{"id":"https://openalex.org/W4417404635","doi":"https://doi.org/10.1109/ice3is66769.2025.11281052","title":"Automatic Infusion Liquid Delivery Machine Equipped with Safety Sensor","display_name":"Automatic Infusion Liquid Delivery Machine Equipped with Safety Sensor","publication_year":2025,"publication_date":"2025-08-06","ids":{"openalex":"https://openalex.org/W4417404635","doi":"https://doi.org/10.1109/ice3is66769.2025.11281052"},"language":"en","primary_location":{"id":"doi:10.1109/ice3is66769.2025.11281052","doi":"https://doi.org/10.1109/ice3is66769.2025.11281052","is_oa":false,"landing_page_url":"https://doi.org/10.1109/ice3is66769.2025.11281052","pdf_url":null,"source":{"id":"https://openalex.org/S7407086109","display_name":"International Conference on Electronic and Electrical Engineering and Intelligent System (ICE3IS)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2025 5th International Conference on Electronic and Electrical Engineering and Intelligent System (ICE3IS)","raw_type":"proceedings-article"},"volume":null,"type":"conference-paper","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":null,"display_name":"Muhammad Achsanul In\u2019am","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I226567900","display_name":"Muhammadiyah University of Yogyakarta","ror":"https://ror.org/03anrkt33","country_code":"ID","type":"education","lineage":["https://openalex.org/I226567900"]}],"countries":["ID"],"is_corresponding":false,"raw_author_name":"Muhammad Achsanul In\u2019am","raw_affiliation_strings":["Universitas Muhammadiyah Yogyakarta,Department of Medical Electronics Technology,Yogyakarta,Indonesia"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Universitas Muhammadiyah Yogyakarta,Department of Medical Electronics Technology,Yogyakarta,Indonesia","institution_ids":["https://openalex.org/I226567900"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5025518525","display_name":"Noor Pratama Apriyanto","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I226567900","display_name":"Muhammadiyah University of Yogyakarta","ror":"https://ror.org/03anrkt33","country_code":"ID","type":"education","lineage":["https://openalex.org/I226567900"]}],"countries":["ID"],"is_corresponding":false,"raw_author_name":"Noor Pratama Apriyanto","raw_affiliation_strings":["Universitas Muhammadiyah Yogyakarta,Department of Medical Electronics Technology,Yogyakarta,Indonesia"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Universitas Muhammadiyah Yogyakarta,Department of Medical Electronics Technology,Yogyakarta,Indonesia","institution_ids":["https://openalex.org/I226567900"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5080957948","display_name":"Nana Sutarna","orcid":"https://orcid.org/0000-0001-7759-7595","observed_orcids":["https://orcid.org/0000-0001-7759-7595"]},"institutions":[{"id":"https://openalex.org/I2799392579","display_name":"Jakarta State Polytechnic","ror":"https://ror.org/04v8qfb10","country_code":"ID","type":"education","lineage":["https://openalex.org/I2799392579"]}],"countries":["ID"],"is_corresponding":false,"raw_author_name":"Nana Sutarna","raw_affiliation_strings":["Politeknik Negeri Jakarta,Department of Magister Teknik Elektro Terapan,Jakarta,Indonesia"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Politeknik Negeri Jakarta,Department of Magister Teknik Elektro Terapan,Jakarta,Indonesia","institution_ids":["https://openalex.org/I2799392579"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":1.8887,"has_fulltext":false,"cited_by_count":1,"citation_normalized_percentile":{"value":0.75037394,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":91,"max":95},"biblio":{"volume":null,"issue":null,"first_page":"327","last_page":"332"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T14189","display_name":"Intravenous Infusion Technology and Safety","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T14189","display_name":"Intravenous Infusion Technology and Safety","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2204","display_name":"Biomedical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13248","display_name":"Healthcare Technology and Patient