{"id":"https://openalex.org/W4414647136","doi":"https://doi.org/10.1109/eeeic/icpseurope64998.2025.11169208","title":"Site Selection Framework for Resilient Power Supply of Telecommunication Base Stations","display_name":"Site Selection Framework for Resilient Power Supply of Telecommunication Base Stations","publication_year":2025,"publication_date":"2025-07-15","ids":{"openalex":"https://openalex.org/W4414647136","doi":"https://doi.org/10.1109/eeeic/icpseurope64998.2025.11169208"},"language":"en","primary_location":{"id":"doi:10.1109/eeeic/icpseurope64998.2025.11169208","doi":"https://doi.org/10.1109/eeeic/icpseurope64998.2025.11169208","is_oa":false,"landing_page_url":"https://doi.org/10.1109/eeeic/icpseurope64998.2025.11169208","pdf_url":null,"source":{"id":"https://openalex.org/S4363607938","display_name":"IEEE International Conference on Environment and Electrical Engineering and IEEE Industrial and Commercial Power Systems Europe (EEEIC / I&CPS Europe)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2025 IEEE International Conference on Environment and Electrical Engineering and 2025 IEEE Industrial and Commercial Power Systems Europe (EEEIC / I&amp;amp;CPS Europe)","raw_type":"proceedings-article"},"volume":null,"type":"conference-paper","is_traditional":true,"indexed_in":["crossref"],"open_access":{"is_oa":false,"oa_status":"closed","oa_url":null,"any_repository_has_fulltext":false},"authorships":[{"author_position":"first","author":{"id":"https://openalex.org/A5010204001","display_name":"Ana Cabrera-Tobar","orcid":"https://orcid.org/0000-0002-4264-9268","observed_orcids":["https://orcid.org/0000-0002-4264-9268"]},"institutions":[{"id":"https://openalex.org/I70764802","display_name":"National Polytechnic School","ror":"https://ror.org/01gb99w41","country_code":"EC","type":"education","lineage":["https://openalex.org/I70764802"]}],"countries":["EC"],"is_corresponding":false,"raw_author_name":"Ana Cabrera-Tobar","raw_affiliation_strings":["DACI, Escuela Polit&#x00E9;cnica Nacional,Quito,Ecuador"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"DACI, Escuela Polit&#x00E9;cnica Nacional,Quito,Ecuador","institution_ids":["https://openalex.org/I70764802"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5119774919","display_name":"Pablo Sarria Montes","orcid":null,"observed_orcids":[]},"institutions":[{"id":"https://openalex.org/I93860229","display_name":"Politecnico di Milano","ror":"https://ror.org/01nffqt88","country_code":"IT","type":"education","lineage":["https://openalex.org/I93860229"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Pablo Sarria Montes","raw_affiliation_strings":["Politecnico di Milano,Department of Energy,Milan,Italy"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Politecnico di Milano,Department of Energy,Milan,Italy","institution_ids":["https://openalex.org/I93860229"]}]},{"author_position":"middle","author":{"id":"https://openalex.org/A5003164258","display_name":"Francesco Grimaccia","orcid":"https://orcid.org/0000-0003-2568-9927","observed_orcids":["https://orcid.org/0000-0003-2568-9927"]},"institutions":[{"id":"https://openalex.org/I93860229","display_name":"Politecnico di Milano","ror":"https://ror.org/01nffqt88","country_code":"IT","type":"education","lineage":["https://openalex.org/I93860229"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Francesco Grimaccia","raw_affiliation_strings":["Politecnico di Milano,Department of Energy,Milan,Italy"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Politecnico di Milano,Department of Energy,Milan,Italy","institution_ids":["https://openalex.org/I93860229"]}]},{"author_position":"last","author":{"id":"https://openalex.org/A5027017319","display_name":"Sonia Leva","orcid":"https://orcid.org/0000-0002-7883-0034","observed_orcids":["https://orcid.org/0000-0002-7883-0034"]},"institutions":[{"id":"https://openalex.org/I93860229","display_name":"Politecnico di Milano","ror":"https://ror.org/01nffqt88","country_code":"IT","type":"education","lineage":["https://openalex.org/I93860229"]}],"countries":["IT"],"is_corresponding":false,"raw_author_name":"Sonia