{"id":"https://openalex.org/W4415033775","doi":"https://doi.org/10.1109/mim.2025.11198884","title":"Fundamentals in Measurement: Basic Practical Elements of Quality Assessment of Calibration Laboratory Activities","display_name":"Fundamentals in Measurement: Basic Practical Elements of Quality Assessment of Calibration Laboratory Activities","publication_year":2025,"publication_date":"2025-10-01","ids":{"openalex":"https://openalex.org/W4415033775","doi":"https://doi.org/10.1109/mim.2025.11198884"},"language":"en","primary_location":{"id":"doi:10.1109/mim.2025.11198884","doi":"https://doi.org/10.1109/mim.2025.11198884","is_oa":false,"landing_page_url":"https://doi.org/10.1109/mim.2025.11198884","pdf_url":null,"source":{"id":"https://openalex.org/S121167460","display_name":"IEEE Instrumentation & Measurement Magazine","issn_l":"1094-6969","issn":["1094-6969","1941-0123"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-b","jufo-1","ki-jl-1","norway-1","poland-70","russia-white-list-2","vabb-shw"],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Instrumentation &amp; Measurement Magazine","raw_type":"journal-article"},"volume":null,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5027147528","display_name":"Oleh Velychko","orcid":"https://orcid.org/0000-0002-6564-4144","observed_orcids":["https://orcid.org/0000-0002-6564-4144"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Oleh Velychko","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"middle","author":{"id":"https://openalex.org/A5007372942","display_name":"Tetyana Gordiyenko","orcid":"https://orcid.org/0000-0003-0324-9672","observed_orcids":["https://orcid.org/0000-0003-0324-9672"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Tetyana Gordiyenko","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]},{"author_position":"last","author":{"id":"https://openalex.org/A5075122198","display_name":"Sergii Kursin","orcid":"https://orcid.org/0000-0003-2147-6211","observed_orcids":["https://orcid.org/0000-0003-2147-6211"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Sergii Kursin","raw_affiliation_strings":[],"raw_orcid":null,"affiliations":[]}],"institutions":[],"countries_distinct_count":0,"institutions_distinct_count":0,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":{"value":2995,"currency":"USD","value_usd":2995},"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.0,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":"28","issue":"7","first_page":"6","last_page":"12"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T11890","display_name":"Scientific Measurement and Uncertainty Evaluation","score":0.9937000274658203,"subfield":{"id":"https://openalex.org/subfields/3105","display_name":"Instrumentation"},"field":{"id":"https://openalex.org/fields/31","display_name":"Physics and Astronomy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T11890","display_name":"Scientific Measurement and Uncertainty Evaluation","score":0.9937000274658203,"subfield":{"id":"https://openalex.org/subfields/3105","display_name":"Instrumentation"},"field":{"id":"https://openalex.org/fields/31","display_name":"Physics and Astronomy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T13164","display_name":"Quality and Management Systems","score":0.003000000026077032,"subfield":{"id":"https://openalex.org/subfields/1408","display_name":"Strategy and Management"},"field":{"id":"https://openalex.org/fields/14","display_name":"Business, Management and Accounting"},"domain":{"id":"https://openalex.org/domains/2","display_name":"Social Sciences"}},{"id":"https://openalex.org/T11583","display_name":"Advanced Measurement and Metrology Techniques","score":0.00139999995008111,"subfield":{"id":"https://openalex.org/subfields/2210","display_name":"Mechanical Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/calibration-laboratories","display_name":"calibration