{"id":"https://openalex.org/W4415744758","doi":"https://doi.org/10.1109/icees67011.2025.11212938","title":"Condition Monitoring of Induction Motors Using Hilbert and Fourier Transforms","display_name":"Condition Monitoring of Induction Motors Using Hilbert and Fourier Transforms","alternate_titles":[],"publication_year":2025,"publication_date":"2025-08-21","ids":{"openalex":"https://openalex.org/W4415744758","doi":"https://doi.org/10.1109/icees67011.2025.11212938"},"language":"en","primary_location":{"id":"doi:10.1109/icees67011.2025.11212938","doi":"https://doi.org/10.1109/icees67011.2025.11212938","is_oa":false,"landing_page_url":"https://doi.org/10.1109/icees67011.2025.11212938","pdf_url":null,"source":{"id":"https://openalex.org/S7407086565","display_name":"International Conference on Electrical Energy Systems (ICEES)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2025 11th International Conference on Electrical Energy Systems (ICEES)","raw_type":"proceedings-article"},"parent_works":[],"lineage":["https://openalex.org/W4415744758"],"child_works_count":0,"type":"conference-paper","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5120207207","display_name":"Elsa Allard","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Elsa Allard","raw_affiliation_strings":["Polytech Dijon,Department of Electronics,Dijon,France"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Polytech Dijon,Department of Electronics,Dijon,France","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5095927583","display_name":"Kishore Bingi","orcid":"https://orcid.org/0000-0001-7333-7438","observed_orcids":["https://orcid.org/0000-0001-7333-7438","https://orcid.org/0000-0002-1039-4707"]},"institutions":[{"id":"https://openalex.org/I203899302","display_name":"Universiti Teknologi Petronas","ror":"https://ror.org/048g2sh07","country_code":"MY","type":"education","lineage":["https://openalex.org/I203899302"]}],"countries":["MY"],"is_corresponding":false,"raw_author_name":"Kishore Bingi","raw_affiliation_strings":["Universiti Teknologi PETRONAS,Department of Electrical and Electronics Engineering,Seri Iskandar,Malaysia"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Universiti Teknologi PETRONAS,Department of Electrical and Electronics Engineering,Seri Iskandar,Malaysia","institution_ids":["https://openalex.org/I203899302"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5083195984","display_name":"P. Arun Mozhi Devan","orcid":"https://orcid.org/0000-0003-0231-5113","observed_orcids":["https://orcid.org/0000-0003-0231-5113"]},"institutions":[{"id":"https://openalex.org/I203899302","display_name":"Universiti Teknologi Petronas","ror":"https://ror.org/048g2sh07","country_code":"MY","type":"education","lineage":["https://openalex.org/I203899302"]}],"countries":["MY"],"is_corresponding":false,"raw_author_name":"P. Arun Mozhi Devan","raw_affiliation_strings":["Universiti Teknologi PETRONAS,Department of Electrical and Electronics Engineering,Seri Iskandar,Malaysia"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Universiti Teknologi PETRONAS,Department of Electrical and Electronics Engineering,Seri Iskandar,Malaysia","institution_ids":["https://openalex.org/I203899302"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5090412731","display_name":"Nurul Fauzana Imran Gulcharan","orcid":"https://orcid.org/0009-0007-5969-6582","observed_orcids":["https://orcid.org/0009-0007-5969-6582"]},"institutions":[{"id":"https://openalex.org/I203899302","display_name":"Universiti Teknologi Petronas","ror":"https://ror.org/048g2sh07","country_code":"MY","type":"education","lineage":["https://openalex.org/I203899302"]}],"countries":["MY"],"is_corresponding":false,"raw_author_name":"Nurul Fauzana Imran Gulcharan","raw_affiliation_strings":["Universiti Teknologi PETRONAS,Department of Electrical and Electronics Engineering,Seri Iskandar,Malaysia"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Universiti Teknologi PETRONAS,Department