{"id":"https://openalex.org/W4416760653","doi":"https://doi.org/10.35833/mpce.2024.000869","title":"Optimal Capacity Configuration of Large-scale Energy Bases Considering External Multi-stochastic Scenarios and Interactive Multi-timescale Objectives","display_name":"Optimal Capacity Configuration of Large-scale Energy Bases Considering External Multi-stochastic Scenarios and Interactive Multi-timescale Objectives","publication_year":2024,"publication_date":"2024-01-01","ids":{"openalex":"https://openalex.org/W4416760653","doi":"https://doi.org/10.35833/mpce.2024.000869"},"language":"en","primary_location":{"id":"doi:10.35833/mpce.2024.000869","doi":"https://doi.org/10.35833/mpce.2024.000869","is_oa":true,"landing_page_url":"https://doi.org/10.35833/mpce.2024.000869","pdf_url":null,"source":{"id":"https://openalex.org/S4210194934","display_name":"Journal of Modern Power Systems and Clean Energy","issn_l":"2196-5420","issn":["2196-5420","2196-5625"],"is_oa":true,"is_in_doaj":true,"is_core":true,"listed_in":["cwts-core","doaj","dongbi-b","jufo-1","norway-1","oarl","poland-100","russia-white-list-1"],"host_organization":"https://openalex.org/P4310319965","host_organization_name":"Springer Nature","host_organization_lineage":["https://openalex.org/P4310319965"],"host_organization_lineage_names":["Springer Nature"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Journal of Modern Power Systems and Clean Energy","raw_type":"journal-article"},"volume":null,"type":"article","is_traditional":true,"indexed_in":["crossref","doaj"],"open_access":{"is_oa":true,"oa_status":"diamond","oa_url":"https://doi.org/10.35833/mpce.2024.000869","any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":null,"display_name":"Wang Yini","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Wang Yini","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5077347597","display_name":"Yang Hu","orcid":"https://orcid.org/0000-0002-7724-3786","observed_orcids":["https://orcid.org/0000-0002-7724-3786"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Hu Yang","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5120618037","display_name":"Zhao Yueli","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Zhao Yueli","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5100756421","display_name":"Yunzhi Li","orcid":"https://orcid.org/0000-0002-1078-2240","observed_orcids":["https://orcid.org/0000-0002-1078-2240"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Li Yunzhi","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":null,"display_name":"Fang Fang","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I153473198","display_name":"North China Electric Power University","ror":"https://ror.org/04qr5t414","country_code":"CN","type":"education","lineage":["https://openalex.org/I153473198"]},{"id":"https://openalex.org/I4391767892","display_name":"State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources","ror":"https://ror.org/045hfth47","country_code":"CN","type":"facility","lineage":["https://openalex.org/I153473198","https://openalex.org/I4391767892"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Fang Fang","raw_affiliation_strings":["School of Control and Computer Engineering, North China Electric Power University, Beijing, China","State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"School of Control and Computer Engineering, North China Electric Power University, Beijing, China","institution_ids":["https://openalex.org/I153473198"]},{"raw_affiliation_string":"State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, North China Electric Power University, Beijing, China","institution_ids":["https://openalex.org/I153473198","https://openalex.org/I4391767892"]}]},{"author_position":"last","author":{"id":null,"display_name":"Liu Jizhen","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Liu Jizhen","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.4759,"has_fulltext":false,"cited_by_count":5,"citation_normalized_percentile":{"value":0.5060573,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":98},"biblio":{"volume":"13","issue":"6","first_page":"1990","last_page":"2001"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11185","display_name":"Integrated Energy Systems Optimization","score":0.8740000128746033,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11185","display_name":"Integrated Energy Systems Optimization","score":0.8740000128746033,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10424","display_name":"Electric Power System Optimization","score":0.12479999661445618,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11007","display_name":"Hybrid Renewable Energy Systems","score":0.00039999998989515007,"subfield":{"id":"https://openalex.org/subfields/2102","display_name":"Energy