{"id":"https://openalex.org/W4417523735","doi":"https://doi.org/10.48550/arxiv.2504.21594","title":"Switching Transients in Constrained Transformer-Line/Cable Configurations","display_name":"Switching Transients in Constrained Transformer-Line/Cable Configurations","publication_year":2025,"publication_date":"2025-04-30","ids":{"openalex":"https://openalex.org/W4417523735","doi":"https://doi.org/10.48550/arxiv.2504.21594"},"language":"en","primary_location":{"id":"pmh:oai:arXiv.org:2504.21594","doi":null,"is_oa":true,"landing_page_url":"http://arxiv.org/abs/2504.21594","pdf_url":"https://arxiv.org/pdf/2504.21594","source":{"id":"https://openalex.org/S4306400194","display_name":"arXiv (Cornell University)","issn_l":"2331-8422","issn":["2331-8422"],"is_oa":true,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I205783295","host_organization_name":"Cornell University","host_organization_lineage":["https://openalex.org/I205783295"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"text"},"volume":null,"type":"preprint","is_traditional":true,"indexed_in":["arxiv","datacite"],"open_access":{"is_oa":true,"oa_status":"green","oa_url":"https://arxiv.org/pdf/2504.21594","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":null,"display_name":"Xiang, Y.","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Xiang, Y.","raw_affiliation_strings":["21, rue d'Artois , F-75008 PARIS","TU Eindhoven DNV GL Liander the Netherlands"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"21, rue d'Artois , F-75008 PARIS","institution_ids":[]},{"raw_affiliation_string":"TU Eindhoven DNV GL Liander the Netherlands","institution_ids":[]}]},{"author_position":"middle","author":{"id":null,"display_name":"Wu, L.","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Wu, L.","raw_affiliation_strings":["TU Eindhoven DNV GL Liander the Netherlands"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"TU Eindhoven DNV GL Liander the Netherlands","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5043377428","display_name":"Konstantinos Velitsikakis","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Velitsikakis, K.","raw_affiliation_strings":["TU Eindhoven DNV GL Liander the Netherlands"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"TU Eindhoven DNV GL Liander the Netherlands","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5079010622","display_name":"A.C.L. Janssen","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Janssen, A. L. J.","raw_affiliation_strings":["TU Eindhoven DNV GL Liander the Netherlands"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"TU Eindhoven DNV GL Liander the Netherlands","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":null,"has_fulltext":true,"cited_by_count":0,"citation_normalized_percentile":null,"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":null,"last_page":null},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T14502","display_name":"High-Voltage Power Transmission Systems","score":0.9340999722480774,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T14502","display_name":"High-Voltage Power Transmission Systems","score":0.9340999722480774,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10573","display_name":"Power Quality and Harmonics","score":0.021700000390410423,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11343","display_name":"Power Transformer Diagnostics and Insulation","score":0.007600000128149986,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/switching-transients","display_name":"switching transients","score":0.8379999995231628},{"id":"https://openalex.org/keywords/overhead-lines","display_name":"overhead lines","score":0.8840000033378601}],"concepts":[{"id":"https://openalex.org/C66322947","wikidata":"https://www.wikidata.org/wiki/Q11658","display_name":"Transformer","level":3,"score":0.7085999846458435},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.6179999709129333},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.5329999923706055},{"id":"https://openalex.org/C138838965","wikidata":"https://www.wikidata.org/wiki/Q1258026","display_name":"Delta-wye transformer","level":5,"score":0.5246000289916992},{"id":"https://openalex.org/C180850520","wikidata":"https://www.wikidata.org/wiki/Q2166404","display_name":"Isolation transformer","level":4,"score":0.49230000376701355},{"id":"https://openalex.org/C22958824","wikidata":"https://www.wikidata.org/wiki/Q565668","display_name":"Autotransformer","level":5,"score":0.436599999666214},{"id":"https://openalex.org/C50177738","wikidata":"https://www.wikidata.org/wiki/Q7834122","display_name":"Transformer effect","level":5,"score":0.4178999960422516},{"id":"https://openalex.org/C2775861652","wikidata":"https://www.wikidata.org/wiki/Q110701","display_name":"Overhead line","level":2,"score":0.397599995136261},{"id":"https://openalex.org/C17321440","wikidata":"https://www.wikidata.org/wiki/Q184909","display_name":"Flyback transformer","level":4,"score":0.3774000108242035},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.36239999532699585},{"id":"https://openalex.org/C117323899","wikidata":"https://www.wikidata.org/wiki/Q1907989","display_name":"Distribution transformer","level":4,"score":0.33719998598098755},{"id":"https://openalex.org/C9121194","wikidata":"https://www.wikidata.org/wiki/Q5377050","display_name":"Energy efficient transformer","level":5,"score":0.32339999079704285},{"id":"https://openalex.org/C111963331","wikidata":"https://www.wikidata.org/wiki/Q1129933","display_name":"Quadrature