of Electrical and Electronics Engineering,Seri Iskandar,Malaysia","institution_ids":["https://openalex.org/I203899302"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5034939930","display_name":"Rosdiazli Ibrahim","orcid":"https://orcid.org/0000-0002-1939-0155","observed_orcids":["https://orcid.org/0000-0002-1939-0155"]},"institutions":[{"id":"https://openalex.org/I203899302","display_name":"Universiti Teknologi Petronas","ror":"https://ror.org/048g2sh07","country_code":"MY","type":"education","lineage":["https://openalex.org/I203899302"]}],"countries":["MY"],"is_corresponding":false,"raw_author_name":"Rosdiazli Ibrahim","raw_affiliation_strings":["Universiti Teknologi PETRONAS,Department of Electrical and Electronics Engineering,Seri Iskandar,Malaysia"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Universiti Teknologi PETRONAS,Department of Electrical and Electronics Engineering,Seri Iskandar,Malaysia","institution_ids":["https://openalex.org/I203899302"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5047088035","display_name":"Madiah Omar","orcid":"https://orcid.org/0000-0002-3975-1253","observed_orcids":["https://orcid.org/0000-0002-3975-1253"]},"institutions":[{"id":"https://openalex.org/I203899302","display_name":"Universiti Teknologi Petronas","ror":"https://ror.org/048g2sh07","country_code":"MY","type":"education","lineage":["https://openalex.org/I203899302"]}],"countries":["MY"],"is_corresponding":false,"raw_author_name":"Madiah Omar","raw_affiliation_strings":["Universiti Teknologi PETRONAS,Department of Integrated Engineering,Seri Iskandar,Malaysia"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Universiti Teknologi PETRONAS,Department of Integrated Engineering,Seri Iskandar,Malaysia","institution_ids":["https://openalex.org/I203899302"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":1,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.0,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"355","last_page":"360"},"is_retracted":false,"is_pulled":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10220","display_name":"Machine Fault Diagnosis Techniques","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10220","display_name":"Machine Fault Diagnosis Techniques","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10780","display_name":"Reliability and Maintenance Optimization","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2213","display_name":"Safety, Risk, Reliability and Quality"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10278","display_name":"Electric Motor Design and Analysis","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/induction-motor-condition-monitoring","display_name":"induction motor condition monitoring","score":0.8920000195503235},{"id":"https://openalex.org/keywords/hilbert-transform","display_name":"Hilbert transform","score":0.9449999928474426},{"id":"https://openalex.org/keywords/fast-fourier-transform","display_name":"fast Fourier transform","score":0.8009999990463257},{"id":"https://openalex.org/keywords/motor-current-signature-analysis","display_name":"motor current signature analysis","score":0.8899999856948853},{"id":"https://openalex.org/keywords/fault-diagnosis","display_name":"fault diagnosis","score":0.5260000228881836},{"id":"https://openalex.org/keywords/condition-based-maintenance","display_name":"condition-based maintenance","score":0.7490000128746033},{"id":"https://openalex.org/keywords/non-invasive-diagnosis","display_name":"non-invasive diagnosis","score":0.6869999766349792},{"id":"https://openalex.org/keywords/spectral-properties","display_name":"spectral properties","score":0.574999988079071},{"id":"https://openalex.org/keywords/instantaneous-frequency-analysis","display_name":"instantaneous frequency analysis","score":0.7519999742507935}],"concepts":[{"id":"https://openalex.org/C2775846686","wikidata":"https://www.wikidata.org/wiki/Q643012","display_name":"Condition