laboratories","score":0.9520000219345093},{"id":"https://openalex.org/keywords/measurement-quality-assessment","display_name":"measurement quality assessment","score":0.6439999938011169},{"id":"https://openalex.org/keywords/measurement-standards","display_name":"measurement standards","score":0.9739999771118164},{"id":"https://openalex.org/keywords/testing-laboratories","display_name":"testing laboratories","score":0.8510000109672546},{"id":"https://openalex.org/keywords/quality-infrastructure","display_name":"quality infrastructure","score":0.8299999833106995},{"id":"https://openalex.org/keywords/measurement-uncertainty","display_name":"measurement uncertainty","score":0.36800000071525574}],"concepts":[{"id":"https://openalex.org/C200601418","wikidata":"https://www.wikidata.org/wiki/Q2193887","display_name":"Reliability engineering","level":1,"score":0.7152000069618225},{"id":"https://openalex.org/C165838908","wikidata":"https://www.wikidata.org/wiki/Q736777","display_name":"Calibration","level":2,"score":0.6974999904632568},{"id":"https://openalex.org/C43214815","wikidata":"https://www.wikidata.org/wiki/Q7310987","display_name":"Reliability (semiconductor)","level":3,"score":0.6586999893188477},{"id":"https://openalex.org/C2779530757","wikidata":"https://www.wikidata.org/wiki/Q1207505","display_name":"Quality (philosophy)","level":2,"score":0.6060000061988831},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.5546000003814697},{"id":"https://openalex.org/C106436119","wikidata":"https://www.wikidata.org/wiki/Q836575","display_name":"Quality assurance","level":3,"score":0.49570000171661377},{"id":"https://openalex.org/C201995342","wikidata":"https://www.wikidata.org/wiki/Q682496","display_name":"Systems engineering","level":1,"score":0.4699000120162964},{"id":"https://openalex.org/C76844732","wikidata":"https://www.wikidata.org/wiki/Q4072285","display_name":"Conformance testing","level":3,"score":0.4278999865055084},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.3880000114440918},{"id":"https://openalex.org/C3020001037","wikidata":"https://www.wikidata.org/wiki/Q836575","display_name":"Quality assessment","level":3,"score":0.38350000977516174},{"id":"https://openalex.org/C117671659","wikidata":"https://www.wikidata.org/wiki/Q11049265","display_name":"Manufacturing engineering","level":1,"score":0.362199991941452},{"id":"https://openalex.org/C51704429","wikidata":"https://www.wikidata.org/wiki/Q827792","display_name":"Quality control","level":3,"score":0.35280001163482666},{"id":"https://openalex.org/C2777267654","wikidata":"https://www.wikidata.org/wiki/Q3519023","display_name":"Test (biology)","level":2,"score":0.3450999855995178},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.336899995803833},{"id":"https://openalex.org/C131377759","wikidata":"https://www.wikidata.org/wiki/Q322514","display_name":"Acceptance testing","level":2,"score":0.33640000224113464},{"id":"https://openalex.org/C201289532","wikidata":"https://www.wikidata.org/wiki/Q608513","display_name":"Quality management system","level":4,"score":0.32249999046325684},{"id":"https://openalex.org/C2983725658","wikidata":"https://www.wikidata.org/wiki/Q7705768","display_name":"Test equipment","level":2,"score":0.320499986410141},{"id":"https://openalex.org/C62646347","wikidata":"https://www.wikidata.org/wiki/Q2041172","display_name":"Measuring instrument","level":2,"score":0.3156999945640564},{"id":"https://openalex.org/C5911748","wikidata":"https://www.wikidata.org/wiki/Q4072285","display_name":"Conformity assessment","level":2,"score":0.30799999833106995},{"id":"https://openalex.org/C195766429","wikidata":"https://www.wikidata.org/wiki/Q394","display_name":"Metrology","level":2,"score":0.28349998593330383},{"id":"https://openalex.org/C137209882","wikidata":"https://www.wikidata.org/wiki/Q1403517","display_name":"Measurement uncertainty","level":2,"score":0.28279998898506165},{"id":"https://openalex.org/C132519959","wikidata":"https://www.wikidata.org/wiki/Q3077373","display_name":"Test