Monitoring","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2746","display_name":"Surgery"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}},{"id":"https://openalex.org/T10641","display_name":"Central Venous Catheters and Hemodialysis","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2706","display_name":"Critical Care and Intensive Care Medicine"},"field":{"id":"https://openalex.org/fields/27","display_name":"Medicine"},"domain":{"id":"https://openalex.org/domains/4","display_name":"Health Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/intravenous-infusion","display_name":"intravenous infusion","score":0.9539999961853027},{"id":"https://openalex.org/keywords/occlusion-detection","display_name":"occlusion detection","score":0.9670000076293945},{"id":"https://openalex.org/keywords/air-bubble-detection","display_name":"air bubble detection","score":0.9909999966621399},{"id":"https://openalex.org/keywords/flow-rate-accuracy","display_name":"flow rate accuracy","score":0.7570000290870667},{"id":"https://openalex.org/keywords/load-cell-sensor","display_name":"load cell sensor","score":0.8399999737739563},{"id":"https://openalex.org/keywords/optical-sensors","display_name":"optical sensors","score":0.8289999961853027},{"id":"https://openalex.org/keywords/stepper-motor","display_name":"stepper motor","score":0.7979999780654907}],"concepts":[{"id":"https://openalex.org/C2779119184","wikidata":"https://www.wikidata.org/wiki/Q294350","display_name":"ALARM","level":2,"score":0.5281999707221985},{"id":"https://openalex.org/C2776187130","wikidata":"https://www.wikidata.org/wiki/Q201035","display_name":"Infusion pump","level":2,"score":0.5266000032424927},{"id":"https://openalex.org/C134519083","wikidata":"https://www.wikidata.org/wiki/Q650921","display_name":"Peristaltic pump","level":2,"score":0.4336000084877014},{"id":"https://openalex.org/C158007255","wikidata":"https://www.wikidata.org/wiki/Q1055222","display_name":"Spectrum analyzer","level":2,"score":0.42980000376701355},{"id":"https://openalex.org/C136229726","wikidata":"https://www.wikidata.org/wiki/Q327092","display_name":"Biomedical engineering","level":1,"score":0.4081999957561493},{"id":"https://openalex.org/C44154836","wikidata":"https://www.wikidata.org/wiki/Q45045","display_name":"Simulation","level":1,"score":0.38600000739097595},{"id":"https://openalex.org/C2776268601","wikidata":"https://www.wikidata.org/wiki/Q968808","display_name":"Occlusion","level":2,"score":0.37459999322891235},{"id":"https://openalex.org/C2983812674","wikidata":"https://www.wikidata.org/wiki/Q134808","display_name":"Delivery system","level":2,"score":0.37119999527931213},{"id":"https://openalex.org/C50712719","wikidata":"https://www.wikidata.org/wiki/Q446473","display_name":"Syringe driver","level":3,"score":0.3625999987125397},{"id":"https://openalex.org/C151201525","wikidata":"https://www.wikidata.org/wiki/Q177239","display_name":"Limit (mathematics)","level":2,"score":0.3452000021934509},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.3409999907016754},{"id":"https://openalex.org/C172120300","wikidata":"https://www.wikidata.org/wiki/Q1134348","display_name":"Volumetric flow rate","level":2,"score":0.31869998574256897},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.31859999895095825},{"id":"https://openalex.org/C38349280","wikidata":"https://www.wikidata.org/wiki/Q1434290","display_name":"Flow (mathematics)","level":2,"score":0.3075999915599823},{"id":"https://openalex.org/C157915830","wikidata":"https://www.wikidata.org/wiki/Q2928001","display_name":"Bubble","level":2,"score":0.30329999327659607},{"id":"https://openalex.org/C41325743","wikidata":"https://www.wikidata.org/wiki/Q1261040","display_name":"Pressure sensor","level":2,"score":0.2849000096321106},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.27639999985694885},{"id":"https://openalex.org/C2778571141","wikidata":"https://www.wikidata.org/wiki/Q273318","display_name":"Syringe","level":2,"score":0.25040000677108765}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/ice3is66769.2025.11281052","doi":"https://doi.org/10.1109/ice3is66769.2025.11281052","is_oa":false,"landing_page_url":"https://doi.org/10.1109/ice3is66769.2025.11281052","pdf_url":null,"source":{"id":"https://openalex.org/S7407086109","display_name":"International