{"id":"https://openalex.org/W4414908758","doi":"https://doi.org/10.1109/tia.2025.3618599","title":"A Series Flexible Transfer Converter With Reduced Cost While Keeping Functions of Instant Power Support and Auto-Synchronization for Microgrid","display_name":"A Series Flexible Transfer Converter With Reduced Cost While Keeping Functions of Instant Power Support and Auto-Synchronization for Microgrid","alternate_titles":[],"publication_year":2025,"publication_date":"2025-10-07","ids":{"openalex":"https://openalex.org/W4414908758","doi":"https://doi.org/10.1109/tia.2025.3618599"},"language":"en","primary_location":{"id":"doi:10.1109/tia.2025.3618599","doi":"https://doi.org/10.1109/tia.2025.3618599","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tia.2025.3618599","pdf_url":null,"source":{"id":"https://openalex.org/S192268925","display_name":"IEEE Transactions on Industry Applications","issn_l":"0093-9994","issn":["0093-9994","1939-9367"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-b","jufo-2","ki-jl-1","norway-1","poland-140","russia-white-list-1","vabb-shw"],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Industry Applications","raw_type":"journal-article"},"parent_works":[],"lineage":["https://openalex.org/W4414908758"],"child_works_count":0,"type":"article","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5000261829","display_name":"Zhaoqi Song","orcid":"https://orcid.org/0000-0002-5435-6200","observed_orcids":["https://orcid.org/0000-0002-5435-6200"]},"institutions":[{"id":"https://openalex.org/I4391768273","display_name":"State Key Laboratory of Electrical Insulation and Power Equipment","ror":"https://ror.org/03kd9rr37","country_code":"CN","type":"facility","lineage":["https://openalex.org/I4391768273","https://openalex.org/I87445476"]},{"id":"https://openalex.org/I87445476","display_name":"Xi'an Jiaotong University","ror":"https://ror.org/017zhmm22","country_code":"CN","type":"education","lineage":["https://openalex.org/I87445476"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Zhaoqi Song","raw_affiliation_strings":["State Key Lab of Electrical Insulation and Power Equipment, School of Electrical Engineering, Xi\u2019an Jiaotong University, Xi\u2019an, China"],"raw_orcid":"https://orcid.org/0000-0002-5435-6200","affiliations":[{"raw_affiliation_string":"State Key Lab of Electrical Insulation and Power Equipment, School of Electrical Engineering, Xi\u2019an Jiaotong University, Xi\u2019an, China","institution_ids":["https://openalex.org/I4391768273","https://openalex.org/I87445476"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5080512973","display_name":"Ronghui An","orcid":"https://orcid.org/0000-0002-7074-5994","observed_orcids":["https://orcid.org/0000-0002-7074-5994"]},"institutions":[{"id":"https://openalex.org/I4391768273","display_name":"State Key Laboratory of Electrical Insulation and Power Equipment","ror":"https://ror.org/03kd9rr37","country_code":"CN","type":"facility","lineage":["https://openalex.org/I4391768273","https://openalex.org/I87445476"]},{"id":"https://openalex.org/I87445476","display_name":"Xi'an Jiaotong University","ror":"https://ror.org/017zhmm22","country_code":"CN","type":"education","lineage":["https://openalex.org/I87445476"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Ronghui An","raw_affiliation_strings":["State Key Lab of Electrical Insulation and Power Equipment, School of Electrical Engineering, Xi\u2019an Jiaotong University, Xi\u2019an, China"],"raw_orcid":"https://orcid.org/0000-0002-7074-5994","affiliations":[{"raw_affiliation_string":"State Key Lab of Electrical Insulation and Power Equipment, School of Electrical Engineering, Xi\u2019an Jiaotong University, Xi\u2019an, China","institution_ids":["https://openalex.org/I4391768273","https://openalex.org/I87445476"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5040774062","display_name":"Jinjun Liu","orcid":"https://orcid.org/0000-0003-0050-2548","observed_orcids":["https://orcid.org/0000-0003-0050-2548"]},"institutions":[{"id":"https://openalex.org/I4391768273","display_name":"State Key Laboratory of Electrical Insulation and Power