Engineering and Power Technology"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/nested-optimization","display_name":"nested optimization","score":0.9670000076293945},{"id":"https://openalex.org/keywords/renewable-energy-uncertainty","display_name":"renewable energy uncertainty","score":0.6079999804496765},{"id":"https://openalex.org/keywords/wind-speed","display_name":"wind speed","score":0.5320000052452087},{"id":"https://openalex.org/keywords/solar-irradiance","display_name":"solar irradiance","score":1.0},{"id":"https://openalex.org/keywords/electric-load","display_name":"electric load","score":0.7710000276565552},{"id":"https://openalex.org/keywords/heat-load","display_name":"heat load","score":0.9890000224113464},{"id":"https://openalex.org/keywords/nonlinear-state-space-models","display_name":"nonlinear state-space models","score":0.6690000295639038}],"concepts":[{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6284999847412109},{"id":"https://openalex.org/C119701452","wikidata":"https://www.wikidata.org/wiki/Q5165881","display_name":"Control reconfiguration","level":2,"score":0.5184000134468079},{"id":"https://openalex.org/C126255220","wikidata":"https://www.wikidata.org/wiki/Q141495","display_name":"Mathematical optimization","level":1,"score":0.48899999260902405},{"id":"https://openalex.org/C78600449","wikidata":"https://www.wikidata.org/wiki/Q43302","display_name":"Wind power","level":2,"score":0.4848000109195709},{"id":"https://openalex.org/C158622935","wikidata":"https://www.wikidata.org/wiki/Q660848","display_name":"Nonlinear system","level":2,"score":0.4648999869823456},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.4602999985218048},{"id":"https://openalex.org/C186370098","wikidata":"https://www.wikidata.org/wiki/Q442787","display_name":"Energy (signal processing)","level":2,"score":0.45910000801086426},{"id":"https://openalex.org/C2780848588","wikidata":"https://www.wikidata.org/wiki/Q210494","display_name":"Power Balance","level":3,"score":0.42080000042915344},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.40709999203681946},{"id":"https://openalex.org/C137836250","wikidata":"https://www.wikidata.org/wiki/Q984063","display_name":"Optimization problem","level":2,"score":0.35350000858306885},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.3467000126838684},{"id":"https://openalex.org/C2776190866","wikidata":"https://www.wikidata.org/wiki/Q1341477","display_name":"Energy supply","level":3,"score":0.32899999618530273},{"id":"https://openalex.org/C2779438525","wikidata":"https://www.wikidata.org/wiki/Q5255048","display_name":"Demand response","level":3,"score":0.32690000534057617},{"id":"https://openalex.org/C423512","wikidata":"https://www.wikidata.org/wiki/Q383973","display_name":"Electricity generation","level":3,"score":0.32339999079704285},{"id":"https://openalex.org/C40293303","wikidata":"https://www.wikidata.org/wiki/Q27137","display_name":"Electric power","level":3,"score":0.30970001220703125},{"id":"https://openalex.org/C2039551","wikidata":"https://www.wikidata.org/wiki/Q200297","display_name":"Thermal power station","level":2,"score":0.30649998784065247},{"id":"https://openalex.org/C3020254827","wikidata":"https://www.wikidata.org/wiki/Q5255016","display_name":"Demand side","level":2,"score":0.2996000051498413},{"id":"https://openalex.org/C2777423268","wikidata":"https://www.wikidata.org/wiki/Q3663116","display_name":"Energy balance","level":2,"score":0.2922999858856201},{"id":"https://openalex.org/C120330832","wikidata":"https://www.wikidata.org/wiki/Q166656","display_name":"Supply and demand","level":2,"score":0.2849000096321106},{"id":"https://openalex.org/C42475967","wikidata":"https://www.wikidata.org/wiki/Q194292","display_name":"Operations research","level":1,"score":0.2703000009059906},{"id":"https://openalex.org/C2779370713","wikidata":"https://www.wikidata.org/wiki/Q357554","display_name":"Load management","level":2,"score":0.2685000002384186},{"id":"https://openalex.org/C115527620","wikidata":"https://www.wikidata.org/wiki/Q769909","display_name":"Nonlinear programming","level":3,"score":0.2676999866962433},{"id":"https://openalex.org/C2776469763","wikidata":"https://www.wikidata.org/wiki/Q5034491","display_name":"Capacity optimization","level":3,"score":0.25929999351501465},{"id":"https://openalex.org/C2742236","wikidata":"https://www.wikidata.org/wiki/Q924713","display_name":"Efficient energy use","level":2,"score":0.25920000672340393},{"id":"https://openalex.org/C73916439","wikidata":"https://www.wikidata.org/wiki/Q837718","display_name":"Energy storage","level":3,"score":0.2540999948978424},{"id":"https://openalex.org/C186394612","wikidata":"https://www.wikidata.org/wiki/Q7098942","display_name":"Optimal