{"id":"https://openalex.org/W4415168564","doi":"https://doi.org/10.1049/icp.2025.2241","title":"New improved method for measuring the earthfault-distance in non-solid grounded networks","display_name":"New improved method for measuring the earthfault-distance in non-solid grounded networks","publication_year":2025,"publication_date":"2025-10-14","ids":{"openalex":"https://openalex.org/W4415168564","doi":"https://doi.org/10.1049/icp.2025.2241"},"language":"en","primary_location":{"id":"doi:10.1049/icp.2025.2241","doi":"https://doi.org/10.1049/icp.2025.2241","is_oa":false,"landing_page_url":"https://doi.org/10.1049/icp.2025.2241","pdf_url":null,"source":{"id":"https://openalex.org/S4404663355","display_name":"IET conference proceedings.","issn_l":"2732-4494","issn":["2732-4494"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":["jufo-1"],"host_organization":"https://openalex.org/P4310311714","host_organization_name":"Institution of Engineering and Technology","host_organization_lineage":["https://openalex.org/P4310311714"],"host_organization_lineage_names":["Institution of Engineering and Technology"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IET Conference Proceedings","raw_type":"journal-article"},"volume":null,"type":"conference-paper","indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5075357045","display_name":"Gernot Druml","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Gernot Druml","raw_affiliation_strings":["Sprecher Automation, Linz, Austria"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Sprecher Automation, Linz, Austria","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5015465890","display_name":"Robert Steinbichler","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Robert Steinbichler","raw_affiliation_strings":["Netze Ober\u00f6sterreich, Gmunden, Austria"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Netze Ober\u00f6sterreich, Gmunden, Austria","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5086187980","display_name":"Bruno Wartmann","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Bruno Wartmann","raw_affiliation_strings":["Elektrizit\u00e4tswerk der Stadt Z\u00fcrich (ewz), Z\u00fcrich, Switzerland"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Elektrizit\u00e4tswerk der Stadt Z\u00fcrich (ewz), Z\u00fcrich, Switzerland","institution_ids":[]}]},{"author_position":"middle","author":{"id":null,"display_name":"Christian Freund","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Christian Freund","raw_affiliation_strings":["Elektrizit\u00e4tswerk der Stadt Z\u00fcrich (ewz), Z\u00fcrich, Switzerland"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Elektrizit\u00e4tswerk der Stadt Z\u00fcrich (ewz), Z\u00fcrich, Switzerland","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5075914253","display_name":"Thomas Schinerl","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Thomas Schinerl","raw_affiliation_strings":["Sprecher Automation, Linz, Austria"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Sprecher Automation, Linz, Austria","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5074520727","display_name":"Oliver Skrbinjek","orcid":null,"observed_orcids":[]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Oliver Skrbinjek","raw_affiliation_strings":["Energie Steiermark, Graz, Austria"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Energie Steiermark, Graz, Austria","institution_ids":[]}]},{"author_position":"middle","author":{"id":null,"display_name":"J\u00f6rg Meyer","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4210165059","display_name":"Hochschule f\u00fcr Technik und Wirtschaft Dresden \u2013 University of Applied Sciences","ror":"https://ror.org/05q5pk319","country_code":"DE","type":"education","lineage":["https://openalex.org/I4210165059"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"J\u00f6rg Meyer","raw_affiliation_strings":["HTW Dresden, Dresden, Germany"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"HTW Dresden, Dresden, Germany","institution_ids":["https://openalex.org/I4210165059"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5070454447","display_name":"Peter Schegner","orcid":"https://orcid.org/0000-0001-8439-7786","observed_orcids":["https://orcid.org/0000-0001-8439-7786"]},"institutions":[{"id":"https://openalex.org/I78650965","display_name":"Technische