{"id":"https://openalex.org/W4416045512","doi":"https://doi.org/10.11591/ijece.v15i6.pp5106-5118","title":"SGcoSim: a co-simulation framework to explore smart grid applications","display_name":"SGcoSim: a co-simulation framework to explore smart grid applications","alternate_titles":[],"publication_year":2025,"publication_date":"2025-12-01","ids":{"openalex":"https://openalex.org/W4416045512","doi":"https://doi.org/10.11591/ijece.v15i6.pp5106-5118"},"language":"en","primary_location":{"id":"doi:10.11591/ijece.v15i6.pp5106-5118","doi":"https://doi.org/10.11591/ijece.v15i6.pp5106-5118","is_oa":true,"landing_page_url":"https://doi.org/10.11591/ijece.v15i6.pp5106-5118","pdf_url":"https://ijece.iaescore.com/index.php/IJECE/article/download/37620/18502","source":{"id":"https://openalex.org/S4210235676","display_name":"International Journal of Power Electronics and Drive Systems/International Journal of Electrical and Computer Engineering","issn_l":"2722-256X","issn":["2722-256X","2722-2578"],"is_oa":true,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","jufo-1"],"host_organization":"https://openalex.org/P4310315009","host_organization_name":"Institute of Advanced Engineering and Science (IAES)","host_organization_lineage":["https://openalex.org/P4310315009"],"host_organization_lineage_names":["Institute of Advanced Engineering and Science (IAES)"],"type":"journal"},"license":"cc-by-sa","license_id":"https://openalex.org/licenses/cc-by-sa","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"International Journal of Electrical and Computer Engineering (IJECE)","raw_type":"journal-article"},"parent_works":[],"lineage":["https://openalex.org/W4416045512"],"child_works_count":0,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":true,"oa_status":"diamond","oa_url":"https://ijece.iaescore.com/index.php/IJECE/article/download/37620/18502","any_repository_has_fulltext":true},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5061450417","display_name":"Abdalkarim Awad","orcid":"https://orcid.org/0000-0002-8266-4198","observed_orcids":["https://orcid.org/0000-0002-8266-4198"]},"institutions":[{"id":"https://openalex.org/I94800806","display_name":"Birzeit University","ror":"https://ror.org/0256kw398","country_code":"PS","type":"education","lineage":["https://openalex.org/I94800806"]}],"countries":["PS"],"is_corresponding":true,"contributor_roles":[],"raw_author_name":"Abdalkarim Awad","raw_affiliation_strings":["Birzeit University"],"raw_orcid":"https://orcid.org/0000-0002-8266-4198","affiliations":[{"raw_affiliation_string":"Birzeit University","institution_ids":["https://openalex.org/I94800806"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5063445290","display_name":"Abdallatif S. Abu-Issa","orcid":"https://orcid.org/0000-0002-7030-4734","observed_orcids":["https://orcid.org/0000-0002-7030-4734"]},"institutions":[{"id":"https://openalex.org/I94800806","display_name":"Birzeit University","ror":"https://ror.org/0256kw398","country_code":"PS","type":"education","lineage":["https://openalex.org/I94800806"]}],"countries":["PS"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"Abdallatif Abu-Issa","raw_affiliation_strings":["Birzeit University"],"raw_orcid":"https://orcid.org/0000-0002-7030-4734","affiliations":[{"raw_affiliation_string":"Birzeit University","institution_ids":["https://openalex.org/I94800806"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5108237283","display_name":"Peter Bazan","orcid":"https://orcid.org/0000-0002-4731-5224","observed_orcids":["https://orcid.org/0000-0002-4731-5224"]},"institutions":[{"id":"https://openalex.org/I181369854","display_name":"Friedrich-Alexander-Universit\u00e4t Erlangen-N\u00fcrnberg","ror":"https://ror.org/00f7hpc57","country_code":"DE","type":"education","lineage":["https://openalex.org/I181369854"]}],"countries":["DE"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"Peter Bazan","raw_affiliation_strings":["University of Erlangen"],"raw_orcid":"https://orcid.org/0000-0002-4731-5224","affiliations":[{"raw_affiliation_string":"University of Erlangen","institution_ids":["https://openalex.org/I181369854"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5102836787","display_name":"Reinhard German","orcid":"https://orcid.org/0000-0002-9071-4802","observed_orcids":["https://orcid.org/0000-0002-9071-4802"]},"institutions":[{"id":"https://openalex.org/I181369854","display_name":"Friedrich-Alexander-Universit\u00e4t