Leva","raw_affiliation_strings":["Politecnico di Milano,Department of Energy,Milan,Italy"],"raw_orcid":null,"affiliations":[{"raw_affiliation_string":"Politecnico di Milano,Department of Energy,Milan,Italy","institution_ids":["https://openalex.org/I93860229"]}]}],"institutions":[],"countries_distinct_count":2,"institutions_distinct_count":2,"corresponding_author_ids":[],"corresponding_institution_ids":[],"apc_list":null,"apc_paid":null,"fwci":0.0,"has_fulltext":false,"cited_by_count":0,"citation_normalized_percentile":{"value":0.26793934,"is_in_top_1_percent":false,"is_in_top_10_percent":false},"cited_by_percentile_year":null,"biblio":{"volume":null,"issue":null,"first_page":"1","last_page":"6"},"is_retracted":false,"is_paratext":false,"is_xpac":false,"primary_topic":{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.8661999702453613,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},"topics":[{"id":"https://openalex.org/T10223","display_name":"Microgrid Control and Optimization","score":0.8661999702453613,"subfield":{"id":"https://openalex.org/subfields/2207","display_name":"Control and Systems Engineering"},"field":{"id":"https://openalex.org/fields/22","display_name":"Engineering"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T11007","display_name":"Hybrid Renewable Energy Systems","score":0.09640000015497208,"subfield":{"id":"https://openalex.org/subfields/2102","display_name":"Energy Engineering and Power Technology"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}},{"id":"https://openalex.org/T14444","display_name":"Power Systems and Renewable Energy","score":0.019500000402331352,"subfield":{"id":"https://openalex.org/subfields/2102","display_name":"Energy Engineering and Power Technology"},"field":{"id":"https://openalex.org/fields/21","display_name":"Energy"},"domain":{"id":"https://openalex.org/domains/3","display_name":"Physical Sciences"}}],"keywords":[{"id":"https://openalex.org/keywords/telecommunication-base-stations","display_name":"telecommunication base stations","score":0.8169999718666077},{"id":"https://openalex.org/keywords/risk-analysis","display_name":"risk analysis","score":0.6600000262260437},{"id":"https://openalex.org/keywords/battery-energy-storage","display_name":"battery energy storage","score":0.9890000224113464},{"id":"https://openalex.org/keywords/hydrogen-fuel-cells","display_name":"hydrogen fuel cells","score":0.9990000128746033},{"id":"https://openalex.org/keywords/zero-emission-energy","display_name":"zero-emission energy","score":0.6499999761581421},{"id":"https://openalex.org/keywords/renewable-energy-potential","display_name":"renewable energy potential","score":0.7599999904632568},{"id":"https://openalex.org/keywords/northern-italy","display_name":"Northern Italy","score":0.6309999823570251}],"concepts":[{"id":"https://openalex.org/C2780561860","wikidata":"https://www.wikidata.org/wiki/Q7531796","display_name":"Site selection","level":2,"score":0.7459999918937683},{"id":"https://openalex.org/C2776784348","wikidata":"https://www.wikidata.org/wiki/Q5762595","display_name":"Microgrid","level":3,"score":0.6460000276565552},{"id":"https://openalex.org/C188573790","wikidata":"https://www.wikidata.org/wiki/Q12705","display_name":"Renewable energy","level":2,"score":0.5856999754905701},{"id":"https://openalex.org/C68649174","wikidata":"https://www.wikidata.org/wiki/Q1379116","display_name":"Base station","level":2,"score":0.5248000025749207},{"id":"https://openalex.org/C187691185","wikidata":"https://www.wikidata.org/wiki/Q2020720","display_name":"Grid","level":2,"score":0.483599990606308},{"id":"https://openalex.org/C81917197","wikidata":"https://www.wikidata.org/wiki/Q628760","display_name":"Selection (genetic algorithm)","level":2,"score":0.4587000012397766},{"id":"https://openalex.org/C127413603","wikidata":"https://www.wikidata.org/wiki/Q11023","display_name":"Engineering","level":0,"score":0.45170000195503235},{"id":"https://openalex.org/C41008148","wikidata":"https://www.wikidata.org/wiki/Q21198","display_name":"Computer science","level":0,"score":0.4456999897956848},{"id":"https://openalex.org/C2780378061","wikidata":"https://www.wikidata.org/wiki/Q25351891","display_name":"Service (business)","level":2,"score":0.41029998660087585},{"id":"https://openalex.org/C544738498","wikidata":"https://www.wikidata.org/wiki/Q861135","display_name":"Distributed generation","level":3,"score":0.3833000063896179},{"id":"https://openalex.org/C10558101","wikidata":"https://www.wikidata.org/wiki/Q689855","display_name":"Smart grid","level":2,"score":0.37070000171661377},{"id":"https://openalex.org/C41291067","wikidata":"https://www.wikidata.org/wiki/Q1897785","display_name":"Photovoltaic system","level":2,"score":0.35899999737739563},{"id":"https://openalex.org/C73916439","wikidata":"https://www.wikidata.org/wiki/Q837718","display_name":"Energy storage","level":3,"score":0.35260000824928284},{"id":"https://openalex.org/C158154518","wikidata":"https://www.wikidata.org/wiki/Q7310970","display_name":"Relevance (law)","level":2,"score":0.3515999913215637},{"id":"https://openalex.org/C89227174","wikidata":"https://www.wikidata.org/wiki/Q2388981","display_name":"Electric power system","level":3,"score":0.3418000042438507},{"id":"https://openalex.org/C76155785","wikidata":"https://www.wikidata.org/wiki/Q418","display_name":"Telecommunications","level":1,"score":0.3379000127315521},{"id":"https://openalex.org/C201995342","wikidata":"https://www.wikidata.org/wiki/Q682496","display_name":"Systems engineering","level":1,"score":0.31439998745918274},{"id":"https://openalex.org/C423512","wikidata":"https://www.wikidata.org/wiki/Q383973","display_name":"Electricity generation","level":3,"score":0.3086000084877014},{"id":"https://openalex.org/C2776190866","wikidata":"https://www.wikidata.org/wiki/Q1341477","display_name":"Energy supply","level":3,"score":0.3086000084877014},{"id":"https://openalex.org/C163258240","wikidata":"https://www.wikidata.org/wiki/Q25342","display_name":"Power (physics)","level":2,"score":0.30649998784065247},{"id":"https://openalex.org/C184773241","wikidata":"https://www.wikidata.org/wiki/Q387400","display_name":"Mains electricity","level":3,"score":0.3025999963283539},{"id":"https://openalex.org/C2780579389","wikidata":"https://www.wikidata.org/wiki/Q17083991","display_name":"Supply network","level":3,"score":0.29910001158714294},{"id":"https://openalex.org/C555008776","wikidata":"https://www.wikidata.org/wiki/Q267298","display_name":"Battery (electricity)","level":3,"score":0.28929999470710754},{"id":"https://openalex.org/C2742236","wikidata":"https://www.wikidata.org/wiki/Q924713","display_name":"Efficient energy use","level":2,"score":0.27219998836517334},{"id":"https://openalex.org/C192126672","wikidata":"https://www.wikidata.org/wiki/Q1068715","display_name":"Telecommunications network","level":2,"score":0.26179999113082886},{"id":"https://openalex.org/C7453809","wikidata":"https://www.wikidata.org/wiki/Q568469","display_name":"Energy carrier","level":3,"score":0.2565000057220459},{"id":"https://openalex.org/C114563136","wikidata":"https://www.wikidata.org/wiki/Q19725982","display_name":"Network planning and design","level":2,"score":0.2529999911785126}],"mesh":[],"locations_count":2,"locations":[{"id":"doi:10.1109/eeeic/icpseurope64998.2025.11169208","doi":"https://doi.org/10.1109/eeeic/icpseurope64998.2025.11169208","is_oa":false,"landing_page_url":"https://doi.org/10.1109/eeeic/icpseurope64998.2025.11169208","pdf_url":null,"source":{"id":"https://openalex.org/S4363607938","display_name":"IEEE International Conference on Environment and Electrical Engineering and IEEE Industrial and Commercial Power Systems Europe (EEEIC / I&CPS Europe)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":null,"host_organization_name":null,"host_organization_lineage":[],"host_organization_lineage_names":[],"type":"conference"},"license":null,"license_id":null,"version":"publishedVersion","is_accepted":true,"is_published":true,"raw_source_name":"2025 IEEE International Conference on Environment and Electrical Engineering and 2025 IEEE Industrial and Commercial Power Systems Europe (EEEIC / I&amp;amp;CPS