method","level":2,"score":0.27880001068115234},{"id":"https://openalex.org/C2992690752","wikidata":"https://www.wikidata.org/wiki/Q6979684","display_name":"National standard","level":2,"score":0.27630001306533813},{"id":"https://openalex.org/C188598960","wikidata":"https://www.wikidata.org/wiki/Q7705805","display_name":"Test strategy","level":3,"score":0.2624000012874603},{"id":"https://openalex.org/C7166840","wikidata":"https://www.wikidata.org/wiki/Q1199682","display_name":"System testing","level":2,"score":0.2612999975681305},{"id":"https://openalex.org/C2776179734","wikidata":"https://www.wikidata.org/wiki/Q7398668","display_name":"Safety standards","level":2,"score":0.2603999972343445},{"id":"https://openalex.org/C2778348673","wikidata":"https://www.wikidata.org/wiki/Q739302","display_name":"Production (economics)","level":2,"score":0.25369998812675476},{"id":"https://openalex.org/C18555067","wikidata":"https://www.wikidata.org/wiki/Q8375051","display_name":"Joint (building)","level":2,"score":0.2526000142097473},{"id":"https://openalex.org/C46717995","wikidata":"https://www.wikidata.org/wiki/Q7268785","display_name":"Quality of analytical results","level":5,"score":0.25220000743865967}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/mim.2025.11198884","doi":"https://doi.org/10.1109/mim.2025.11198884","is_oa":false,"landing_page_url":"https://doi.org/10.1109/mim.2025.11198884","pdf_url":null,"source":{"id":"https://openalex.org/S121167460","display_name":"IEEE Instrumentation & Measurement Magazine","issn_l":"1094-6969","issn":["1094-6969","1941-0123"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-b","jufo-1","ki-jl-1","norway-1","poland-70","russia-white-list-2","vabb-shw"],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Instrumentation &amp; Measurement Magazine","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[],"study_designs":[],"awards":[],"funders":[],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":4,"referenced_works":["https://openalex.org/W3158724076","https://openalex.org/W3196005876","https://openalex.org/W4405654727","https://openalex.org/W4405667164"],"related_works":["https://openalex.org/W6885089745","https://openalex.org/W7131782370","https://openalex.org/W4255039235","https://openalex.org/W2883601761","https://openalex.org/W4414670604","https://openalex.org/W2035631394","https://openalex.org/W7095486851","https://openalex.org/W2030967307","https://openalex.org/W4381890160","https://openalex.org/W2139118994"],"abstract_inverted_index":{"Testing":[0],"and":[1,17,21,48,68,78,84,93,101],"calibration":[2,60,94],"laboratories":[3,33,61,83,95],"are":[4],"important":[5],"components":[6,37],"of":[7,19,24,31,59,76,91,103],"the":[8,14,74,99,104,110,115],"national":[9,49,111],"quality":[10,22,100],"infrastructure.":[11],"They":[12],"ensure":[13],"accuracy,":[15],"reliability":[16],"safety":[18,102],"production":[20],"control":[23],"various":[25],"manufactured":[26],"products.":[27],"The":[28,56,88],"primary":[29],"purpose":[30,58],"testing":[32,82,92],"is":[34,63],"to":[35,41,64,97],"test":[36],"or":[38,53],"finished":[39],"products":[40,106],"determine":[42],"their":[43],"compliance":[44],"with":[45,73],"international,":[46],"regional,":[47],"standards,":[50],"technical":[51],"regulations,":[52],"manufacturer":[54,79],"specifications.":[55],"main":[57],"(CLs)":[62],"calibrate":[65],"measuring":[66],"instruments":[67],"measurement":[69],"standards":[70,77],"in":[71,109,114],"accordance":[72],"requirements":[75],"specifications":[80],"for":[81],"other":[85],"end":[86],"users.":[87],"joint":[89],"activities":[90],"contribute":[96],"proving":[98],"manufacturer's":[105],"not":[107],"only":[108],"but":[112],"also":[113],"global":[116],"markets.":[117]},"counts_by_year":[],"updated_date":"2026-08-21T09:56:20.448147","created_date":"2025-10-10T00:00:00"}
