{"id":"https://openalex.org/W4415327359","doi":"https://doi.org/10.1134/s1063784225700367","title":"Fault Location Methods in 6\u201335 kV Distribution Networks with Various Neutral Grounding Modes","display_name":"Fault Location Methods in 6\u201335 kV Distribution Networks with Various Neutral Grounding Modes","publication_year":2025,"publication_date":"2025-09-01","ids":{"openalex":"https://openalex.org/W4415327359","doi":"https://doi.org/10.1134/s1063784225700367"},"language":"en","primary_location":{"id":"doi:10.1134/s1063784225700367","doi":"https://doi.org/10.1134/s1063784225700367","is_oa":false,"landing_page_url":"https://doi.org/10.1134/s1063784225700367","pdf_url":null,"source":{"id":"https://openalex.org/S84376829","display_name":"Technical Physics","issn_l":"1063-7842","issn":["1063-7842","1090-6525"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":["dongbi-d","jufo-1","norway-1","poland-40"],"host_organization":"https://openalex.org/P4310320267","host_organization_name":"Pleiades Publishing","host_organization_lineage":["https://openalex.org/P4310320267","https://openalex.org/P4310319965"],"host_organization_lineage_names":["Pleiades Publishing","Springer Nature"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Technical Physics","raw_type":"journal-article"},"volume":null,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5063773048","display_name":"Ilia Shushpanov","orcid":"https://orcid.org/0000-0001-7121-7651","observed_orcids":["https://orcid.org/0000-0001-7121-7651"]},"institutions":[{"id":"https://openalex.org/I4210122217","display_name":"Irkutsk National Research Technical University","ror":"https://ror.org/01zzkcm34","country_code":"RU","type":"education","lineage":["https://openalex.org/I4210122217"]},{"id":"https://openalex.org/I4210151294","display_name":"Shandong Women\u2019s University","ror":"https://ror.org/03rp8h078","country_code":"CN","type":"education","lineage":["https://openalex.org/I4210151294"]}],"countries":["CN","RU"],"is_corresponding":false,"raw_author_name":"I. N. Shushpanov","raw_affiliation_strings":["Irkutsk National Research Technical University, Irkutsk, Russia","School of Artificial Intelligence, Shandong Women\u2019s University, Jinan, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Irkutsk National Research Technical University, Irkutsk, Russia","institution_ids":["https://openalex.org/I4210122217"]},{"raw_affiliation_string":"School of Artificial Intelligence, Shandong Women\u2019s University, Jinan, China","institution_ids":["https://openalex.org/I4210151294"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5120054367","display_name":"V. V. Romanova","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I171241948","display_name":"Moscow Power Engineering Institute","ror":"https://ror.org/05sa6gg87","country_code":"RU","type":"education","lineage":["https://openalex.org/I171241948"]},{"id":"https://openalex.org/I192758561","display_name":"Transbaikal State University","ror":"https://ror.org/00d55g310","country_code":"RU","type":"education","lineage":["https://openalex.org/I192758561"]}],"countries":["RU"],"is_corresponding":true,"raw_author_name":"V. V. Romanova","raw_affiliation_strings":["Branch of the National Research University MPEI in Volzhsky, Volzhsky, Russia","Transbaikal State University, Chita, Russia"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Branch of the National Research University MPEI in Volzhsky, Volzhsky, Russia","institution_ids":["https://openalex.org/I171241948"]},{"raw_affiliation_string":"Transbaikal State University, Chita, Russia","institution_ids":["https://openalex.org/I192758561"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5138830507","display_name":"Anton Suslov","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I171241948","display_name":"Moscow Power Engineering Institute","ror":"https://ror.org/05sa6gg87","country_code":"RU","type":"education","lineage":["https://openalex.org/I171241948"]}],"countries":["RU"],"is_corresponding":false,"raw_author_name":"A. K. Suslov","raw_affiliation_strings":["National Research University MPEI, Moscow, Russia"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"National Research University