Erlangen-N\u00fcrnberg","ror":"https://ror.org/00f7hpc57","country_code":"DE","type":"education","lineage":["https://openalex.org/I181369854"]}],"countries":["DE"],"is_corresponding":false,"contributor_roles":[],"raw_author_name":"Reinhard German","raw_affiliation_strings":["University of Erlangen"],"raw_orcid":"https://orcid.org/0000-0002-9071-4802","affiliations":[{"raw_affiliation_string":"University of Erlangen","institution_ids":["https://openalex.org/I181369854"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":2,"corresponding_author_ids":["https://openalex.org/A5061450417"],"corresponding_institution_ids":["https://openalex.org/I94800806"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":true,"cited_by_count":0,"reviewed_by_count":0,"citation_normalized_percentile":{"value":0.0,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"15","issue":"6","first_page":"5106","last_page":"5106"},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T12451","display_name":"Smart Grid and Power Systems","score":0.6000999808311462,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T12451","display_name":"Smart Grid and Power Systems","score":0.6000999808311462,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14276","display_name":"Power Systems and Technologies","score":0.15530000627040863,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.0722000002861023,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/smart-grid","display_name":"smart grid","score":0.8579999804496765},{"id":"https://openalex.org/keywords/power-system-modeling","display_name":"power system modeling","score":0.8109999895095825},{"id":"https://openalex.org/keywords/opendss","display_name":"OpenDSS","score":0.7929999828338623},{"id":"https://openalex.org/keywords/omnet","display_name":"OMNeT++","score":0.9959999918937683},{"id":"https://openalex.org/keywords/wireless-sensor-networks","display_name":"wireless sensor networks","score":0.9890000224113464},{"id":"https://openalex.org/keywords/phasor-measurement-units","display_name":"phasor measurement units","score":0.7990000247955322},{"id":"https://openalex.org/keywords/wide-area-monitoring","display_name":"wide-area monitoring","score":0.9190000295639038},{"id":"https://openalex.org/keywords/volt-var-optimization","display_name":"volt/var optimization","score":0.9649999737739563},{"id":"https://openalex.org/keywords/demand-response","display_name":"demand response","score":0.9769999980926514},{"id":"https://openalex.org/keywords/power-losses","display_name":"power losses","score":0.49399998784065247},{"id":"https://openalex.org/keywords/energy-consumption","display_name":"energy consumption","score":0.968999981880188}],"concepts":[{"id":"https://openalex.org/C10558101","wikidata":"https://www.wikidata.org/wiki/Q689855","display_name":"Smart grid","level":2,"score":0.8314999938011169},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.5692999958992004},{"id":"https://openalex.org/C2778229166","wikidata":"https://www.wikidata.org/wiki/Q8290","display_name":"Phasor measurement unit","level":5,"score":0.5159000158309937},{"id":"https://openalex.org/C120314980","wikidata":"https://www.wikidata.org/wiki/Q180634","display_name":"Distributed computing","level":1,"score":0.5127999782562256},{"id":"https://openalex.org/C149635348","wikidata":"https://www.wikidata.org/wiki/Q193040","display_name":"Embedded system","level":1,"score":0.4666000008583069},{"id":"https://openalex.org/C2779438525","wikidata":"https://www.wikidata.org/wiki/Q5255048","display_name":"Demand response","level":3,"score":0.4507000148296356},{"id":"https://openalex.org/C2780165032","wikidata":"https://www.wikidata.org/wiki/Q16869822","display_name":"Energy consumption","level":2,"score":0.43709999322891235},{"id":"https://openalex.org/C24590314","wikidata":"https://www.wikidata.org/wiki/Q336038","display_name":"Wireless sensor network","level":2,"score":0.4345000088214874},{"id":"https://openalex.org/C555944384","wikidata":"https://www.wikidata.org/wiki/Q249","display_name":"Wireless","level":2,"score":0.41670000553131104},{"id":"https://openalex.org/C9652623","wikidata":"https://www.wikidata.org/wiki/Q190109","display_name":"Field (mathematics)","level":2,"score":0.4147999882698059},{"id":"https://openalex.org/C31258907","wikidata":"https://www.wikidata.org/wiki/Q1301371","display_name":"Computer network","level":1,"score":0.3968000113964081},{"id":"https://openalex.org/C12269588","wikidata":"https://www.wikidata.org/wiki/Q132364","display_name":"Communications