Europe)","raw_type":"proceedings-article"},{"id":"pmh:oai:re.public.polimi.it:11311/1304588","doi":null,"is_oa":false,"landing_page_url":"https://hdl.handle.net/11311/1304588","pdf_url":null,"source":{"id":"https://openalex.org/S4306400312","display_name":"Virtual Community of Pathological Anatomy (University of Castilla La Mancha)","issn_l":null,"issn":null,"is_oa":false,"is_in_doaj":false,"is_core":false,"listed_in":[],"host_organization":"https://openalex.org/I79189158","host_organization_name":"University of Castilla-La Mancha","host_organization_lineage":["https://openalex.org/I79189158"],"host_organization_lineage_names":[],"type":"repository"},"license":null,"license_id":null,"version":"submittedVersion","is_accepted":false,"is_published":false,"raw_source_name":null,"raw_type":"info:eu-repo/semantics/conferenceObject"}],"best_oa_location":null,"sustainable_development_goals":[{"id":"https://metadata.un.org/sdg/9","score":1.0,"display_name":"Industry, innovation and infrastructure"},{"id":"https://metadata.un.org/sdg/7","score":0.9853000044822693,"display_name":"Affordable and clean energy"},{"id":"https://metadata.un.org/sdg/13","score":0.821399986743927,"display_name":"Climate action"},{"id":"https://metadata.un.org/sdg/11","score":0.7250000238418579,"display_name":"Sustainable cities and communities"}],"study_designs":[],"awards":[],"funders":[{"id":"https://openalex.org/F4320320300","display_name":"European Commission","ror":"https://ror.org/00k4n6c32"}],"has_content":{"pdf":false,"grobid_xml":false},"content_urls":null,"referenced_works_count":16,"referenced_works":["https://openalex.org/W2512237184","https://openalex.org/W2517461506","https://openalex.org/W2915058086","https://openalex.org/W3177253471","https://openalex.org/W3194546132","https://openalex.org/W3203677392","https://openalex.org/W4211038231","https://openalex.org/W4225512289","https://openalex.org/W4309684544","https://openalex.org/W4362446409","https://openalex.org/W4392120278","https://openalex.org/W4402627914","https://openalex.org/W4404564369","https://openalex.org/W4404565130","https://openalex.org/W4407783173","https://openalex.org/W4408165785"],"related_works":["https://openalex.org/W6906896726","https://openalex.org/W7135197490","https://openalex.org/W2025188288","https://openalex.org/W2525771417","https://openalex.org/W4400315073","https://openalex.org/W4415358039","https://openalex.org/W4410134357","https://openalex.org/W4416574982","https://openalex.org/W4293238810","https://openalex.org/W2123694596"],"abstract_inverted_index":{"This":[0],"paper":[1],"presents":[2],"a":[3,23],"guideline":[4],"for":[5,100],"the":[6,97],"resilient":[7],"site":[8],"selection":[9,44],"and":[10,52,64,78,85,107],"design":[11,56],"of":[12,45,67],"microgrids":[13],"to":[14,17,38,82],"supply":[15],"power":[16],"telecommunication":[18],"Base":[19],"Stations":[20],"(BS),":[21],"with":[22,59],"focus":[24],"on":[25,49],"zeroemission":[26],"solutions.":[27],"The":[28,88],"proposed":[29],"approach":[30],"includes":[31],"four":[32],"main":[33],"steps:":[34],"(1)":[35],"risk":[36],"analysis":[37],"identify":[39],"high-risk":[40],"areas,":[41],"(2)":[42],"strategic":[43],"critical":[46],"BSs":[47],"based":[48],"network":[50],"relevance":[51],"exposure,":[53],"(3)":[54],"microgrid":[55],"in":[57,92],"compliance":[58],"Photovoltaic":[60],"(PV)":[61],"installation":[62],"standards,":[63],"(4)":[65],"integration":[66],"complementary":[68],"zero-emission":[69],"technologies":[70,111],"such":[71],"as":[72],"Battery":[73],"Energy":[74],"Storage":[75],"Systems":[76],"(BESS)":[77],"hydrogen":[79],"fuel":[80],"cells":[81],"overcome":[83],"spatial":[84],"generation":[86,103],"limitations.":[87],"methodology":[89],"is":[90],"applied":[91],"northern":[93],"Italy.":[94],"Results":[95],"show":[96],"real":[98],"potential":[99],"renewable":[101],"energy":[102],"at":[104],"selected":[105],"sites":[106],"demonstrate":[108],"how":[109],"combining":[110],"can":[112],"ensure":[113],"resilient,":[114],"uninterrupted":[115],"service":[116],"even":[117],"during":[118],"grid":[119],"outages.":[120]},"counts_by_year":[],"updated_date":"2026-10-06T10:28:23.643775","created_date":"2025-10-10T00:00:00"}