Equipment","ror":"https://ror.org/03kd9rr37","country_code":"CN","type":"facility","lineage":["https://openalex.org/I4391768273","https://openalex.org/I87445476"]},{"id":"https://openalex.org/I87445476","display_name":"Xi'an Jiaotong University","ror":"https://ror.org/017zhmm22","country_code":"CN","type":"education","lineage":["https://openalex.org/I87445476"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Jinjun Liu","raw_affiliation_strings":["State Key Lab of Electrical Insulation and Power Equipment, School of Electrical Engineering, Xi\u2019an Jiaotong University, Xi\u2019an, China"],"raw_orcid":"https://orcid.org/0000-0003-0050-2548","affiliations":[{"raw_affiliation_string":"State Key Lab of Electrical Insulation and Power Equipment, School of Electrical Engineering, Xi\u2019an Jiaotong University, Xi\u2019an, China","institution_ids":["https://openalex.org/I4391768273","https://openalex.org/I87445476"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5101723866","display_name":"Zeng Liu","orcid":"https://orcid.org/0000-0003-4845-0273","observed_orcids":["https://orcid.org/0000-0003-4845-0273"]},"institutions":[{"id":"https://openalex.org/I4391768273","display_name":"State Key Laboratory of Electrical Insulation and Power Equipment","ror":"https://ror.org/03kd9rr37","country_code":"CN","type":"facility","lineage":["https://openalex.org/I4391768273","https://openalex.org/I87445476"]},{"id":"https://openalex.org/I87445476","display_name":"Xi'an Jiaotong University","ror":"https://ror.org/017zhmm22","country_code":"CN","type":"education","lineage":["https://openalex.org/I87445476"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Zeng Liu","raw_affiliation_strings":["State Key Lab of Electrical Insulation and Power Equipment, School of Electrical Engineering, Xi\u2019an Jiaotong University, Xi\u2019an, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"State Key Lab of Electrical Insulation and Power Equipment, School of Electrical Engineering, Xi\u2019an Jiaotong University, Xi\u2019an, China","institution_ids":["https://openalex.org/I4391768273","https://openalex.org/I87445476"]}]},{"author_position":"middle","author":{"id":null,"display_name":"Xiaoguang Wei","orcid":"https://orcid.org/0009-0008-1211-532X","observed_orcids":["https://orcid.org/0009-0008-1211-532X"]},"institutions":[],"countries":[],"is_corresponding":false,"raw_author_name":"Xiaoguang Wei","raw_affiliation_strings":["Beijing Huairou Laboratory, Beijing, China"],"raw_orcid":"https://orcid.org/0009-0008-1211-532X","affiliations":[{"raw_affiliation_string":"Beijing Huairou Laboratory, Beijing, China","institution_ids":[]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5104333917","display_name":"Ziwen Zhao","orcid":"https://orcid.org/0009-0008-1972-2982","observed_orcids":["https://orcid.org/0009-0008-1972-2982","https://orcid.org/0009-0004-6432-735X"]},"institutions":[{"id":"https://openalex.org/I4391768273","display_name":"State Key Laboratory of Electrical Insulation and Power Equipment","ror":"https://ror.org/03kd9rr37","country_code":"CN","type":"facility","lineage":["https://openalex.org/I4391768273","https://openalex.org/I87445476"]},{"id":"https://openalex.org/I87445476","display_name":"Xi'an Jiaotong University","ror":"https://ror.org/017zhmm22","country_code":"CN","type":"education","lineage":["https://openalex.org/I87445476"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Ziwen Zhao","raw_affiliation_strings":["State Key Lab of Electrical Insulation and Power Equipment, School of Electrical Engineering, Xi\u2019an Jiaotong University, Xi\u2019an, China"],"raw_orcid":"https://orcid.org/0009-0004-6432-735X","affiliations":[{"raw_affiliation_string":"State Key Lab of Electrical Insulation and Power Equipment, School of Electrical Engineering, Xi\u2019an Jiaotong University, Xi\u2019an, China","institution_ids":["https://openalex.org/I4391768273","https://openalex.org/I87445476"]}]},{"author_position":"last","author":{"id":null,"display_name":"Zhiheng Huang","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I4391768273","display_name":"State Key Laboratory of Electrical Insulation and Power Equipment","ror":"https://ror.org/03kd9rr37","country_code":"CN","type":"facility","lineage":["https://openalex.org/I4391768273","https://openalex.org/I87445476"]},{"id":"https://openalex.org/I87445476","display_name":"Xi'an