protocol","level":2,"score":0.3896999955177307},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.37929999828338623},{"id":"https://openalex.org/C7817414","wikidata":"https://www.wikidata.org/wiki/Q1779504","display_name":"Energy management","level":3,"score":0.3741999864578247},{"id":"https://openalex.org/C544738498","wikidata":"https://www.wikidata.org/wiki/Q861135","display_name":"Distributed generation","level":3,"score":0.35440000891685486},{"id":"https://openalex.org/C79403827","wikidata":"https://www.wikidata.org/wiki/Q3988","display_name":"Real-time computing","level":1,"score":0.34040001034736633},{"id":"https://openalex.org/C2742236","wikidata":"https://www.wikidata.org/wiki/Q924713","display_name":"Efficient energy use","level":2,"score":0.3402999937534332},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.3393999934196472},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.3384999930858612},{"id":"https://openalex.org/C26517878","wikidata":"https://www.wikidata.org/wiki/Q228039","display_name":"Key (lock)","level":2,"score":0.33739998936653137},{"id":"https://openalex.org/C192126672","wikidata":"https://www.wikidata.org/wiki/Q1068715","display_name":"Telecommunications network","level":2,"score":0.3158000111579895},{"id":"https://openalex.org/C104954878","wikidata":"https://www.wikidata.org/wiki/Q1648707","display_name":"Routing protocol","level":3,"score":0.31049999594688416},{"id":"https://openalex.org/C2780385302","wikidata":"https://www.wikidata.org/wiki/Q367158","display_name":"Protocol (science)","level":3,"score":0.30169999599456787},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.28760001063346863},{"id":"https://openalex.org/C2779510800","wikidata":"https://www.wikidata.org/wiki/Q1630602","display_name":"Smart meter","level":3,"score":0.28690001368522644},{"id":"https://openalex.org/C74172769","wikidata":"https://www.wikidata.org/wiki/Q1446839","display_name":"Routing (electronic design automation)","level":2,"score":0.2824999988079071},{"id":"https://openalex.org/C45872418","wikidata":"https://www.wikidata.org/wiki/Q5318966","display_name":"Dynamic demand","level":3,"score":0.2720000147819519},{"id":"https://openalex.org/C62066863","wikidata":"https://www.wikidata.org/wiki/Q5283196","display_name":"Distribution management system","level":2,"score":0.2718000113964081},{"id":"https://openalex.org/C2778774385","wikidata":"https://www.wikidata.org/wiki/Q4437810","display_name":"Power management","level":3,"score":0.2678999900817871},{"id":"https://openalex.org/C2781260460","wikidata":"https://www.wikidata.org/wiki/Q6139999","display_name":"Energy management system","level":4,"score":0.26109999418258667}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.11591/ijece.v15i6.pp5106-5118","doi":"https://doi.org/10.11591/ijece.v15i6.pp5106-5118","is_oa":true,"landing_page_url":"https://doi.org/10.11591/ijece.v15i6.pp5106-5118","pdf_url":"https://ijece.iaescore.com/index.php/IJECE/article/download/37620/18502","source":{"id":"https://openalex.org/S4210235676","display_name":"International Journal of Power Electronics and Drive Systems/International Journal of Electrical and Computer Engineering","issn_l":"2722-256X","issn":["2722-256X","2722-2578"],"is_oa":true,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","jufo-1"],"host_organization":"https://openalex.org/P4310315009","host_organization_name":"Institute of Advanced Engineering and Science (IAES)","host_organization_lineage":["https://openalex.org/P4310315009"],"host_organization_lineage_names":["Institute of Advanced Engineering and Science (IAES)"],"type":"journal"},"license":"cc-by-sa","license_id":"https://openalex.org/licenses/cc-by-sa","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"International Journal of Electrical and Computer Engineering (IJECE)","raw_type":"journal-article"},{"id":"pmh:oai:zenodo.org:18194530","doi":null,"is_oa":true,"landing_page_url":"https://zenodo.org/records/18194530","pdf_url":null,"source":{"id":"https://openalex.org/S4306400562","display_name":"Zenodo (CERN European Organization for Nuclear Research)","issn_l":null,"issn":null,"is_oa":true,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I67311998","host_organization_name":"European Organization for Nuclear Research","host_organization_lineage":["https://openalex.org/I67311998"],"host_organization_lineage_names":[],"type":"repository"},"license":"cc-by","license_id":"https://openalex.org/licenses/cc-by","version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":"International Journal of Electrical and Computer Engineering (IJECE), 15(6), 