively":[168],"a.Cast-in-place":[172],"RC":[173],"construction\u2026tight":[174],"average":[176],"b.S":[177],"or":[178],"SRC":[179],"construction":[180],"Metallic":[181],"wall\u2026average":[183],"PC":[186],"panel\u2026loose":[187]},"counts_by_year":[],"updated_date":"2026-08-09T07:27:16.801131","created_date":"2016-06-24T00:00:00"}