Jiaotong University","ror":"https://ror.org/017zhmm22","country_code":"CN","type":"education","lineage":["https://openalex.org/I87445476"]}],"countries":["CN"],"is_corresponding":false,"raw_author_name":"Zhiheng Huang","raw_affiliation_strings":["State Key Lab of Electrical Insulation and Power Equipment, School of Electrical Engineering, Xi\u2019an Jiaotong University, Xi\u2019an, China"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"State Key Lab of Electrical Insulation and Power Equipment, School of Electrical Engineering, Xi\u2019an Jiaotong University, Xi\u2019an, China","institution_ids":["https://openalex.org/I4391768273","https://openalex.org/I87445476"]}]}],"institutions":[],"countries_distinct_count":1,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":{"value":2645,"currency":"USD","value_usd":2645},"apc_paid":null,"fwci":0.2285,"has_fulltext":false,"cited_by_count":1,"citation_normalized_percentile":{"value":0.37086468,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":{"min":89,"max":94},"biblio":{"volume":"62","issue":"2","first_page":"3068","last_page":"3082"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9980000257492065,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.9980000257492065,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10228","display_name":"Multilevel Inverters and Converters","score":0.0010000000474974513,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T10175","display_name":"Advanced DC-DC Converters","score":0.00039999998989515007,"subfield":{"id":"https://openalex.org/subfields/2208","display_name":"Electrical and Electronic Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/microgrids","display_name":"microgrids","score":0.7139999866485596},{"id":"https://openalex.org/keywords/series-transformer","display_name":"series transformer","score":0.7590000033378601},{"id":"https://openalex.org/keywords/voltage-source-converter","display_name":"voltage source converter","score":0.843999981880188},{"id":"https://openalex.org/keywords/pre-charging","display_name":"pre-charging","score":0.7680000066757202},{"id":"https://openalex.org/keywords/bypassing","display_name":"bypassing","score":0.5860000252723694},{"id":"https://openalex.org/keywords/reactive-power-control","display_name":"reactive power control","score":0.7760000228881836},{"id":"https://openalex.org/keywords/communication-free-control","display_name":"communication-free control","score":0.550000011920929},{"id":"https://openalex.org/keywords/distributed-generation","display_name":"distributed generation","score":0.5839999914169312},{"id":"https://openalex.org/keywords/cost-reduction","display_name":"cost reduction","score":0.5370000004768372}],"concepts":[{"id":"https://openalex.org/C2776784348","wikidata":"https://www.wikidata.org/wiki/Q5762595","display_name":"Microgrid","level":3,"score":0.7687000036239624},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.6151000261306763},{"id":"https://openalex.org/C47446073","wikidata":"https://www.wikidata.org/wiki/Q5165890","display_name":"Control theory (sociology)","level":3,"score":0.53329998254776},{"id":"https://openalex.org/C143724316","wikidata":"https://www.wikidata.org/wiki/Q312468","display_name":"Series (stratigraphy)","level":2,"score":0.5073999762535095},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.4957999885082245},{"id":"https://openalex.org/C108755667","wikidata":"https://www.wikidata.org/wiki/Q1930258","display_name":"AC power","level":3,"score":0.4909999966621399},{"id":"https://openalex.org/C60448319","wikidata":"https://www.wikidata.org/wiki/Q154021","display_name":"Block cipher mode of operation","level":2,"score":0.4431999921798706},{"id":"https://openalex.org/C67186554","wikidata":"https://www.wikidata.org/wiki/Q17103352","display_name":"Maximum power transfer theorem","level":3,"score":0.4318000078201294},{"id":"https://openalex.org/C165801399","wikidata":"https://www.wikidata.org/wiki/Q25428","display_name":"Voltage","level":2,"score":0.42899999022483826},{"id":"https://openalex.org/C48677424","wikidata":"https://www.wikidata.org/wiki/Q6888088","display_name":"Mode (computer interface)","level":2,"score":0.42149999737739563},{"id":"https://openalex.org/C26517878","wikidata":"https://www.wikidata.org/wiki/Q228039","display_name":"Key (lock)","level":2,"score":0.39570000767707825},{"id":"https://openalex.org/C133731056","wikidata":"https://www.wikidata.org/wiki/Q4917288","display_name":"Control engineering","level":1,"score":0.3732999861240387},{"id":"https://openalex.org/C2776175482","wikidata":"https://www.wikidata.org/wiki/Q1195816","display_name":"Transfer (computing)","level":2,"score":0.3695000112056732},{"id":"https://openalex.org/C81299745","wikidata":"https://www.wikidata.org/wiki/Q334269","display_name":"Transfer function","level":2,"score":0.36419999599456787},{"id":"https://openalex.org/C56685638","wikidata":"https://www.wikidata.org/wiki/Q2300474","display_name":"Power control","level":3,"score":0.3433000147342682},{"id":"https://openalex.org/C178911571","wikidata":"https://www.wikidata.org/wiki/Q593143","display_name":"Power electronics","level":3,"score":0.3312000036239624},{"id":"https://openalex.org/C2778422915","wikidata":"https://www.wikidata.org/wiki/Q10302051","display_name":"Converters","level":3,"score":0.3165999948978424},{"id":"https://openalex.org/C2775924081","wikidata":"https://www.wikidata.org/wiki/Q55608371","display_name":"Control (management)","level":2,"score":0.3091999888420105},{"id":"https://openalex.org/C2780799671","wikidata":"https://www.wikidata.org/wiki/Q17087362","display_name":"Transient (computer programming)","level":2,"score":0.3086000084877014},{"id":"https://openalex.org/C24326235","wikidata":"https://www.wikidata.org/wiki/Q126095","display_name":"Electronic engineering","level":1,"score":0.30070000886917114},{"id":"https://openalex.org/C18762648","wikidata":"https://www.wikidata.org/wiki/Q42213","display_name":"Work (physics)","level":2,"score":0.2989000082015991},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.29829999804496765},{"id":"https://openalex.org/C25915539","wikidata":"https://www.wikidata.org/wiki/Q220786","display_name":"Automatic frequency control","level":2,"score":0.2700999975204468},{"id":"https://openalex.org/C2778562939","wikidata":"https://www.wikidata.org/wiki/Q1298791","display_name":"Synchronization (alternating current)","level":3,"score":0.25589999556541443},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.2540999948978424},{"id":"https://openalex.org/C17500928","wikidata":"https://www.wikidata.org/wiki/Q959968","display_name":"Control system","level":2,"score":0.25360000133514404},{"id":"https://openalex.org/C544738498","wikidata":"https://www.wikidata.org/wiki/Q861135","display_name":"Distributed generation","level":3,"score":0.2515000104904175}],"mesh":[],"locations_count":1,"locations":[{"id":"doi:10.1109/tia.2025.3618599","doi":"https://doi.org/10.1109/tia.2025.3618599","is_oa":false,"landing_page_url":"https://doi.org/10.1109/tia.2025.3618599","pdf_url":null,"source":{"id":"https://openalex.org/S192268925","display_name":"IEEE Transactions on Industry Applications","issn_l":"0093-9994","issn":["0093-9994","1939-9367"],"is_oa":false,"is_in_doaj":false,"is_core":true,"listed_in":["cwts-core","dongbi-b","jufo-2","ki-jl-1","norway-1","poland-140","russia-white-list-1","vabb-shw"],"host_organization":"https://openalex.org/P4310319808","host_organization_name":"Institute of Electrical and Electronics Engineers","host_organization_lineage":["https://openalex.org/P4310319808"],"host_organization_lineage_names":["Institute of Electrical and Electronics Engineers"],"type":"journal"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"IEEE Transactions on Industry Applications","raw_type":"journal-article"}],"best_oa_location":null,"sustainable_development_goals":[{"score":1.0,"display_name":"Industry, innovation and infrastructure","id":"https://metadata.un.org/sdg/9"},{"score":0.878000020980835,"display_name":"Affordable and clean energy","id":"https://metadata.un.org/sdg/7"}],"study_designs":[],"awards":[{"id":"https://openalex.org/G2192920692","display_name":null,"funder_award_id":"52077174","funder_id":"https://openalex.org/F4320321001","funder_display_name":"National Natural