{"id":"https://openalex.org/W4417455477","doi":"https://doi.org/10.1049/icp.2025.3613","title":"Reliability life study of circuit breakers and their protection device","display_name":"Reliability life study of circuit breakers and their protection device","publication_year":2025,"publication_date":"2025-12-01","ids":{"openalex":"https://openalex.org/W4417455477","doi":"https://doi.org/10.1049/icp.2025.3613"},"language":"en","primary_location":{"id":"doi:10.1049/icp.2025.3613","doi":"https://doi.org/10.1049/icp.2025.3613","is_oa":false,"landing_page_url":"https://doi.org/10.1049/icp.2025.3613","pdf_url":null,"source":{"id":"https://openalex.org/S4404663355","display_name":"IET conference proceedings.","issn_l":"2732-4494","issn":["2732-4494"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":["jufo-1"],"host_organization":"https://openalex.org/P4310311714","host_organization_name":"Institution of Engineering and Technology","host_organization_lineage":["https://openalex.org/P4310311714"],"host_organization_lineage_names":["Institution of Engineering and Technology"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IET Conference Proceedings","raw_type":"journal-article"},"volume":null,"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5100328570","display_name":"Xingyu Li","orcid":"https://orcid.org/0000-0001-8034-1232","observed_orcids":["https://orcid.org/0000-0001-8034-1232"]},"institutions":[{"id":"https://openalex.org/I4210129465","display_name":"Wuhan Ship Development & Design Institute","ror":"https://ror.org/02mcdae06","country_code":"CN","type":"facility","lineage":["https://openalex.org/I4210129465"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Xingyu Li","raw_affiliation_strings":["Wuhan Second Ship Design and Research Institute, Wuhan, People's Republic of China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Wuhan Second Ship Design and Research Institute, Wuhan, People's Republic of China","institution_ids":["https://openalex.org/I4210129465"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5059699717","display_name":"Yiye Sun","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4210129465","display_name":"Wuhan Ship Development & Design Institute","ror":"https://ror.org/02mcdae06","country_code":"CN","type":"facility","lineage":["https://openalex.org/I4210129465"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Yiye Sun","raw_affiliation_strings":["Wuhan Second Ship Design and Research Institute, Wuhan, People's Republic of China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Wuhan Second Ship Design and Research Institute, Wuhan, People's Republic of China","institution_ids":["https://openalex.org/I4210129465"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5112125490","display_name":"Hu Guo","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4210129465","display_name":"Wuhan Ship Development & Design Institute","ror":"https://ror.org/02mcdae06","country_code":"CN","type":"facility","lineage":["https://openalex.org/I4210129465"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Hu Guo","raw_affiliation_strings":["Wuhan Second Ship Design and Research Institute, Wuhan, People's Republic of China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Wuhan Second Ship Design and Research Institute, Wuhan, People's Republic of China","institution_ids":["https://openalex.org/I4210129465"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5102390290","display_name":"Jinying Xiong","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4210129465","display_name":"Wuhan Ship Development & Design Institute","ror":"https://ror.org/02mcdae06","country_code":"CN","type":"facility","lineage":["https://openalex.org/I4210129465"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Jinying Xiong","raw_affiliation_strings":["Wuhan Second Ship Design and Research Institute, Wuhan, People's Republic of China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Wuhan Second Ship Design and Research Institute, Wuhan, People's Republic of China","institution_ids":["https://openalex.org/I4210129465"]}]},{"author_position":"middle","author":{"id":null,"display_name":"Shuai Xiang","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4210129465","display_name":"Wuhan Ship Development & Design Institute","ror":"https://ror.org/02mcdae06","country_code":"CN","type":"facility","lineage":["https://openalex.org/I4210129465"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Shuai Xiang","raw_affiliation_strings":["Wuhan Second Ship Design and Research Institute, Wuhan, People's Republic of China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Wuhan Second Ship Design and Research Institute, Wuhan, People's Republic of China","institution_ids":["https://openalex.org/I4210129465"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5005416297","display_name":"Yin