design","level":2,"score":0.2517000138759613},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.2506999969482422}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.35833/mpce.2024.000869","doi":"https://doi.org/10.35833/mpce.2024.000869","is_oa":true,"landing_page_url":"https://doi.org/10.35833/mpce.2024.000869","pdf_url":null,"source":{"id":"https://openalex.org/S4210194934","display_name":"Journal of Modern Power Systems and Clean Energy","issn_l":"2196-5420","issn":["2196-5420","2196-5625"],"is_oa":true,"is_in_doaj":true,"is_core":true,"listed_in":["cwts-core","doaj","dongbi-b","jufo-1","norway-1","oarl","poland-100","russia-white-list-1"],"host_organization":"https://openalex.org/P4310319965","host_organization_name":"Springer Nature","host_organization_lineage":["https://openalex.org/P4310319965"],"host_organization_lineage_names":["Springer Nature"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Journal of Modern Power Systems and Clean Energy","raw_type":"journal-article"}],"best_oa_location":{"id":"doi:10.35833/mpce.2024.000869","doi":"https://doi.org/10.35833/mpce.2024.000869","is_oa":true,"landing_page_url":"https://doi.org/10.35833/mpce.2024.000869","pdf_url":null,"source":{"id":"https://openalex.org/S4210194934","display_name":"Journal of Modern Power Systems and Clean Energy","issn_l":"2196-5420","issn":["2196-5420","2196-5625"],"is_oa":true,"is_in_doaj":true,"is_core":true,"listed_in":["cwts-core","doaj","dongbi-b","jufo-1","norway-1","oarl","poland-100","russia-white-list-1"],"host_organization":"https://openalex.org/P4310319965","host_organization_name":"Springer Nature","host_organization_lineage":["https://openalex.org/P4310319965"],"host_organization_lineage_names":["Springer Nature"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Journal of Modern Power Systems and Clean Energy","raw_type":"journal-article"},"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/7","score":1.0,"display_name":"Affordable and clean energy"},{"id":"https://metadata.un.org/sdg/9","score":0.8970999717712402,"display_name":"Industry, innovation and infrastructure"},{"id":"https://metadata.un.org/sdg/13","score":0.685699999332428,"display_name":"Climate action"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":["https://openalex.org/W7130583876","https://openalex.org/W4417250560","https://openalex.org/W7155691987","https://openalex.org/W4413265684","https://openalex.org/W4415464473","https://openalex.org/W7125134113","https://openalex.org/W7138944981","https://openalex.org/W7117837475","https://openalex.org/W4393852182","https://openalex.org/W7124988032"],"abstract_inverted_index":{"Optimal":[0],"capacity":[1],"configuration":[2],"(OCC)":[3],"of":[4,26,53,126,168],"large-scale":[5,27,56,128],"energy":[6,28,57,129],"bases":[7,29],"with":[8],"multi-timescale":[9,36,62],"operation":[10],"characteristics":[11],"presents":[12],"a":[13,54,70,97],"critical":[14],"challenge.":[15],"To":[16],"address":[17],"the":[18,41,44,78,84,124,127,134,144,152,159,166,169],"problem,":[19],"this":[20],"study":[21],"proposes":[22],"an":[23],"OCC":[24,125,171],"approach":[25],"considering":[30,77],"external":[31,79],"multi-stochastic":[32,80],"scenarios":[33,81,107],"and":[34,66,94,108,118,149,158],"interactive":[35,61],"objectives.":[37],"Firstly,":[38],"guided":[39],"by":[40,83,110],"system":[42],"theory,":[43],"nonlinear":[45],"state-space":[46],"description":[47],"is":[48,74,101,138],"presented":[49],"for":[50],"systematic":[51],"analysis":[52],"general":[55],"base.":[58,130],"Due":[59],"to":[60],"objectives":[63],"between":[64,146,154],"annual":[65],"daily":[67],"cumulative":[68],"objectives,":[69],"nested":[71,119,135],"optimization":[72,99,116,120,136],"structure":[73,121,137],"established.":[75],"Then,":[76],"caused":[82],"variables":[85],"such":[86],"as":[87],"wind":[88],"speed,":[89],"solar":[90],"irradiance,":[91],"electric":[92,155],"load,":[93,96],"thermal":[95,147],"multi-step":[98,115],"strategy":[100,117],"proposed":[102,170],"including":[103],"pre-configuration":[104],"in":[105],"regular":[106],"reconfiguration":[109],"introducing":[111],"micro-incremental":[112],"scenarios.":[113],"The":[114],"jointly":[122],"achieve":[123],"In":[131],"each":[132],"step,":[133],"executed":[139],"once.":[140],"Finally,":[141],"while":[142],"ensuring":[143],"balance":[145],"supply":[148,157],"load":[150,160],"demand,":[151],"imbalances":[153],"power":[156],"demand":[161],"are":[162],"eliminated,":[163],"significantly":[164],"showing":[165],"efficiency":[167],"approach.":[172]},"counts_by_year":[{"year":2026,"cited_by_count":4},{"year":2025,"cited_by_count":1}],"updated_date":"2026-11-04T10:54:05.112534","created_date":"2025-11-28T00:00:00"}