5106-5118, (2025-12-01)","raw_type":"info:eu-repo/semantics/article"}],"best_oa_location":{"id":"doi:10.11591/ijece.v15i6.pp5106-5118","doi":"https://doi.org/10.11591/ijece.v15i6.pp5106-5118","is_oa":true,"landing_page_url":"https://doi.org/10.11591/ijece.v15i6.pp5106-5118","pdf_url":"https://ijece.iaescore.com/index.php/IJECE/article/download/37620/18502","source":{"id":"https://openalex.org/S4210235676","display_name":"International Journal of Power Electronics and Drive Systems/International Journal of Electrical and Computer Engineering","issn_l":"2722-256X","issn":["2722-256X","2722-2578"],"is_oa":true,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","jufo-1"],"host_organization":"https://openalex.org/P4310315009","host_organization_name":"Institute of Advanced Engineering and Science (IAES)","host_organization_lineage":["https://openalex.org/P4310315009"],"host_organization_lineage_names":["Institute of Advanced Engineering and Science (IAES)"],"type":"journal"},"license":"cc-by-sa","license_id":"https://openalex.org/licenses/cc-by-sa","version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"International Journal of Electrical and Computer Engineering (IJECE)","raw_type":"journal-article"},"sustainable_development_goals":[{"score":1.0,"display_name":"Industry, innovation and infrastructure","id":"https://metadata.un.org/sdg/9"},{"score":0.9853000044822693,"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7"}],"study_designs":[],"awards":[],"funders":[{"id":"https://openalex.org/F4320321114","display_name":"Bundesministerium f\u00fcr Bildung und Forschung","ror":"https://ror.org/04pz7b180"}],"has_content":{"grobid_xml":true,"pdf":true},"content_urls":{"pdf":"https://content.openalex.org/works/W4416045512.pdf","grobid_xml":"https://content.openalex.org/works/W4416045512.grobid-xml"},"referenced_works_count":12,"referenced_works":["https://openalex.org/W48581462","https://openalex.org/W1976113428","https://openalex.org/W2000044792","https://openalex.org/W2111024380","https://openalex.org/W2228951790","https://openalex.org/W2478117052","https://openalex.org/W2536120915","https://openalex.org/W4247139473","https://openalex.org/W4399569951","https://openalex.org/W4403094451","https://openalex.org/W4403759044","https://openalex.org/W4404480002"],"related_works":["https://openalex.org/W1632156163","https://openalex.org/W2504588992","https://openalex.org/W2076516309","https://openalex.org/W2041072771","https://openalex.org/W4404740241","https://openalex.org/W2089724321","https://openalex.org/W2782558310","https://openalex.org/W2182182850","https://openalex.org/W2112172165","https://openalex.org/W48581462"],"abstract_inverted_index":{"Under":[0],"the":[1,22,85,126],"smart":[2,45],"grid":[3,24,46],"concept,":[4],"new":[5],"novel":[6],"applications":[7,11],"are":[8],"emerging.":[9],"These":[10],"make":[12],"use":[13],"of":[14,128],"information":[15],"and":[16,40,57,81,105,122],"communication":[17,42,60],"technology":[18],"(ICT)":[19],"to":[20,43],"help":[21],"electrical":[23],"run":[25],"more":[26],"smoothly.":[27],"This":[28],"paper":[29],"introduces":[30],"SGcoSim,":[31],"a":[32,97],"co-simulation":[33],"framework":[34,49],"that":[35],"integrates":[36],"power":[37,54,123],"system":[38,104],"modeling":[39],"data":[41,82],"enhance":[44],"applications.":[47],"The":[48],"utilizes":[50],"OpenDSS":[51],"for":[52,59,78],"simulating":[53],"distribution":[55],"components":[56],"OMNeT++":[58],"modeling,":[61],"enabling":[62],"real-time":[63],"peer-to-peer":[64],"interactions":[65],"via":[66],"wireless":[67],"sensor":[68],"network":[69],"(WSN)":[70],"techniques.":[71],"Virtual":[72],"cord":[73],"protocol":[74],"(VCP)":[75],"is":[76,91],"deployed":[77],"efficient":[79],"routing":[80],"management":[83],"within":[84],"field":[86],"area":[87],"network.":[88],"SGcoSim\u2019s":[89],"functionality":[90],"demonstrated":[92],"through":[93],"two":[94],"case":[95],"studies:":[96],"phasor":[98],"measurement":[99],"unit":[100],"(PMU)-based":[101],"wide-area":[102],"monitoring":[103],"an":[106],"integrated":[107],"volt/VAR":[108],"optimization":[109],"with":[110],"demand":[111],"response":[112],"(IVVO-DR)":[113],"application.":[114],"Results":[115],"indicate":[116],"significant":[117],"reductions":[118],"in":[119],"energy":[120],"consumption":[121],"losses,":[124],"highlighting":[125],"capabilities":[127],"SGcoSim.":[129]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W4416045512","counts_by_year":[],"updated_date":"2026-11-20T13:11:24.684918","created_date":"2025-11-08T00:00:00"}