monitoring","level":2,"score":0.8159000277519226},{"id":"https://openalex.org/C80962145","wikidata":"https://www.wikidata.org/wiki/Q207450","display_name":"Induction motor","level":3,"score":0.7885000109672546},{"id":"https://openalex.org/C180591934","wikidata":"https://www.wikidata.org/wiki/Q1253369","display_name":"Downtime","level":2,"score":0.770799994468689},{"id":"https://openalex.org/C28799612","wikidata":"https://www.wikidata.org/wiki/Q685437","display_name":"Hilbert transform","level":3,"score":0.5584999918937683},{"id":"https://openalex.org/C63479239","wikidata":"https://www.wikidata.org/wiki/Q7353546","display_name":"Robustness (evolution)","level":3,"score":0.5174999833106995},{"id":"https://openalex.org/C104267543","wikidata":"https://www.wikidata.org/wiki/Q208163","display_name":"Signal processing","level":3,"score":0.5078999996185303},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.49459999799728394},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.4814000129699707},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.462799996137619},{"id":"https://openalex.org/C102519508","wikidata":"https://www.wikidata.org/wiki/Q6520159","display_name":"Fourier transform","level":2,"score":0.45879998803138733},{"id":"https://openalex.org/C152745839","wikidata":"https://www.wikidata.org/wiki/Q5438153","display_name":"Fault detection and isolation","level":3,"score":0.45579999685287476},{"id":"https://openalex.org/C142433447","wikidata":"https://www.wikidata.org/wiki/Q7806653","display_name":"Time\u2013frequency analysis","level":3,"score":0.3984000086784363},{"id":"https://openalex.org/C75172450","wikidata":"https://www.wikidata.org/wiki/Q623950","display_name":"Fast Fourier transform","level":2,"score":0.3882000148296356},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.37310001254081726},{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.3709000051021576},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.36910000443458557},{"id":"https://openalex.org/C25570617","wikidata":"https://www.wikidata.org/wiki/Q1006462","display_name":"Hilbert\u2013Huang transform","level":3,"score":0.32269999384880066},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.31850001215934753},{"id":"https://openalex.org/C105168734","wikidata":"https://www.wikidata.org/wiki/Q1867977","display_name":"Refinery","level":2,"score":0.30570000410079956},{"id":"https://openalex.org/C82753439","wikidata":"https://www.wikidata.org/wiki/Q1419090","display_name":"Industrial production","level":2,"score":0.2906999886035919},{"id":"https://openalex.org/C147494362","wikidata":"https://www.wikidata.org/wiki/Q2078905","display_name":"Troubleshooting","level":2,"score":0.2896000146865845},{"id":"https://openalex.org/C65155139","wikidata":"https://www.wikidata.org/wiki/Q5380912","display_name":"Envelope (radar)","level":3,"score":0.2761000096797943},{"id":"https://openalex.org/C203024314","wikidata":"https://www.wikidata.org/wiki/Q1365258","display_name":"Fourier analysis","level":3,"score":0.27410000562667847},{"id":"https://openalex.org/C171146098","wikidata":"https://www.wikidata.org/wiki/Q124192","display_name":"Automotive engineering","level":1,"score":0.2702000141143799},{"id":"https://openalex.org/C131770355","wikidata":"https://www.wikidata.org/wiki/Q876215","display_name":"Harmonic analysis","level":2,"score":0.2628999948501587},{"id":"https://openalex.org/C137798554","wikidata":"https://www.wikidata.org/wiki/Q6038852","display_name":"Instantaneous phase","level":3,"score":0.2596000134944916},{"id":"https://openalex.org/C70452415","wikidata":"https://www.wikidata.org/wiki/Q3182448","display_name":"Predictive maintenance","level":2,"score":0.25859999656677246},{"id":"https://openalex.org/C166386157","wikidata":"https://www.wikidata.org/wiki/Q1477735","display_name":"Short-time Fourier