Science Foundation of China"}],"funders":[{"id":"https://openalex.org/F4320321001","display_name":"National Natural Science Foundation of China","ror":"https://ror.org/01h0zpd94"}],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":29,"referenced_works":["https://openalex.org/W2004798970","https://openalex.org/W2021875185","https://openalex.org/W2074389365","https://openalex.org/W2117032398","https://openalex.org/W2120502199","https://openalex.org/W2151176611","https://openalex.org/W2151767709","https://openalex.org/W2296069615","https://openalex.org/W2478723412","https://openalex.org/W2580446238","https://openalex.org/W2805590867","https://openalex.org/W2918750212","https://openalex.org/W2941210454","https://openalex.org/W3013510423","https://openalex.org/W3018687642","https://openalex.org/W3128499198","https://openalex.org/W3137336163","https://openalex.org/W3138665944","https://openalex.org/W4211175495","https://openalex.org/W4244048911","https://openalex.org/W4251818744","https://openalex.org/W4252915777","https://openalex.org/W4285195407","https://openalex.org/W4293143517","https://openalex.org/W4293812008","https://openalex.org/W4312697767","https://openalex.org/W4386076831","https://openalex.org/W4392543888","https://openalex.org/W4399728033"],"related_works":["https://openalex.org/W4386076831","https://openalex.org/W4396593646","https://openalex.org/W4285195407","https://openalex.org/W4280643534","https://openalex.org/W4405491125","https://openalex.org/W4318003021","https://openalex.org/W2913428662","https://openalex.org/W2803037249","https://openalex.org/W2962061052","https://openalex.org/W2946931514"],"abstract_inverted_index":{"AC":[0],"microgrids":[1],"are":[2,34,131,166,181],"normally":[3],"required":[4],"to":[5,20,24,38,63,77,95,112,184],"work":[6],"in":[7,168,188],"both":[8],"islanded":[9],"mode":[10,14,155],"(IM)":[11],"and":[12,86,116,121,128,163,170],"grid-connected":[13],"(GCM),":[15],"while":[16],"the":[17,27,55,65,97,146,178],"key":[18],"step":[19],"transfer":[21,57],"from":[22],"IM":[23],"GCM":[25],"is":[26,45,126],"presynchronization.":[28],"For":[29],"its":[30,186],"realization,":[31],"active":[32,136],"methods":[33],"preferred":[35],"but":[36,80],"communication":[37],"coordinate":[39],"numerous":[40],"distributed":[41],"generation":[42],"(DG)":[43],"units":[44],"usually":[46],"required.":[47],"To":[48],"fully":[49],"achieve":[50],"autonomous":[51],"control":[52,154,158,165],"of":[53,102,150],"microgrids,":[54],"flexible":[56],"converter":[58],"(FTC)":[59],"has":[60,74],"been":[61,75],"proposed":[62],"facilitate":[64],"auto-synchronization":[66,164],"without":[67],"communication.":[68],"A":[69],"general-purpose":[70],"FTC":[71,93],"(back-to-back":[72],"type)":[73],"verified":[76],"be":[78,142],"effective":[79],"with":[81],"drawbacks":[82],"like":[83],"higher":[84],"cost":[85],"loss.":[87],"This":[88],"paper":[89],"proposes":[90],"a":[91,103,106,109,173],"series":[92,104],"(SFTC)":[94],"overcome":[96],"disadvantages":[98],"above.":[99],"It":[100],"consists":[101],"transformer,":[105],"voltage-source":[107],"converter,":[108],"phase-selection":[110],"switch":[111],"constrain":[113],"voltage":[114],"stress":[115],"auxiliary":[117],"switches":[118],"for":[119,159],"precharging":[120],"bypassing.":[122],"The":[123,152],"steady-state":[124],"model":[125],"established,":[127],"main":[129],"parameters":[130],"designed.":[132],"Through":[133],"theoretical":[134],"analysis,":[135],"power":[137,149,161],"exchanged":[138],"between":[139],"grids":[140],"can":[141],"adjusted":[143],"by":[144],"controlling":[145],"output":[147],"reactive":[148],"SFTC.":[151],"pre-charge,":[153],"transfer,":[156],"auto-frequency":[157],"instant":[160],"support":[162],"illustrated":[167],"detail":[169],"simulated":[171],"through":[172],"comprehensive":[174],"case":[175],"study.":[176],"Finally,":[177],"experiment":[179],"verifications":[180],"carried":[182],"out":[183],"show":[185],"value":[187],"practical":[189],"applications.":[190]},"cited_by_api_url":"https://api.openalex.org/works?filter=cites:W4414908758","counts_by_year":[{"year":2026,"cited_by_count":1}],"updated_date":"2026-11-16T12:05:36.265796","created_date":"2025-10-10T00:00:00"}