booster","level":5,"score":0.32199999690055847},{"id":"https://openalex.org/C196489102","wikidata":"https://www.wikidata.org/wiki/Q3442941","display_name":"Rotary variable differential transformer","level":5,"score":0.31139999628067017},{"id":"https://openalex.org/C101382669","wikidata":"https://www.wikidata.org/wiki/Q1616769","display_name":"Ferroresonance in electricity networks","level":4,"score":0.302700012922287},{"id":"https://openalex.org/C140311924","wikidata":"https://www.wikidata.org/wiki/Q200928","display_name":"Electric power transmission","level":2,"score":0.30090001225471497},{"id":"https://openalex.org/C168993435","wikidata":"https://www.wikidata.org/wiki/Q6501125","display_name":"Ground","level":2,"score":0.30000001192092896},{"id":"https://openalex.org/C121332964","wikidata":"https://www.wikidata.org/wiki/Q413","display_name":"Physics","level":0,"score":0.29910001158714294},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.2985000014305115},{"id":"https://openalex.org/C2780799671","wikidata":"https://www.wikidata.org/wiki/Q17087362","display_name":"Transient (computer programming)","level":2,"score":0.28540000319480896},{"id":"https://openalex.org/C133770746","wikidata":"https://www.wikidata.org/wiki/Q856535","display_name":"Current transformer","level":4,"score":0.27309998869895935},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.27090001106262207},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.267300009727478},{"id":"https://openalex.org/C7328023","wikidata":"https://www.wikidata.org/wiki/Q1280612","display_name":"Geomagnetically induced current","level":5,"score":0.2651999890804291},{"id":"https://openalex.org/C125884559","wikidata":"https://www.wikidata.org/wiki/Q369791","display_name":"Linear variable differential transformer","level":5,"score":0.2644999921321869}],"mesh":[],"locations_count":2,"locations":[{"id":"pmh:oai:arXiv.org:2504.21594","doi":null,"is_oa":true,"landing_page_url":"http://arxiv.org/abs/2504.21594","pdf_url":"https://arxiv.org/pdf/2504.21594","source":{"id":"https://openalex.org/S4306400194","display_name":"arXiv (Cornell University)","issn_l":"2331-8422","issn":["2331-8422"],"is_oa":true,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I205783295","host_organization_name":"Cornell University","host_organization_lineage":["https://openalex.org/I205783295"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"text"},{"id":"doi:10.48550/arxiv.2504.21594","doi":"https://doi.org/10.48550/arxiv.2504.21594","is_oa":true,"landing_page_url":"https://doi.org/10.48550/arxiv.2504.21594","pdf_url":null,"source":{"id":"https://openalex.org/S4306400194","display_name":"arXiv (Cornell University)","issn_l":"2331-8422","issn":["2331-8422"],"is_oa":true,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I205783295","host_organization_name":"Cornell University","host_organization_lineage":["https://openalex.org/I205783295"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":null,"is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"Preprint"}],"best_oa_location":{"id":"pmh:oai:arXiv.org:2504.21594","doi":null,"is_oa":true,"landing_page_url":"http://arxiv.org/abs/2504.21594","pdf_url":"https://arxiv.org/pdf/2504.21594","source":{"id":"https://openalex.org/S4306400194","display_name":"arXiv (Cornell University)","issn_l":"2331-8422","issn":["2331-8422"],"is_oa":true,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I205783295","host_organization_name":"Cornell University","host_organization_lineage":["https://openalex.org/I205783295"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"text"},"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/9","score":1.0,"display_name":"Industry, innovation and infrastructure"},{"id":"https://metadata.un.org/sdg/7","score":0.5690000057220459,"display_name":"Affordable and clean energy"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":true,"grobid_xml":true},"content_urls":{"pdf":"https://content.openalex.org/works/W4417523735.pdf","grobid_xml":"https://content.openalex.org/works/W4417523735.grobid-xml"},"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W7112357175","https://openalex.org/W2559028120","https://openalex.org/W4406244260","https://openalex.org/W2183463704","https://openalex.org/W2046123003","https://openalex.org/W4415546978","https://openalex.org/W3124396413","https://openalex.org/W1657723770","https://openalex.org/W1892156028","https://openalex.org/W3148265544"],"abstract_inverted_index":{"This":[0],"paper":[1],"investigates":[2],"the":[3,13,17,29,61],"transient":[4],"phenomena":[5],"that":[6],"occur":[7],"in":[8,12],"two":[9],"special":[10],"cases":[11],"Netherlands:":[14],"(A)":[15],"during":[16],"energization":[18,30],"of":[19,31,87],"a":[20,24,32,44,52,67,72],"power":[21,33],"transformer":[22,34,55,70],"via":[23],"cable":[25,50],"feeder":[26],"and":[27,51,58,71,79,94],"(B)":[28],"together":[35],"with":[36],"an":[37],"overhead":[38],"line":[39],"(OHL).":[40],"In":[41,64],"Case":[42,65],"A":[43],"7":[45],"km":[46],"long":[47],"150":[48],"kV":[49,54,69,75],"150/50":[53,68],"are":[56,77],"connected":[57,78],"energized":[59,80],"at":[60],"same":[62],"time.":[63],"B":[66],"short":[73],"50":[74],"OHL":[76],"simultaneously.":[81],"The":[82],"reason":[83],"behind":[84],"this":[85],"kind":[86],"situations":[88],"is":[89],"related":[90],"to":[91],"space":[92],"restrictions":[93],"cost":[95],"efficiency.":[96]},"counts_by_year":[],"updated_date":"2026-11-05T12:25:35.769452","created_date":"2025-10-10T00:00:00"}