transform","level":4,"score":0.25850000977516174},{"id":"https://openalex.org/C2777158700","wikidata":"https://www.wikidata.org/wiki/Q1419356","display_name":"Hyporeflexia","level":3,"score":0.2506999969482422}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/icees67011.2025.11212938","doi":"https://doi.org/10.1109/icees67011.2025.11212938","is_oa":false,"landing_page_url":"https://doi.org/10.1109/icees67011.2025.11212938","pdf_url":null,"source":{"id":"https://openalex.org/S7407086565","display_name":"International Conference on Electrical Energy Systems (ICEES)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2025 11th International Conference on Electrical Energy Systems (ICEES)","raw_type":"proceedings-article"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/9","display_name":"Industry, innovation and infrastructure","score":0.7207000255584717}],"study_designs":[],"awards":[],"funders":[{"id":"https://openalex.org/F4320316987","display_name":"PETRONAS","ror":"https://ror.org/02tc7rm90"}],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":14,"referenced_works":["https://openalex.org/W81376923","https://openalex.org/W2081097942","https://openalex.org/W2104972512","https://openalex.org/W2589897153","https://openalex.org/W2771895650","https://openalex.org/W3006281088","https://openalex.org/W3167639673","https://openalex.org/W4285282366","https://openalex.org/W4308581714","https://openalex.org/W4309742266","https://openalex.org/W4323263349","https://openalex.org/W4385431515","https://openalex.org/W4399951174","https://openalex.org/W4410303527"],"related_works":["https://openalex.org/W7137975334","https://openalex.org/W4408017446","https://openalex.org/W4406439345","https://openalex.org/W148660314","https://openalex.org/W4401830310","https://openalex.org/W419408651","https://openalex.org/W7220198577","https://openalex.org/W2036218083","https://openalex.org/W7117555285","https://openalex.org/W2008848858"],"abstract_inverted_index":{"Ensuring":[0],"the":[1,57,67,71,80,148],"reliable":[2],"operation":[3],"of":[4,32,42,116,150],"induction":[5,33],"motors":[6,34,44],"is":[7],"crucial":[8],"in":[9,17,66,79,138,159],"industrial":[10,38,160],"environments,":[11],"where":[12],"unexpected":[13],"failures":[14],"can":[15],"result":[16],"costly":[18],"downtime":[19],"and":[20,62,70,103,142,156],"safety":[21],"risks.":[22],"This":[23],"study":[24],"presents":[25],"a":[26,46,89,107],"signal-based":[27],"approach":[28],"for":[29,60,76],"condition":[30],"monitoring":[31],"operating":[35],"under":[36],"real":[37],"conditions.":[39],"A":[40],"total":[41],"10":[43],"from":[45,88,100],"refinery":[47],"plant":[48],"were":[49,86,98],"analysed":[50],"using":[51],"two":[52],"key":[53],"signal":[54],"processing":[55],"techniques:":[56],"Hilbert":[58],"Transform":[59,74],"envelope":[61],"instantaneous":[63],"frequency":[64,81],"analysis":[65,78,120],"time":[68],"domain,":[69],"Fast":[72],"Fourier":[73],"(FFT)":[75],"spectral":[77,134],"domain.":[82],"Motor":[83],"current":[84],"signals":[85],"acquired":[87],"central":[90],"control":[91],"station,":[92],"enabling":[93],"non-invasive":[94],"diagnostics.":[95],"Fault-sensitive":[96],"features":[97,125,135],"extracted":[99],"both":[101],"domains":[102],"normalised":[104],"to":[105,128],"compute":[106],"composite":[108],"health":[109],"score,":[110],"which":[111],"serves":[112],"as":[113],"an":[114],"indicator":[115],"motor":[117],"condition.":[118],"The":[119,144],"revealed":[121],"that":[122],"Hilbert-based":[123],"temporal":[124],"are":[126],"susceptible":[127],"early":[129],"fault":[130,140],"symptoms,":[131],"while":[132],"FFT-based":[133],"provide":[136],"robustness":[137],"identifying":[139],"types":[141],"severity.":[143],"proposed":[145],"methodology":[146],"supports":[147],"implementation":[149],"condition-based":[151],"maintenance":[152],"strategies,":[153],"enhancing":[154],"reliability":[155],"operational":[157],"efficiency":[158],"environments.":[161]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W4415744758","counts_by_year":[],"updated_date":"2026-11-16T12:05:36.265796","created_date":"2025-10-31T00:00:00"}