MPEI, Moscow, Russia","institution_ids":["https://openalex.org/I171241948"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":4,"corresponding_author_ids":["https://openalex.org/A5120054367"],"corresponding_institution_ids":["https://openalex.org/I171241948","https://openalex.org/I192758561"],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.0,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"70","issue":"9","first_page":"372","last_page":"379"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":1.0,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12737","display_name":"Electrical Fault Detection and Protection","score":0.0,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/fault-localization","display_name":"fault location","score":0.9940000176429749},{"id":"https://openalex.org/keywords/medium-voltage-distribution-networks","display_name":"medium-voltage distribution networks","score":0.8640000224113464},{"id":"https://openalex.org/keywords/neutral-grounding-modes","display_name":"neutral grounding modes","score":0.7879999876022339},{"id":"https://openalex.org/keywords/distributed-generation","display_name":"distributed generation","score":0.7400000095367432},{"id":"https://openalex.org/keywords/relay-protection","display_name":"relay protection","score":0.7540000081062317},{"id":"https://openalex.org/keywords/binary-signal-transmission","display_name":"binary signal transmission","score":0.5630000233650208},{"id":"https://openalex.org/keywords/power-system-protection","display_name":"power system protection","score":0.421999990940094}],"concepts":[{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.7680000066757202},{"id":"https://openalex.org/C168993435","wikidata":"https://www.wikidata.org/wiki/Q6501125","display_name":"Ground","level":2,"score":0.707099974155426},{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.6732000112533569},{"id":"https://openalex.org/C2778156585","wikidata":"https://www.wikidata.org/wiki/Q174053","display_name":"Relay","level":3,"score":0.5940999984741211},{"id":"https://openalex.org/C26517878","wikidata":"https://www.wikidata.org/wiki/Q228039","display_name":"Key (lock)","level":2,"score":0.5318999886512756},{"id":"https://openalex.org/C2780365114","wikidata":"https://www.wikidata.org/wiki/Q169478","display_name":"MATLAB","level":2,"score":0.5289999842643738},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.5266000032424927},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.5238999724388123},{"id":"https://openalex.org/C2779585090","wikidata":"https://www.wikidata.org/wiki/Q3457762","display_name":"Resilience (materials science)","level":2,"score":0.4293999969959259},{"id":"https://openalex.org/C140311924","wikidata":"https://www.wikidata.org/wiki/Q200928","display_name":"Electric power transmission","level":2,"score":0.4242999851703644},{"id":"https://openalex.org/C2779843651","wikidata":"https://www.wikidata.org/wiki/Q7390335","display_name":"SIGNAL (programming language)","level":2,"score":0.41119998693466187},{"id":"https://openalex.org/C761482","wikidata":"https://www.wikidata.org/wiki/Q118093","display_name":"Transmission (telecommunications)","level":2,"score":0.40880000591278076},{"id":"https://openalex.org/C92018576","wikidata":"https://www.wikidata.org/wiki/Q3242194","display_name":"Power transmission","level":3,"score":0.367900013923645},{"id":"https://openalex.org/C21267803","wikidata":"https://www.wikidata.org/wiki/Q5438159","display_name":"Fault indicator","level":4,"score":0.36649999022483826},{"id":"https://openalex.org/C167391956","wikidata":"https://www.wikidata.org/wiki/Q1401211","display_name":"Fault model","level":3,"score":0.36399999260902405},{"id":"https://openalex.org/C186370098","wikidata":"https://www.wikidata.org/wiki/Q442787","display_name":"Energy (signal processing)","level":2,"score":0.36239999532699585},{"id":"https://openalex.org/C48372109","wikidata":"https://www.wikidata.org/wiki/Q3913","display_name":"Binary number","level":2,"score":0.36160001158714294},{"id":"https://openalex.org/C188573790","wikidata":"https://www.wikidata.org/wiki/Q12705","display_name":"Renewable energy","level":2,"score":0.34279999136924744},{"id":"https://openalex.org/C40293303","wikidata":"https://www.wikidata.org/wiki/Q27137","display_name":"Electric power","level":3,"score":0.3407000005245209},{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.3239000141620636},{"id":"https://openalex.org/C38361682","wikidata":"https://www.wikidata.org/wiki/Q1756067","display_name":"Power-system