Zhang","orcid":"https://orcid.org/0000-0002-0093-0350","observed_orcids":["https://orcid.org/0000-0002-0093-0350"]},"institutions":[{"id":"https://openalex.org/I4210129465","display_name":"Wuhan Ship Development & Design Institute","ror":"https://ror.org/02mcdae06","country_code":"CN","type":"facility","lineage":["https://openalex.org/I4210129465"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Yin Zhang","raw_affiliation_strings":["Wuhan Second Ship Design and Research Institute, Wuhan, People's Republic of China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Wuhan Second Ship Design and Research Institute, Wuhan, People's Republic of China","institution_ids":["https://openalex.org/I4210129465"]}]},{"author_position":"last","author":{"id":null,"display_name":"Jing Yang","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Jing Yang","raw_affiliation_strings":["GRG Metrology &amp; Test Group Co., Ltd, No. 8, Chuangyun Road, Shiqi Town, Panyu District, Guangzhou, People's Republic of China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"GRG Metrology &amp; Test Group Co., Ltd, No. 8, Chuangyun Road, Shiqi Town, Panyu District, Guangzhou, People's Republic of China","institution_ids":[]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.50118652,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"2025","issue":"35","first_page":"1306","last_page":"1313"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10780","display_name":"Reliability and Maintenance Optimization","score":0.9643999934196472,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10780","display_name":"Reliability and Maintenance Optimization","score":0.9643999934196472,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11941","display_name":"Power System Reliability and Maintenance","score":0.01769999973475933,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12737","display_name":"Electrical Fault Detection and Protection","score":0.00279999990016222,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/circuit-breakers","display_name":"circuit breakers","score":1.0},{"id":"https://openalex.org/keywords/disconnectors","display_name":"disconnectors","score":0.734000027179718},{"id":"https://openalex.org/keywords/failure-threshold","display_name":"failure threshold","score":0.3930000066757202},{"id":"https://openalex.org/keywords/accelerated-life-testing","display_name":"accelerated life testing","score":0.996999979019165},{"id":"https://openalex.org/keywords/electrical-protection-devices","display_name":"electrical protection devices","score":0.6639999747276306},{"id":"https://openalex.org/keywords/power-transmission-and-distribution","display_name":"power transmission and distribution","score":0.6809999942779541},{"id":"https://openalex.org/keywords/circuit-breaker-replacement","display_name":"circuit breaker replacement","score":0.48100000619888306}],"concepts":[{"id":"https://openalex.org/C61352017","wikidata":"https://www.wikidata.org/wiki/Q211058","display_name":"Circuit breaker","level":2,"score":0.9380999803543091},{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.7479000091552734},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.7376999855041504},{"id":"https://openalex.org/C173093282","wikidata":"https://www.wikidata.org/wiki/Q1228904","display_name":"Sulfur hexafluoride circuit breaker","level":5,"score":0.6963000297546387},{"id":"https://openalex.org/C123158532","wikidata":"https://www.wikidata.org/wiki/Q1128622","display_name":"Distribution board","level":3,"score":0.6381999850273132},{"id":"https://openalex.org/C141353440","wikidata":"https://www.wikidata.org/wiki/Q182221","display_name":"Fuse (electrical)","level":2,"score":0.5562999844551086},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.5063999891281128},{"id":"https://openalex.org/C66325886","wikidata":"https://www.wikidata.org/wiki/Q10860300","display_name":"Disconnector","level":3,"score":0.429500013589859},{"id":"https://openalex.org/C198352243","wikidata":"https://www.wikidata.org/wiki/Q37105","display_name":"Line (geometry)","level":2,"score":0.4251999855041504},{"id":"https://openalex.org/C15116251","wikidata":"https://www.wikidata.org/wiki/Q337716","display_name":"Residual-current device","level":3,"score":0.41760000586509705},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.41040000319480896},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.3944999873638153},{"id":"https://openalex.org/C134146338","wikidata":"https://www.wikidata.org/wiki/Q1815901","display_name":"Electronic circuit","level":2,"score":0.3880000114440918},{"id":"https://openalex.org/C157069517","wikidata":"https://www.wikidata.org/wiki/Q132172","display_name":"Arc-fault circuit