Universit\u00e4t Dresden","ror":"https://ror.org/042aqky30","country_code":"DE","type":"education","lineage":["https://openalex.org/I78650965"]}],"countries":["DE"],"is_corresponding":false,"raw_author_name":"Peter Schegner","raw_affiliation_strings":["TUD Dresden University of Technology, Dresden, Germany"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"TUD Dresden University of Technology, Dresden, Germany","institution_ids":["https://openalex.org/I78650965"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.32314323,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"2025","issue":"14","first_page":"3016","last_page":"3020"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10972","display_name":"Power Systems Fault Detection","score":0.9994999766349792,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T12737","display_name":"Electrical Fault Detection and Protection","score":0.00019999999494757503,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10305","display_name":"Power System Optimization and Stability","score":9.999999747378752e-05,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/symmetrical-component-method","display_name":"symmetrical components","score":0.7039999961853027},{"id":"https://openalex.org/keywords/fault-current-discrimination","display_name":"fault current discrimination","score":0.5149999856948853},{"id":"https://openalex.org/keywords/load-current","display_name":"load current","score":0.753000020980835},{"id":"https://openalex.org/keywords/low-current-arc","display_name":"low-current arc","score":0.8199999928474426},{"id":"https://openalex.org/keywords/cable-faults","display_name":"cable faults","score":0.546999990940094},{"id":"https://openalex.org/keywords/impedance-measurement","display_name":"impedance measurement","score":0.5170000195503235}],"concepts":[{"id":"https://openalex.org/C175551986","wikidata":"https://www.wikidata.org/wiki/Q47089","display_name":"Fault (geology)","level":2,"score":0.6718000173568726},{"id":"https://openalex.org/C21267803","wikidata":"https://www.wikidata.org/wiki/Q5438159","display_name":"Fault indicator","level":4,"score":0.5694000124931335},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.5551999807357788},{"id":"https://openalex.org/C17829176","wikidata":"https://www.wikidata.org/wiki/Q179043","display_name":"Electrical impedance","level":2,"score":0.5289000272750854},{"id":"https://openalex.org/C148043351","wikidata":"https://www.wikidata.org/wiki/Q4456944","display_name":"Current (fluid)","level":2,"score":0.5034999847412109},{"id":"https://openalex.org/C129187525","wikidata":"https://www.wikidata.org/wiki/Q10858078","display_name":"Fault current limiter","level":4,"score":0.45879998803138733},{"id":"https://openalex.org/C2779960059","wikidata":"https://www.wikidata.org/wiki/Q7113681","display_name":"Overhead (engineering)","level":2,"score":0.444599986076355},{"id":"https://openalex.org/C28719098","wikidata":"https://www.wikidata.org/wiki/Q44946","display_name":"Point (geometry)","level":2,"score":0.42010000348091125},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.413100004196167},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.3955000042915344},{"id":"https://openalex.org/C152745839","wikidata":"https://www.wikidata.org/wiki/Q5438153","display_name":"Fault detection and isolation","level":3,"score":0.385699987411499},{"id":"https://openalex.org/C13625343","wikidata":"https://www.wikidata.org/wiki/Q7627418","display_name":"Stuck-at fault","level":4,"score":0.37720000743865967},{"id":"https://openalex.org/C2775861652","wikidata":"https://www.wikidata.org/wiki/Q110701","display_name":"Overhead line","level":2,"score":0.36469998955726624},{"id":"https://openalex.org/C18762648","wikidata":"https://www.wikidata.org/wiki/Q42213","display_name":"Work (physics)","level":2,"score":0.3492000102996826},{"id":"https://openalex.org/C119599485","wikidata":"https://www.wikidata.org/wiki/Q43035","display_name":"Electrical engineering","level":1,"score":0.3294000029563904},{"id":"https://openalex.org/C197424946","wikidata":"https://www.wikidata.org/wiki/Q1165717","display_name":"Waveform","level":3,"score":0.32499998807907104},{"id":"https://openalex.org/C167391956","wikidata":"https://www.wikidata.org/wiki/Q1401211","display_name":"Fault