protection","level":4,"score":0.3172000050544739},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.3075000047683716},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.29319998621940613},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.2822999954223633},{"id":"https://openalex.org/C544738498","wikidata":"https://www.wikidata.org/wiki/Q861135","display_name":"Distributed generation","level":3,"score":0.25999999046325684},{"id":"https://openalex.org/C113608303","wikidata":"https://www.wikidata.org/wiki/Q1056835","display_name":"Transmission system","level":3,"score":0.2565999925136566},{"id":"https://openalex.org/C110121322","wikidata":"https://www.wikidata.org/wiki/Q865811","display_name":"Distribution (mathematics)","level":2,"score":0.25429999828338623}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1134/s1063784225700367","doi":"https://doi.org/10.1134/s1063784225700367","is_oa":false,"landing_page_url":"https://doi.org/10.1134/s1063784225700367","pdf_url":null,"source":{"id":"https://openalex.org/S84376829","display_name":"Technical Physics","issn_l":"1063-7842","issn":["1063-7842","1090-6525"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":["dongbi-d","jufo-1","norway-1","poland-40"],"host_organization":"https://openalex.org/P4310320267","host_organization_name":"Pleiades Publishing","host_organization_lineage":["https://openalex.org/P4310320267","https://openalex.org/P4310319965"],"host_organization_lineage_names":["Pleiades Publishing","Springer Nature"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"Technical Physics","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"display_name":"Industry, innovation and infrastructure","id":"https://metadata.un.org/sdg/9","score":0.7207000255584717}],"study_designs":[],"awards":[],"funders":[],"has_content":{"grobid_xml":false,"pdf":false},"content_urls":null,"referenced_works_count":10,"referenced_works":["https://openalex.org/W1999461894","https://openalex.org/W2143899765","https://openalex.org/W2401889698","https://openalex.org/W4224989792","https://openalex.org/W4297001588","https://openalex.org/W4380373459","https://openalex.org/W4386220261","https://openalex.org/W4391653433","https://openalex.org/W4408146789","https://openalex.org/W4409195105"],"related_works":["https://openalex.org/W4386921428","https://openalex.org/W4385073259","https://openalex.org/W7123353958","https://openalex.org/W1583190382","https://openalex.org/W2367909022","https://openalex.org/W2352716086","https://openalex.org/W4380078305","https://openalex.org/W3204633462","https://openalex.org/W2373334469","https://openalex.org/W7124877928"],"abstract_inverted_index":{"Abstract":[0],"The":[1,39,93],"paper":[2,94],"presents":[3,95],"a":[4,52,60,79],"fault":[5,37],"localization":[6],"algorithm":[7],"for":[8,55],"medium-voltage":[9],"networks":[10],"of":[11,25,29,36,47,63,78,99],"electric":[12],"power":[13,27,57],"systems":[14,58],"and":[15,106,109],"complexes.":[16],"This":[17],"approach":[18],"utilizes":[19],"information":[20],"derived":[21],"from":[22],"an":[23],"analysis":[24],"the":[26,30,45,76,96,100,115,119],"direction":[28],"zero-sequence":[31],"components,":[32],"ensuring":[33],"high":[34,61],"accuracy":[35],"location.":[38],"proposed":[40],"method":[41],"demonstrates":[42],"resilience":[43],"to":[44,89,122,128],"impact":[46],"distributed":[48],"generation,":[49],"making":[50],"it":[51,103],"promising":[53],"option":[54],"modern":[56],"with":[59],"share":[62],"renewable":[64],"energy":[65],"sources.":[66],"Its":[67],"key":[68],"advantage":[69],"is":[70,87],"reliance":[71],"on":[72],"minimal":[73],"infrastructure,":[74],"as":[75],"transmission":[77],"single":[80],"binary":[81],"signal":[82],"between":[83],"relay":[84],"protection":[85],"devices":[86],"sufficient":[88],"ensure":[90],"correct":[91],"operation.":[92],"theoretical":[97],"foundations":[98],"method,":[101],"tests":[102],"using":[104],"Sincal":[105],"MATLAB":[107],"software,":[108],"suggests":[110],"applications.":[111],"A":[112],"simulation":[113],"confirmed":[114],"method\u2019s":[116],"effectiveness,":[117],"reducing":[118],"time":[120],"required":[121],"locate":[123],"faults":[124],"by":[125],"40\u201360%":[126],"compared":[127],"traditional":[129],"approaches.":[130]},"counts_by_year":[],"updated_date":"2026-10-12T09:40:04.860316","created_date":"2025-10-19T00:00:00"}
