{"id":"https://openalex.org/W4416136331","doi":"https://doi.org/10.1109/pesgm52009.2025.11225567","title":"Pilot Protection Scheme Selection Guide for Transmission Lines Near Inverter-Based Resources","display_name":"Pilot Protection Scheme Selection Guide for Transmission Lines Near Inverter-Based Resources","publication_year":2025,"publication_date":"2025-07-27","ids":{"openalex":"https://openalex.org/W4416136331","doi":"https://doi.org/10.1109/pesgm52009.2025.11225567"},"language":"en","primary_location":{"id":"doi:10.1109/pesgm52009.2025.11225567","doi":"https://doi.org/10.1109/pesgm52009.2025.11225567","is_oa":false,"landing_page_url":"https://doi.org/10.1109/pesgm52009.2025.11225567","pdf_url":null,"source":{"id":"https://openalex.org/S4210212590","display_name":"IEEE Power Engineering Society General Meeting","issn_l":"1932-5517","issn":["1932-5517","2693-7891"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core"],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2025 IEEE Power &amp;amp; Energy Society General Meeting (PESGM)","raw_type":"proceedings-article"},"volume":null,"type":"conference-paper","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5079505535","display_name":"Manish Patel","orcid":"https://orcid.org/0000-0002-4403-4750","observed_orcids":["https://orcid.org/0000-0002-4403-4750"]},"institutions":[{"id":"https://openalex.org/I1335486098","display_name":"Electric Power Research Institute","ror":"https://ror.org/02dqztz06","country_code":"US","type":"nonprofit","lineage":["https://openalex.org/I1335486098"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Manish Patel","raw_affiliation_strings":["Electric Power Research Institute"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Electric Power Research Institute","institution_ids":["https://openalex.org/I1335486098"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5081346754","display_name":"Wes Baker","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Wes Baker","raw_affiliation_strings":["Silicon Ranch Corporation"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Silicon Ranch Corporation","institution_ids":[]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5083570102","display_name":"Ritwik Chowdhury","orcid":"https://orcid.org/0000-0001-8413-9840","observed_orcids":["https://orcid.org/0000-0001-8413-9840"]},"institutions":[{"id":"https://openalex.org/I4405273072","display_name":"Schweitzer Engineering Laboratories (United States)","ror":"https://ror.org/057yrm276","country_code":"US","type":"company","lineage":["https://openalex.org/I4405273072"]}],"countries":["US"],"is_corresponding":false,"raw_author_name":"Ritwik Chowdhury","raw_affiliation_strings":["Schweitzer Engineering Laboratories, Inc"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Schweitzer Engineering Laboratories, Inc","institution_ids":["https://openalex.org/I4405273072"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.0,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"5"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.00019999999494757503,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13183","display_name":"Islanding Detection in Power Systems","score":9.999999747378752e-05,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/pilot-protection","display_name":"pilot protection","score":0.7829999923706055},{"id":"https://openalex.org/keywords/transmission-lines","display_name":"transmission lines","score":0.7540000081062317},{"id":"https://openalex.org/keywords/inverter-based-resources","display_name":"inverter-based resources","score":0.9990000128746033},{"id":"https://openalex.org/keywords/fault-current-characteristics","display_name":"fault current characteristics","score":0.9200000166893005},{"id":"https://openalex.org/keywords/grid-codes","display_name":"grid codes","score":0.5910000205039978},{"id":"https://openalex.org/keywords/power-system-protection","display_name":"power system protection","score":0.5640000104904175}],"concepts":[{"id":"https://openalex.org/C188087704","wikidata":"https://www.wikidata.org/wiki/Q369577","display_name":"Standardization","level":2,"score":0.6510000228881836},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.6229000091552734},{"id":"https://openalex.org/C140311924","wikidata":"https://www.wikidata.org/wiki/Q200928","display_name":"Electric power transmission","level":2,"score":0.6122999787330627},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.5920000076293945},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.5444999933242798},{"id":"https://openalex.org/C77618280","wikidata":"https://www.wikidata.org/wiki/Q1155772","display_name":"Scheme (mathematics)","level":2,"score":0.5418999791145325},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.5364999771118164},{"id":"https://openalex.org/C123745756","wikidata":"https://www.wikidata.org/wiki/Q1665949","display_name":"Interconnection","level":2,"score":0.48750001192092896},{"id":"https://openalex.org/C26517878","wikidata":"https://www.wikidata.org/wiki/Q228039","display_name":"Key (lock)","level":2,"score":0.445499986410141},{"id":"https://openalex.org/C761482","wikidata":"https://www.wikidata.org/wiki/Q118093","display_name":"Transmission (telecommunications)","level":2,"score":0.43459999561309814},{"id":"https://openalex.org/C192209626","wikidata":"https://www.wikidata.org/wiki/Q190909","display_name":"Focus (optics)","level":2,"score":0.38359999656677246},{"id":"https://openalex.org/C81917197","wikidata":"https://www.wikidata.org/wiki/Q628760","display_name":"Selection (genetic algorithm)","level":2,"score":0.38029998540878296},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.3555000126361847},{"id":"https://openalex.org/C38361682","wikidata":"https://www.wikidata.org/wiki/Q1756067","display_name":"Power-system protection","level":4,"score":0.34709998965263367},{"id":"https://openalex.org/C201995342","wikidata":"https://www.wikidata.org/wiki/Q682496","display_name":"Systems engineering","level":1,"score":0.3019999861717224},{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.2838999927043915},{"id":"https://openalex.org/C2983254600","wikidata":"https://www.wikidata.org/wiki/Q1096907","display_name":"Power grid","level":3,"score":0.2662999927997589},{"id":"https://openalex.org/C2779553522","wikidata":"https://www.wikidata.org/wiki/Q15261121","display_name":"National Grid","level":3,"score":0.2556000053882599},{"id":"https://openalex.org/C112930515","wikidata":"https://www.wikidata.org/wiki/Q4389547","display_name":"Risk analysis (engineering)","level":1,"score":0.25200000405311584}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/pesgm52009.2025.11225567","doi":"https://doi.org/10.1109/pesgm52009.2025.11225567","is_oa":false,"landing_page_url":"https://doi.org/10.1109/pesgm52009.2025.11225567","pdf_url":null,"source":{"id":"https://openalex.org/S4210212590","display_name":"IEEE Power Engineering Society General Meeting","issn_l":"1932-5517","issn":["1932-5517","2693-7891"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core"],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2025 IEEE Power &amp;amp; Energy Society General Meeting (PESGM)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":1.0,"id":"https://metadata.un.org/sdg/9","display_name":"Industry, innovation and infrastructure"},{"score":0.5690000057220459,"id":"https://metadata.un.org/sdg/7","display_name":"Affordable and clean energy"}],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":6,"referenced_works":["https://openalex.org/W2021768843","https://openalex.org/W3003877412","https://openalex.org/W3082331475","https://openalex.org/W3094276330","https://openalex.org/W4387005936","https://openalex.org/W4391759509"],"related_works":["https://openalex.org/W4404180321","https://openalex.org/W4409842844","https://openalex.org/W7127344149","https://openalex.org/W4321637099","https://openalex.org/W6903412936","https://openalex.org/W7166527362","https://openalex.org/W4410771175","https://openalex.org/W3130792830","https://openalex.org/W4403286557","https://openalex.org/W4387005536"],"abstract_inverted_index":{"The":[0,54,79],"interconnection":[1,24],"of":[2,34,64,81],"inverter-based":[3],"resources":[4],"(IBRs)":[5],"to":[6,20,112,132],"the":[7,13,23,32,42,46,96],"grid":[8,93,124],"has":[9,86],"grown":[10],"significantly":[11],"over":[12],"last":[14],"few":[15],"years":[16],"and":[17,52,67,126],"is":[18,29,49],"expected":[19],"continue.":[21],"During":[22],"process,":[25],"a":[26,37,88],"protection":[27,39,133,139],"engineer":[28],"faced":[30],"with":[31],"challenge":[33,58],"properly":[35],"selecting":[36,136],"pilot":[38,138],"scheme":[40],"for":[41,56,91,108,141],"transmission":[43,142],"lines":[44,143],"near":[45,144],"IBRs":[47,66,72],"that":[48,115],"secure,":[50],"dependable,":[51],"economical.":[53],"reasons":[55],"this":[57],"include":[59],"non-standardized":[60],"fault":[61,83,118],"current":[62,84],"characteristics":[63],"legacy":[65],"difficulty":[68],"in":[69,73,122,135],"accurately":[70],"modeling":[71,77],"traditional":[74],"phasor-domain":[75],"short-circuit":[76],"platforms.":[78],"standardization":[80],"IBR\u2019s":[82],"characteristic":[85],"been":[87],"key":[89],"focus":[90],"many":[92],"codes":[94,125],"around":[95],"world.":[97],"For":[98],"example,":[99],"IEEE":[100],"Std":[101],"2800-2022.":[102],"However,":[103],"it":[104],"may":[105],"take":[106],"time":[107],"all":[109],"IBR":[110],"manufacturers":[111],"develop":[113],"equipment":[114],"can":[116],"produce":[117],"currents":[119],"as":[120],"specified":[121],"various":[123],"standards.":[127],"This":[128],"paper":[129],"provides":[130],"guidance":[131],"engineers":[134],"appropriate":[137],"schemes":[140],"IBRs.":[145]},"counts_by_year":[],"updated_date":"2026-10-28T10:33:24.094632","created_date":"2025-11-10T00:00:00"}