interrupter","level":4,"score":0.37709999084472656},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.3671000003814697},{"id":"https://openalex.org/C158379689","wikidata":"https://www.wikidata.org/wiki/Q3533504","display_name":"Accelerated life testing","level":3,"score":0.36469998955726624},{"id":"https://openalex.org/C76231056","wikidata":"https://www.wikidata.org/wiki/Q7250838","display_name":"Prospective short circuit current","level":5,"score":0.3646000027656555},{"id":"https://openalex.org/C72047438","wikidata":"https://www.wikidata.org/wiki/Q779785","display_name":"Transient recovery voltage","level":5,"score":0.3619999885559082},{"id":"https://openalex.org/C162175671","wikidata":"https://www.wikidata.org/wiki/Q3749263","display_name":"Electrical equipment","level":2,"score":0.35370001196861267},{"id":"https://openalex.org/C31712484","wikidata":"https://www.wikidata.org/wiki/Q618740","display_name":"Recloser","level":3,"score":0.3260999917984009},{"id":"https://openalex.org/C140311924","wikidata":"https://www.wikidata.org/wiki/Q200928","display_name":"Electric power transmission","level":2,"score":0.3165999948978424},{"id":"https://openalex.org/C92018576","wikidata":"https://www.wikidata.org/wiki/Q3242194","display_name":"Power transmission","level":3,"score":0.313400000333786},{"id":"https://openalex.org/C2778309119","wikidata":"https://www.wikidata.org/wiki/Q5121614","display_name":"Circuit reliability","level":4,"score":0.3098999857902527},{"id":"https://openalex.org/C38361682","wikidata":"https://www.wikidata.org/wiki/Q1756067","display_name":"Power-system protection","level":4,"score":0.3095000088214874},{"id":"https://openalex.org/C196796808","wikidata":"https://www.wikidata.org/wiki/Q132629","display_name":"Electrical network","level":2,"score":0.301800012588501},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.2953999936580658},{"id":"https://openalex.org/C163164238","wikidata":"https://www.wikidata.org/wiki/Q2737027","display_name":"Failure rate","level":2,"score":0.27459999918937683},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.26669999957084656},{"id":"https://openalex.org/C33441834","wikidata":"https://www.wikidata.org/wiki/Q693004","display_name":"Transmission line","level":2,"score":0.2644999921321869}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1049/icp.2025.3613","doi":"https://doi.org/10.1049/icp.2025.3613","is_oa":false,"landing_page_url":"https://doi.org/10.1049/icp.2025.3613","pdf_url":null,"source":{"id":"https://openalex.org/S4404663355","display_name":"IET conference proceedings.","issn_l":"2732-4494","issn":["2732-4494"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":["jufo-1"],"host_organization":"https://openalex.org/P4310311714","host_organization_name":"Institution of Engineering and Technology","host_organization_lineage":["https://openalex.org/P4310311714"],"host_organization_lineage_names":["Institution of Engineering and Technology"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IET Conference Proceedings","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":0.6773999929428101,"id":"https://metadata.un.org/sdg/9","display_name":"Industry, innovation and infrastructure"}],"sustainable_development_goals_aurora":[],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":[],"abstract_inverted_index":{"A":[0],"circuit":[1,64,95,111],"breaker":[2,96],"serves":[3],"as":[4],"a":[5,103],"crucial":[6],"device":[7],"in":[8,47,117],"the":[9,21,72,106,123],"electrical":[10,26],"field,":[11],"facilitating":[12],"transmission":[13],"and":[14,23,32,42,51,75,88,97,113,125],"distribution":[15],"of":[16,25,79,110,127],"power":[17],"while":[18,120],"also":[19,53,121],"ensuring":[20],"protection":[22,39,115],"control":[24],"apparatus.":[27],"Failure":[28],"to":[29,36,56],"reliably":[30],"open":[31],"close":[33],"circuits":[34],"or":[35,108],"provide":[37,102],"effective":[38],"against":[40],"line":[41],"equipment":[43],"faults":[44],"can":[45],"result":[46],"significant":[48],"economic":[49],"losses":[50],"may":[52],"pose":[54],"risks":[55],"personal":[57],"safety.":[58],"Consequently,":[59],"conducting":[60],"reliability":[61,77,126],"studies":[62],"on":[63,93],"breakers":[65,112],"holds":[66],"considerable":[67],"importance.":[68],"In":[69],"this":[70],"study,":[71],"design":[73],"threshold":[74],"expected":[76],"life":[78,90],"each":[80],"product":[81],"are":[82],"determined":[83],"through":[84],"extreme":[85],"stress":[86],"assessments":[87],"accelerated":[89],"tests":[91],"conducted":[92],"one":[94],"two":[98],"disconnectors.":[99],"The":[100],"findings":[101],"reference":[104],"for":[105],"replacement":[107],"overhaul":[109],"their":[114],"devices":[116],"practical":[118],"applications,":[119],"supporting":[122],"safety":[124],"various":[128],"power-using":[129],"equipment.":[130]},"counts_by_year":[],"updated_date":"2026-10-14T16:39:01.820549","created_date":"2025-12-18T00:00:00"}