Conference on Electronic and Electrical Engineering and Intelligent System (ICE3IS)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2025 5th International Conference on Electronic and Electrical Engineering and Intelligent System (ICE3IS)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/3","score":0.9391000270843506,"display_name":"Good health and well-being"},{"id":"https://metadata.un.org/sdg/9","score":0.5378999710083008,"display_name":"Industry, innovation and infrastructure"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":16,"referenced_works":["https://openalex.org/W4296718145","https://openalex.org/W4311453698","https://openalex.org/W4360976593","https://openalex.org/W4386893585","https://openalex.org/W4387609952","https://openalex.org/W4391917981","https://openalex.org/W4392174286","https://openalex.org/W4392193056","https://openalex.org/W4393216221","https://openalex.org/W4393999125","https://openalex.org/W4396513912","https://openalex.org/W4399633446","https://openalex.org/W4400641236","https://openalex.org/W4403294797","https://openalex.org/W4407969099","https://openalex.org/W4409819040"],"related_works":["https://openalex.org/W4220951412","https://openalex.org/W7166707369","https://openalex.org/W3006077244","https://openalex.org/W7128449521","https://openalex.org/W7163201186","https://openalex.org/W4412167612","https://openalex.org/W7161548400","https://openalex.org/W4413294204","https://openalex.org/W1979983870","https://openalex.org/W4387029088"],"abstract_inverted_index":{"Intravenous":[0],"infusion":[1,14,42,99],"remains":[2],"vital":[3],"for":[4,52,217],"delivering":[5],"fluids":[6],"and":[7,22,29,37,54,138,209],"medications":[8],"in":[9,97],"clinical":[10,218],"settings.":[11],"However,":[12],"conventional":[13],"systems":[15],"are":[16],"prone":[17],"to":[18,35,63,70,83,93,181],"flow":[19,65],"rate":[20],"inaccuracies":[21],"undetected":[23],"safety":[24,50,165,212],"issues":[25],"such":[26],"as":[27,185,187],"occlusions":[28],"air":[30,95,183],"bubbles.":[31],"This":[32],"study":[33],"aims":[34],"design":[36],"evaluate":[38],"an":[39,88,105,152],"innovative":[40],"automatic":[41],"pump":[43],"utilizing":[44],"a":[45,60],"rotary":[46],"peristaltic":[47],"mechanism":[48],"with":[49,125],"sensors":[51],"occlusion":[53,147],"bubble":[55,175],"detection.":[56],"The":[57,146,174,198],"device":[58,204],"uses":[59],"stepper":[61],"motor":[62],"regulate":[64],"rates":[66],"ranging":[67],"from":[68],"10":[69],"$50":[71],"\\mathrm{~mL}":[72,143],"/$":[73,136,144],"hour.":[74,145],"A":[75],"load":[76],"cell":[77],"sensor":[78,90],"(100":[79],"g)":[80],"is":[81,91],"integrated":[82],"detect":[84,182],"line":[85],"blockages,":[86],"while":[87],"optical":[89],"employed":[92],"identify":[94],"bubbles":[96,184],"the":[98,116,126,139,163,191,202],"line.":[100],"Flow":[101],"accuracy":[102],"testing":[103],"using":[104],"Infusion":[106],"Device":[107],"Analyzer":[108],"(IDA)":[109],"showed":[110],"all":[111],"error":[112,128],"values":[113],"were":[114],"within":[115],"$\\pm":[117],"5":[118],"\\%$":[119],"threshold":[120],"set":[121],"by":[122],"ECRI":[123],"standards,":[124],"highest":[127],"observed":[129],"at":[130,141,151],"$\\mathbf{1":[131,168],"0":[132,169],"~":[133,170],"m":[134],"L}":[135],"hour":[137],"lowest":[140],"$40":[142],"alarm":[148],"was":[149,178],"triggered":[150],"average":[153],"pressure":[154],"of":[155,167,195],"$\\mathbf{5.":[156],"7":[157],"1}":[158],"\\mathbf{P":[159],"s":[160,172],"i}$,":[161],"below":[162],"maximum":[164],"limit":[166],"P":[171],"i}$.":[173],"detection":[176],"system":[177],"sensitive":[179],"enough":[180],"small":[186],"1.2":[188],"mm,":[189],"exceeding":[190],"WHO":[192],"minimum":[193],"standard":[194],"3":[196],"mm.":[197],"results":[199],"demonstrate":[200],"that":[201],"developed":[203],"achieves":[205],"accurate":[206],"fluid":[207],"delivery":[208],"provides":[210],"effective":[211],"monitoring,":[213],"making":[214],"it":[215],"suitable":[216],"application.":[219]},"counts_by_year":[{"year":2026,"cited_by_count":1}],"updated_date":"2026-11-04T10:54:05.112534","created_date":"2025-12-16T00:00:00"}