model","level":3,"score":0.32440000772476196},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.31459999084472656},{"id":"https://openalex.org/C182365436","wikidata":"https://www.wikidata.org/wiki/Q50701","display_name":"Variable (mathematics)","level":2,"score":0.30809998512268066},{"id":"https://openalex.org/C168993435","wikidata":"https://www.wikidata.org/wiki/Q6501125","display_name":"Ground","level":2,"score":0.30660000443458557},{"id":"https://openalex.org/C37649242","wikidata":"https://www.wikidata.org/wiki/Q932268","display_name":"System of measurement","level":2,"score":0.2791000008583069},{"id":"https://openalex.org/C2780799671","wikidata":"https://www.wikidata.org/wiki/Q17087362","display_name":"Transient (computer programming)","level":2,"score":0.26919999718666077},{"id":"https://openalex.org/C126953365","wikidata":"https://www.wikidata.org/wiki/Q5438152","display_name":"Fault coverage","level":3,"score":0.2676999866962433},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.2639999985694885},{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.2572999894618988},{"id":"https://openalex.org/C165296897","wikidata":"https://www.wikidata.org/wiki/Q552380","display_name":"Symmetrical components","level":4,"score":0.2524999976158142},{"id":"https://openalex.org/C55000061","wikidata":"https://www.wikidata.org/wiki/Q24894777","display_name":"Current sensor","level":3,"score":0.2524000108242035}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1049/icp.2025.2241","doi":"https://doi.org/10.1049/icp.2025.2241","is_oa":false,"landing_page_url":"https://doi.org/10.1049/icp.2025.2241","pdf_url":null,"source":{"id":"https://openalex.org/S4404663355","display_name":"IET conference proceedings.","issn_l":"2732-4494","issn":["2732-4494"],"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":["jufo-1"],"host_organization":"https://openalex.org/P4310311714","host_organization_name":"Institution of Engineering and Technology","host_organization_lineage":["https://openalex.org/P4310311714"],"host_organization_lineage_names":["Institution of Engineering and Technology"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IET Conference Proceedings","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[],"sustainable_development_goals_aurora":[],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":0,"referenced_works":[],"related_works":[],"abstract_inverted_index":{"Current":[0],"earth":[1,170],"fault":[2,23,42,51,122,139,153],"distance":[3],"measurement":[4,146],"based":[5],"on":[6],"symmetrical":[7],"components":[8],"does":[9],"not":[10,34,63],"work":[11],"very":[12],"well":[13],"in":[14,66,73,164,172],"compensated":[15],"systems":[16],"because":[17],"the":[18,22,29,50,54,64,67,74,98,106,110,121,125,132,135,138,144,148,152,161],"steady-state":[19],"currents":[20],"through":[21],"location":[24,154],"are":[25],"significantly":[26,156],"smaller":[27],"than":[28],"load":[30,39,126],"currents.":[31],"It":[32,44],"is":[33,56,62,115,155],"possible":[35,117],"to":[36,118,129,151],"distinguish":[37,119],"between":[38,120],"current":[40,99,123,127],"and":[41,91,103,124,128,168,174],"current.":[43],"has":[45],"also":[46],"been":[47],"assumed":[48],"that":[49],"impedance,":[52],"including":[53],"arc,":[55],"a":[57,78],"linear":[58],"impedance.":[59],"However,":[60],"this":[61],"case":[65],"real":[68],"world,":[69],"especially":[70],"for":[71,131,166],"faults":[72,171],"cable":[75,175],"section":[76],"of":[77,87,105,134,137,143],"line.":[79],"The":[80,141],"air":[81],"gap":[82],"creates":[83],"an":[84],"additional":[85],"layer":[86],"insulation":[88],"with":[89],"increased":[90],"variable":[92],"ignition":[93],"voltage.":[94],"This":[95,158],"non-linearity":[96],"affects":[97],"waveform,":[100,102],"voltage":[101],"frequency":[104],"low-current":[107],"arc.":[108],"With":[109],"new":[111,162],"modified":[112],"method,":[113],"it":[114],"now":[116],"compensate":[130],"effects":[133],"nonlinearities":[136],"impedances.":[140],"accuracy":[142],"impedance":[145],"from":[147],"measuring":[149],"point":[150],"improved.":[157],"paper":[159],"presents":[160],"method":[163],"detail":[165],"self-extinguishing":[167],"re-igniting":[169],"overhead":[173],"networks.":[176]},"counts_by_year":[],"updated_date":"2026-09-29T14:09:16.559479","created_date":"2025-10-15T00:00:00"}
